Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 378
Filtrer
1.
Medwave ; 24(05)30-06-2024.
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1570233

RÉSUMÉ

Introduction Platelet concentrates are blood products obtained from donor's blood, and their conservation must be subject to a strict quality control process to guarantee a safe and high-performance product in treating diseases that require their use. Methods We designed a cross-sectional study to determine the total compliance rate in platelet concentrates obtained in the blood bank of the Cayetano Heredia Hospital in Lima during November and December of 2019. The Buffy method Coat obtained the platelet concentrates, and parameters such as platelet count and residual leukocytes, pH, and swirling effect were evaluated according to the National Hemotherapy and Blood Bank Program criteria. Results The platelet count had a mean of 6.66 ± 3.94 x 10¹°/µL, the platelet concentrates had a mean of 56.30 ± 6.22 mL, and all, without exception, had the presence of the Swirling phenomenon. The pH had a mean of 7.64 ± 0.15, while the leukocyte count had a mean of 4.22 ± 3.51 x 107/µL. Regarding compliance by the parameters evaluated, it was evident that the platelet and leukocyte count had moderate compliance rates of 43.6% and 24.1%, while the pH and swirling effect had rates of 100% in both cases. The total compliance rate was 54.9% (95% confidence interval: 46.0 to 63.5). Conclusions The compliance rate of platelet concentrates is moderate, and it is necessary to implement a process of continuous quality improvement in the blood bank.


Introducción Los concentrados plaquetarios son hemoderivados obtenidos de la sangre, y su conservación debe estar supeditada a un estricto proceso de control de calidad para garantizar un producto inocuo y de alto rendimiento en el tratamiento de enfermedades que requieran su uso. Métodos Diseñamos un estudio transversal que tuvo por objetivo determinar la tasa de conformidad total en concentrados plaquetarios obtenidos en el banco de sangre del Hospital Cayetano Heredia de Lima durante los meses de noviembre y diciembre del año 2019. Los concentrados plaquetarios fueron obtenidos por el método de Buffy Coat y se evaluaron parámetros como el recuento de plaquetas y leucocitos residuales, pH y efecto swirling, según criterios del Programa Nacional de Hemoterapia y Bancos de Sangre. Resultados El recuento de plaquetas tuvo una media de 6.66 ± 3.94 x1010/µL y los concentrados plaquetarios tuvieron una media de 56.30 ± 6.22 mL, y todos sin excepción tuvieron presencia de fenómeno Swirling. El pH tuvo una media de 7.64 ± 0.15, mientras que el recuento de leucocitos tuvo una media de 4.22 ± 3.51 x107/µL. En cuanto al cumplimiento por parámetro evaluado, se evidenció que el recuento de plaquetas y leucocitos tuvieron tasas de conformidad de 43.6% y 24.1%, mientras que el pH y efecto swirling tuvieron tasas del 100% en ambos casos. La tasa de conformidad total fue 54.9% (CI95%: 46.0 a 63.5). Conclusiones La tasa de conformidad de los concentrados plaquetarios es moderada, y se requiere implementar un proceso de mejora continua de la calidad en el banco de sangre.

2.
Article de Chinois | WPRIM | ID: wpr-1024989

RÉSUMÉ

【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level

3.
Article de Chinois | WPRIM | ID: wpr-1024990

RÉSUMÉ

【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.

4.
Article de Chinois | WPRIM | ID: wpr-1024991

RÉSUMÉ

【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

5.
Article de Chinois | WPRIM | ID: wpr-1024992

RÉSUMÉ

【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

6.
Article de Chinois | WPRIM | ID: wpr-1039542

RÉSUMÉ

【Objective】 To achieve supervision and management of the whole business process of blood center, raise productivity and ensure blood quality by enabling blood center managers comprehensively grasp the key business operation situation of the whole process at anytime and anywhere. 【Methods】 A whole business process supervision and management system was established covering background of preparation, business scope, content of position supervision and management, overall framework design, interface design of management and supervision management, physical database design, program development and online debugging, and was integrated with the blood bank management information system. The display and management were through a mobile APP to record key indicators of business process from blood collection to blood supply timely and comprehensively. Statistical analysis was conducted on total collection volume, total preparation volume and total supply volume, as well as discarding rate of test unqualified and of non-test unqualified (lipemic blood excluded) in 2023 and 2022. 【Results】 We established a mobile APP based on a blood bank management information system for business supervision and management of whole process, and achieved management by phones. After its implementation in 2023, the total collection volume, total preparation volume and total supply volume in 2023 were all higher than those in 2022, with growth rates of 5.88% (13 247/225 454 U), 4.73% (24 156/510 698 U), and 6.70% (34 814/519 914 U), respectively. The discarding rate in 2023 was lower than that in 2022 (0.54%, 2 868/534 854 U) vs (0.60%, 3 047/510 698 U) (P<0.01), and the non-test unqualified discarding rate (lipemic blood excluded) in 2023 was significantly lower than that in 2022(0.12%, 649/534 854 U) vs (0.19%, 991/510 698 U)(P<0.01). 【Conclusion】 The construction of supervision and management system of a whole business process based on blood bank management information system can meet the standardized service needs of managers at anytime and anywhere, continuously raise productivity and the standardization and scientific level of blood bank management, thus ensuring blood supply.

7.
AlQalam Journal of Medical and Applied Sciences ; 7(1): 142-146, 2024. figures, tables
Article de Anglais | AIM | ID: biblio-1553184

RÉSUMÉ

The identification and categorization of blood groups play a crucial role in transfusion medicine as it allows for safe and compatible transfusions. Among the various blood group systems, the ABO and Rhesus blood grouping systems have special clinical significance. Understanding the distribution and frequency of ABO and Rhesus blood groups within a specific community is essential for healthcare planning, especially when it comes to blood supply management and organ transplantation. Additionally, studies have also shown a relationship between ABO blood groups and the onset and spread of diseases. Therefore, this study was conducted to detect the distribution and frequency of ABO and Rhesus blood groups in AzZawya City, Libya. In this retrospective study, data from the blood bank at Zawia Medical Center were collected over three years to detect the distribution of ABO and Rh blood groups among 5187 donors and admitted patients. The result shows that blood group O is the dominant among all study subjects (45%), as well as, among males (48.2%), and females (42.2%). Blood group A is the second most common at 34.6% among total, 33% among males, and 36% among females. For Rhesus antigens 89.4% of study subjects were Rhesus positive, 87.3% for males and 80% for females. In addition, the results show a statistically significant association between gender and blood group distribution p <0.001. Knowing the most common blood types helps maintain adequate blood bank supplies.


Sujet(s)
Humains , Femelle
8.
Rev. bras. enferm ; 77(3): e20230209, 2024. tab, graf
Article de Anglais | LILACS-Express | LILACS, BDENF | ID: biblio-1569660

RÉSUMÉ

ABSTRACT Objectives: to analyze the trends and factors associated with family refusal of skin donation for transplantation. Methods: this cross-sectional study was conducted in the State of São Paulo, with family authorization terms collected from 2001 to 2020. The variables analyzed included year, age, gender, cause of death, and type of institution. Data were analyzed using linear and multiple logistic regression, with the Odds Ratio estimated at p<0.05 for statistical significance. Results: 1,355 individuals refused skin donation. The trend of refusals decreased between 2001 and 2009 in the age groups of 0-11 years and 12-19 years, but increased in the group aged ≥60 years. This trend continued to decrease in the 0-11 years group from 2010 to 2020, and increased in the 20-40 years group. Males and the age groups of 20-40 years, 41-59 years, and ≥60 years exhibited 27%, 34%, 47%, and 53% lower chances of refusal, respectively. Conclusions: there is an urgent need for measures to mitigate the high number of refusals associated with skin donation.


RESUMEN Objetivos: analizar la tendencia y los factores asociados al rechazo familiar de la donación de piel para trasplante. Métodos: estudio transversal desarrollado en el Estado de São Paulo con los términos de autorización familiar firmados entre 2001 y 2020. Las variables analizadas fueron: año, edad, sexo, causa del deceso y tipo de institución. Los datos fueron analizados mediante regresión lineal y logística múltiple, con la estimación del Odds Ratio, adoptando p<0,05 como significancia estadística. Resultados: 1.355 individuos rechazaron la donación de piel. La tendencia de rechazos fue decreciente (2001-2009) en los grupos de edad de 0-11 años y de 12-19 años, y creciente en el grupo de ≥60 años. La tendencia siguió siendo decreciente (2010-2020) en el grupo de edad de 0-11 años y creciente en el de 20-40 años. El género masculino y los grupos de edad de 20-40 años, 41-59 años y ≥60 años presentaron, respectivamente, 27%, 34%, 47% y 53% menos probabilidades de rechazo. Conclusiones: es urgente la necesidad de medidas que busquen mitigar el alto número de rechazos asociados a la donación de piel.


RESUMO Objetivos: analisar a tendência e os fatores associados à recusa familiar de doação de pele para transplante. Métodos: estudo transversal desenvolvido no Estado de São Paulo com os termos de autorização familiar firmados entre 2001 e 2020. As variáveis analisadas foram: ano, idade, sexo, causa do óbito e tipo da instituição. Os dados foram analisados por meio de regressão linear e logística múltipla, com o Odds Ratio estimado, adotando-se p<0,05 como significância estatística. Resultados: 1.355 indivíduos recusaram a doação de pele. A tendência de recusas foi decrescente (2001-2009) nas faixas etárias de 0-11 anos e de 12-19 anos e crescente na faixa de ≥60 anos. A tendência permaneceu decrescente (2010-2020) na faixa etária de 0-11 anos e crescente na de 20-40 anos. O sexo masculino e as faixas etárias de 20-40 anos, 41-59 anos e ≥60 anos apresentaram, respectivamente, 27%, 34%, 47% e 53% menores chances de recusa. Conclusões: é urgente a necessidade de medidas que visem atenuar o alto número de recusas associadas à doação de pele.

9.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3160-3165
Article | IMSEAR | ID: sea-225244

RÉSUMÉ

Purpose: To curtail the potential of donor corneal tissue disseminating fungi to the recipient抯 eye, we evaluated the addition of amphotericin B to McCarey?Kaufman (M?K)梒orneal storage medium supplemented with colistin. Methods: Amphotericin B was examined for its ability to inhibit the growth of Candida albicans and Aspergillus flavus using a microbroth dilution test and checkerboard assay in combination with only gentamicin and a combination of colistin, gentamicin, and amphotericin B. The safety on epithelium and endothelium was evaluated by 3?(4,5?dimethylthiazol?2?yl)?2, 5?diphenyltetrazolium bromide (MTT) assay. Results: The minimal inhibitory concentration of gentamicin was found to be >256 ?g/ml against both C. albicans and A. flavus, whereas that of amphotericin B was found to be in a range of 0.25�5 and 1�?g/ml for C. albicans and A. flavus, respectively. According to the checkerboard assay, 80% (4/5) of C. albicans isolates and 100% (5/5) of A. flavus isolates responded synergistically to the combination of amphotericin B and gentamicin, but only 20% (1/5) of C. albicans isolates showed an additive effect. None of the tested isolates displayed antagonism. The combined effect of the three drugs also did not display any antagonistic effect. Additionally, the MTT assay reveals no toxic effect of the antimicrobials used on corneal epithelial and endothelial cells. Conclusion: In vitro experiments demonstrate that amphotericin B is not toxic to either epithelium or endothelium and is a promising additive to the M?K medium supplemented with colistin.

10.
Article | IMSEAR | ID: sea-218858

RÉSUMÉ

This paper titled A Study of Consumption Behaviour of Plastic Card Holders of Ahmedabad City is aimed at knowing which types of plastic cards (credit card, debit/ATM card, charge card and smart card) are held by respondents and out of them which is the most used plastic card, the number of plastic cards used, most popular card issuing bank and most preferred brand of plastic card of respondents of Ahmedabad city. The findings are that majority of card holders have debit card and it is the most preferred card for purchasing goods and services by respondents. Respondents possess more than one cards. Only 32% card holders have only one card and nearly 68 % card holders have more than one card. Axis bank is the most popular card issuing bank (20.2%) amongst majority of respondents followed by SBI. The majority of respondents (34.6%) are using Classic brand plastic card. This revels that other brands like Classic Plus, Edge, Global, Gold, Neo, Platinum, Priority, Privilege,Titanium etc. are less popular.

11.
Arch. argent. pediatr ; 121(2): e202102511, abr. 2023. tab, ilus
Article de Anglais, Espagnol | LILACS, BINACIS | ID: biblio-1418574

RÉSUMÉ

Introducción. El grado de acidez Dornic (AD), medida indirecta del grado de contaminación de la leche humana cruda (LHC), proporciona información sobre la calidad de esta. Recién extraída, el valor oscila entre 1,0° y 4,0° (óptimo). Descalifica el consumo si es >8,0 °D. Se evaluó la correlación de la AD de la LHC de donantes internas (DI) y externas (DE) según el tiempo de conservación hasta la pasteurización, y se determinó la prevalencia de AD ≤4 ºD. Población y método. Estudio retrospectivo analítico. Resultados. Sobre 13 203 muestras, la AD a partir del día 14 de conservación fue menor en las donantes internas, de 2,92; (IC95% 2,69-3,15) versus 4,01 (IC95%: 3,94-4,08); p <0,001] con mayor proporción de AD ≤4 ºD (88 % en DI versus 76 % en DE); OR: 2,30 (IC95%: 1,25-4,24); p = 0,003. Coeficiente de correlación para las DI: R 2 :0; p = 1). Conclusión. La AD a partir del día 14 fue menor en DI, presentando mayor prevalencia de AD ≤ 4ºD. No existió correlación entre el tiempo de conservación y la AD en las DI.


Introduction. The degree of Dornic acidity (DA) is an indirect measure of milk contamination and quality. In freshly expressed milk, DA ranges between 1.0 and 4.0 (optimal). If DA is > 8.0 °D, it should be discarded. The correlation between DA in raw breast milk from internal donors (ID) and external donors (ED) based on storage time until pasteurization was assessed. Population and method. Retrospective, analytical study. Results. In 13 203 samples, DA was lower in IDs as of 14 days of storage: 2.92 (95% CI: 2.69­3.15) versus 4.01 (95% CI: 3.94­4.08), with a higher proportion of DA ≤ 4 °D (88% in IDs versus 76% in EDs); odds ratio: 2.30 (95% CI: 1.25­4.24). Conclusion. DA as of 14 days of storage was lower in IDs, with a higher prevalence of DA ≤ 4 °D. No correlation was observed between storage time and DA in ID samples.


Sujet(s)
Humains , Pasteurisation/méthodes , Lait humain , Facteurs temps , Études rétrospectives
12.
Indian J Ophthalmol ; 2023 Mar; 71(3): 881-887
Article | IMSEAR | ID: sea-224892

RÉSUMÉ

Purpose: Comparison of the conjunctiva related complication rates and success rates among eyes with Ahmed glaucoma valve (AGV) implantation in which eye bank derived scleral and corneal patch grafts had been used to cover the tube. Methods: Retrospective comparative study. Patients who underwent AGV implantation between January 2000 to December 2016 were included. Demographic, clinical data, intra and post operative data was obtained from electronic medical records. Conjunctiva related complications were divided into two groups: with and without implant exposure. Conjunctiva related complication rates, success rate, risk factors among eyes with corneal and scleral patch graft were compared. Results: Three hundred and twenty three eyes of 316 patients underwent AGV implantation. Scleral patch graft was used in 214 eyes of 210 patients (65.9%) and corneal patch graft was used in 109 eyes of 107 patients (34%). Median follow up was 14 months. There was no significant difference in the conjunctiva related complication rate (7.3 % in corneal patch graft versus 7.0% in scleral patch graft;p=0.5) and conjunctival dehiscence rate (3.7% versus 4.6%, P = 0.7) among the two groups. Success rate was significantly higher in the corneal patch graft group versus the scleral patch graft group (98% versus 72%; p=0.001). Eyes with corneal patch graft had a higher survival rate (P = 0.01). Conclusion: There was no significant difference in the rate of conjunctiva related complications following corneal and scleral patch grafts used to cover the AGV tube. Eyes with corneal patch graft had a higher success rate and survival rate.

13.
Rev. cuba. salud pública ; 49(1)mar. 2023.
Article de Espagnol | LILACS, CUMED | ID: biblio-1441857

RÉSUMÉ

El acceso universal a las transfusiones de sangre depende de diversos factores localizados dentro y fuera de los servicios de salud. Motivados por ser este un tema infrecuente, el trabajo tiene el objetivo de analizar desde una perspectiva multidimensional y holística los determinantes externos de la disponibilidad de sangre para las transfusiones. El desarrollo socioeconómico constituye un importante factor dinamizador porque condiciona, de cierta manera, la infraestructura del sistema sanitario e incide sobre los factores epidemiológicos, sociodemográficos y jurídicos. A su vez, estos influyen en la organización de las actividades y la complejidad de la asistencia sanitaria, factores que otorgan un sentido positivo o negativo a la disponibilidad de sangre. Tomarlos en consideración al diseñar las políticas de salud relacionadas con el uso de la sangre permite una mayor precisión en las intervenciones locales que contribuyan a mejorar la seguridad de las transfusiones(AU)


Universal access to blood transfusions depends on a number of localized factors both inside and outside health services. Motivated by being an infrequent topic, this work aims to analyze from a multidimensional and holistic perspective the external determinants of the availability of blood for transfusions. Socio-economic development is an important dynamic factor because it conditions, in a certain way, the infrastructure of the health system and affects epidemiological, sociodemographic and legal factors. In turn, these influence the organization of activities and the complexity of health care, factors that give a positive or negative meaning to the availability of blood. Taking them into consideration when designing health policies related to the use of blood allows greater precision in local interventions that contribute to improving the safety of transfusions(AU)


Sujet(s)
Humains , Mâle , Femelle , Banques de sang , Transfusion sanguine/méthodes
14.
Rev. bras. ortop ; 58(1): 23-29, Jan.-Feb. 2023. tab, graf
Article de Anglais | LILACS | ID: biblio-1441344

RÉSUMÉ

Abstract Objective The present study aims to highlight the significance of the nucleic acid test (NAT) for musculoskeletal tissue donation and to compare the sensitivity of this test on the different available platforms. Method The present study is a retrospective survey in a human tissue bank database and an integrative literature review encompassing the last 10 years. The PubMed portal and the SCOPUS, CINAHL, and Web of Science databases were queried for articles. Results We found no specific studies on the use and sensitivity of NAT in braindead tissue donors. The information presented in the present study consists of specific contents intended for the Brazilian Blood Transfusion Network (Hemorrede Transfusional Nacional, in Portuguese) and internal retrospective data from a tissue bank located at a city in the state of São Paulo, Brazil. Conclusions The NAT is effective in blood samples from living patients. However, since biochemical reactions in braindead patients can be different, specific research, platforms, or both are crucial to tissue banks.


Resumo Objetivo Evidenciar a importância da realização do teste de ácido nucleico (NAT, na sigla em inglês) para doação de tecidos musculoesqueléticos, assim como comparar a sensibilidade deste exame nas diferentes plataformas existentes no mercado. Método Trata-se de um levantamento retrospectivo no banco de dados de um determinado Banco de Tecidos Humanos e de uma revisão integrativa da literatura, operacionalizada nos últimos 10 anos. As buscas de artigos ocorreram no portal PubMed e nas bases de dados SCOPUS, CINAHL e Web of Science. Resultados Não foram encontrados estudos específicos sobre a utilização e a sensibilidade do exame NAT em pacientes doadores de tecidos com morte encefálica (ME), sendo as informações apresentadas no presente estudo conteúdos específicos destinados à Hemorrede Transfusional Nacional e aos dados retrospectivos internos de um Banco de Tecidos do interior do estado de São Paulo, Brasil. Conclusões O exame NAT se apresenta efetivo em amostras de sangue de pacientes vivos. Porém, reações bioquímicas em pacientes com condições de ME podem se apresentar de formas diferenciadas, tornando-se indispensáveis a realização de pesquisas específicas e/ou a indicação de plataformas aos Bancos de Tecidos.


Sujet(s)
Humains , Acides nucléiques , Sélection de donneurs
15.
Article de Chinois | WPRIM | ID: wpr-1004887

RÉSUMÉ

【Objective】 To analyze the reasons for the invalidity of blood nucleic acid test results, and to explore the countermeasures to reduce the invalidity of the test. 【Methods】 From 2019 to 2021, the number of tests performed in our laboratory for Cobas s201 blood nucleic acid screening system and the number of batches and tests with invalid results were counted, and the types and reasons of invalid results were analyzed. 【Results】 From 2019 to 2021, the Cobas s201 nucleic acid detection system detected a total of 5, 420 batches and 127, 950 pools, and the invalid rate of batches and pools were 1.83% and 1.97%, respectively. The types of invalid results can be summarized as improper operation, sample quality problems, invalid quality control (IQC), equipment failure and others. Among them, IQC and equipment failure were the main reasons for invalid results, accounting for 44.51% and 39.96%, respectively. IQC was mainly related to cross-contamination of samples and insufficient mixing of quality control products. Equipment failures mostly occurred in the robotic arm gripper of the nucleic acid extraction instrument and the TC module of the amplification instrument. 【Conclusion】 The laboratory should conduct quality monitoring for invalid results, and take targeted improvement measures, especially to reduce invalid results caused by invalid quality control and instrument failure.

16.
Acta Anatomica Sinica ; (6): 123-126, 2023.
Article de Chinois | WPRIM | ID: wpr-1015254

RÉSUMÉ

Objective The traditional round incision or cross incision brain harvesting method can not meet the requirements of protecting the donor's remains. In this study, the method of brain removal through a posterior incision on the scalp of both ears was proposed, which effectively protected the donor's remains. Methods Adopting the incision 2. 0 cm above the external occipital protuberance to the most front edge of the auricle to obtain a complete brain. Results The incision did not involve the head and face skin, which was small and conducive to suture repair and reduce exudation. Conclusion The incision effectively protects the donor' s remains, and it will be conducive to the establishment and development of the brain bank.

17.
Chinese Journal of Biotechnology ; (12): 4463-4481, 2023.
Article de Chinois | WPRIM | ID: wpr-1008036

RÉSUMÉ

Recently, the gut microbiota-based live biotherapeutics (LBPs) development, the interaction between gut microbial species and the host, and the mining of new antimicrobial peptides, enzymes and metabolic pathway have received increasing attention. Culturing gut microbial species is therefore of great importance. This review systemically compared the construction advances of gut microbial culture banks and also analyzed the differences of methods used by research groups to give insight into the construction and enrichment of gut microbial resources. Presently, the gut microbial culture banks have included more than 1 000 bacterial species, belonging to 12 phyla, 22 classes, 39 orders, 96 families, and 358 genera. Among these, Firmicutes, Proteobacteria, Bacteroidota, and Actinomycetota exhibited the greatest diversities at the species level. The sequencing data showed that there are more than 2 000 species inhibited in the human gut. Therefore, the cultured gut microbial species are far from saturation. In terms of the construction method, the stool samples were pre-treated with ethanol or directly spread and cultured in the non-selective nutritional rich medium (represented by Gifu anaerobic medium) to obtain single colony. Then single colony was further purified. Generally, a simplified isolation and culture method is sufficient to obtain the most common and important intestinal bacterial species, such as Bifidobacteria-Lactobacillus, Akkermansia muciniphila, Faecalibacterium prausnitzii, Prevotella and S24-7 family strains. Finally, microbial resources with great diversities at the strain level are required for further functional research and product development. Samples covering hosts with distinct physiological status, diets or regions are necessary.


Sujet(s)
Humains , Microbiome gastro-intestinal , Microbiote , Bactéries
18.
Braz. j. biol ; 83: 1-10, 2023. tab, ilus
Article de Anglais | LILACS, VETINDEX | ID: biblio-1468807

RÉSUMÉ

Allium sativum L. is an herb of the Alliaceae family with a specific taste and aroma and medicinal and nutraceutical properties that are widely marketed in several countries. Brazil is one of the largest importers of garlic in the world, despite of its production is restricted and limited to internal consumption. Thus, explore the genetic diversity of commercial garlic conserved at germplasm banks is essential to generate additional genetic information about its economically important crop. A suitable tool for this purpose is the cytogenetic characterisation of these accessions. This study aimed to characterise the cytogenetic diversity among seven accessions of garlic from a Germplasm Bank in Brazil. The karyotypes were obtained by conventional staining and with chromomycin A3 (CMA) and 4,6-diamidino-2-phenylindole (DAPI) fluorochromes. All accessions analysed showed chromosome number 2n= 16, karyotype formula 6M+2SM, symmetrical karyotypes, reticulate interphase nuclei, and chromosomes with uniform chromatin condensation from prophase to metaphase. The fluorochromes staining showed differences in the amount and distribution of heterochromatin along the chromosomes and between accessions studied. Based on the distribution pattern of these small polymorphisms, it was possible to separate the seven accessions into three groups. It was also possible to differentiate some of the accessions individually. One of the results obtained showed a heteromorphic distension of the nucleolar organiser region observed on the chromosome pairs 6 or 7 with peculiar characteristics. It was suggested for example, that the heteromorphic block of heterochromatin (CMA+++/DAPI-) on chromosome 6 of the "Branco Mineiro Piauí" accession can be used as a marker to identify this genotype or may be associated with some character of economic interest.


Allium sativum L. é uma erva da família Alliaceae com sabor e aroma específicos e propriedades medicinais e nutracêuticas amplamente comercializada em diversos países. O Brasil é um dos maiores importadores de alho do mundo, apesar da sua produção ser restrita e limitada ao consumo interno. Assim, explorar a diversidade genética do alho comercial conservado em bancos de germoplasma é essencial para fornecer informações genéticas adicionais acerca dessa cultura economicamente importante. Uma ferramenta adequada para esse fim é a caracterização citogenética desses acessos. Este estudo teve como objetivo caracterizar a diversidade citogenética entre sete acessos de alho de um Banco de Germoplasma no Brasil. Os cariótipos foram obtidos por coloração convencional e com os fluorocromos de cromomicina A3 (CMA) e 4,6-diamidino-2-fenilindol (DAPI). Todos os acessos analisados apresentaram número cromossômico 2n = 16, fórmula cariotípica 6M + 2SM, cariótipos simétricos, núcleos reticulados em intérfase e cromossomos com condensação uniforme da cromatina da prófase para a metáfase. A coloração com fluorocromos mostrou diferenças na quantidade e distribuição de heterocromatina ao longo dos cromossomos e entre os acessos estudados. Com base no padrão de distribuição desses pequenos polimorfismos, foi possível separar os sete acessos em três grupos. Também foi possível diferenciar individualmente alguns dos acessos. Um dos resultados obtidos mostrou distensão heteromórfica da região organizadora nucleolar observada nos pares dos cromossomos 6 ou 7 com características peculiares. Foi sugerido, por exemplo, que o bloco heteromórfico de heterocromatina (CMA +++ / DAPI-) no cromossomo 6 do acesso “Branco Mineiro Piauí” pode ser usado como um marcador para identificar esse genótipo ou pode estar associado a algum caráter de interesse econômico.


Sujet(s)
Ail/cytologie , Ail/génétique , Hétérochromatine
19.
Braz. j. biol ; 832023.
Article de Anglais | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469023

RÉSUMÉ

Abstract Allium sativum L. is an herb of the Alliaceae family with a specific taste and aroma and medicinal and nutraceutical properties that are widely marketed in several countries. Brazil is one of the largest importers of garlic in the world, despite of its production is restricted and limited to internal consumption. Thus, explore the genetic diversity of commercial garlic conserved at germplasm banks is essential to generate additional genetic information about its economically important crop. A suitable tool for this purpose is the cytogenetic characterisation of these accessions. This study aimed to characterise the cytogenetic diversity among seven accessions of garlic from a Germplasm Bank in Brazil. The karyotypes were obtained by conventional staining and with chromomycin A3 (CMA) and 4,6-diamidino-2-phenylindole (DAPI) fluorochromes. All accessions analysed showed chromosome number 2n = 16, karyotype formula 6M+2SM, symmetrical karyotypes, reticulate interphase nuclei, and chromosomes with uniform chromatin condensation from prophase to metaphase. The fluorochromes staining showed differences in the amount and distribution of heterochromatin along the chromosomes and between accessions studied. Based on the distribution pattern of these small polymorphisms, it was possible to separate the seven accessions into three groups. It was also possible to differentiate some of the accessions individually. One of the results obtained showed a heteromorphic distension of the nucleolar organiser region observed on the chromosome pairs 6 or 7 with peculiar characteristics. It was suggested for example, that the heteromorphic block of heterochromatin (CMA+++/DAPI-) on chromosome 6 of the Branco Mineiro Piauí accession can be used as a marker to identify this genotype or may be associated with some character of economic interest.


Resumo Allium sativum L. é uma erva da família Alliaceae com sabor e aroma específicos e propriedades medicinais e nutracêuticas amplamente comercializada em diversos países. O Brasil é um dos maiores importadores de alho do mundo, apesar da sua produção ser restrita e limitada ao consumo interno. Assim, explorar a diversidade genética do alho comercial conservado em bancos de germoplasma é essencial para fornecer informações genéticas adicionais acerca dessa cultura economicamente importante. Uma ferramenta adequada para esse fim é a caracterização citogenética desses acessos. Este estudo teve como objetivo caracterizar a diversidade citogenética entre sete acessos de alho de um Banco de Germoplasma no Brasil. Os cariótipos foram obtidos por coloração convencional e com os fluorocromos de cromomicina A3 (CMA) e 4,6-diamidino-2-fenilindol (DAPI). Todos os acessos analisados apresentaram número cromossômico 2n = 16, fórmula cariotípica 6M + 2SM, cariótipos simétricos, núcleos reticulados em intérfase e cromossomos com condensação uniforme da cromatina da prófase para a metáfase. A coloração com fluorocromos mostrou diferenças na quantidade e distribuição de heterocromatina ao longo dos cromossomos e entre os acessos estudados. Com base no padrão de distribuição desses pequenos polimorfismos, foi possível separar os sete acessos em três grupos. Também foi possível diferenciar individualmente alguns dos acessos. Um dos resultados obtidos mostrou distensão heteromórfica da região organizadora nucleolar observada nos pares dos cromossomos 6 ou 7 com características peculiares. Foi sugerido, por exemplo, que o bloco heteromórfico de heterocromatina (CMA +++ / DAPI-) no cromossomo 6 do acesso Branco Mineiro Piauí pode ser usado como um marcador para identificar esse genótipo ou pode estar associado a algum caráter de interesse econômico.

20.
Braz. j. biol ; 83: e243514, 2023. tab, graf
Article de Anglais | LILACS, VETINDEX | ID: biblio-1278560

RÉSUMÉ

Abstract Allium sativum L. is an herb of the Alliaceae family with a specific taste and aroma and medicinal and nutraceutical properties that are widely marketed in several countries. Brazil is one of the largest importers of garlic in the world, despite of its production is restricted and limited to internal consumption. Thus, explore the genetic diversity of commercial garlic conserved at germplasm banks is essential to generate additional genetic information about its economically important crop. A suitable tool for this purpose is the cytogenetic characterisation of these accessions. This study aimed to characterise the cytogenetic diversity among seven accessions of garlic from a Germplasm Bank in Brazil. The karyotypes were obtained by conventional staining and with chromomycin A3 (CMA) and 4,6-diamidino-2-phenylindole (DAPI) fluorochromes. All accessions analysed showed chromosome number 2n = 16, karyotype formula 6M+2SM, symmetrical karyotypes, reticulate interphase nuclei, and chromosomes with uniform chromatin condensation from prophase to metaphase. The fluorochromes staining showed differences in the amount and distribution of heterochromatin along the chromosomes and between accessions studied. Based on the distribution pattern of these small polymorphisms, it was possible to separate the seven accessions into three groups. It was also possible to differentiate some of the accessions individually. One of the results obtained showed a heteromorphic distension of the nucleolar organiser region observed on the chromosome pairs 6 or 7 with peculiar characteristics. It was suggested for example, that the heteromorphic block of heterochromatin (CMA+++/DAPI-) on chromosome 6 of the "Branco Mineiro Piauí" accession can be used as a marker to identify this genotype or may be associated with some character of economic interest.


Resumo Allium sativum L. é uma erva da família Alliaceae com sabor e aroma específicos e propriedades medicinais e nutracêuticas amplamente comercializada em diversos países. O Brasil é um dos maiores importadores de alho do mundo, apesar da sua produção ser restrita e limitada ao consumo interno. Assim, explorar a diversidade genética do alho comercial conservado em bancos de germoplasma é essencial para fornecer informações genéticas adicionais acerca dessa cultura economicamente importante. Uma ferramenta adequada para esse fim é a caracterização citogenética desses acessos. Este estudo teve como objetivo caracterizar a diversidade citogenética entre sete acessos de alho de um Banco de Germoplasma no Brasil. Os cariótipos foram obtidos por coloração convencional e com os fluorocromos de cromomicina A3 (CMA) e 4,6-diamidino-2-fenilindol (DAPI). Todos os acessos analisados ​​apresentaram número cromossômico 2n = 16, fórmula cariotípica 6M + 2SM, cariótipos simétricos, núcleos reticulados em intérfase e cromossomos com condensação uniforme da cromatina da prófase para a metáfase. A coloração com fluorocromos mostrou diferenças na quantidade e distribuição de heterocromatina ao longo dos cromossomos e entre os acessos estudados. Com base no padrão de distribuição desses pequenos polimorfismos, foi possível separar os sete acessos em três grupos. Também foi possível diferenciar individualmente alguns dos acessos. Um dos resultados obtidos mostrou distensão heteromórfica da região organizadora nucleolar observada nos pares dos cromossomos 6 ou 7 com características peculiares. Foi sugerido, por exemplo, que o bloco heteromórfico de heterocromatina (CMA +++ / DAPI-) no cromossomo 6 do acesso "Branco Mineiro Piauí" pode ser usado como um marcador para identificar esse genótipo ou pode estar associado a algum caráter de interesse econômico.


Sujet(s)
Ail , Brésil , Hétérochromatine/génétique , Zébrage chromosomique , Caryotype , Caryotypage
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE