Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtre
Ajouter des filtres








Gamme d'année
1.
Rev. cuba. oftalmol ; 33(1): e831, ene.-mar. 2020. tab
Article Dans Espagnol | LILACS, CUMED | ID: biblio-1126719

Résumé

RESUMEN Objetivo: Determinar las características del endotelio corneal mediante microscopia endotelial. Métodos: Se realizó un estudio descriptivo y retrospectivo en córneas donantes del banco de ojos del Instituto Cubano de Oftalmología "Ramón Pando Ferrer" en el período de enero a junio del año 2019. La muestra estuvo conformada por 224 córneas donantes. Las variables del estudio fueron: edad, cirugías previas, gerontoxón, pterigion, defectos epiteliales, infiltrado corneal, opacidad corneal, edema, pigmentos endoteliales, guttas, desprendimiento de la Descemet, densidad celular, hexagonalidad y polimegatismo. Resultados: El gerontoxon fue el hallazgo más frecuente (56,69 por ciento); la densidad celular media fue de 2 501 cel/mm2; el coeficiente de variación medio fue 43,32 y la hexagonalidad media 50,02. La densidad celular endotelial entre 2 000 y 2 500 cel/mm2 fue más frecuente entre 60 y 79 años de edad (76,72 por ciento), mientras que entre 20 y 29 años todas las córneas donantes presentaron una densidad endotelial mayor de 2 500 cel/mm2. Conclusiones: En el examen biomicroscópico de la córnea donante fue más frecuente el gerontoxon. Por microscopia endotelial la mayoría de las córneas fueron aptas para trasplante corneal. Un endotelio corneal con densidad celular mayor de 2 500 cel/mm2 no es exclusivo de córneas con menos de 60 años de edad(AU)


ABSTRACT Objective: Determine the characteristics of the corneal endothelium by endothelial microscopy. Methods: A retrospective descriptive study was conducted of donor corneas from the eye bank of Ramón Pando Ferrer Cuban Institute of Ophthalmology from January to June 2019. The sample was 224 donor corneas. The variables analyzed were age, previous surgery, gerontoxon, pterygium, epithelial defects, corneal infiltrate, corneal opacity, edema, endothelial pigments, guttae, Descemet's membrane detachment, cell density, hexagonality and polymegethism. Results: Gerontoxon was the most common finding (56.69 percent), mean cell density was 2 501 cell/mm2, mean variation coefficient was 43.32 and mean hexagonality was 50.02. Endothelial cell density from 2 000 to 2 500 cell/mm2 was more common in the 60-79 years age group (76.72 percent), whereas in the 20-29 years age group all the donor corneas had an endothelial density above 2 500 cell/mm2. Conclusions: Gerontoxon was the most common finding in the biomicroscopic examination of the cornea. Endothelial microscopy found that most corneas were suitable for corneal transplantation. A corneal endothelium with a cell density above 2 500 cell/mm2 is not exclusive of corneas under 60 years of age(AU)


Sujets)
Humains , Transplantation de cornée/effets indésirables , Banques des yeux/éthique , Microscopie/méthodes , Numération cellulaire/tendances , Épidémiologie Descriptive , Études rétrospectives , Cellules endothéliales/anatomopathologie , Sélection de donneurs/méthodes
SÉLECTION CITATIONS
Détails de la recherche