Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 2.232
Filtre
1.
Rev.Chil Ortop Traumatol ; 65(1): 9-15, abr.2024. ilus
Article Dans Espagnol | LILACS | ID: biblio-1554939

Résumé

INTRODUCCION En los últimos años, se ha descrito el uso de placas horizontales para la fijación de fracturas que comprometen el reborde articular de los platillos tibiales, lo que se conoce como placa rim. La mayoría de las publicaciones al respecto describen su uso en columnas posteriores y posterolaterales de los platillos tibiales, y a la fecha hay escasos reportes del uso de este tipo de placa en la columna anteromedial y ninguno para la posteromedial. El objetivo de este artículo es presentar dos casos clínicos de fracturas conminutas del platillo tibial medial mostrando su tratamiento con el uso de placas rim. CASOS CLINICOS El primer caso presentaba compromiso anteromedial y posteromedial, y el segundo, compromiso posteromedial. En ambos casos, se logró la reducción mediante un abordaje posteromedial y su fijación con placa bloqueada de 2,7 mm como placa rim. En cada caso, se detalló la estrategia de reducción y el manejo postoperatorio. RESULTADOS Ambos pacientes consiguieron la consolidación ósea entre las semanas 14 y 18 tras la osteosíntesis definitiva, sin presentar pérdidas de reducción. Ambos lograron rango de movilidad articular completo (0°­125°), y retornaron a sus trabajos a los 4 y 6 meses respectivamente. CONCLUSIONES Estas placas ofrecen una buena opción de tratamiento para fracturas articulares conminutas del borde del platillo tibial, tanto en la columna anteromedial como en la posteromedial. A pesar de la ausencia de grandes series de pacientes con uso de placas rim mediales, el resultado de los casos presentados aquí nos permite plantear su utilidad al momento de enfrentarnos a fracturas del reborde articular


INTRODUCTION In recent years, the use of horizontal plates has been described to achieve fixation of fractures that compromise the articular ridge of the tibial plateau; these plates are known as "rim plates." Most publications report their use in the posterior and posterolateral columns of the tibial plateau, and to date there are few reports of its use for the fixation of the anteromedial column and none for the posteromedial column. The objective of the present article is to report two clinical cases of comminuted fractures of the medial tibial plateau, showing their treatment with the use of medial rim plates. CLINICAL CASES The first case presented with an anteromedial and posteromedial tibial plateau fracture, and the second, a posteromedial fracture. In both cases, reduction was achieved through a posteromedial approach, and the fixation was performed with a 2.7-mm locked rim plate. The reduction strategy and postoperative management were detailed in each case. RESULTS Both patients achieved bone consolidation during the 14th and 18th weeks after the definitive osteosynthesis, without presenting loss of reduction. Both patients achieved full range of joint motion (0°­125°) and returned to work after four and six months respectively. CONCLUSION These plates offer a good treatment option for comminuted fractures of the rim of the tibial plateau, for both the anteromedial and posteromedial columns. Despite the absence of large series of patients with the use of medial rim plates, the results of the two cases herein presented enables us to propose it as a useful tool when dealing with fractures of the medial rim of the tibial plateau


INTRODUCTION In recent years, the use of horizontal plates has been described to achieve fixation of fractures that compromise the articular ridge of the tibial plateau; these plates are known as "rim plates." Most publications report their use in the posterior and posterolateral columns of the tibial plateau, and to date there are few reports of its use for the fixation of the anteromedial column and none for the posteromedial column. The objective of the present article is to report two clinical cases of comminuted fractures of the medial tibial plateau, showing their treatment with the use of medial rim plates. CLINICAL CASES The first case presented with an anteromedial and posteromedial tibial plateau fracture, and the second, a posteromedial fracture. In both cases, reduction was achieved through a posteromedial approach, and the fixation was performed with a 2.7-mm locked rim plate. The reduction strategy and postoperative management were detailed in each case. RESULTS Both patients achieved bone consolidation during the 14th and 18th weeks after the definitive osteosynthesis, without presenting loss of reduction. Both patients achieved full range of joint motion (0°­125°) and returned to work after four and six months respectively. CONCLUSION These plates offer a good treatment option for comminuted fractures of the rim of the tibial plateau, for both the anteromedial and posteromedial columns. Despite the absence of large series of patients with the use of medial rim plates, the results of the two cases herein presented enables us to propose it as a useful tool when dealing with fractures of the medial rim of the tibial plateau


Sujets)
Humains , Mâle , Adulte d'âge moyen , Fractures du tibia/chirurgie , Fractures du tibia/imagerie diagnostique , Tomodensitométrie/méthodes , Fractures comminutives/chirurgie , Fractures comminutives/imagerie diagnostique , Ostéosynthèse interne/méthodes , Post-cure
2.
Article Dans Chinois | WPRIM | ID: wpr-1021998

Résumé

BACKGROUND:There is currently no anatomic locking plate suitable for the anteromedial platform,so the medial locking plate of the tibial plateau is usually placed forward to fix anteromedial compression fractures caused by hyperextension varus injury.Due to the inability of the locking screw to achieve vertical fixation of the fracture line,coupled with the influence of the patellar ligament,the clinical results are still unsatisfactory. OBJECTIVE:To compare the biomechanical performance of a new type of plate with traditional internal fixation methods in treating hyperextension varus tibial plateau fractures through finite element analysis. METHODS:CT data of 20 cases of hyperextension varus tibial plateau fractures were collected,and their morphological characteristics,such as medial posterior tibial slope,the medial articular fracture angle,surface area,and anterior cortical height were measured.A 24-year-old male volunteer with a height of 175 cm and a weight of 65 kg was selected,and his tibial CT data were imported into Mimics 21.0 software to generate a 3D model.Then,internal fixation models were imported into SolidWorks 2017 software.New type of plate,medial locking plate,posterior medial locking plate,and 6.5 mm hollow screws fixed data models were established based on the measured morphological data.Ansys 17.0 software was used to load stress on the four fixation models and compare their biomechanical performance. RESULTS AND CONCLUSION:(1)With the increase of axial load,the peak stresses of different internal fixation models approximately increased proportionally.At 500 N,the peak stress values were as follows:screw group(6.973 7 MPa)<new steel plate group(14.733 MPa)<medial locking plate group(16.445 MPa)<posterior medial locking plate group(25.199 MPa).(2)The peak stresses of the fracture block were as follows:at 500 N,screw group(3.657 9 MPa)<new steel plate group(4.510 8 MPa)<medial locking plate group(5.225 9 MPa)<posterior medial locking plate group(6.181 2 MPa).(3)With the increase of axial load,the displacement of the fracture block and internal fixation approximately increased proportionally,and the displacement distribution characteristics showed no significant changes.At 500 N,the steel plate displacement values were as follows:new steel plate group(1.030 7 mm)<medial locking plate group(1.503 mm)<screw group(2.096 5 mm)<posterior medial locking plate group(2.258 2 mm).At 500 N,the fracture block displacement values were as follows:new steel plate group(0.212 8 mm)<medial locking plate group(0.311 54 mm)<screw group(0.427 79 mm)<posterior medial locking plate group(0.454 98 mm).(4)It is concluded that in the treatment of hyperextension varus tibial plateau fractures,the stability and mechanics of the new steel plate are superior to traditional internal fixation methods.

3.
International Journal of Surgery ; (12): 159-165, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1018107

Résumé

Objective:To compare the safety and efficacy of two different minimally invasive approaches to implant pedicle screw for the treatment of single-segment thoracolumbar spine fractures without nerve injury.Methods:This was a retrospective study. Eighty patients with mono-segmental thoracolumbar fractures treated with minimally invasive pedicle screw fixation at Beijing Friendship Hospital, Capital Medical University from January 2020 to June 2022 were included. There were 46 males and 36 females, the age was (45.93±7.91) years old, and ranged from 27 to 60 years old. They were divided into two groups according to different surgical techniques: percutaneous pedicle screw fixation group ( n=44) and Wiltse approach group ( n=36). The operative time, operative visible blood loss, hidden blood loss, total blood loss, fluoroscopy times, incision length, hospital time after surgery and ambulation time were compared. Visual analogue scale (VAS), Oswestry disability index (ODI), ratio of the vertebral anterior height, angle of injured vertebral endplate were recorded and compared between two groups before surgery and at 3 days, 6 months and 1 year after surgery. The accuracy of pedicle screw position and the facet joint violation rate were evaluated by using the postoperative CT scan. Perioperative related complications were investigated. Normally distributed numerical data were presented as mean ± standard deviation, and differences between the groups were compared using t-test. The counting data were expressed as percentages or rates and compared using χ2 test. Results:All patients were followed for a minimum of 12 months. There is no significant difference between the two groups in intraoperative visible blood loss, hospital time after surgery, ambulation time, postoperative VAS and ODI, ratio of vertebral anterior height and angle of injured vertebral endplate at 3 days after surgery, pedicle screw position accuracy and perioperative complications ( P>0.05). The operative time, hidden blood loss, total blood loss, intraoperative fluoroscopy times, facet joint violation rate in the percutaneous pedicle screw fixation group were remarkably higher than in the Wiltse approach group ( P<0.05). The ratio of vertebral anterior height in the percutaneous pedicle screw fixation group was dramatically lower than in the Wiltse approach group at 6 months and 1 year after surgery ( P<0.05). The postoperative injured vertebral endplate angle was higher in the percutaneous pedicle screw fixation group than that in the Wiltse approach group at 6 months and 1 year ( P<0.05). Conclusions:Both percutaneous pedicle screw fixation and Wiltse approach were safe and effective minimally invasive surgical procedures for the treatment of thoracolumbar fractures without neurological injury. The Wiltse approach can reduce fluoroscopy times and perioperative hidden blood loss, reduce the risk of facet joint violation, and maintain a better reduction than percutaneous pedicle screw fixation.

4.
International Journal of Surgery ; (12): 207-211, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1018116

Résumé

Femoral intertrochanteric fracture is one of the common types of fractures in the elderly. With the general improvement of medical and living standards, the number of elderly people is increasing, and the problem of osteoporosis has also become relatively prominent. Therefore, low violence can usually cause fractures in this area of the elderly, which has a significant negative impact on the quality of life of elderly patients. With the further development of medical technology and internal fixation materials, the emergence of proximal femoral nail antirotation(PFNA) has greatly improved the treatment effect of femoral intertrochanteric fractures in elderly patients. However, with the increasing number of patients treated, internal fixation failures have gradually been reported. In recent years, proximal femoral biomimetic intramedullary nail(PFBN) has been reported to have good clinical efficacy. Therefore, this article mainly elaborates on the theoretical basis, design characteristics, biomechanics, and clinical efficacy research of PFBN, providing more reference for the clinical treatment of femoral intertrochanteric fractures in elderly patients in the future.

5.
Article Dans Chinois | WPRIM | ID: wpr-1021331

Résumé

BACKGROUND:Accurate reduction of ankle fractures under direct vision has become a common understanding among foot and ankle surgeons.How to fully expose free or compressed fragments of the posterior ankle remains one of the most challenging problems. OBJECTIVE:To explore the clinical efficiency of the para-Achilles tendon approach in exposing and repositioning the posterior malleolus sandwich fracture. METHODS:A retrospective study was made for 26 patients with posterior malleolus sandwich fracture treated with open reduction and internal fixation via para-Achilles tendon approach from January to December 2020 in The Second People's Hospital of Dalian.21 of 26 cases were managed with the lateral approach of Achilles tendon and 5 cases were managed with the medial approach of Achilles tendon.There were 19 males and 7 females,with the age of 24-69 years,averagely 38.6 years.The operation time and postoperative complications were recorded.The fracture reduction condition was evaluated by Burwell-Charnley imaging standard.Before operation,3 months after operation and last follow-up,visual analog scale score,ankle plantar flexion and dorsiflexion and American Orthopedic Foot&Ankle Society Ankle Hind Score were used to evaluate the treatment effect. RESULTS AND CONCLUSION:(1)All 26 patients were followed up for an average of 14.6 months(range 13-18 months).The operation time was 52-85 minutes(average 64.2 minutes).(2)Part of the skin edge of the lateral malleolus incision was necrotic in one patient and healed completely after a dressing change.Incision healing of the other patients was in one stage.(3)Through Burwell-Charnley imaging standard,anatomical reductions were obtained in 24 of 26,and good reductions were in 2 of 26,with an excellent and good rate of 100%.(4)At the last follow-up,the visual analog scale score(1.19±0.40)was significantly lower than the preoperative score(6.81±0.80)(P<0.01).Ankle plantar flexion(33.5±5.02)° and ankle plantar back stretch(17.23±0.99)° were significantly increased compared with preoperative data(14.58±2.50)° and(5.81±1.02)°(P<0.01).American Orthopedic Foot&Ankle Society Ankle Hind Score was improved to(89.31±3.62)points compared to preoperative(46.00±5.45)points(P<0.01).The results were excellent in 23 patients and good in 3 patients,with an excellent and good rate of 100%.(5)It is concluded that the open reduction and internal fixation via the para-Achilles tendon approach for the treatment of posterior malleolus sandwich fracture were efficient with decreased operation time,satisfying fracture reduction,fewer complications,satisfactory motion range,and functional recovery.

6.
Article Dans Chinois | WPRIM | ID: wpr-1009226

Résumé

OBJECTIVE@#To compare the role and importance of fibular fixation in tibiofibular fractures by Meta-analysis.@*METHODS@#The literature related to the comparison of the efficacy of fixation of the fibula with or without fixation on the treatment of tibiofibular fractures was searched through the databases of China Knowledge Network, Wipu, Wanfang, The Cochrane Library, Web of science and Pubmed, and statistical analysis was performed using RevMan 5.3 software. The rates of malrotation, rotational deformity, internal/external deformity, anterior/posterior deformity, non-union, infection, secondary surgery and operative time were compared between the fibula fixation and non-fixation groups.@*RESULTS@#A total of 11 publications were included, six randomised controlled trials and five case-control trials, eight of which were of high quality. A total of 813 cases were included, of which 383 were treated with fibula fixation and 430 with unfixed fibulae.Meta-analysis results showed that fixation of the fibulae in the treatment of tibiofibular fractures reduced the rates of postoperative rotational deformity[RR=0.22, 95%CI(0.10, 0.45), P<0.000 1] and internal/external deformity[RR=0.34, 95%CI(0.14, 0.84), P=0.02] and promoted fracture healing [RR=0.76, 95%CI(0.58, 0.99), P=0.04]. In contrast, the rates of poor reduction [RR=0.48, 95% CI(0.10, 2.33), P=0.36], anterior/posterior deformity[RR=1.50, 95%CI(0.76, 2.96), P=0.24], infection[RR=1.43, 95%CI(0.76, 2.72), P=0.27], secondary surgery[RR=1.32, 95%CI(0.82, 2.11), P=0.25], and operative time[MD=10.21, 95%CI(-17.79, 38.21), P=0.47] were not statistically significant (P>0.05) for comparison.@*CONCLUSION@#Simultaneous fixation of the tibia and fibula is clinically more effective in the treatment of tibiofibular fractures.


Sujets)
Humains , Fibula/chirurgie , Fractures osseuses/complications , Tibia/chirurgie , Consolidation de fracture , Ostéosynthèse interne , Résultat thérapeutique
7.
Article Dans Chinois | WPRIM | ID: wpr-1024260

Résumé

Objective:To investigate the clinical efficacy of two different internal fixations in the treatment of femoral intertrochanteric fractures in older adult patients.Methods:The clinical data of 152 older adult patients with femoral intertrochanteric fractures who were treated at the Second People's Hospital of Hefei from January 2019 to December 2022 were retrospectively analyzed. All patients underwent closed reduction and internal fixation surgery. They were divided into two groups based on the different types of internal fixations used. Among them, 76 patients received internal fixation using proximal femoral intramedullary nails (group A), while 76 patients received internal fixation using Intertan nails (group B). The intraoperative blood loss volume, surgical time, postoperative complications, fracture healing time, and hip joint function score were compared between the two groups.Results:The intraoperative blood loss volume in group A was (197.11 ± 37.85) mL, which was significantly less than that in group B [(226.84 ± 54.17) mL, t = 1.62, P < 0.001]. Surgical time in group A was (71.16 ± 15.64) minutes, which was significantly shorter than that in group B [(78.49 ± 15.88) minutes, t = 1.67, P < 0.001]. The fracture healing time in group A was (13.29 ± 0.94) weeks, which was not significantly different from that in group B [(13.20 ± 0.64) weeks, t = 0.33, P > 0.05]. However, the incidence of postoperative complications in group A was 5.26% (4/76), which was significantly higher than 1.32% (1/76) in group B ( χ2 = 4.04, P = 0.048). At 1 and 3 months and 1 year after surgery, the hip joint function score in group A was (63.13 ± 2.41) points, (73.50 ± 3.99) points, and (84.13 ± 7.57) points, respectively, and it was (68.65 ± 2.65) points, (79.07 ± 3.38) points, and (89.56 ± 7.71) points, respectively, in group B. At the above-mentioned time points, the difference in hip joint function score between the two groups was statistically significant ( t = 1.89, 2.48, 2.49, all P < 0.001). Conclusion:Both internal fixation methods have significant therapeutic effects on femoral intertrochanteric fractures. Internal fixation using Intertan nails leads to higher hip joint function scores and fewer postoperative complications compared with internal fixation using proximal femoral intramedullary nails, but it results in more blood loss and a longer surgical time.

8.
Chinese Journal of Trauma ; (12): 146-153, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1027019

Résumé

Objective:To compare the biomechanical properties of the modified and traditional iliolumbar pedicle screw-rod system for the fixation of vertically unstable posterior pelvic ring dislocation.Methods:The CT images of the lumbar spine, pelvis, and femur from a 31-year-old healthy male volunteer were used to establish models of posterior pelvic ring dislocation and unilateral and bilateral fixation models of modified and traditional iliolumbar pedicle screw-rod systems with the three-dimensional virtual software using the finite element method. By restraining the distal ends of the femurs of both sides and applying a vertical load of 500 N to the L 1 vertebral body, the maximum stress of the intact pelvis model and the stiffness of the posterior pelvic ring dislocation model were evaluated to validate the reliability of the models. After the validation of the models, a follower load of 400 N was applied in the direction of the L 1 vertebral curve to simulate the upper body weight; the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum of the modified and traditional iliolumbar pedicle screw-rod system models were compared. Additionally, stress distributions of the implant and the pelvis were also compared. Results:(1) The maximum stress of the intact pelvis model was 22.0 MPa, with the stiffness of the posterior pelvic ring dislocation model as 180.03 N/mm. (2) In terms of the maximum vertical displacement of the sacrum, the bilateral modified iliolumbar pedicle screw-rod system was similar to the bilateral traditional iliolumbar pedicle screw-rod system. However, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the bilateral modified iliolumbar pedicle screw-rod system were 0.57 mm, 0.19 mm and 0.68 mm respectively, which were markedly smaller than those of the bilateral traditional iliolumbar pedicle screw-rod system (1.38 mm, 0.26 mm and 1.41 mm respectively). (3) The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the unilateral modified iliolumbar pedicle screw-rod system were 0.70 mm, 0.73 mm, 0.17 mm and 0.88 mm respectively, which were markedly smaller than those of the unilateral traditional iliolumbar pedicle screw-rod system (1.17 mm, 2.21 mm, 0.31 mm and 2.29 mm respectively). (4) The stress of the implant was concentrated on the connecting rod between the iliac pedicle screw-rod and the lumbar pedicle screw-rod in the modified iliolumbar pedicle screw-rod system, but it was mainly concentrated on the connecting rod at the upper edge of the iliac screw in the traditional iliolumbar pedicle screw-rod system. The maximum stress of the implant was 340.84 MPa in the bilateral modified iliolumbar pedicle screw-rod system, which was 30.4% less than that in the bilateral traditional iliolumbar pedicle screw-rod system (489.77 MPa), and was 351.23 MPa in the unilateral modified iliolumbar pedicle screw-rod system, which was 15.5% less than that in the unilateral traditional iliolumbar pedicle screw-rod system (415.82 MPa). (5) In both modified and traditional iliolumbar pedicle screw-rod systems, the stress of the pelvis was concentrated on the contact area between the iliac screw and the cortical bone. The maximum stress of the pelvis was 19.21 MPa in the bilateral modified iliolumbar pedicle screw-rod system, which was 78.1% less than that in the bilateral traditional iliolumbar pedicle screw-rod system (87.59 MPa), and was 39.91 MPa in the unilateral modified iliolumbar pedicle screw-rod system, which was 70.4% less than that in the unilateral traditional iliolumbar pedicle screw-rod system (134.98 MPa).Conclusion:Compared with the traditional iliolumbar pedicle screw-rod system, the modified iliolumbar pedicle screw-rod system can effectively reduce the displacements of all directions in vertically unstable posterior pelvic ring dislocation and significantly reduce the stress of the implant and the pelvis, thus having good biomechanical stability.

9.
Chinese Journal of Trauma ; (12): 206-213, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1027025

Résumé

Objective:To investigate the long-term efficacy of self-designed posterior atlas polyaxial screw-plate in the treatment of unstable atlas fracture.Methods:A retrospective case series study was conducted to analyze the clinical data of 20 patients with unstable atlas fracture who were admitted to Affiliated Honghui Hospital of Xi′an Jiaotong University from January 2011 to April 2013, including 14 males and 6 females, aged 23-60 years [(42.7±8.6)years]. All the patients were treated with internal fixation using self-designed posterior atlas polyaxial screw-plate. The operation time and intraoperative bleeding volume were recorded. The fracture reduction was evaluated by CT scan at 3 days after surgery. The bone healing was observed by X-ray (anterior-posterior and lateral views of the cervical spine) and CT scan at 9 months after surgery. The delayed spinal cord injuries were evaluated by Frankel grade at 1 and 2 years after surgery and at the last follow-up. The Visual Analogue Scale (VAS) before surgery, at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. The axial rotation, flexion and extension range of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. Intraoperative and postoperative complications were observed.Results:All the patients were followed up for 121-148 months [(135.0±6.8)months]. The operation duration was 68-122 minutes [(86.0±14.1)minutes], with the intraoperative blood loss of 90-400 ml [(120.0±67.9)ml]. The CT scan of the cervical spine at 3 days after surgery showed all satisfactory fracture reduction. Satisfactory bone reunion was observed at 9 months after surgery. All patients were scaled as Frankel grade E at 1 year, 2 years and at the last follow-up after surgery, with no delayed spinal cord injuries observed. The VAS scores of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were 2.0(1.3, 3.0)points, 1.0(1.0, 1.8)points, 1.0(0.3, 1.0)points and 1.0(0.3, 1.0)points, which were significantly lower than that before surgery [7.0(6.0, 7.8)points] ( P<0.05), with significantly lower scores at 1-, 2-year after surgeny and at the last follow-up than at 3 months after surgery ( P<0.05). There were no significant differences among the other time points ( P>0.05). The axial rotation ranges of the cervical spine were (103.0±8.3)°, (128.3± 11.4)° and (129.8±13.6)° at 1 year, 2 years after surgery and at the last follow-up respectively, which were significantly higher than that at 3 months after surgery [(85.3±7.0)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference at the last follow-up compared with that at 2 years after surgery ( P>0.05). The flexion and extension range of the cervical spine at 1 year, 2 years after surgery and at the last follow-up were (65.5±4.8)°, (78.3±6.5)° and (79.3±6.9)° respectively, which were significantly higher than that at 3 months after surgery [(54.3±4.4)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference between the last follow-up and 2 years after surgery ( P>0.05). No intraoperative injuries such as arteriovenous injury were observed. No incision infection or dehiscence occurred after surgery, with no complications caused by long-term bed rest such as lung or urinary tract infection, pressure sore formation or deep vein thrombosis occurred. No loosening or breakage of the screw and atlas plate was observed at the long-term follow-up. One patient had mild cervical pain, snap during rotation, and limited range of motion at the last follow-up. Conclusion:Self-designed posterior atlas polyaxial screw-plate has merits including small surgical wounds, satisfactory reduction, solid fixation, obvious pain relief, effective preservation of the previous cervical motion, few complications, and satisfactory long-term efficacy in the treatment of unstable atlas fracture.

10.
Chinese Journal of Trauma ; (12): 221-228, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1027027

Résumé

Objective:To compare the efficacy of the horizontal plate plus raft screws above the acetabulum and fixation with screws only for acetabular fractures combined with dome impaction in the aged patients.Methods:A retrospective cohort study was conducted to analyze the clinical data of 20 aged patients with acetabular fractures combined with dome impaction, who were admitted to Tianjin hospital between May 2013 and January 2023, including 5 males and 15 females, aged 61-84 years [(72.2±7.3)years]. According to Letournel and Judet classification, 13 patients had anterior column fracture, 5 anterior column fracture combined with posterior transverse fracture and 2 two-column fracture. All the patients underwent open reduction and internal fixation through an anterior approach. Of them, 11 patients were treated with the fixation with the horizonal plate plus raft screws above the acetabulum (plate plus raft screw group) and 9 with the screws only (screw only group). The operative time, intraoperative blood loss, and intraoperative fluoroscopy times were compared between the two groups. The quality of fracture reduction was evaluated with the Matta′s radiographic criteria at 3 days after surgery and the function of the hip joint was assessed with Merle D′Aubigné and Postel scoring system at 3 months after surgery and at the last follow-up as well as the excellent and good rate at te last follow-up. The occurrence of postoperative complications was observed.Results:All the patients were followed up for 6-18 months [(13.1±3.1)months]. There were no significant differences in the operative time, intraoperative blood loss or intraoperative fluoroscopy times between the two groups ( P>0.05). According to the Matta′s radiographic criteria at 3 days after surgery, patients with anatomical reduction and satisfactory reduction accounted 6 and 5 in the plate plus raft screw group, compared to 5 and 4 respectively in the screw only group ( P>0.05). The values of Merle D′Aubigné and Postel score at 3 months after surgery and at the last follow-up were (14.0±2.4)points and (15.8±2.2)points in the plate plus raft screw group, which were higher than those in the screw only group [(11.0±2.6)points and (13.0±3.1)points] ( P<0.01). The values of Merle D′Aubigné and Postel score at the last follow-up of both groups were further enhanced from those at 3 months after surgery ( P<0.01). At the last follow-up, 3 patients were rated excellent, 6 good, 1 fair and 1 poor in the plate plus raft screw group, with an excellent and good rate of 81.8%, while in the screw only group, 3 were rated good, 2 fair and 4 poor, with an excellent and good rate of 33.3% ( P<0.05). One patient in the plate plus raft screw group and 5 in the screw only group had displacement of the dome impaction fragment combined with traumatic arthritis after surgery ( P<0.05). Conclusion:For acetabular fractures combined with dome impaction in the aged patients, the horizontal plate plus raft screw above the acetabulum can effectively improve the function restoration of the hip joint and reduce the occurrence of the displacement of the dome impaction fragment and traumatic arthritis after surgery compared to the fixation with screws only.

11.
Article Dans Chinois | WPRIM | ID: wpr-1027091

Résumé

Objective:To evaluate the reliability of a region-locked 3D-printed template combined with a bi-directional matching scheme in assistance of screw placement for thoracolumbar fractures.Methods:From January 2019 to March 2023, 52 patients with thoracolumbar fracture were treated at Department of Orthopedics, The People's Hospital of Liyang. They were 29 males and 23 females, with an age of (58.2±13.3) years. They were divided into a template group and a free-hand group according to the different screw placements. In the template group of 25 cases, a region-locked 3D-printed template combined with a bi-directional matching scheme was used to assist the pedicle positioning; in the free-hand group of 27 cases, the free hand screw placement was assisted only by image data and C-arm fluoroscopy. The operation time, intraoperative fluoroscopy frequency, intraoperative blood loss, complications, and placement accuracy were compared between the 2 groups. Visual analogue scale (VAS), Oswestry disability index (ODI), and anterior height ratio of the injured vertebra were compared between preoperation, 1 week postoperation, and the final follow-up, as well as between the 2 groups.Results:There were no statistically significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (11.2±4.2) months. The differences were not statistically significant between the 2 groups in intraoperative blood loss, rate of complications, VAS or ODI at preoperation, 1 week postoperation, or the final follow-up, or in anterior height ratio of the injured vertebra ( P>0.05). In the template group, the operation time [(80.1±18.5) min] was significantly longer than that in the free-hand group [(69.4±16.6) min], the intraoperative fluoroscopy frequency [2 (2, 3) times] significantly lower than that in the free-hand group [3 (3, 4) times], and the placement accuracy [98.4% (127/129)] significantly higher than that in the free-hand group [91.8% (112/122)] (all P<0.05). All patients showed significant improvements in VAS, ODI and anterior height ratio of the injured vertebra at postoperative 1 week compared with the preoperative values, and the improvements at the last follow-up were significantly larger than those at postoperative 1 week ( P<0.05). No injury to the spinal cord, nerve root or blood vessel was observed postoperatively. Conclusions:In the treatment of thoracolumbar fractures, the screw placement assisted by a region-locked 3D-printed template combined with a bi-directional matching scheme is better than free-hand screw placement in terms of improved accuracy and reduced fluoroscopy, but the former incurs longer operative exposure than the latter. There is no significant difference between the 2 methods of screw placement in clinical efficacy.

12.
Article Dans Chinois | WPRIM | ID: wpr-1027099

Résumé

Objective:To compare the medium and long-term efficacy between the deltoid split approach and the conventional deltopectoral approach in locking plate fixation for proximal humerus fractures.Methods:A retrospective study was performed in the 65 patients with proximal humerus fracture who had been operatively treated at Department of Orthopedics, The Third People's Hospital of Nantong from January 2018 to December 2020. They were 20 males and 45 females with an age of (64.6±9.2) years. Of them, 34 were assigned to fixation with proximal humerus internal locking system (PHILOS) through the deltoid split approach (minimally invasive group), and 31 to PHILOS fixation through the deltopectoral approach (conventional group). The 2 groups were compared in terms of general data, operation time, intraoperative blood loss, hospital stay, fracture union time, intraoperative fluoroscopy, postoperative 2-year imaging scores, and Constant-Murley shoulder score at the last follow-up.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). In the minimally invasive group and the conventional group, respectively, the intraoperative blood loss was (97.9±16.6) mL and (155.8±27.4) mL, and the frequency of intraoperative fluoroscopy (12.0±1.8) times and (6.7±1.8) times, both showing a statistically significant difference ( P<0.05). There was no significant difference in operation time, hospital stay, or fracture union time ( P>0.05). All patients were followed up for (43.9±5.5) months. There was no statistically significant difference between the 2 groups in postoperative 2-year imaging scores ( P>0.05). Compared with the conventional group, patients in the minimally invasive group had significantly lower Constant-Murley strength scores and significantly lower Constant-Murley scores for the Neer four-part fractures ( P<0.05). Postoperatively, one case of screw protrusion and one case of complete ischemic necrosis occurred in both groups while one case of partial ischemic necrosis was observed in the minimally invasive group and 3 cases of partial ischemic necrosis were observed in the conventional group. Conclusions:In locking plate fixation for proximal humerus fractures, compared with the deltopectoral approach, the deltoid split approach shows advantages of less soft tissue damage, less intraoperative bleeding, and less destruction of the blood supply to the humeral head. However, the deltopectoral approach may be more appropriate for the Neer four-part fractures.

13.
Article Dans Chinois | WPRIM | ID: wpr-1027103

Résumé

Objective:To explore the clinical effectiveness of a self-designed robot reduction system for femoral intertrochanteric fractures.Methods:A retrospective study was conducted to analyze the 57 patients with intertrochanteric fracture who had been treated at Department of Orthopedics, The Fourth Affiliated Central Hospital of Tianjin Medical University from June 2022 to February 2023. The patients were divided into a robot group (using the self-designed robot reduction system to assist intramedullary nailing) and a traction bed group (using a traction bed to assist intramedullary nailing) based on their fracture reduction method. The robot group: 31 patients, 11 males and 20 females, with an age of (78.7±9.3) years; 16 left and 15 right sides; 17 cases of type 31-A1, 12 cases of type 31-A2 and 2 cases of type 31-A3 by the AO/OTA classification. The traction bed group: 26 patients, 12 males and 14 females, with an age of (78.7±7.7) years; 13 left and 13 right sides; 16 cases of type 31-A1, 9 cases of type 31-A2 and 1 cases of type 31-A3 by the AO/OTA classification. The 2 groups were compared in terms of reduction and operation time, intraoperative blood loss, fluoroscopy frequency, reduction quality, and VAS and Harris score at preoperation, 1 week and 6 months postoperation.Results:The 2 groups were comparable due to insignificant differences in their preoperative general data ( P>0.05). The robot group was significantly better than the traction bed group in reduction time [(4.4±2.2) min versus (9.4±3.2) min], operation time [(29.0±13.5) min versus (49.3±13.3) min], intraoperative blood loss [(76.5±30.5) mL versus (115.0±38.4) mL], fluoroscopy frequency [(10.2±2.6) times versus (14.8±3.2) times], and good/excellent rate of reduction [80.6% (25/31) versus 50.0% (13/26)] ( P<0.05). All patients were followed up for (6.8±0.3) months. Respectively, the VAS scores at preoperation and 6 months postoperation was (6.2±1.3) and (2.4±0.8) points for the robot group, and (6.3±1.3) and (2.7±0.8) points for the traction bed group, showing no statistically significant differences between the 2 groups ( P>0.05). However, the VAS score was (3.3±1.2) points for the robotic group and (4.8±1.5) points for the traction bed group at 1 week postoperation, showing a statistically significant difference between the 2 groups ( P<0.001). Respectively, the Harris scores at preoperation and 6 months postoperation were (35.3±3.0) and (88.7±3.4) points for the robot group, and (35.6±2.9) and (87.2±3.5) points for the traction bed group, showing no statistically significant differences between the 2 groups ( P>0.05). However, the Harris score was (57.3±3.7) points for the robotic group and (46.7±2.8) points for the traction bed group at 1 week postoperation, showing a statistically significant difference between the 2 groups ( P<0.05). The patient satisfaction rates in the robot and traction bed groups were 96.8% (30/31) and 92.3% (24/26), respectively, showing no statistically significant difference ( P>0.05). Conclusion:Our self-designed robot reduction for femoral intertrochanteric fractures can effectively shorten reduction and operation time, reduce bleeding and fluoroscopy frequency, and enhance anatomical reduction.

14.
Article Dans Chinois | WPRIM | ID: wpr-1027104

Résumé

Objective:To evaluate our self-designed pre-positioned 3D honeycomb guide device in the internal fixation with percutaneous cannulated screws for femoral neck fractures.Methods:A retrospective study was conducted to analyze the data of 60 patients with femoral neck fracture who had been treated with cannulated screw fixation at Department of Orthopaedics, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Nanjing University of Traditional Chinese Medicine from June 2019 to June 2022. According to the difference in intraoperative positioning for placement of cannulated screws, the patients were divided into a study group of 30 cases whose placement of cannulated screws was assisted by our self-designed pre-positioned 3D honeycomb guide device, and a control group of 30 cases whose cannulated screws were positioned freehand. In the study group, there were 17 males and 13 females with an age of (44.9±9.2) years, and 2 cases of type Ⅱ, 18 cases of type Ⅲ, and 10 cases of type Ⅳ by the Garden classification. In the control group, there were 11 males and 19 females with an age of (43.5±7.9) years), and 1 case of type Ⅱ, 16 cases of type Ⅲ, and 13 cases of type Ⅳ by the Garden classification. Closed reduction and inverted triangle internal fixation with 3 cannulated screws were conducted for all fractures. The Garden crossline index, operation time, fluoroscopy frequency, needle drillings, fracture healing time, and Harris hip functional score at the last follow-up were compared between the 2 groups. The postoperative imaging indicators in the 2 groups were measured, including screw spacing, distance from screw to neck cortex, screw coverage area, parallel deviation between screws, and deviation from screw to neck axis.Results:There were no statistically significant differences in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (14.4±1.9) months after surgery. In the study group, operation time [(33.1±5.5) min], fluoroscopy frequency [(13.7±2.2) times], needle drillings [(3.7±0.6) times], distance from screw to neck cortex [(12.4±2.8) mm], parallel deviation between screws in the anteroposterior view (2.2°±1.1°), parallel deviation between screws in the lateral view (2.4°±1.0°), deviation from screw to neck axis in the anteroposterior view (4.0°±0.9°) and deviation from screw to neck axis in the lateral view (3.2°±0.8°) were all significantly smaller than those in the control group [(46.5±8.6) min, (23.1±5.2) times, (11.0±2.2) times, (19.0±3.3) mm, 6.5°±2.6°, 7.1°±2.9°, 7.7°±2.6°, and 9.2°±3.1°] (all P<0.05). The screw spacing [(45.7±5.8) mm] and screw coverage area [(74.1±10.9) mm 2] in the study group were both significantly larger than those in the control group [(31.3±7.7) mm and (55.5±9.0) mm 2] ( P<0.05). There was no statistically significant difference between the 2 groups in Garden crossline index, fracture healing time, follow-up time, or Harris hip functional score at the last follow-up ( P>0.05). Follow-ups revealed 1 case of bone non-union in the study group and 2 cases of bone non-union and screw withdrawal in the control group, but no such complications as infection, deep vein thrombosis, screw penetration or rupture, or femoral head necrosis in either group. Conclusion:In the internal fixation with percutaneous cannulated screws for the treatment of femoral neck fractures, our self-designed pre-positioned 3D honeycomb guide device can shorten surgical time, significantly reduce fluoroscopy frequency and needle drillings, and effectively improve accuracy of screw placement.

15.
Article Dans Chinois | WPRIM | ID: wpr-1027107

Résumé

Objective:To evaluate the reliability and clinical application of a self-established classification system for the lower 1/3 humeral fractures in adults.Methods:A retrospective study was performed to analyze the 88 patients with lower 1/3 humeral fracture who had been admitted to Department of Orthopedics, The Second Hospital of Fuzhou between January 2013 and December 2020. There were 61 males and 27 females with an age of (34.6±12.7) years. The lower 1/3 humeral fractures were classified according to the location of the fracture line, displacement, and bone mass into 3 types: type Ⅰ: transverse and short oblique ones; type Ⅱ: oblique and spiral ones; type Ⅲ: oblique and spiral ones with butterfly-shaped bone mass. After a junior orthopedic surgeon, an intermediate orthopedic surgeon, a senior orthopedic surgeon, and a radiologist had learned this novel classification system, they were asked to classify the lower 1/3 humeral fractures in this cohort independently to assess the reliability of the classification system. Our treatments were based on this novel classification. Open reduction and internal fixation with a unilateral plate through a lateral approach was performed for type Ⅰ fractures, internal fixation with a unilateral plate plus compression screws through a lateral approach for type Ⅱ fractures, and double plate internal fixation through the ulnar and anterolateral approaches for type Ⅲ fractures. The functions of the radial, ulnar, and musculocutaneous nerves and fracture healing time were observed postoperatively. The shoulder and elbow functions were evaluated using Neer shoulder function score and Mayo elbow function score.Results:Of the 88 patients in this cohort, 20 were type Ⅰ, 25 type Ⅱ, and 43 type Ⅲ. The mean Kappa value for inter-observer reliability was 0.878 at the first stage and 0.914 at the second stage, and the mean Kappa value for intra-observer reliability was 0.950. All patients were followed up for (14.1±3.7) months. Iatrogenic injury to the radial nerve was observed in 2 patients, but no injury to the ulnar nerve, the musculocutaneous nerve or important blood vessels or failure of internal fixation was reported. All patients achieved bony union after (12.7±2.0) weeks. The maximum elbow flexion was 137.8°±4.8°, and the maximum elbow extension 2.4°±1.6°. The Mayo elbow function score was (92.0±3.1) points and the Neer shoulder function score (92.2±3.2) points.Conclusions:Our classification system for the lower 1/3 humeral fractures in adults is reliable. As the treatments corresponding to the novel classification system can achieve satisfactory clinical outcomes, the classification system has a clinical value.

16.
Article Dans Chinois | WPRIM | ID: wpr-1027109

Résumé

Objective:To compare the clinical outcomes between percutaneous Kirschner wire leverage plus plaster fixation and elastic intramedullary nailing in the treatment of radial neck fractures in children.Methods:A retrospective study was conducted to analyze the 60 children with radial neck fracture who had been treated by percutaneous Kirschner wire leverage plus plaster fixation at Department of Pediatric Orthopedics, Children's Hospital of Soochow University from January 2016 to July 2023 (set as an internal fixation-free group). They were 30 males and 30 females (34 left and 26 right sides) with an age of (7.7±3.0) years. At the same time, another cohort of 60 patients were chosen as an intramedullary nailing group who had been treated by percutaneous Kirschner wire leverage plus elastic intramedullary nailing and matched in age and gender with those in the internal fixation-free group. The preoperative fracture angulation, operative time, hospitalization time, fracture angulation on the first postoperative day, fracture angulation at 1 month postoperatively, rate of angulation loss after reduction, Mayo elbow performance score (MEPS) at the last follow-up and complications were compared between the 2 groups.Results:There was no significant difference between the 2 groups in their preoperative general data, showing comparability ( P<0.05). The 120 pediatric patients were followed up for (7.5±3.2) months. The operative time [(27.4±15.0) min] and hospitalization time [(3.4±1.9) d] in the internal fixation-free group were significantly shorter than those in the intramedullary nailing group [(45.4±13.5) min and (4.4±1.3) d] ( P<0.05). The preoperative fracture angulation (50.8°±1.9°), fracture angulation on the first postoperative day (11.3°±1.2°), fracture angulation at 1 month postoperatively (12.1°±1.3°), rate of angulation loss after reduction (2.9%±0.5%), and MEPS at the last follow-up [(90.4±2.0) points] in the internal fixation-free group showed no significant differences from those in the intramedullary nailing group [49.5°±1.7°, 11.1°±1.2°, 13.3°±1.5°, 3.9%±1.4%, and (90.2±2.3) points] ( P>0.05). None of the patients in the internal fixation-free group developed pin-tail irritation sign or premature epiphyseal closure after surgery, whereas 3 patients in the intramedullary nailing group developed pin-tail irritation sign and 2 ones premature epiphyseal closure after surgery, showing a significant difference in the complication rate between the 2 groups [0 (0/60) versus 8.3% (5/60)] ( P<0.05). Conclusions:Percutaneous Kirschner wire leverage plus plaster fixation and close elastic intramedullary nailing can both achieve satisfactory outcomes in the treatment of radial neck fractures in children. However, percutaneous Kirschner wire leverage plus plaster fixation needs shorter operative time and hospitalization time, leads to fewer complications, and requires no reoperation to remove internal fixation.

17.
Article Dans Chinois | WPRIM | ID: wpr-1027113

Résumé

Objective:To compare the clinical efficacy between a single palmar lateral transverse approach and the modified Henry approach in the locking plate fixation for distal radius fractures.Methods:A retrospective study was conducted to analyze the data of 82 patients with distal radius fracture who had undergone locking plate fixation through either a single palmar lateral approach or the modified Henry approach between January 2016 and December 2022 at Department of Traumatic Orthopaedics, Taihe Hospital, Affiliated to Hubei University of Medicine. There were 25 males and 57 females, with an age of (53.8±12.7) years. Based on the difference in surgical approach, the patients were divided into a single transverse approach group ( n=42) and a modified Henry approach group ( n=40). The 2 groups were compared in terms of injury cause, injury location, time from injury to surgery, AO fracture classification, tourniquet time during surgery, incision length, fracture reduction, Patient and Observer Scar Assessment Scale (PSAS & OSAS) and Disability of the Arm, Shoulder, and Hand (DASH) score at the last follow-up, and complications after surgery. Results:There were no statistically significant differences in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (8.2±3.5) months. Follow-ups revealed one case of injury to the palmar cutaneous branch of the median nerve but no other complications like infection, non-union, internal fixation failure, or tendon injury in the single transverse approach group. The single transverse approach group was significantly superior over the modified Henry approach group in incision length [(2.4±0.9) cm versus (5.3±1.6) cm], OSAS (8.1±4.2 versus 10.3±5.7), and PSAS (10.1±5.8 versus 14.7±6.4) ( P<0.05). There were no significant differences between the 2 groups in tourniquet time, fracture reduction quality, and DASH score at the last follow-up ( P>0.05). Conclusion:In locking plate fixation for distal radius fractures, in comparison with the modified Henry approach, a single palmar lateral approach is more minimally invasive so that more aesthetically pleasing outcomes can be achieved to facilitate patients' rapid return to work and society.

18.
Article Dans Chinois | WPRIM | ID: wpr-1027114

Résumé

Objective:To investigate the efficacy of double S-shaped elastic stable intramedullary nailing in the treatment of paediatric fractures of the distal tibia diaphyseal metaphyseal junction.Methods:From January 2018 to January 2022, a total of 25 children with fracture of the distal tibia diaphyseal metaphyseal junction were treated at Department of Pediatric Orthopedics, The Second Affiliated Hospital of Inner Mongolia Medical University. All of them were treated with closed reduction and double S-shaped elastic stable intramedullary nailing. There were 16 males and 9 females with an average age of (10.4±3.3) years, and 14 left sides and 11 right sides. The operation time, imaging results and complications were recorded after operation. At the last follow-up, the American Orthopaedic Foot & Ankle Society (AOFAS) scoring was used to evaluate the efficacy.Results:Closed reduction succeeded in all patients. The operation time was (55.6±23.7) min. Follow-up lasted (20.5±4.7) months for this cohort. Bony union was achieved in all patients after (11.5±2.7) weeks. No postoperative complications occurred in the patients, like infection, loss of reduction, disparity in length of lower limbs, delayed union or non-union. The AOFAS scoring at the last follow-up yielded 23 excellent and 2 good cases, and an excellent and good rate of 100% (25/25).Conclusion:In the treatment of paediatric fractures of the distal tibia diaphyseal metaphyseal junction, double S-shaped elastic stable intramedullary nailing is a safe, effective and feasible option.

19.
Article Dans Chinois | WPRIM | ID: wpr-1027116

Résumé

Objective:To evaluate the effect of the impaction of posterior wall on the prognosis following open reduction and internal fixation for fractures of acetabular posterior wall.Methods:A retrospective study was conducted to analyze the data from the 83 patients with fracture of acetabular posterior wall who had been consecutively treated by open reduction and internal fixation at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital from January 2017 to December 2020. The patients were divided into 2 groups based on involvement of posterior wall impaction. In the impaction group of 33 cases, there were 26 males and 7 females with an age of (47.4±11.6) years; in the non-impaction group of 50 cases, there were 43 males and 7 females with an age of (41.3±12.0) years. The quality of postoperative fracture reduction, the function of the affected hip at the last follow-up, and the complication rate during follow-up were compared between the 2 groups. Multifactorial binary logistic regression and age subgroups were used to analyze the effects of posterior wall impaction on functional outcomes.Results:The age, rate of associated injuries in other body parts, and rate of posterior wall comminution in the impaction group were significantly higher than those in the non-impaction group ( P<0.05), but there was no statistically significant difference in other general data of patients between the 2 groups ( P>0.05). All patients were followed up for (44.5±13.3) months after surgery. The rate of anatomical reduction in the non-impaction group (96.0%, 48/50) was significantly higher than that in the impaction group (57.6%, 19/33) ( P<0.05), and the good and excellent rate by the modified Merle d'Aubigné & Postel scale at the last follow-up in the non-impaction group (84.0%, 42/50) was significantly higher than that in the impaction group (51.5%, 17/33) ( P<0.05). There was no significant difference in the incidence of complications between the 2 groups ( P>0.05). After adjusting for age and gender, the difference in hip function was still significantly different between the 2 groups ( OR=0.23, 95% CI: 0.06 to 0.79, P=0.020). The effect of posterior wall impaction on functional outcomes was statistically significant in patients aged ≥50 years ( P=0.008), whereas the difference was not statistically significant in patients aged <50 years ( P=0.194). Conclusions:Compared with non-impaction ones, acetabular fractures of posterior wall impaction tend to lead to poorer quality of reduction, which in turn affects the postoperative recovery of hip joint function. The impact of impaction fractures on functional recovery is more significant in patients aged 50 years and above.

20.
Article Dans Chinois | WPRIM | ID: wpr-1027117

Résumé

Objective:To investigate the effectiveness of the modified Bikini approach in the fixation of acetabular fracture with an integrated wing-shaped anatomical locking plate.Methods:A retrospective study was conducted to analyze the data of 54 patients with acetabular fracture who had been treated at Department of Trauma Orthopedics, Orthopedic Medical Center, The Third Hospital Affiliated to Southern Medical University from May 2017 to June 2021. The patients were divided into 2 groups based on different surgical approaches: an observation group [26 cases, 6 males, 20 females; aged 40.0 (29.8, 46.8) years] treated with fixation with an integrated wing-shaped anatomical locking plate through the modified Bikini approach, and a control group [28 cases, 10 males, 18 females; aged 34.5 (24.0, 43.5) years] treated with fixation with an integrated wing-shaped anatomical locking plate through the lateral-rectus approach. The incision length, operation time, intraoperative bleeding, length of hospital stay, quality of postoperative fracture reduction, visual analog scale (VAS) for pain, hip function, Vancouver Scar Scale (VSS) and Patient and Observer Scar Assessment Scale (POSAS) were compared between the 2 groups.Results:The differences in the preoperative general data between the 2 groups were not statistically significant, indicating comparability ( P>0.05). There were no statistically significant differences between the 2 groups either in terms of incision length, operation time, intraoperative bleeding, or hospital stay ( P>0.05). The 2 groups were not significantly different in the excellent/good rate of fracture reduction [100.0% (26/26) versus 92.9% (26/28)], VAS at 1 month postoperation [2.0(1.0, 3.0) versus 2.0(1.0, 3.0)], or the modified Merle d'Aubigné and Postel hip score at 12 months postoperation [13.5(12.3, 14.8) versus. 14.0(13.0, 15.0)] ( P>0.05). However, the VSS [4.50(4.00, 6.00)] and POSAS (29.85±10.05) at 12 months postoperation in the observation group were significantly lower than those in the control group [6.50(5.00, 8.25) and 37.11±11.75] ( P<0.05). Conclusion:In the fixation of acetabular fracture with an integrated wing-shaped anatomical locking plate, the modified Bikini approach can not only achieve as fine early clinical efficacy as the lateral-rectus approach, but also demonstrate the aesthetic advantages of smaller incision scar and more hidden incision.

SÉLECTION CITATIONS