Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtre
1.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1520232

Résumé

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

2.
Arq. bras. oftalmol ; 84(2): 174-178, Mar,-Apr. 2021. graf
Article Dans Anglais | LILACS | ID: biblio-1153120

Résumé

ABSTRACT We report a case of a young Caucasian female presenting with sudden decrease of vision in the left eye, metamorphopsia, and nasal scotoma. Past medical history revealed a diagnosis of myasthenia gravis, which was currently treated with azathioprine, pyridostigmine, and prednisone. Ophthalmological examination showed fundus with clear vitreous and yellow-white lesions that were isolated and perimacular in the right eye, multiple and confluent in the macula, and punctate in periphery in the left eye. Laboratory workup ruled out the presence of infectious and inflammatory diseases. Fundus autofluorescence disclosed hypoautoflurescence with hyperfluorescent margins corresponding to the lesions observed in both eyes and the angiogram revealed hyperfluorescence since early phases without late leakage. Spectral-domain optical coherence tomography showed areas of intermittent retinal pigment epithelium elevations and disruption of the ellipsoid zone. She was diagnosed with punctate inner choroidopathy and then treated with an increased dose of daily prednisone, which resulted in progressive improvement of her visual acuity and anatomical status.(AU)


RESUMO Relato de caso de mulher jovem, caucasiana, com súbita diminuição de acuidade visual de olho esquerdo, metamorfopsia e escotoma nasal. Apresentava diagnóstico de Miastenia gravis, em tratamento com Azatioprina, Piridostigmina e Prednisona. Fundo de olho demonstrava vítreo límpido e lesões amarelo-esbranquiçadas, perimaculares e isoladas em olho direito, múltiplas e confluentes em mácula e pontilhadas em periferia no olho esquerdo. Exames laboratoriais descartaram doenças infecciosas e inflamatórias. Auto-fluorescência revelou lesões hipoautofluorescentes com margens hiperfluorescentes correspondentes às observadas em ambos os olhos, enquanto angiofluoresceinografia mostrou hiperfluorescência desde as fases iniciais sem vazamento tardio. Tomografia de coerência óptica de domínio espectral revelou áreas de elevações intermitentes do epitélio pigmentar da retina e interrupção da zona elipsóide correspondente. Definiu-se como diagnóstico a coroidopatia interna ponteada, sendo instituído aumento na dose diária de Prednisona, com melhoria progressiva da acuidade visual e do aspecto de fundo de olho da paciente.(AU)


Sujets)
Humains , Femelle , Adulte , Acuité visuelle , Choroïdite/physiopathologie , Angiographie fluorescéinique/instrumentation , Tomographie par cohérence optique/instrumentation , Imagerie multimodale/instrumentation , Imagerie optique/instrumentation
3.
Arq. bras. oftalmol ; 82(6): 522-527, Nov.-Dec. 2019. graf
Article Dans Anglais | LILACS | ID: biblio-1038687

Résumé

ABSTRACT A 26-year-old woman presented at 28 weeks gestation with hypertensive choroidopathy associated with pre-eclampsia. Fundus photography, fundus autofluorescence, spectral-domain optical coherence tomography (SD-OCT), fluorescein angiography, and indocyanine green angiography were performed in both eyes in the immediate postoperative period. SD-OCT images were obtained before delivery and during a 3-month follow-up. Fundus autofluorescence exhibited patchy hyper- and hypoautofluorescent lesions; fluorescein and indocyanine green angiography revealed areas of choroidal ischemia; and SD-OCT showed disorganization of the outer retinal layers and disruption of the ellipsoid zone. After her blood pressure was stabilized, progressive recovery of the outer retinal layer was monitored on SD-OCT.


RESUMO Uma mulher de 26 anos de idade, com 28 semanas de gestação apresentando coroidopatia hipertensiva associada à pré-eclâmpsia. Retinografia, autofluorescência, tomografia de coerência óptica de domínio espectral, angiofluoresceínografia e angiografia com indocianina verde foram realizadas em ambos os olhos no período pós-operatório imediato do parto. Imagens da tomografia de coerência óptica de domínio espectral foram obtidas antes do parto e durante o seguimento de 3 meses. A autofluorescência apresentou lesões heterogêneas hiper e hipoautofluorescentes, a angiofluoresceínografia e angiografia com indocianina verde revelaram áreas de isquemia de coroide, e a tomografia de coerência óptica de domínio espectral apresentou desorganização das camadas externas da retina e interrupção da zona elipsóide. Após a estabilização da pressão sanguínea, a recuperação progressiva da camada externa da retina foi monitorada pela tomografia de coerência óptica de domínio espectral.


Sujets)
Humains , Femelle , Grossesse , Adulte , Pré-éclampsie , Maladies de la choroïde/étiologie , Maladies de la choroïde/imagerie diagnostique , Hypertension artérielle/étiologie , Hypertension artérielle/imagerie diagnostique , Rémission spontanée , Angiographie fluorescéinique/méthodes , Tomographie par cohérence optique/méthodes , Épithélium pigmentaire de la rétine/anatomopathologie , Épithélium pigmentaire de la rétine/imagerie diagnostique
4.
Arq. bras. oftalmol ; 82(5): 412-416, Sept.-Oct. 2019. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1019424

Résumé

ABSTRACT Purpose: To evaluate the usefulness of fundus autofluorescence imaging of diabetic patients without retinopathy to investigate early retinal damage. Methods: Fundus autofluorescence images of patients with type 2 diabetes mellitus without retinopathy (diabetic group) and age-sex matched healthy patients (control group) were recorded with a CX-1 digital mydriatic retinal camera after detailed ophthalmologic examinations. MATLAB 2013a software was used to measure the average pixel intensity and average curve width of the macula and fovea. Results: Fifty-six eyes of 28 patients, as the diabetic group, and 54 eyes of 27 healthy patients, as the control group, were included in this study. The mean aggregation index was 168.32 ± 37.18 grayscale units (gsu) in the diabetic group and 152.27 ± 30.39 gsu in the control group (p=0.014). The mean average pixel intensity value of the fovea was 150.87 ± 35.83 gsu the in diabetic group and as 141.51 ± 31.10 gsu in the control group (p=0.060). The average curve width value was statistically higher in the diabetic group than in the control group (71.7 ± 9.2 vs. 59.4 ± 8.6 gsu, respectively, p=0.03). Conclusion: Fundus autofluorescence imaging analysis revealed that diabetic patients without retinopathy have significant fluorescence alterations. Therefore, a noninvasive imaging technique, such as fundus autofluorescence, may be valuable for evaluation of the retina of diabetic patients without retinopathy.


RESUMO Objetivo: Avaliar a utilidade da autofluorescência do fundo de olho de pacientes diabéticos sem retinopatia para investigar lesões precoces na retina. Métodos: Imagens de autofluorescência do fundo de olho de pacientes com diabetes mellitus do tipo 2 sem retinopatia (grupo diabético) e indivíduos saudáveis pareados por idade e sexo (grupo controle) foram registrados com uma câmera retiniana digital midriática CX-1 após exames oftalmológicos detalhados. O software MATLAB 2013a foi usado para medir a intensidade média do pixel e a largura média da curva da mácula e fóvea. Resultados: Cinquenta e seis olhos de 28 pacientes, como o grupo diabético, e 54 olhos de 27 indivíduos saudáveis, como grupo controle, foram incluídos neste estudo. O índice médio de agregação foi de 168,32 ± 37,18 unidades de escala de cinza (gsu) no grupo diabético e em 152,27 ± 30,39 gsu no grupo controle (p = 0,014). O valor médio da intensidade de pixel na fóvea foi de 150,87 ± 35,83 gsu no grupo diabético e de 141,51 ± 31,10 gsu no grupo controle (p=0,060). O valor médio da largura da curva foi estatisticamente maior no grupo diabético do que no grupo controle (71,7 ± 9,2 vs. 59,4 ± 8,6 gsu, respectivamente; p = 0,03). Conclusão: A análise por imagens de autofluorescência de fundo de olho revelou que pacientes diabéticos sem retinopatia apresentam alterações significativas de fluorescência. Portanto, uma técnica de imagem não invasiva, como a autofluorescência de fundo de olho, pode ser valiosa para a avaliação da retina de pacientes diabéticos sem retinopatia.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Sujet âgé , Rétinopathies/imagerie diagnostique , Diabète de type 2/physiopathologie , Rétinopathie diabétique/diagnostic , Imagerie optique/méthodes , Fond de l'oeil , Rétinopathies/physiopathologie , Angiographie fluorescéinique/méthodes , Acuité visuelle , Études cas-témoins
5.
Arq. bras. oftalmol ; 80(3): 192-195, May-June 2017. graf
Article Dans Anglais | LILACS | ID: biblio-888106

Résumé

ABSTRACT We present a case of a patient with resolved central serous chorioretinopathy (CSC) in the left eye with persistent mild visual alterations 4 years after the resolution of the disease. Left eye exam revealed a best corrected visual acuity of 20/25 and a slight change of macular pigmentation. Optical coherence tomography revealed only minor irregularities in the topography of retinal pigment epithelium and Bruch's membrane. Adaptive optics (AO) optics demonstrated lower density, spacing, and changes in the photoreceptor mosaic pattern in the left eye than in the right eye, suggesting that CSC may cause damage to cones after clinical recovery. We conclude that AO can provide additional information to assist in the treatment and follow-up of patients with CSC or other macular pathologies.


RESUMO Apresentamos o relato de caso de paciente com coriorretinopatia serosa central (CSC) cicatrizada em olho esquerdo e queixa de discreta alteração visual, mesmo após quatro anos da resolução do quadro. O exame do olho esquerdo apresenta melhor acuidade visual corrigida de 20/25 e discreta alteração de pigmentação macular. Tomografia de coerência óptica (OCT) apresentou apenas pequenas irregularidades em topografia de EPR e Bruch. Foi realizado exame com Adaptive Optics (AO), evidenciando valores inferiores de densidade, espaçamento e alterações no padrão de mosaico dos fotorreceptores em olho esquerdo quando comparado com olho direito, sugerindo que a CSC pode causar danos em cones, mesmo após uma recuperação considerada satisfatória. Concluímos que o AO é uma tecnologia que traz novas informações para auxiliar o tratamento e seguimento dos pacientes com CSC ou outras patologias maculares.


Sujets)
Humains , Femelle , Adulte d'âge moyen , Décollement de la rétine/physiopathologie , Décollement de la rétine/imagerie diagnostique , Techniques de diagnostic ophtalmologique/instrumentation , Segment externe de cellule photoréceptrice rétinienne/physiologie , Choriorétinopathie séreuse centrale/physiopathologie , Choriorétinopathie séreuse centrale/imagerie diagnostique , Rétine/physiopathologie , Rétine/anatomopathologie , Rétine/imagerie diagnostique , Décollement de la rétine/anatomopathologie , Décollement de la rétine/thérapie , Acuité visuelle , Tomographie par cohérence optique/méthodes , Segment externe de cellule photoréceptrice rétinienne/anatomopathologie , Choriorétinopathie séreuse centrale/anatomopathologie , Choriorétinopathie séreuse centrale/thérapie
SÉLECTION CITATIONS
Détails de la recherche