Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 270
Filtre
1.
Article Dans Chinois | WPRIM | ID: wpr-1027472

Résumé

Boron neutron capture therapy is a method based on 10B (n,α) 7Li reaction to achieve malignancy treatment. Upon entry into the human body, the 10B compound carrier can selectively enriched in tumor cells and reacts with external irradiation neutrons. Because 7Li (4 μm) and α particles (7 μm) will be deposited in a cell magnitude (10 μm), the purpose of directional local killing of tumor cells and causing less harm to normal tissue can be achieved successfully. So far, boron neutron capture therapy has been clinically studied in a variety of malignant diseases, including glioblastoma multiforme, meningeoma, head and neck cancer, lung cancer, etc. In this article, the clinical research progress of boron neutron capture treatment in head and neck carcinomas was mainly introduced.

2.
Article Dans Chinois | WPRIM | ID: wpr-1027486

Résumé

Boron neutron capture therapy (BNCT) is an emerging treatment modality. BNCT is performed by injecting patients with the boron containing drugs, which has strong affinity with cancer cells. After undergoing irradiation with neutrons, the boron containing drugs can yield alpha and lithium particles, which can kill tumor cells precisely. To date, clinical studies of BNCT have been conducted in a variety of tumors, including glioblastoma multiforme, meningioma, head and neck cancer, sarcoma, malignant skin tumor, malignant melanoma and recurrent cancers, etc. With continuous construction of BNCT treatment centers around the world, this new technology will be quickly and comprehensively spread. In this article, clinical research progress in the application of BNCT for glioma treatment was reviewed.

3.
Rev. bras. entomol ; 68(1): e20230026, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1559495

Résumé

ABSTRACT Understanding aspects of insect ecology is a key component for the applicability of control methods or pest resistance management. For instance, the comprehension of insect dispersal is crucial to determining insect gene flow and the maximum distance between refuge areas in Bt (Bacillus thuringiensis) crops. But, for such studies, insects need to be marked prior to release. Seeking to refine the technique of dispersion studies of the genetic material of Spodoptera frugiperda (J.E. Smith) (Lepidoptera: Noctuidae), this study aimed to determine the efficiency of water-soluble dyes for the internal marking of S. frugiperda immatures and adults via larval feeding, with emphasis on marking the spermatophore. Rhodamine B, Methylene Blue, Ponceau, Coomassie, and Eosin-Nigrosin were added to the larval artificial diet at concentrations of 0, 100, 200, 400, 600, 800, and 1000 ppm. Mortality and duration of the larval stage as well as the efficiency of marking internal structures of larvae and adults were evaluated. Rhodamine B and Methylene Blue increased the duration of the larval period, but the former caused higher mortality. The staining of the gut, hemolymph, and imaginal discs, in the larval phase, was observed for Rhodamine B, Methylene Blue, and Coomassie dyes. However, none of the dyes were efficient for marking spermatophores. Thus, the addition of these water-soluble dyes to the larval diet of S. frugiperda can mark internal structures of the larva, but not the adult. Therefore, these dyes have limited application once they may be used only for marking larvae.

4.
Serv. soc. soc ; 147(1): e, 2024.
Article Dans Portugais | LILACS-Express | LILACS | ID: biblio-1560534

Résumé

Resumo: Este trabalho é fruto da tese de doutoramento em Serviço Social, na busca de apreender o avanço do conservadorismo no Brasil e suas inflexões na "captura" da subjetividade profissional das assistentes sociais. A amostra da pesquisa se constituiu a partir de dados coletados nos anais do XVI CBAS, os quais apontam para o avanço do conservadorismo na sociedade brasileira, e o quanto ele aprofunda fissuras na legitimidade, interpretação, incorporação e materialidade do projeto ético-político.


Abstract: This work is the result of a doctoral thesis in Social Work, in the quest to understand the advance of conservatism in Brazil and its inflections in the "capture" of the professional subjectivity of Social Workers. The research sample was made up of data collected in the annals of the XVI CBAS, which point to the advancement of conservatism in Brazilian society, and how it deepens fissures in the legitimacy, interpretation, incorporation and materiality of the ethical-political project.

5.
Rev. bras. med. esporte ; 30: e2021_0547, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1515070

Résumé

ABSTRACT Introduction: The assessment of biomechanical changes related to the lower limbs is necessary in clinical practice to measure the potential risks of injury and the influences on existing dysfunction. Biomechanical changes related to previous ankle injuries are known to influence the performance of the entire lower limb. Objective: The aim of this study was to correlate muscle strength tests, performance tests and ankle stability with the Single Hop Test (SHT). Methods: 82 amateur runners were evaluated with isokinetic tests of quadriceps and hamstring muscle strength, as well as Y Balance Test (YBT), Weight-bearing Lung Test (WBLT), and the SHT. Results: The results showed there was a significant correlation between the SHT and the YBT in subjects with hamstring/quadriceps ratio (I/Q ratio) <0.55, and the length of the unilateral SHT with the peak torque of ipsilateral knee extensors. Conclusion: The study was successful in correlating the functional tests in question with the results obtained in isokinetic dynamometry. Level of Evidence V; Cross-Sectional Study.


RESUMEN Introducción: La evaluación de los cambios biomecánicos relacionados con las extremidades inferiores es necesaria en la práctica clínica para medir los riesgos potenciales de lesión y las influencias sobre la disfunción existente. Se sabe que los cambios biomecánicos relacionados con lesiones previas de tobillo influyen en el rendimiento de toda la extremidad inferior. Objetivo: Correlacionar las pruebas de fuerza muscular, las pruebas de rendimiento y la estabilidad del tobillo con la prueba de salto simple (Single Hop Test, SHT). Métodos: Se evaluó a 82 corredores aficionados con pruebas isocinéticas de fuerza muscular de cuádriceps e isquiotibiales, además de pruebas como Y Balance Test (YBT), Weight-bearing Lung Test (WBLT) y la prueba SHT. Resultados: Los resultados mostraron que existía una correlación significativa entre el SHT y el YBT en sujetos con ratio isquiotibiales/cuádriceps (ratio I/Q) <0,55, y la longitud del SHT unilateral con el par máximo de los extensores de la rodilla ipsilateral. Conclusión: El estudio logró correlacionar las pruebas funcionales en cuestión con los resultados obtenidos en la dinamometría isocinética. Nivel de Evidencia V; Estudio Transversal.


RESUMO Introdução: A avaliação de alterações biomecânicas relacionadas aos membros inferiores é necessária na prática clínica para mensurar os riscos potenciais de alguma lesão e as influencias sobre uma disfunção existente. As alterações biomecânicas relacionadas a lesões prévias de tornozelo são conhecidas pela influência na performance de todo o membro inferior. Objetivo: Correlacionar testes de força muscular, testes de performance e estabilidade do tornozelo com o teste de salto simples (Single Hop Test - SHT). Métodos: Foram avaliados 82 corredores amadores com testes isocinéticos de força muscular de quadríceps e isquiotibiais, além de testes Y Balance Test (YBT), Weight-bearing Lung Test (WBLT), e o SHT. Resultados: Os resultados demonstraram haver correlação significativa entre o SHT e o YBT nos indivíduos com relação Isquiotibiais/Quadríceps (relação I/Q) <0,55, e o comprimento do SHT unilateral com o pico de torque de extensores de joelho ipsilateral. Conclusão: O estudo foi bem sucedido em correlacionar os testes funcionais em questão com os resultados obtidos na dinamometria isocinética. Nível de Evidência V; Estudo Transversal.

6.
Article Dans Chinois | WPRIM | ID: wpr-1027350

Résumé

Boron neutron capture therapy(BNCT), a promising radiotherapy, belongs to precision treatment for cancers. BNCT can accurately kill cancer cells and protect normal cells at the same time relying on 10B compounds with high efficacy. The research about developing new 10B compounds is in progress, and novel and efficient 10B compounds are emerging, which greatly facilitate broadening the advantages and efficacy of BNCT. Considering the mixed rays generated from the BNCT process, its biological effects on tumor cells are relatively complex, and related studies are still lacking. The molecular mechanisms underlying BNCT need to be elucidated further. BNCT has been applied in the treatment of malignant brain tumors, head and neck cancers, and malignant melanoma with favorable curative effects. This review mainly focuses on the development of 10B compounds, biological mechanisms, potential advantages, and clinical applications.

7.
Article Dans Chinois | WPRIM | ID: wpr-1027425

Résumé

Boron neutron capture therapy (BNCT) is an advanced method of precision radiotherapy for tumors. In BNCT, 10B enriched boron carriers enter and gather within tumor cells, then a thermal neutron beam triggers the 10B (n, α) 7Li reaction to release alpha and 7Li particle with low energy, which can kill tumor cells. Compared with conventional radiotherapy, BNCT has the characteristics of higher biological effect, more precise targeting, less damage to normal tissues and less treatment times. In this article, recent progress and existing problems of BNCT-related clinical research were reviewed.

8.
Chinese Journal of Orthopaedics ; (12): 1555-1561, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1027667

Résumé

Objective:To explore the effect of hip arthroscopy on improving the cross-sectional kinematics of the lower limbs in patients with femoral acetabular impingement (FAI).Methods:Eight FAI patients who underwent hip arthroscopy in the Department of Sports Medicine of Peking University Third Hospital from October 2021 to February 2022 were prospectively included, including 3 males and 5 females, with an age of 35.3±13.0 years (range 17-53 years), height of 168.0±12.8 cm (range 154-192 cm), weight of 61.1±8.5 kg (range 52-74 kg) and body mass index of 21.7±2.6 kg/m 2 (range 17.6-24.5 kg/m 2). There were 3 left hips and 5 right hips. FADIR (flexion, adduction and internal rotation test) was positive in all patients and FABER (flexion, abduction and external rotation test) was positive in 4 patients. Modified Harris hip score (mHHS) and visual analogue scale (VAS) of the affected hip joint were compared before the surgery and at the follow-up of 10 months. By using a markerless motion capture system, foot progression angles during normal gait, double-leg squat, forward lunge, single-leg standing and stepping in place were measured and compared before the surgery and at the follow-up of 10 months postoperative results. Results:All the 8 patients underwent the surgery successfully and were followed up for 11.0±1.2 months. The mHHS scores before the surgery and at the follow-up of 10 months were 60.9±20.5 vs. 82.9±7.3 with significant difference ( t=-3.07, P=0.018). The iHOT-12 scores before the surgery and at the follow-up of 10 months for the affected hips were 51.4±23.7 vs. 79.2±14.6 with significant difference ( t=-3.76, P=0.007). The VAS scores before the surgery and at the follow-up of 10 months were 4.6±2.3 vs. 1.5±0.9 with significant difference ( t=3.16, P=0.016). There was no significant difference in foot progression angle between the healthy side and the affected side for all movement trials before the surgery and at the follow-up of 10 months ( P>0.05). During normal gait, the postoperative and preoperative foot progression angles for the healthy side and the affected side were 26.52°±5.97 vs. 34.4°±7.20° and 24.41°±3.70° vs. 30.80°±6.43°with significant reduction ( t=2.83, P=0.013; t=3.05, P=0.041). While there was no significant difference in foot progression angles for double-leg squat, forward lunge, single-leg standing and stepping in place before the surgery and at the follow-up of 10 months ( P>0.05). Conclusion:Hip arthroscopy can change the cross-sectional kinematic characteristics of the lower limbs, potentially improving the progression angle in FAI patients.

9.
Article Dans Chinois | WPRIM | ID: wpr-993078

Résumé

To summarize the progress in BNCT dose verification method in the world and discusses their development prospects. Boron neutron capture therapy (BNCT) utilizes the specific capture reaction between the neutrons and boron drugs enriched in tumor cells to selectively kill tumor cells. In order to verify the accuracy of the radiotherapy plan and ensure the therapeutic effect on patients, it is necessary to measure the dose before treatment and compare the experimental radiation dose with the planned dose. The current BNCT dose measurement method mainly include point dose measurement method based on ionization chambers, thermoluminescence dosimeters and activation foils, two-dimensional dose measurement method based on films, and three-dimensional dose measurement method based on gel dosimeters.

10.
Article Dans Chinois | WPRIM | ID: wpr-993133

Résumé

Objective:To provide reference for establishing the testing method for quality control of neutron beam in boron neutron capture therapy (BNCT) equipment in China by testing the radiation characteristic parameters and dosimetry characteristic parameters of epithermal neutron beam in hospital neutron irradiator (IHNI).Methods:By comparing the uncertainties in the result of various test items with the deviation values recommended by the European Joint Research Center (EC-JRC), the feasibility of the relevant of testing method was analyzed and evaluated.Results:The uncertainty in epithermal neutron fluence rate was 2.7%. The uncertainty in ratio of thermal to epithermal neutron fluence rate was 3.1%. The uncertainty in ratio of fast neutron air kerma to epithermal neutron fluence rate was 9.3%. The uncertainty in ratio of gamma air kerma to epithermal neutron fluence rate was 8.7%. The uncertainty in spatial distribution of neutron fluence rate was 2.7%. The uncertainty in thermal neutron fluence rate in phantom was 1.8%. The uncertainty in neutron and gamma-ray dose rate in phantom was 17.1% and 4.0%, respectively.Conclusions:The uncertainty in neutron dose rate measurement result in phantom is higher, and further research is needed to improve the accuracy of the testing method. The uncertainty in the measurement result of other test items is lower, and the accuracy of the test result is expected to meet the allowable deviation value recommended by the European Joint Research Center, and the test method is feasible.

11.
Article Dans Chinois | WPRIM | ID: wpr-995747

Résumé

The amount of circulating tumor cells(CTC) in peripheral blood is very small, which is difficult to isolate. Microfluidic chips are becoming a hot area in recent years because of their portability, high sensitivity, high capture,and low cost. Microfluidic devices have been shown to maintain optimal performance for CTC isolation capture, including flux, purity, recovery, and clinical relevance. However, microfluidic technology is still unable to recover CTC with high recovery and purity.

12.
Journal of Leukemia & Lymphoma ; (12): 147-152, 2023.
Article Dans Chinois | WPRIM | ID: wpr-988965

Résumé

Objective:To investigate the differences among targeted capture high depth sequencing (Panel-seq), transcriptome sequencing (RNA-seq) and traditional detection methods in cytogenetic and molecular genetic typing of childhood B-cell acute lymphoblastic leukemia (B-ALL) and their significances.Methods:The clinical data of 152 newly diagnosed childhood B-ALL cases in Guangzhou Women and Children's Medical Center from September 2020 to December 2021 were retrospectively analyzed. Along with traditional cytogenetic and molecular detection methods including karyotyping, fluorescence in situ hybridization (FISH) and 43 kinds of fusion gene quantitative screening for traditional cells and molecular genetic detection, both Panel-seq and RNA-seq were also performed. Panel-seq covered more than 600 genes with common mutations in hematological tumors, from which fusion genes and gene mutations were both analyzed. RNA-seq was used to analyze fusion genes, gene mutations, gene expression, and copy number variation at the chromosome level. High hyperdiploid karyotype was estimated by using gene expression profile clustering and copy number variations. The cytogenetic typing results of all detection methods were also analyzed.Results:Among 152 patients, 93 cases were males and 59 cases were females, with the median age of 4.0 years (0.8-13.0 years). The median blast cell ratio was 0.855 (0.215-0.965). The traditional detection methods could identify 4 cases (2.6%) with BCR-ABL1, 2 cases (1.3%) with CRLF2 gene-related fusion, 27 cases (17.8%) with ETV6-RUNX1, 1 case (0.7%) with iAMP21, 5 cases (3.3%) with MLL rearrangement, 8 cases (5.3%) with TCF3-PBX1 and 22 cases (14.5%) with high hyperdiploid karyotype. Panel-seq could identify 4 cases (2.6%) with BCR-ABL1, 2 cases (1.3%) with CRLF2 gene-related fusions, 27 cases (17.8%) with ETV6-RUNX1, 3 cases (2.0%) with MEF2D gene-related fusions, 1 case (0.7%) with MEIS1-FOXO1, 5 cases (3.3%) with MLL rearrangement, 5 cases (3.3%) with PAX5 gene-related fusions, 8 cases (5.3%) with TCF3-PBX1 fusions, 4 cases (2.6%) with ZNF384 gene-related fusions, and 2 cases (1.3%) with IKZF1 N159Y mutations. Among 152 patients, 1 case with MLL rearrangement didn't receive RNA-seq detection because of sample quality; in other 151 B-ALL cases, 1 case (0.7%) with ACIN1-NUTM1, 4 cases (2.6%) with BCR-ABL1, 3 cases (2.0%) with CRLF2 gene-related fusions, 8 cases (5.3%) with DUX4 gene-related fusions, 27 cases (17.9%) with ETV6-RUNX1, 3 cases (2.0%) with MEF2D gene-related fusions, 1 case (0.7%) with MEIS1-FOXO1, 4 cases (2.6%) with MLL rearrangement, 5 cases (3.3%) with PAX5 gene-related fusions, 1 case (0.7%) with ZMIZ1-ABL1, 8 cases (5.3%) with TCF3-PBX1,4 cases (2.6%) with ZNF384 gene-related fusions, 61 cases (40.4%) with hyperdiploid karyotypes, and 2 cases (1.3%) with IKZF1 N159Y mutations were detected; RNA-seq had obvious advantage in detecting fusion gene and hyperdiploid karyotype. The cytogenetic and molecular genetic typing rates of traditional method, Panel-seq and RNA-seq were 45.4% (69/152), 40.1% (61/152) and 87.4% (132/151), respectively. The combination of the three could identify 89.5% (136/152) of childhood B-ALL patients.Conclusions:The combination of Panel-seq and RNA-seq can increase the detection rate of genetic abnormality in childhood B-ALL, which provides a more accurate molecular genetic classification for B-ALL and the basis for treatment guideline and prognosis judgement.

13.
Article Dans Japonais | WPRIM | ID: wpr-966096

Résumé

We report the case of a 76-year-old man who developed type IA endoleak through the fenestration after 1-debranch TEVAR using a Najuta endograft. The patient was admitted with expansion of the aneurysm after TEVAR, for additional therapy. Type IA endoleak through a fenestration has remained a significant clinical concern and its treatment is challenging. We performed Zone 0 TEVAR using the “Squid-Capture” technique assisted in situ stent-graft fenestration. Cerebral vessels were perfused by a percutaneous cardiopulmonary support system during in situ stent-graft fenestration, and the cerebral branch was clamped at the proximal site. It is difficult to operate the catheter inside the endoskeleton structure of a Najuta endograft, but several innovations were effective. Test dilation of the balloon catheter was performed to ensure that the wire did not interfere with the endoskeleton. Avoiding interference with the endoskeleton is important. The Squid-Capture technique allows safe and secure puncture of the graft. The operation was completed successfully. After this procedure, the endoleak disappeared. It is considered to be a useful method for treatment of endoleak through the fenestration.

14.
Acta Pharmaceutica Sinica B ; (6): 3892-3905, 2023.
Article Dans Anglais | WPRIM | ID: wpr-1011155

Résumé

Activating humoral and cellular immunity in lymph nodes (LNs) of nanoparticle-based vaccines is critical to controlling tumors. However, how the physical properties of nanovaccine carriers orchestrate antigen capture, lymphatic delivery, antigen presentation and immune response in LNs is largely unclear. Here, we manufactured gold nanoparticles (AuNPs) with the same size but different shapes (cages, rods, and stars), and loaded tumor antigen as nanovaccines to explore their disparate characters on above four areas. Results revealed that star-shaped AuNPs captured and retained more repetitive antigen epitopes. On lymphatic delivery, both rods and star-shaped nanovaccines mainly drain into the LN follicles region while cage-shaped showed stronger paracortex retention. A surprising finding is that the star-shaped nanovaccines elicited potent humoral immunity, which is mediated by CD4+ T helper cell and follicle B cell cooperation significantly preventing tumor growth in the prophylactic study. Interestingly, cage-shaped nanovaccines preferentially presented peptide-MHC I complexes to evoke robust CD8+ T cell immunity and showed the strongest therapeutic efficacy when combined with the PD-1 checkpoint inhibitor in established tumor study. These results highlight the importance of nanoparticle shape on antigen delivery and presentation for immune response in LNs, and our findings support the notion that different design strategies are required for prophylactic and therapeutic vaccines.

15.
Chinese Journal of Oncology ; (12): 402-409, 2023.
Article Dans Chinois | WPRIM | ID: wpr-984736

Résumé

Objective: To study the diagnostic value of different detection markers in histological categories of endocervical adenocarcinoma (ECA), and their assessment of patient prognosis. Methods: A retrospective study of 54 patients with ECA in the Cancer Hospital, Chinese Academy of Medical Sciences from 2005-2010 were performed. The cases of ECA were classified into two categories, namely human papillomavirus-associated adenocarcinoma (HPVA) and non-human papillomavirus-associated adenocarcinoma (NHPVA), based on the 2018 international endocervical adenocarcinoma criteria and classification (IECC). To detect HR-HPV DNA and HR-HPV E6/E7 mRNA in all patients, we used whole tissue section PCR (WTS-PCR) and HPV E6/E7 mRNA in situ hybridization (ISH) techniques, respectively. Additionally, we performed Laser microdissection PCR (LCM-PCR) on 15 randomly selected HR-HPV DNA-positive cases to confirm the accuracy of the above two assays in identifying ECA lesions. Receiver operating characteristic (ROC) curves were used to analyze the efficacy of markers to identify HPVA and NHPVA. Univariate and multifactorial Cox proportional risk model regression analyses were performed for factors influencing ECA patients' prognoses. Results: Of the 54 patients with ECA, 30 were HPVA and 24 were NHPVA. A total of 96.7% (29/30) of HPVA patients were positive for HR-HPV DNA and 63.3% (19/30) for HR-HPV E6/E7 mRNA, and 33.3% (8/24) of NHPVA patients were positive for HR-HPV DNA and HR-HPV E6/E7 mRNA was not detected (0/24), and the differences were statistically significant (P<0.001). LCM-PCR showed that five patients were positive for HR-HPV DNA in the area of glandular epithelial lesions and others were negative, which was in good agreement with the E6/E7 mRNA ISH assay (Kappa=0.842, P=0.001). Analysis of the ROC results showed that the AUC of HR-HPV DNA, HR-HPV E6/E7 mRNA, and p16 to identify HPVA and NHPVA were 0.817, 0.817, and 0.692, respectively, with sensitivities of 96.7%, 63.3%, and 80.0% and specificities of 66.7%, 100.0%, and 58.3%, respectively. HR-HPV DNA identified HPVA and NHPVA with higher AUC than p16 (P=0.044). The difference in survival rates between HR-HPV DNA (WTS-PCR assay) positive and negative patients was not statistically significant (P=0.156), while the difference in survival rates between HR-HPV E6/E7 mRNA positive and negative patients, and p16 positive and negative patients were statistically significant (both P<0.05). Multifactorial Cox regression analysis showed that International Federation of Obstetrics and Gynecology (FIGO) staging (HR=19.875, 95% CI: 1.526-258.833) and parametrial involvement (HR=14.032, 95% CI: 1.281-153.761) were independent factors influencing the prognosis of patients with ECA. Conclusions: HR-HPV E6/E7 mRNA is more reflective of HPV infection in ECA tissue. The efficacy of HR-HPV E6/E7 mRNA and HR-HPV DNA (WTS-PCR assay) in identifying HPVA and NHPVA is similar, with higher sensitivity of HR-HPV DNA and higher specificity of HR-HPV E6/E7 mRNA. HR-HPV DNA is more effective than p16 in identifying HPVA and NHPVA. HPV E6/E7 mRNA and p16 positive ECA patients have better survival rates than negative.


Sujets)
Femelle , Humains , Infections à papillomavirus/diagnostic , Études rétrospectives , Tumeurs du col de l'utérus/anatomopathologie , Pronostic , Protéines des oncogènes viraux/génétique , Papillomaviridae , Adénocarcinome/anatomopathologie , ARN messager/génétique , Papillomaviridae/génétique , ARN viral/génétique
16.
Article Dans Chinois | WPRIM | ID: wpr-981739

Résumé

The shoulder joint is the most flexible joint in the body with the largest range of motion, and the movement pattern is more complex. Accurate capture of three-dimensional motion data of the shoulder joint is crucial for biomechanical evaluation. Optical motion capture systems offer a non-invasive and radiation-free method to capture shoulder joint motion data during complex movements, enabling further biomechanical analysis of the shoulder joint. This review provides a comprehensive overview of optical motion capture technology in the context of shoulder joint movement, including measurement principles, data processing methods to reduce artifacts from skin and soft tissues, factors influencing measurement results, and applications in shoulder joint disorders.


Sujets)
Humains , Épaule , , Phénomènes biomécaniques , Membre supérieur , Articulation glénohumérale , Mouvement , Amplitude articulaire
17.
Indian J Ophthalmol ; 2022 Dec; 70(12): 4312-4318
Article | IMSEAR | ID: sea-224740

Résumé

Purpose: To study the use of sulcus placement of a 3?piece intraocular lens (IOL) with optic capture in patients with exfoliation with zonular weakness. Methods: Data on all exfoliation patients who had direct or indirect evidence of zonular weakness and had a 3?piece IOL implanted in the sulcus with optic capture over a 5?year period between January 2017 and January 2022 were included in this retrospective case series. Results: The study comprised of 35 eyes of 35 patients. The mean age at surgery of the 20 male and 13 female patients was 75.21 years ± 5.74 (standard deviation (SD)). The mean pupillary diameter was 5.77 ± 2.23 mm (range: 10 to 3 mm). A capsular tension ring (CTR) was used in 17 cases and iris hooks as a pupil?expanding device were used in 15 cases. No patients had an increase in inflammation after surgery and there were no late subluxation or dislocation of “in the bag” posterior chamber IOL or major complications. There was a significant improvement in visual acuity. Conclusion: The sulcus placement of 3?piece IOL with optic capture is the ideal technique in patients with clinical or intraoperative evidence of mild to moderate zonular weakness. It may also be more appropriate in relatively younger patients (in the fifties or sixties) with exfoliation with no overt zonulopathy to prevent late subluxation or dislocation of “in the bag” IOL

18.
Rev. biol. trop ; 70(1)dic. 2022.
Article Dans Espagnol | LILACS, SaludCR | ID: biblio-1387700

Résumé

Resumen Introducción: Tradicionalmente, los estudios de escarabajos coprófagos en los bosques secos tropicales (BST) del Caribe colombiano han aplicado metodologías diseñadas para zonas húmedas y andinas del país, lo cual podría estar incidiendo en el rendimiento y la eficiencia del muestreo. Objetivo: Con el fin de aportar a esta discusión, se analizó cómo la cantidad de cebo y el tiempo de operación de la trampa de caída inciden en la efectividad de captura de escarabajos coprófagos en un fragmento de BST en La Reserva Campesina la Flecha, San Jacinto, Colombia. Métodos: Para la captura de los escarabajos, se utilizó trampas de caída, cebadas con tres cantidades diferentes de atrayente: pequeño (34.6 g), mediano (53.8 g) y grande (114.9 g), las cuales permanecieron activas en campo durante 48 h. Cuatro muestreos fueron realizados entre marzo y septiembre de 2015, abarcando por igual la época seca y de lluvia. Resultados: Se registró un total de 4 563 individuos, agrupados en 10 géneros y 27 especies de escarabajos coprófagos. Los mayores valores de riqueza, abundancia y biomasa se presentaron en el cebo grande, a las 48 h, durante la época de lluvias. Sin embargo, el tiempo de operación de la trampa no tuvo efecto en la estimación de la riqueza, abundancia y biomasa de escarabajos independientemente de los tamaños de cebo. Los tres órdenes de la diversidad ( 0 D, 1 D y 2 D), presentaron valores similares entre las cantidades de cebo durante la época de lluvia, pero en la época seca, los cebos de mayor tamaño presentaron los valores de diversidad más altos. Por su parte con el cebo de mayor tamaño se capturó significativamente más riqueza, abundancia y biomasa de escarabajos de cuerpo pequeño y grande siendo esta situación más notaria durante la época seca. Conclusiones: Los resultados de este trabajo evidencian que para el estudio de los ensamblajes de escarabajos en el BST la utilización de un cebo de mayor tamaño contribuye a una mejor estimación de riqueza, abundancia, diversidad y biomasa, sobre todo durante la época seca, cuando las condiciones ambientales propician que los cebos pierdan su atractividad con mayor rapidez.


Abstract Introduction: Typically, research on dung beetles in the Tropical Dry Forests (TDF) of Colombian Caribbean region, have applied methodologies designed for wet or Andean areas of the country, which could be influencing the performance and efficiency of sampling. Objective: In order to contribute to this discussion, we analyzed how the bait amount and pitfall trap operating time influence the collection effectiveness of dung beetles in a TDF fragment at Reserva Campesina La Flecha, San Jacinto, Colombia. Methods: For the collection of beetles, we utilized pitfall traps baited with three different amounts of attractants: small (34.6 g), medium (53.8 g), and large (114.9 g), which remained active in the field for 48 h., 4 samplings between March and September 2015 were carried out, covering both, dry and rainy seasons. Results: A total of 4 563 individuals were recorded, grouped into 10 genera and 27 species of dung beetles. The highest values of richness, abundance and biomass were registered in the large bait, at 48 h, during the rainy season. However, the trap operating time had no effect on the estimation of beetles' richness, abundance, and biomass, regardless of bait sizes. The three diversity orders ( 0 D, 1 D y 2 D) showed similar values between the bait amounts during rainy season, but in the dry season, the largest baits displayed the highest diversity values. On the other hand, with the largest bait, significantly more richness, abundance, and biomass of small and large body beetles were registered, especially during the dry season. Conclusions: The results of this research show that, for the study of beetles' assemblages in the BST, the use of a larger bait contributes to a better estimate of richness, abundance, diversity and biomass, especially during the dry season, when environmental conditions promote a more rapidly loss of baits attractiveness.


Sujets)
Animaux , Coléoptères , Biomasse , Études par échantillonnage
19.
Indian J Ophthalmol ; 2022 Jan; 70(1): 293-295
Article | IMSEAR | ID: sea-224103

Résumé

We describe the technique of posterior optic capture without anterior vitrectomy in two difficult cases of pediatric cataract. We demonstrate how a three?piece foldable intraocular lens can be maneuvered behind the posterior capsule after an improvised posterior capsulotomy. This technique provided excellent intraocular lens (IOL) stability with the absence of lens epithelial cell proliferation in infants with altered posterior capsule morphology

20.
Article Dans Chinois | WPRIM | ID: wpr-995816

Résumé

Objective:To provide a reference for the choice of electronic data capture system used in clinical research, the function and performance of some tool software were expounded and compared.Methods:We selected three freely available systems of REDCap, Commcare, and OpenEDC as research objects, describing and comparing their user license acquisition path, data capture related functions, and information security assurance measures. This article reflected how the three kinds of tool software ensure research data privacy and scientificity, and presented the consideration of system security and accessibility.Results:REDCap was the most mature system of the three, which had a fairly comprehensive design in functional integrity, data security, user friendliness, and system scalability. Commcare system featured in the mobile collection, and supported the most abundant types of collected data, while OpenEDC was characteristic of low threshold and flexible deployment.Conclusions:REDCap system is widely applicable to small and medium scale medical research, including clinical trials, retrospective studies, cohort studies, and translational research. Commcare system is the preferred option for medical investigations represented by epidemiologic surveys, while OpenEDC is particularly suitable for investigator initiated studies.

SÉLECTION CITATIONS
Détails de la recherche