Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 259
Filtrer
1.
Rev. colomb. gastroenterol ; 39(2): 230-235, Jan.-June 2024. graf
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1576321

RÉSUMÉ

Abstract Only 2% of malignant tumor lesions in the pancreas represented metastatic lesions. Endoscopic biliopancreatic ultrasonography, with the possibility of guided biopsy, is one of the main diagnostic methods currently available for lesions in the pancreas. A case of a male patient with a history of small cell carcinoma of the lung with findings of a tumor lesion in the pancreas corresponding to metastasis was described.


Resumen Tan solo el 2% de las lesiones tumorales malignas en el páncreas representan lesiones metastásicas. La ultrasonografía endoscópica biliopancreática, con posibilidad de biopsia guiada, es uno de los principales métodos diagnósticos disponibles actualmente para las lesiones en el páncreas. Se describe el caso de un paciente masculino con antecedente de carcinoma de células pequeñas de pulmón con hallazgos de lesión tumoral en el páncreas correspondiente a metástasis.

2.
Acta Medica Philippina ; : 51-56, 2024.
Article de Anglais | WPRIM | ID: wpr-1006403

RÉSUMÉ

Background and Objectives@#The benefits of rapid on-site evaluation (ROSE) of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid masses have not been convincingly shown in large, randomized trials. New equipment using EUS-guided fine needle biopsy (FNB) allows for more material to be acquired that may obviate the need for ROSE. This study aimed to evaluate if EUS-FNB without ROSE was non-inferior to EUS-FNA with ROSE in solid pancreatic masses (SPMs). @*Methods@#Patients with SPMs requiring tissue sampling were randomly assigned to undergo either EUS-FNA with ROSE or EUS-FNB without ROSE. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy and secondary endpoints were specimen quality, complication rates, and procedure time. @*Results@#Seventy-eight patients were randomized and analyzed (39 EUS-FNA with ROSE and 39 EUS-FNB without ROSE). Non-significantly different diagnostic accuracies were noted in both groups (97% with ROSE and 100% without ROSE, P < 0.371). The bloodiness of histologic samples and complication rates were not significantly different between groups. A significantly shorter mean sampling procedural time was noted for EUS-FNB over EUS-FNA with ROSE (30.4 ± 10.4 vs 35.8 ± 9.8 minutes, P < .02). @*Conclusions@#EUS-FNB demonstrated equal diagnostic accuracy with shorter procedure times in evaluating SPMs compared to EUS-FNA with ROSE. These new-generation FNB needles may obviate the need for ROSE.


Sujet(s)
Tumeurs du pancréas
3.
Article de Chinois | WPRIM | ID: wpr-1020923

RÉSUMÉ

Objective To explore the value of endoscopic ultrasonography combined with linked color imaging/blue laser imaging technology combined with magnifying endoscopy(LCI/BLI-ME)in determining the depth of infiltration in early gastric cancer after eradication of Helicobacter pylori(H.pylori),as well as the influencing factors affecting the accuracy of the judg-ment,so as to explore its clinical application value.Methods Clinical data of 91 patients with early gastric cancer after H.pylori eradication were collected from October 2017 to June 2023 in Wuhan No.1 Hospital.Based on the pathological diag-nosis,the endoscopic manifestations of gastric mucosa and early gastric cancer after eradication of H.pylori were summa-rized.The accuracy of endoscopic ultrasonography combined with LCI/BLI-ME in determining the infiltrating depth of early gastric cancer and the related factors affecting the accuracy were evaluated.Sensitivity,specificity,and accuracy were used to in-dicate the effectiveness of endoscopic diagnosis.Chi-square test was used to compare the difference between endoscopic diagnosis and pathological diagnosis.Logistic regression analysis was used to determine the factors affecting the diagnostic accuracy of en-doscopy.Results The overall accuracy of endoscopic ultrasonography combined with LCI/BLI-ME in determining the infiltra-tion depth of early gastric cancer after H.pylorieradication was 77.08%,and the accuracies of uT1a and uT1b stages were 82.86%and 61.53%,respectively.There were 12 under-diagnosed cases(17.14%)and 10 over-diagnosed cases(38.46%).The sensitivity,specificity,positive predictive value and negative predictive value of endoscopic ultrasonography combined with LCI/BLI-ME in the diagnosis of mucosal lesions were 85.29%,57.14%,82.86%and 61.5%,respectively.The results of univariate and multivariate logistic regression analysis showed that the maximum diameter of the lesion and the degree of tissue differentia-tion were the factors affecting the diagnostic accuracy,but not the location and shape of the lesion.The accuracy of endoscopy in judging the infiltration depth of early gastric cancer was decreased with the increase of lesion or the reduction of tissue differen-tiation degree.Conclusion Endoscopic ultrasonography combined with LCI/BLI-ME has good clinical application value in deter-mining the infiltration depth of early gastric cancer T1a after H.pylori eradication.The lesion size and the degree of tissue dif-ferentiation affect the accuracy of the judgment.

4.
Article de Chinois | WPRIM | ID: wpr-1029599

RÉSUMÉ

Objective:To investigate the application of endoscopic ultrasound-guided liver biopsy (EUS-LB) to liver transplant recipients.Methods:In this retrospective cohort study, a total of 12 liver transplant recipients who underwent EUS-LB by the same endoscopist and specimens were diagnosed and reported by the same pathologist due to abnormal liver function or need to be evaluated for graft fibrosis in the Organ Transplantation Center of the Affiliated Hospital of Qingdao University were enrolled into the EUS-LB group from December 2021 to March 2022, meanwhile, a total of 23 patients whose PLB was completed by the same hepatologist and specimens were diagnosed by the same pathologist during the same period were enrolled in the PLB group. Acquisition of liver specimens and postoperative adverse events of the two groups were compared.Results:Patients in both groups were punctured 1-2 times on average, and the median total length of liver specimens in the EUS-LB group was significantly longer than that in the PLB group (61 mm VS 17 mm, Z=11.362, P=0.002). There was no significant difference in the length of the longest liver specimens between the two groups (17.6±6.9 mm VS 13.7±3.5 mm, t=2.382, P=0.086), while the number of liver specimens in the EUS-LB group was more than that in the PLB group (4.8±2.1 VS 2.3±1.2, t=9.271, P=0.001). The number of complete portal tracts was 11.3±4.6 in the EUS-LB group and 6.2±3.3 in the PLB group ( t=8.457, P=0.003). Abdominal pain was the only postoperative adverse event, and only 1 patient in the EUS-LB group had postoperative abdominal pain, which was fewer than that in the PLB group [8.3% (1/12) VS 43.5% (10/23), χ2=4.893, P=0.036]. Conclusion:Compared with PLB, EUS-LB delivers longer liver biopsy specimens with more complete portal tracts in liver transplant recipients, and fewer recipients complain about postoperative pain in EUS-LB group. Therefore, EUS-LB is a safer, more effective and more comfortable liver biopsy method.

5.
Article de Chinois | WPRIM | ID: wpr-1029600

RÉSUMÉ

Objective:To analyze the differences in clinical and endoscopic ultrasonography (EUS) findings between diffuse and focal IgG4-related autoimmune pancreatitis (IgG4-AIP).Methods:Data of patients diagnosed as having IgG4-AIP who underwent EUS at Chinese PLA General Hospital from September 2011 to April 2022 were retrospectively collected. General clinical data, EUS features, and postoperative pathology were analyzed for characteristic differences.Results:A total of 40 patients were included in the study, 60.03±10.87 years old, a higher proportion of males (85.0%, 34/40). All patients underwent EUS, and 28 underwent EUS-guided fine-needle aspiration. Among the 40 patients, 29 (72.5%) had diffuse type and 11 (27.5%) had focal type. Abdominal pain [65.5% (19/29) VS 18.2% (2/11), χ2=5.393, P=0.020] and thickening of the bile duct wall [51.7% (15/29) VS 9.1% (1/11), χ2=4.394, P=0.036] were more common in the diffuse type, while main pancreatic duct dilation [45.5% (5/11) VS 10.3% (3/29), χ2=4.146, P=0.042] was more common in the focal type, with the lesion most commonly located in the pancreatic head (90.9%, 10/11). There was no significant difference in the presence of chronic pancreatitis parenchymal changes between the two groups [34.5% (10/29) VS 27.3% (3/11), χ2=0.003, P=0.955]. Conclusion:There are certain differences in abdominal pain and biliary and pancreatic duct lesions between diffuse and focal AIP. The high expression of chronic pancreatitis characteristics is not observed in either group, which provides clues for the classification of AIP in clinical practice.

6.
Journal of Clinical Hepatology ; (12): 997-1002, 2024.
Article de Chinois | WPRIM | ID: wpr-1030793

RÉSUMÉ

ObjectiveTo summarize the liver biopsy and clinical features of patients with liver injury of unknown origin, and to investigate the value of ultrasound-guided percutaneous liver biopsy in the diagnosis of liver injury of unknown origin. MethodsA retrospective analysis was performed for the clinical data and ultrasound-guided percutaneous liver biopsy results of 94 patients with liver injury of unknown origin who were admitted to Zhongshan Hospital, Xiamen University, from January 2018 to February 2023. According to the proportion of the patients with different final diagnoses, the patients were divided into autoimmune liver disease (AILD) group, metabolic associated fatty liver disease (MAFLD) group, drug-induced liver injury (DILI) group, alcoholic liver disease (ALD) group, and unknown group. An analysis of variance was used for comparison of normally distributed continuous data between multiple groups, and the Bonferroni analysis or the Dunnett’ T3 test was used for further comparison between two groups; the Kruskal-Wallis H test was used for comparison of non-normally distributed continuous data between multiple groups; the Fisher’s exact test was used for comparison of categorical data between multiple groups. ResultsAll 94 patients with liver injury of unknown origin underwent ultrasound-guided percutaneous liver biopsy after admission, among whom 90 patients (95.7%) had a confirmed diagnosis based on liver biopsy and clinical features. There were 43 patients (45.7%) with AILD, 21 (22.3%) with MAFLD, 15 (16.0%) with DILI, 6 (6.4%) with ALD, 1 (1.1%) with AILD and MAFLD, 1 (1.1%) with hemochromatosis, 1 (1.1%) with Budd-Chiari syndrome, 1 (1.1%) with congenital hepatic fibrosis, and 1 (1.1%) with idiopathic portal hypertension, while 4 patients (4.3%) still had an unknown etiology after liver biopsy. There were significant differences between the patients with top five diagnoses in age (F=4.457, P<0.05) , body mass index (BMI) (F=3.245, P<0.05), aspartate aminotransferase (AST) (H=11.128, P<0.05), gamma-glutamyl transpeptidase (GGT) (H=24.789, P<0.05), alkaline phosphatase (ALP) (H=26.013, P<0.05), IgG (H=19.099, P<0.05), IgM (H=21.263, P<0.05), AMA-M2 positive rate (P<0.05), and ANA positive rate (P<0.05). Compared with the MAFLD group, the AILD group had significantly higher age, AST, GGT, and ALP and a significantly lower BMI; compared with the MAFLD group and the DILI group, the AILD group had significant increases in IgG and IgM; the AILD group had significant increases in the positive rates of AMA-M2 and ANA compared with the other four groups. ConclusionAILD, MAFLD, and DILI are the most common causes in patients with liver injury of unknown origin. Ultrasound-guided percutaneous liver biopsy plays an important role in determining the cause of liver injury of unknown origin, but it is still needed to make a comprehensive analysis based on clinical history, different types of liver injury, laboratory markers, and imaging data.

7.
Journal of Rural Medicine ; : 196-198, 2024.
Article de Anglais | WPRIM | ID: wpr-1040012

RÉSUMÉ

Objective: We report a case of spontaneous migration of a dedicated plastic stent after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) in a patient with surgically altered anatomy.Patient: The patient was a male in his 70s. He underwent EUS-HGS with the successful insertion of a dedicated plastic stent and had no obvious postprocedural complications. However, nine days after the procedure, the patient visited our hospital because of abdominal pain, fever, and stent excretion. We performed EUS-HGS with antegrade stenting, after which the patient had no further complications.Conclusion: Stent migration is considered a complication requiring caution when performing EUS-HGS in patients with surgically altered anatomy.

8.
Acta Medica Philippina ; : 76-81, 2024.
Article de Anglais | WPRIM | ID: wpr-1012456

RÉSUMÉ

@#Gastric adenocarcinoma presenting as a submucosal tumor (SMT) accounts to only 0.1% to 0.63%. A 56-year-old Filipino male presenting with new onset melena underwent magnifying endoscopy, narrow-band imaging, endoscopic ultrasound, and computed tomography revealing a 2.5 cm x 2.0 cm polypoid SMT-like lesion at the fundus. Total gastrectomy with lymph node dissection and esophagojejunostomy was performed with histopathology showing adenocarcinoma. This suggests the need for different modalities to ensure the accuracy of diagnosis and the need for subsequent invasive treatments.

9.
Journal of Clinical Hepatology ; (12): 739-744, 2024.
Article de Chinois | WPRIM | ID: wpr-1016518

RÉSUMÉ

ObjectiveTo investigate the efficacy, safety, and cost-effectiveness of endoscopic ultrasound (EUS)-guided coil placement combined with tissue adhesive injection in the treatment of gastric varices with spontaneous shunt. MethodsA retrospective analysis was performed for the patients with acute gastric variceal bleeding and spontaneous portosystemic shunt who were hospitalized and received balloon-occluded retrograde transvenous obliteration (BRTO) combined with endoscopic tissue adhesive injection or EUS-guided coil placement combined with tissue adhesive injection in Xiangyang Central Hospital from March 2019 to September 2022. The two surgical procedures were compared in terms of efficacy (technical success rate, 5-day rebleeding rate, 1-year rebleeding rate, and time to rebleeding), safety (the incidence rate of ectopic embolism, the amount of tissue adhesive used, and the amount of lauromacrogol used), and cost-effectiveness (hospital costs and length of hospital stay). The t-test was used for comparison of normally distributed continuous data between two groups, and the Mann-Whitney U test was used for comparison of non-normally distributed continuous data between two groups. The Kaplan-Meier method was used to estimate the rebleeding. The chi-square test was used for comparison of categorical data between two groups. ResultsA total of 25 patients received successful EUS-guided coil placement and tissue adhesive injection, with a technical success rate of 100%, a median amount of 2.5 mL tissue adhesive used, a median amount of 11.0 mL lauromacrogol used, a mean length of hospital stay of 14.88±3.21 days, a mean hospital cost of 32 660.00±4 602.07 yuan, and a 5-day rebleeding rate of 0%; among these patients, 2 were lost to follow-up, and 23 patients with complete follow-up data had an incidence rate of ectopic embolism of 0% and a median time to rebleeding of 689 days. A total of 14 patients underwent modified BRTO combined with endoscopic tissue adhesive injection, with a technical success rate of 100%; a median amount of 5.0 mL tissue adhesive used during surgery, which was significantly higher than that used in EUS (U=39.000, P<0.001); a median amount of 10.5 mL lauromacrogol used during surgery; a mean length of hospital stay of 15.38±4.94 days; a mean hospital cost of 57 583.47±18 955.40 yuan, which was significantly higher than that used in EUS (t=-6.310, P<0.001); a 5-day rebleeding rate of 0%. No patient was lost to follow-up, and all 14 patients had an incidence rate of ectopic embolism of 0% and a median time to rebleeding of 244.50 days, with no significant difference between the two groups (χ2=1.448, P=0.229). ConclusionEUS-guided coil placement combined with tissue adhesive injection is a relatively safe and effective technique for the treatment of gastric variceal bleeding and has a high technical success rate, a low incidence rate of serious adverse events, and similar efficacy to BRTO, with higher safety and cost-effectiveness.

10.
Journal of Clinical Hepatology ; (12): 834-838, 2024.
Article de Chinois | WPRIM | ID: wpr-1016533

RÉSUMÉ

Liver disease is one of the most important health problems around the world, and early diagnosis and timely intervention and treatment are the key to preventing liver-related morbidity and mortality rates. The development of endoscopic techniques has provided new diagnostic and intervention methods for liver diseases. This article reviews the application and development of endoscopic techniques in liver diseases from the following aspects: the technical advances and advantages of endoscopic ultrasound-guided liver biopsy; the application and development of endoscopic techniques in the treatment of portal hypertension caused by liver abscess/hepatic cyst and liver diseases, as well as interventional techniques in the treatment of liver tumors; the efficacy and prospects of the endoscopic techniques for weight loss, which are relatively new in China, in the treatment of nonalcoholic fatty liver disease/nonalcoholic steatohepatitis. Endoscopic techniques may hold promise for wide clinical application and exploration in in liver-related diseases in China, so as to provide more options for patients and doctors.

11.
Article de Chinois | WPRIM | ID: wpr-1023206

RÉSUMÉ

Objective:To evaluate the diagnostic value of rapid on-site evaluation (ROSE) performed by endoscopists for solid pancreatic lesions requiring tissue for immunohistochemistry (IHC) staining with different approach of endoscopic ultrasound-guided tissue acquisition (EUS-TA).Methods:After screening 1 573 cases who underwent EUS-TA operation at the Endoscopy Center of Peking Union Medical College Hospital between August 2018 and October 2022, a total of 65 cases of solid pancreatic lesions whose diagnosis rely on IHC staining was collected and summarized with clinical data of each case. Among 65 cases, there were 46 cases of pancreatic neuroendocrine tumors (PNETs), 13 cases of pancreatic solid pseudo-papillary tumors (SPTs), and 6 cases of lymphomas and mesenchymal. Patients were categorized into ROSE group (36 cases) and non-ROSE group (29 cases) according to the presence or absence of endoscopists performed ROSE during EUS-TA operation. They were further divided into subgroups of FNA-ROSE (26 cases), FNB-ROSE (10 cases), FNA-non-ROSE (24 cases) and FNB-non-ROSE (5 cases) according to the type of EUS-TA. Diagnostic accuracy and IHC success rate were compared between different groups and subgroups. Binomial logistic multifactorial regression analysis was used to evaluate the influence of ROSE and EUS-TA type on diagnostic accuracy and IHC success rate.Results:There were no statistically significant differences between ROSE group and non-ROSE group in terms of age, gender, bilirubin level, CA19-9 level, lesion site, lesion size, composition ratio of diagnosis, and surgical rate. The differences in mean size of lesions, needle gauge, location of puncturation, and number of needle pass between subgroups were not statistically significant. The diagnostic accuracy was 88.9% in ROSE group and 79.3% in non-ROSE group, and the difference between the two groups was statistically significant ( P=0.023). The diagnostic accuracy of FNA-ROSE group was higher than that of FNA-non-ROSE group (88.5% vs 75.0%), but the difference was not statistically significant ( P>0.100). The differences in diagnostic accuracy and success rate of IHC between FNB-ROSE group and FNB-non-ROSE group were not statistically significant. Binomial logistic multifactorial regression analysis did not reveal any independent influences on diagnostic accuracy. Conclusions:ROSE performed by endoscopists improved diagnostic accuracy of EUS-TA in solid pancreatic lesions requiring IHC staining, and therefore is potentially valuable for improving the diagnostic efficiency of EUS-TA for such diseases.

12.
Article de Chinois | WPRIM | ID: wpr-1023208

RÉSUMÉ

Objective:To analyze clinical characteristics of primary pancreatic lymphoma (PPL) patients.Methods:Clinical features of 22 patients diagnosed as PPL admitted to Peking Union Medical College Hospital from January 2002 to May 2023 were analyzed retrospectively.Results:The median age was 56.4±13.3 years. The median time from onset to diagnosis was 1.0 (1.0, 3.0) months. The main clinical manifestations were abdominal pain (15/22), weight loss (14/22) and jaundice (10/22). Elevated lactate dehydrogenase (LDH) was observed in 15/20 (75%) patients. Only 2 (2/9, 22.2%) patients had increased CA199 levels and 2 (2/9, 22.2%) patients had increased CEA levels. The maximum tumor diameter was 5.0 (3.8, 6.9) cm. Contrast-enhanced CT mostly showed low enhancement lesions. Major pancreatic duct dilatation were rare on CT scan (4/20). Fifteen patients were confirmed by pancreatic pathology, of which 8 were obtained by surgery, 4 were obtained by CT or ultrasound-guided percutaneous biopsy, and 3 were obtained by EUS-FNA. The main pathological type was diffuse large B-cell lymphoma (14/22). 19 patients received chemotherapy, and 6 patients died with a median follow-up of 5.0 (1.5, 35.5) months.Conclusions:PPL is rare and easy to be misdiagnosed. Elevated LDH levels, normal tumor markers, and non-dilatation of main pancreatic duct are important diagnostic clues. It is important to obtain pathology by EUS-FNA and other methods for definite diagnosis.

13.
Article de Chinois | WPRIM | ID: wpr-1024337

RÉSUMÉ

Objective To evaluate the value of miniprobe endoscopic ultrasound(EUS)in guiding endoscopic treatment of small-diameter(maximum diameter less than 1 cm)and low-grade(G1 grade)rectum neuroendocrine neoplasm(R-NEN),and to provide evidence and clues for its clinical application and further research.Methods The clinical data of 85 cases of low-grade(G1 grade)R-NEN with a maximum diameter of less than 1 cm who underwent endoscopic treatment in our center from January 2014 to December 2020 were retrospectively analyzed.The patients were divided into the EUS group(37 cases)and control group(48 cases)according to whether EUS was performed before endoscopic treatment.The positive rate of incision margin,the incidence of complications,the recurrence rate,the hospital stay,the cost of hospitalization and endoscopic therapy were compared between the two groups.Results The positive rate of incision margin in the EUS group was significantly lower than that in control group(P<0.05).There was no significant difference in the incidence of complications,tumor recurrence rate,hospital stay or hospital costs between the two groups(P>0.05).There was statistically significant difference in the endoscopic therapy between the two groups(P<0.05).Conclusion Evaluating the lesion depth of small-diameter and low-grade(G1 grade)R-NEN before surgery by miniprobe EUS and selecting endoscopic surgery according to its results of can significantly reduce the residual risk of resection margin tumors.

14.
J. bras. pneumol ; J. bras. pneumol;50(3): e20230353, 2024. tab, graf
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1569301

RÉSUMÉ

ABSTRACT Objective: Although EBUS-TBNA combined with EUS-FNA or EUS-B-FNA stands as the primary approach for mediastinal staging in lung cancer, guidelines recommend mediastinoscopy confirmation if a lymph node identified on chest CT or showing increased PET scan uptake yields negativity on these techniques. This study aimed to assess the staging precision of EBUS/EUS. Methods: We conducted a retrospective study comparing the clinical staging of non-small cell lung cancer patients undergoing EBUS/EUS with their post-surgery pathological staging. We analyzed the influence of histology, location, tumor size, and the time lapse between EBUS and surgery. Patients with N0/N1 staging on EBUS/EUS, undergoing surgery, and with at least one station approached in both procedures were selected. Post-surgery, patients were categorized into N0/N1 and N2 groups. Results: Among the included patients (n = 47), pathological upstaging to N2 occurred in 6 (12.8%). Of these, 4 (66.7%) had a single N2 station, and 2 (33.3%) had multiple N2 stations. The adenopathy most frequently associated with upstaging was station 7. None of the analyzed variables demonstrated a statistically significant difference in the occurrence of upstaging. PET scan indicated increased uptake in only one of these adenopathies, and only one was visualized on chest CT. Conclusions: Upstaging proved independent of the studied variables, and only 2 patients with negative EBUS/EUS would warrant referral for mediastinoscopy. Exploring other noninvasive methods with even greater sensitivity for detecting micrometastatic lymph node disease is crucial.

15.
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1535963

RÉSUMÉ

We describe the first case in our environment of endoscopic ultrasound (EUS)-assisted transgastric endoscopic retrograde cholangiopancreatography in a patient with gastric bypass surgery. The procedure was performed with a side-viewing duodenoscope through a jejunogastrostomy using apposing stents, placed with EUS assistance, and a standard technique and instruments.


Se describe el primer caso en nuestro medio de colangiopancreatografía retrógrada endoscópica transgástrica asistida por endosonografía en una paciente con cirugía de baipás gástrico. El procedimiento se realizó con duodenoscopio de visión lateral a través de una yeyunogastrostomía por stent de aposición, emplazado con asistencia endosonográfica y con una técnica e instrumental estándar.

16.
Rev. colomb. gastroenterol ; 38(3)sept. 2023.
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1535930

RÉSUMÉ

Introduction: Endoscopic ultrasound (EUS)-guided drainage and luminal-apposing metal stents (LAMS) are the options for managing symptomatic pancreatic pseudocysts. Aim: To evaluate the effectiveness and safety of LAMS for EUS-guided drainage of symptomatic pancreatic pseudocysts in two referral centers in Colombia. Materials and methods: A multicenter prospective cohort study between June 2019 and December 2021 included 13 patients diagnosed with symptomatic pancreatic pseudocysts who underwent EUS-guided drainage with LAMS. Technical success, clinical success, and successful stent removal were evaluated as outcomes. Safety outcomes included stent-related adverse events and general adverse events. Follow-up was carried out for eight weeks, collecting data on stent removal. Results: The average age was 53.4 years; 8/13 were men. The mean size of the pseudocyst was 9.56 ± 2.3 cm. Technical success was 100%, and clinical success was 92.3%. The stents were removed on average after 8 ± 2 weeks. The mean procedural time from puncture to stent deployment was 3.2 ± 2.4 minutes. In the imaging check-up, the collections had adequate drainage in all cases. There was a low frequency of complications; bleeding was documented in one case requiring surgery. Conclusions: LAMS is safe and effective in managing symptomatic pancreatic pseudocysts, reducing hospital stay and cost overruns. Clinical symptomatology prevails in the surgery decision.


Introducción: el drenaje guiado por ultrasonido endoscópico (USE) y el uso de stent metálico luminal de aposición (LAMS) son de elección en el manejo de los pseudoquistes pancreáticos sintomáticos. Objetivo: evaluar la efectividad y seguridad del LAMS para el drenaje por USE de pseudoquistes pancreáticos sintomáticos en dos centros de referencia en Colombia. Materiales y métodos: estudio de cohorte prospectivo multicéntrico entre junio de 2019 y diciembre de 2021, se incluyeron a 13 pacientes con diagnóstico de pseudoquistes pancreáticos sintomáticos sometidos a drenaje por USE con LAMS. Se evaluaron como desenlaces el éxito técnico, el éxito clínico y la extracción exitosa del stent. Y los desenlaces de seguridad incluyeron eventos adversos relacionados con el stent y los eventos adversos generales. Se realizó seguimiento a 8 semanas, en las que se recopilaron datos relacionados con el retiro del stent. Resultados: la edad promedio fue 53,4 años, 8/13 fueron hombres. El tamaño medio del pseudoquiste fue de 9,56 ± 2,3 cm. El éxito técnico fue del 100% y el éxito clínico fue 92,3%. Los stents fueron retirados en promedio a las 8 ± 2 semanas. El tiempo medio del procedimiento desde la punción hasta el despliegue del stent fue 3,2 ± 2,4 minutos. En el control imagenológico hubo un adecuado drenaje de las colecciones en todos los casos. Hubo baja frecuencia de complicaciones, se documentó sangrado en 1 caso con requerimiento quirúrgico. Conclusiones: el uso de LAMS es seguro y efectivo en el manejo de pseudoquistes pancreáticos sintomáticos, disminuye la estancia hospitalaria y sobrecostos. La sintomatología clínica prima en la decisión de intervención.

17.
Arq. gastroenterol ; Arq. gastroenterol;60(3): 364-372, July-Sept. 2023. tab
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1513705

RÉSUMÉ

ABSTRACT Background: Reports of the impact of the 2020 COVID-19 pandemic period/2020 on endoscopic ultrasound (EUS) are scarce. Objective: We analyzed the impact of the pandemic period/2020 on the demographics, indications, and number of diagnostic EUS (D-EUS) and interventional EUS (I-EUS) procedures performed in a high-volume endoscopy unit compared with the previous non-pandemic period/2019. Methods: We retrospectively reviewed the medical records of all patients undergoing D-EUS or I-EUS from March 1, 2019, to February 29, 2020 (non-pandemic period/2019) and from March 1, 2020, to February 28, 2021 (pandemic period/2020). Data compared between the study periods included sex, age, comorbidities, EUS findings and diagnosis, need for interventional procedures during EUS, and adverse events (AEs). Results were significant at P<0.05. Results: EUS procedures decreased from 475 in the non-pandemic period/2019 to 289 in the pandemic period/2020, accounting for a 39% reduction. In non-pandemic period/2019, 388 (81.7%) D-EUS and 88 (18.5%) I-EUS were performed, against 206 (71.3%) D-EUS and 83 (28.7%) I-EUS in pandemic period/2020 (P=0.001). Only 5/289 (1.7%) patients had COVID-19. Fewer patients with comorbidities underwent EUS during pandemic period/2020 due to lockdown measures (P<0.001). D-EUS decreased, whereas I-EUS increased (P<0.001). EUS-guided tissue acquisition (EUS-TA) was the most common I-EUS, performed in 83/289 (28.7%) patients in pandemic period/2020, against 88/475 (18.5%) in non-pandemic period/2019 (P=0.001). AEs did not differ significantly between the study periods. Conclusion: Pandemic Period/2020 had a moderate impact on reducing EUS procedures due to the risks involved. Although I-EUS increased, EUS-related AEs did not. Solid and cystic pancreatic tumors remained a major indication for EUS-TA even during the pandemic period/2020.


RESUMO Contexto: Os dados sobre o impacto da pandemia de COVID-19 2020 na ultrassonografia endoscópica (EUS) são escassos. Objetivo: Analisamos o impacto do período pandêmico/2020 na demografia, indicações e número das EUS diagnósticas (D-EUS) e intervencionistas EUS (I-EUS) realizados em uma unidade de endoscopia de alto volume e os comparamos com o período imediatamente anterior não-pandêmico/2019. Métodos: Revisamos retrospectivamente os prontuários de todos os pacientes submetidos a D-EUS ou I-EUS de 1 de março de 2019 a 29 de fevereiro de 2020 (período não-pandêmico/2019) e de 1º de março de 2020 a 28 de fevereiro de 2021 (período da pandemia/2020). Comparamos os dados entre os períodos do estudo incluímos o sexo, idade, comorbidades, achados e diagnóstico da EUS, necessidade de procedimentos intervencionistas durante a EUS e a ocorrência de eventos adversos (EAs). Os resultados foram significativos com P<0,05. Resultados: O número de ecoendoscopias diminuíram de 475 no período não-pandêmico/2019 para 289 no período pandêmico/2020, representando uma redução de 39%. No período não-pandêmico/2019 e pandêmico/2020 foram realizados 388 (81,7%) D-EUS e 88 (18,5%) I-EUS, contra 206 (71,3%) D-EUS e 83 (28,7%) I-EUS, respectivamente (P=0,001). Apenas 5/289 (1,7%) pacientes tinham COVID-19. Menos pacientes com comorbidades realizaram EUS durante o período pandêmico/2020 devido as medidas de bloqueio (P<0,001). D-EUS diminuiu, enquanto I-EUS aumentou (P<0,001). A EUS associada a aquisição tecidual (EUS-AT) foi a I-EUS mais comum, realizada em 83/289 (28,7%) pacientes no período pandêmico/2020, versus 88/475 (18,5%) no período não-pandêmico/2019 (P=0,001). Os EAs não diferiram significativamente entre os períodos do estudo. Conclusão: O período da pandemia/2020 teve impacto moderado na redução da EUS devido aos riscos envolvidos. Embora o I-EUS tenha aumentado, os EAs relacionados ao EUS não aumentaram. Os tumores pancreáticos sólidos e císticos permaneceram como uma das principais indicações para EUS-AT mesmo durante o período pandêmico/2020.

19.
Article de Chinois | WPRIM | ID: wpr-1021131

RÉSUMÉ

Gastric outlet obstruction,also known as pyloric obstruction or stenosis,refers to pyloric stenosis caused by mechanical compression or obstruction of the duodenum,distal stomach,pyloric duct,and anterior pyloric region.Patients will have the phenomenon that gastric contents cannot pass,accompanied by nausea,vomiting,abdominal pain,and loss of appetite and other related symptoms,which greatly reduces the quality of life of patients,has a wide range of individual impact,and has a high degree of harm.Scientific treatment of this disease has extremely important social significance.Based on the pathogenesis,clinical diagnosis and treatment strategies of gastric outlet obstruction,this article will make a certain summary for the diagnosis and treatment of gastric outlet obstruction for reference.

20.
Article de Chinois | WPRIM | ID: wpr-1029558

RÉSUMÉ

Objective:To apply endoscopic ultrasound (EUS) elastography to the evaluation of EUS-guided fine needle injection (EUS-FNI) for insulinoma.Methods:Clinical data of 21 patients with insulinoma who were treated with EUS-FNI at the digestive endoscopy center of the First Affiliated Hospital of Guangxi Medical University from April 2016 to March 2021 were collected. Some patients underwent EUS real-time elastography before and after the treatment. The minimum blood glucose, synchronous insulin, synchronous C peptide, elastic imaging color pattern, elastic score, a-elasticity, elastic imaging strain rate before and after the treatment were analyzed.Results:Among the 21 cases with 24 lesions, there were 5 males and 16 females. There were totally 39 times of injection, where 8 cases underwent single injection, and 13 cases repeated injection. After the operation, patients' symptoms improved, the minimum blood glucose increased in different degree [2.59 (1.95, 3.82) mmol/L VS 1.50 (1.00, 2.00) mmol/L, Z=-4.278, P<0.001], the level of synchronous insulin [96.69 (44.80, 249.30) pmol/L VS 159.10 (100.30, 373.70) pmol/L, Z=-1.445, P=0.148] and C peptide [3.56 (2.98, 8.05) ng/mL VS 6.16 (3.74, 11.47) ng/mL, Z=-1.825, P=0.068] decreased, but no statistical difference compared with those before the operation. Sixteen cases underwent preoperative endoscopic elastography, with elastic score of 2.00 (2.00, 3.00), and 15 cases underwent postoperative elastography with elastic score of 5.00 (5.00, 5.00). Preoperative a-elasticity was recorded in 15 cases with value of 0.16 (0.08, 0.30), and postoperative a-elasticity was recorded in 12 cases with value of 0.07 (0.05, 0.18). The preoperative strain rate were recorded in 14 cases with 2.28 (1.67, 4.38), and postoperative strain rate were recorded in 12 cases with 5.16 (2.08, 8.17). Compared with those before the operation, the postoperative elastic score increased ( Z=-4.694, P<0.001), the a-elasticity decreased ( Z=-2.099, P=0.036), and the difference in strain ratio was not statistically significant ( Z=-1.492, P=0.136). Meanwhile, the lesions of insulinoma became harder, the elastic imaging mode changed from green to blue. There were no complications such as abdominal pain, fever, or pancreatitis during and after the operation. Conclusion:EUS-FNI is safe and effective for the treatment of insulinoma. Endoscopic elastography, as a new means to evaluate the efficacy of the operation, can be used to evaluate lesion ablation and guide injection therapy.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE