1.
Journal of Korean Academy of Conservative Dentistry ; : 58-65, 2006.
Article Dans Coréen | WPRIM | ID: wpr-214341

Résumé

The possibility of applying a bi-axial flexure strength test on composite resin was examined using three point and bi-axial flexure strength tests to measure the strength of the light-cured resin and to compare the relative reliability using the Weibull modulus. The materials used in this study were light-curing restorative materials, MICRONEW(TM), RENEW(R) (Bisco, Schaumburg, USA). The bi-axial flexure strength measurements used the piston-on-3-ball test according to the regulations of the International Organization for Standardization (ISO) 6872 and were divided into 6 groups, where the radius of the specimens were 12 mm (radius connecting the 3-balls: 3.75 mm), 16 mm (radius connecting the 3-balls: 5 mm), and the thickness were 0.5 mm, 1 mm, 2 mm for each radius. The bi-axial flexure strength of the MICRONEW(TM) and RENEW(R) were higher than the three point flexure strength and the Weibull modulus value were also higher in all of the bi-axial flexure strength groups, indicating that the bi-axial strength test is relatively less affected by experimental error. In addition, the 2 mm thick specimens had the highest Weibull modulus values in the bi-axial flexure strength test, and the MICRONEW(TM) group showed no significant statistical difference (p > 0.05). Besides the 2 mm MICRONEW(TM) group, each group showed significant statistical differences (p < 0.05) according to the thickness of the specimen and the radius connecting the 3-balls. The results indicate that for the 2 mm group, the bi-axial flexure strength test is a more reliable testing method than the three point flexure strength test.


Sujets)
Radius , Contrôle social formel
2.
The Journal of Korean Academy of Prosthodontics ; : 71-80, 2003.
Article Dans Coréen | WPRIM | ID: wpr-124669

Résumé

Development of new ceramic and esthetic need of patient increased the use of ceramic restorations. The purpose of this study was to confirm the possibility of recycling for IPS Empress2 which has a lot of advantages in esthetics. 1st, 2nd and 3rd pressed disc-shaped(10x1.5mm) IPS Empress 2 specimens were made with IPS Empress ingot(shade 200, Ivoclar, Liechtenstein) and pressing furnace(IPS Empress EP 500, Ivoclar, Liechtenstein). Flexure strength was measured with universal testing machine(Zwick 145641, Zwick, Germany), and color change and staining resistance of specimens were evaluated with colorimeter (Model TC-6FX, Tokyo Denshoku Co., Japan). The followings were drawn from this study : 1. Flexure strength of the 1st, the 2nd, and the 3rd pressed specimens showed 236.78 MPa, 247.16MPa, and 220.72MPa, respectively. Flexure strength of the 2nd pressed specimens was higher than others, but there's no statistical difference between them. 2. The color difference between the 1st and the 2nd pressed specimens was 3.25, and that between the 1st and the 3rd pressed specimens was 3.63(P<0.05). 3. The color change after staining of the 1st, the 2nd, and the 3rd pressed specimens were 1.43, 2.64, and 1.45, respectively. In this study, reused IPS Empress 2 specimens showed insignificant change of flexure strength and stain resistance, but they showed some color change according to reuse. From this results, the limited possibility of reuse for IPS Empress 2 could be considered.


Sujets)
Humains , Céramiques , Esthétique , Recyclage
3.
The Journal of Korean Academy of Prosthodontics ; : 572-576, 2002.
Article Dans Anglais | WPRIM | ID: wpr-204789

Résumé

This investigation was designed to estimate the biaxial flexure strength and fracture toughness of lithium disilicate glass-ceramics of IPS Empress 2 system pressed with as-received ingots and their sprue buttons. Two groups of the lithium disilicate glass-ceramics were prepared as follows: group 1 is ingot-pressed group; group 2 is sprue button-pressed group. A ball-on-three-ball test was used to determine biaxial flexure strength (BFS) of disks in wet environment. Scanning electron microscopy(SEM) analysis was conducted to observe the microstructure of the ceramics. Unpaired t-test showed that there were no differences in the mean biaxial flexure strength (BFS) and KIC values between group 1 and 2 (p>0.05). Two groups showed similar values in the KIC and the strength at 5% failure probability. The SEM micrographs of the IPS Empress 2 glass-ceramic showed a closely packed, multi-directionally interlocking pattern of numerous lithium disilicate crystals protruding from the glass matrix. The lithium orthophosphate crystals could not be observed on the fracture surface etched. There was no a marked difference of the microstructure between group 1 and 2. Although there were no tests including color stability, casting accuracy, etc., the results of this study implied that we could reuse the sprue button of the pressed lithium disilicate glass-ceramic of IPS Empress 2 system.


Sujets)
Maladie coeliaque , Céramiques , Verre , Lithium , Phosphates
4.
The Journal of Korean Academy of Prosthodontics ; : 575-582, 2000.
Article Dans Coréen | WPRIM | ID: wpr-151161

Résumé

This investigation was designed to determine whether heat-pressing and/or simulated heat treatments affected the flexure strength and the microstructure of the lithium disilicate glassceramic in the IPS Empress 2 system. Four groups of the specimens were prepared as follows group 1 - as-received material ; group 2 - heat-pressed material ; group 3 - heat pressed and simulated initial heat-treated material ; group 4 - heat-pressed and the simulated heat-treated material with full firings for a final restoration. The three-point bending test and the scanning electron microscope (SEM) analysis was conducted for the purpose of this study. The flexure strength of group. 2 was significantly higher than that of group 1. However, there were no significant differences in strength among group 2, 3, and 4, and between group 1 and 4. The SEM micrographs of the lithium disilicate glass-ceramic showed the closely packed, multi-directionally interlocking microstructure of numerous lithium disilicate crystals protruding from the glass matrix. The crystals of the heat-pressed materials (group 2, 3, and.4) were a little denser and about two times bigger than those of the as-received material (group 1). This change of microstructure is more obviously exhibited particularly between group 1 and 2. However, there was no a marked difference among group 2, 3, and 4 after the heat pressing procedure. Although there were significant increase of the strength and some changes of the microstructure after the heat-pressing operation, the conr bination of the heat-pressing and the simulated subsequent heat treatments did not produce the increase of strength of IPS Empress 2 glass-ceramic.


Sujets)
Incendies , Verre , Température élevée , Lithium
5.
The Journal of Korean Academy of Prosthodontics ; : 595-605, 2000.
Article Dans Coréen | WPRIM | ID: wpr-151159

Résumé

Dental ceramics have good aesthetics, biocompatibility, low thermal conductivity, abrasion resistance, and color stability. However, poor resistance to fracture and shrinkage during firing process have been limiting factors in their use, particularly in multiunit ceramic restorations. A new method for making all-ceramic crowns that have high strength and low processing shrinkage has been developed and is referred to as the Vita In-Ceram method. This study was performed to investigate the effect of Ce02 addition in borosilicate glasses on the strength of alumina-glass composites. Porous alumina compacts were prepared by slip casting and sintered at 1,100 degrees C for 2 hours. Dense composites were made by infiltration of molten glass into partially sintered alumina at 1,140 C for 4 hours. Specimens were polished sequentially from #800 to #2000 diamond disk, and the final surface finishing on the tensile side was received an additional polishing sequence through 1,cm diamond paste. Biaxial flexure test was conducted by using ball-on-three-ball method at a crosshead speed of 0.5mm/min. To examine the microstructural aspect of crack propagation in the alumina-glass composites, Vickers-produced indentation crack was made on the tensile surface at a load of 98.0 N and dwell time of 15 sec, and the radial crack patterns were examined by an optical microscope and a scanning electron microscope. The results obtained were summarized as follows ; 1. The porosity rates of partially sintered alumina decreased with the rising of firing temperature. 2. The maximum biaxial flexure strength of 423.5MPa. in alumina-glass composites was obtained with an addition of 3 mol% Ce02 in glass composition and strength values showed the aspect of decrease with the increase of Ce02 content. 3. The biaxial flexure strength values of alumina-glass composites were decreased with rising the firing temperature. 4. Observation of the fracture surfaces of alumina-glass composites indicated that the enhancement of strength in alumina-glass composites was due to the frictional or geometrical interlocking of rough fracture surfaces and ligamentary bridging by intact islands of materials left behind the fracture front.


Sujets)
Oxyde d'aluminium , Céramiques , Couronnes , Diamant , Esthétique , Lunettes correctrices , Incendies , Friction , Verre , Iles , Porosité , Conductivité thermique
6.
Journal of Practical Stomatology ; (6)1996.
Article Dans Chinois | WPRIM | ID: wpr-542830

Résumé

0.05),respectively.Conclusion:LED curing light can reach the performance level of halogen curing light and is suitable for routine oral clinical application for resin curing.