Chinese Journal of Practical Nursing ; (36): 2383-2384, 2015.
Article Dans Chinois | WPRIM | ID: wpr-485163

Résumé

Objective To propose a new observation procedure of blood pressure after the surgery of fiducial implantation for cyber knife, using the statistical analysis of the measurements of blood pressure at different time after the surgery. Methods By taking 200 patients after the surgery of fiducial implantation, the usual blood pressures and the blood pressures at different time after the surgery were compared statistically. Results Based on the statistical analysis, the usual blood pressures were statistically different from the blood pressure immediately after surgery, as well as the blood pressure at 0.5 hours after surgery [ systolic pressure (131.60 ±16.86), (129.08 ±14.77) mmHg (1 mmHg=0.133 kPa) vs. (123.00 ±11.80) mmHg, t=2.897 and 2.308, P0.05. Conclusions Measuring the blood pressures at the time of 0, 0.5, 3.5 hours after the surgery can not only assure the complete recovery of the patients after the surgery, but also greatly reduce the work of nurses.

2.
Chinese Journal of Radiation Oncology ; (6): 58-60, 2013.
Article Dans Chinois | WPRIM | ID: wpr-432132

Résumé

Objective To analyze the factors influencing fiducial number used for tracking abdominal tumor with stereotactic body radiation therapy (SBRT),which was implemented by CyberKnife.Methods 254 abdominal tumor patients chosen which adopted fiducial tracking and classified the fiducials.We gathered data of the patients with < 3 fiducials used for tracking and patients with ≥ 3 fiducials respectively,and analyzed the reason why < 3 fiducials were left for tracking.Results Among 254 patients,22 patients were showed that the number of fiducial implantation were equal to play number of fiducial;232 patients with no equation which 49 patients (21.1%) used < 3 fiducials for tracking,183 patients (78.9%) used ≥3 fiducials for tracking.Among the 49 patients with <3 fiducials for tracking,9 patients had fiducials migrated,1 patient had an unrecognizable fiducial,23 patients had the implantation not qualified for tracking,and 16 patients had the rigid error surpassing the threshold.Conclusions 78.9% patients were implanted ≥ 3 fiducials and thus qualified for fiducial tracking.Major reasons of disqualification include insufficient implanted fiducials,unqualified implantation and rigid error surpassing the threshold.

SÉLECTION CITATIONS
Détails de la recherche