Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtre
Ajouter des filtres








Gamme d'année
1.
International Eye Science ; (12): 106-110, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1003516

Résumé

AIM: To compare the short-term postoperative visual acuity, visual disturbance phenomena, and spectacle independence rate in patients who underwent monocular implantation with trifocal, multifocal, or extended range of vision intraocular lens(IOL).METHODS: A retrospective analysis was conducted on 67 cataract patients(67 eyes)who underwent phacoemulsification cataract extraction combined with IOL implantation from March 2019 to December 2022. A total of 35 cases(35 eyes)received Symfony extended range of vision IOL implantation, 21 cases(21 eyes)received AcrySof IQ ReSTOR +3D multifocal IOL, and 11 cases(11 eyes)received AcrySof IQ PanOptix trifocal IOL. The preoperative uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA), and uncorrected near visual acuity(UNVA)and 3 mo postoperatively were documented. Moreover, defocus curves, visual disturbance phenomena, and spectacle independence rates were recorded at 3 mo postoperatively.RESULTS: At 3 mo postoperatively, no statistically significant differences were observed in UDVA among the three groups(P>0.05). A comparison of UIVA showed superior results in the Symfony and PanOptix groups compared to the ReSTOR group(all P<0.01). The UNVA of both the ReSTOR and PanOptix groups outperformed the Symfony group(all P<0.01). The defocus curves indicated that in the intermediate vision range(-1.00 to -1.50 D), the Symfony group exhibited better performance than the ReSTOR group(P<0.05); while in the near vision range(-2.50 to -3.50 D), the ReSTOR group was superior to the Symfony group(P<0.05). The PanOptix group demonstrated superior visual acuity in the near vision range(-2.00 to -3.50 D)compared to the Symfony group(P<0.05)and was also superior in the intermediate vision range(-1.00 to -2.00 D)compared to the ReSTOR group(P<0.05). No significant differences were observed in the incidence of glare or halo and binocular interference phenomena among the three groups(P>0.05). The PanOptix and ReSTOR groups exhibited a higher spectacle independence rate compared to the Symfony group(P<0.0167).CONCLUSION: Compared to Symfony extended range of vision IOL and ReSTOR multifocal IOL, PanOptix trifocal IOL offers a balanced approach to distance, intermediate, and near visual acuity, without a high incidence of glare and halo, and with a higher spectacle independence rate. Caution is still advised when considering monocular implantation with presbyopia-correcting IOLs.

2.
International Eye Science ; (12): 312-315, 2023.
Article Dans Chinois | WPRIM | ID: wpr-960957

Résumé

AIM: To evaluate the clinical efficacy of femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation.METHODS:The retrospective study enrolled 22 cases(26 eyes)of cataract patients who underwent femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation from August 2020 to August 2021. Follow-up to 3mo after surgery, the changes of far, intermediate and near visual acuity, aberration, Strehl ratio(SR)and modulation transfer function cutoff(MTF-cutoff)frequency were compared. Defocus curve at 1mo postoperatively was made, and the visual quality and satisfaction were evaluated after 3mo of surgery.RESULTS: The visual acuity of all patients was better than 0.1(LogMAR)at the far, intermediate and near distance at 1d, 1wk, 1 and 3mo postoperatively, and it was significantly improved compared with those before surgery(all P<0.01). The defocus curve transitioned smoothly between +0.5 and -3.0D at 1mo after surgery, and visual acuity was better than 0.63. The total aberration and spherical aberration in the whole eye were significantly lower after surgery than before, and the SR and MTF-cutoff were significantly improved at 1d and 1wk after surgery(all P<0.05). With high satisfaction and good visual quality, patients could watch at far, intermediate and near distance without wearing glasses at 3mo after surgery.CONCLUSION: Femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation gave patients a comfortable and satisfactory full-course vision.

3.
Indian J Ophthalmol ; 2022 Aug; 70(8): 2867-2871
Article | IMSEAR | ID: sea-224555

Résumé

Purpose: To compare four different types of intra ocular lenses (IOLs), namely, AT LISA, Eyecryl SERT trifocal, Eyhance, Eyecryl SERT extended depth of focus (EDOF) with respect to their clinical outcomes. Methods: This is a retrospective comparative study in which patients who underwent surgery and one of the four types of IOL were implanted. Postoperative evaluation was recorded at one month, postoperatively. The monocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (6 m), uncorrected intermediate visual acuity (UIVA) (60 cm), distance-corrected intermediate visual acuity (CIVA), uncorrected near visual acuity (UNVA) (40 cm), and corrected near visual acuity (CNVA) were assessed postoperatively on post operative day 30, for all four IOL groups. Defocus curve and contrast sensitivity were also compared. Results: With regards to UDVA and CDVA, P value was not statistically significant. (P = 0.534 and 0.421, respectively). EDOF group of IOLs had statistically significant better UIVA and CIVA than trifocal IOL group. (P < 0.001, 0.012, <0.001) and EDOF group had statistically significant worse P value pertaining to UNVA and CNVA (P < 0.001, 0.070, <0.001, 0.190). Pertaining to contrast sensitivity, EDOF group had better contrast sensitivity than Trifocal IOL group (P < 0.001). Conclusion: All four IOLs compared in this study had good comparable distant visual acuity. Near visual acuity was better with AT LISA and Eyecryl SERT trifocal IOL while intermediate vision was better with Eyhance and Eyecryl SERT EDOF IOL. Contrast sensitivity was better in EDOF IOLs than in both trifocal IOLs

4.
International Eye Science ; (12): 1166-1169, 2021.
Article Dans Chinois | WPRIM | ID: wpr-877373

Résumé

@#AIM: To evaluate the visual quality between the Tecnis Symfony extended depth of focus intraocular lens(IOL)and Zeiss trifocal IOL(At Lisa tri 839 MP)implantation.<p>METHODS: Forty-two patients(53 eyes)who underwent cataract phacomulsification with IOL implantation from Jan. 2019 to Dec. 2020 were randomly divided into group A and group B according to the type of implanted IOL. The group A with 22 patients(29 eyes)implanted the Tecnis Symfony extended depth of focus IOL, the group B with 20 patients(24 eyes)implanted Zeiss trifocal IOL. The uncorrected distance visual acuity(UDVA), uncorrected intermediate distance visual acuity(UIVA), uncorrected near distance visual acuity(UNVA), and best corrected distance visual acuity(BCVA)were measured after 3mo of surgery. The defocus curve, the quality of life and the occurrence of complications were also observed.<p>RESULTS: The visual acuity was significantly improved in both groups after 3mo of surgery. There were no significant differences in the UDVA(5m), UIVA(80cm)and BCVA(5m)between the two groups(<i>P</i>>0.05). In group B, the UIVA(60cm)and UNVA(40cm)were better than in group A(all <i>P</i><0.05). The defocus curve analysis revealed that the group A tended to be stable between +1.0D to -2.0D, and to form a platform, while the group B had double peaks(0D, -2.5D). The distance visual acuity at 0D were no significantly differences between the two groups(<i>P</i>>0.05), but the near visual acuity at -2.5D and -3.5D in group B were significantly higher than in group A(all <i>P</i><0.01). In both groups over 90% patients were spectacle independent. Patients in the two groups showed different degrees of halo, glare and other optical phenomena, but the overall satisfaction were higher. The scores of satisfactions for reading speed and night vision were significantly better in group A than in group B(all <i>P</i><0.05). <p>CONCLUSION: In both groups over 90% patients were spectacle independent, they can obtain good near,intermediate and far distance visual acuity. Symfony extended depth IOL has better continuous intermediate distance visual acuity, patients can also obtain higher satisfaction and have better night vision. The Zeiss trifocal IOL implantation is associated with significantly better near visual acuity, and it is more suitable for near vision.

5.
Journal of the Korean Ophthalmological Society ; : 153-158, 2020.
Article Dans Coréen | WPRIM | ID: wpr-811328

Résumé

PURPOSE: To determine the through-focus optical bench test performance of monofocal, bifocal, and extended depth-of-focus intraocular lenses (IOLs), and to measure their defocus curves.METHODS: A model eye was placed on an optical bench to test three different IOLs (TECNIS ZXR00, ZMB00, and ZCB00; Abbott Medical Optics, Santa Ana, CA, USA). The focus was changed by inserting trial lenses from +1.00 diopters to −4.00 diopters, in increments of +0.25 diopters. The 1951 United States Air Force Resolution chart was used to determine the quality of the images. The degree of similarity with reference images was given by the cross-correlation coefficient, and defocus curves were drawn and compared.RESULTS: Bifocal IOLs showed lower image quality with the addition of minus diopter trial lenses, but showed good image quality at near distance. Bifocal IOLs also showed a ‘double peak’ in their defocus curve. Monofocal IOLs showed a lower image quality and cross-correlation coefficient with addition of lower-diopter trial lenses. The extended depth of focus IOLs showed a single peak in their defocus curve, but had a wider range of diopters and better image quality than monofocal IOLs.CONCLUSIONS: Bifocal IOLs showed a double peak defocus curve, and extended depth of focus IOLs showed a wider diopter range and better image quality than monofocal IOLs.


Sujets)
Lentilles intraoculaires , États-Unis
6.
International Eye Science ; (12): 41-44, 2020.
Article Dans Chinois | WPRIM | ID: wpr-777792

Résumé

@#AIM: To compare the visual quality of bifocal(AT LISA 809MP)and trifocal(AT LISA tri 839MP)IOLs after implantation.<p>METHODS: Retrospective study. A total of 49 eyes of 28 patients with cataract who underwent phacoemulsification combined with multifocal IOL implantation from March 2018 to February 2019 were collected. There were 30 eyes of 18 patients in the bifocal group, aged 40-85(mean 67.08±10.80)years. The trifocal group consisted of 19 eyes of 10 patients, aged 38-79(mean 62.21±14.50)years. All patients underwent visual quality analysis system(OQAS), defocus curve and other examinations.<p>RESULTS: The near BCVA of the two focus groups was better than that of the three focus groups, and the medium UCVA and far BCVA of the three focus groups were better than those of the two focus groups(all <i>P</i><0.05). The trifocal group had better visual acuity at +1.5, -1.0, -1.5, -2, -2.5D and -3.0D defocus than the bifocal group. OQAS visual quality parameters were better in the two-focus group than in the three-focus group in OV 20%, OV 9%, and SR(all <i>P</i><0.05).<p>CONCLUSION: Both bifocal and trifocal IOL implantation can achieve good uncorrected and near visual acuity and high visual quality, while trifocal IOL can achieve better intermediate visual acuity.

7.
Journal of Medical Postgraduates ; (12): 600-604, 2014.
Article Dans Chinois | WPRIM | ID: wpr-452816

Résumé

Objective Acrysof IQ Restor multifocal toric intraocular lens ( IOL) is a new product , which allows a single sur-gical procedure for presbyopia correction and corneal astigmatism management .This study was to evaluate the early clinical effects of phacoemulsification cataract surgery with implantation of a diffractive multifocal toric IOL . Methods We retrospectively analyzed 7 cases (9 eyes) of corneal astigmatism ≥1.0 diopter (D) treated by phacoemulsification with implantation of an Acrysof IQ Restor toric IOL.The patients were followed up for 3 months for observation of uncorrected distance visual acuity ( UDVA) , best corrected distance visual acuity ( CDVA) , uncorrected near visual acuity ( UNVA ) , best corrected near visual acuity ( CNVA ) , spherical equivalent (SE) refraction, focal depth, residual astigmatism, rotational stability of the IOL, contrast sensitivity (CS), and spectacle independ-ence preoperatively and at 1 week, 1 month, and 3 months after operation . Results At 3 months after surgery , the UDVA ( log-MAR), CDVA, UNVA, and CNVA were 0.07 ±0.10, 0.02 ±0.11, 0.12 ±0.06, and 0.08 ±0.07, respectively, with an SE re-fraction within ±0.50 D of the attempted spherical correction in 8 eyes (88.9%) and a focal depth of (5.32 ±1.78) D.The residual astigmatism at 3 months was significantly reduced as compared with the baseline ([0.25 ±0.28] vs [1.55 ±0.39] D, P0.05).At 3 months, the mean IOL axis rotation was (3.11 ±1.61)°and CS was remarkably im-proved ( P0.05) except at 18.0 cpd (P<0.05). Conclusion Implantation of the Acrysof IQ Restor multifocal toric IOL provides excellent overall quality of vision, spectacle independence, visual quality, and rotational stability for patients with cataract and corneal astigmatism.

SÉLECTION CITATIONS
Détails de la recherche