1.
Chinese Journal of Interventional Imaging and Therapy ; (12): 100-104, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1024456

Résumé

Objective To observe the value of a YOLOX target detection model for automatically identifying endovascular interventional instruments on images of digital subtract angiography(DSA).Methods DSA data of 37 patients who underwent abdominal endovascular interventional therapy were retrospectively analyzed.Totally 4 435 DSA images were captured and taken as data set,which were divided into training set(n=3 991)and verification set(n=444)at the ratio of 9∶1.Six kinds of endovascular interventional instruments were labeled.YOLOX algorithm was applied for deep learning of data in training set in order to build a target detection model,and the efficacy of the model for automatically identifying endovascular interventional instruments on DSA images was evaluated based on varification set.Results A total of 6 668 labels were put on 4 435 DSA images,aimed on Terumo 0.035in loach guide wire(n=587),Cook Lunderquist super hard guide wire(n=990),Optimed 5F with graduated pig tail catheter(n=1 680),Cordis MPA multi-functional catheter(n=667),Boston Scientific V-18 controllable guide wire(n=1 330)and Terumo 6F long sheath(n= 1 414),respectively.The training set contained 527,875,1 466,598,1 185 and 1 282,while the verification set contained 60,115,214,69,145 and 132 the above labels,respectively.The pixel accuracy of YOLOX target detection model for automatically identifying the above instruments in the verification set was 95.23%,97.32%,99.18%,98.97%,97.60%and 98.19%,respectively,with a mean pixel accuracy of 97.75%.Conclusion YOLOX target detection model could automatically identify endovascular interventional instruments on images of DSA.

2.
China Medical Equipment ; (12): 129-132, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1026539

Résumé

Objective:To compare the testing effects of different testing methods in the functional inspection of precision surgical scissors and needle holders.Methods:By consulting relevant literature and professional books,three testing methods and materials for precision surgical scissors and needle holders were selected.The cutting performance of the precision surgical scissors were tested by gauze cloth,cotton wool,and silicone film method in the Interlock surgical instrument testing set.The clamping performance of precision needle holder was tested by using light,needle clips,and thread clamping method in the Interlock surgical instrument testing set.100 pieces of precision surgical scissors and needle holders which were qualified for cleaning and disinfection in the hospital were selected for effectiveness testing,and a self-made satisfaction questionnaire to investigate the satisfaction of surgeons with the use of instruments.Results:After 100 precision surgical scissors tested using three methods of gauze,cotton wool,and silicone film,the qualified number of cutting performance was 94,76,and 58,respectively,the difference was statistically significant(x2=36.526,P<0.05).The satisfaction rate of surgeons with the use of precision surgical scissors passed the silicone film test was the highest at 100%,followed by cotton wool cloth at 82.0%,and the gauze method at the worst at 67.0%,the difference was statistically significant(x2=48.439,P<0.05).After 100 precision needle holders were tested by using three methods of light irradiation,needle clamping,and wire clamping,the qualified number of clamping performance was 96,78,and 62,respectively,the difference was statistically significant(x2=38.160,P<0.05).The satisfaction rate of surgeons with the precision needle holders passed the clamp line test was the highest at 100.0%,followed by the clamp needle at 79.0%,and the worst under light at 62.0%,the difference was statistically significant(x2=57.705,P<0.05).Conclusion:The function and quality of precision surgical scissors and needle holders tested by the test objects in Interlock Surgical Instrument Test Suite can objectively and accurately reflect the functional status of surgical scissors and needle holders,provide reference for regular maintenance and upkeep of instruments,and ensure safe use of instruments.

3.
Chinese Hospital Management ; (12): 21-26, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1026626

Résumé

Objective Based on the Hood Policy Tool perspective on China's DIP policy text mining,word frequen-cy analysis and clustering analysis of the policy content,to explore the actual policy in each pilot region,to further analyze the reasons,to provide a scientific and reference for the subsequent policy adjustment and implementation.Methods Policies were included in this study from platforms such as local healthcare protection bureaus,local health-care commissions,local people's government portals,and NVivo,from which policy documents with a high degree of relevance to DIP were selected.NVivo 20.0 software was used for text coding,word frequency analysis,and analysis based on Hood's policy tool dimensions and regional distribution dimensions to further explore DIP policy specifics.Results A total of 27 policies were included,covering all pilot provinces,with a total of 1,707 policy codes.Authoritative,fiscal,informational,and organizational policy instruments accounted for 54.9%,20.3%,16.9%,and 7.9%,respectively.The percentage of coded reference points in the East,Central,West,and Northeast regions were 23.0%,20.2%,44.5%,and 8.7%,respectively.Conclusion The use of DIP policy tools in the pilot regions focused on authoritative tools and less on organization tools.Among the authoritative policy tools,the sub-tools of mechanism building were mostly used,while the sub-tools of standards and norms were less used.The focus of the policy tools varies among the pilot regions,and the use of policy tools should be tailored to the local context.

4.
Journal of Modern Urology ; (12): 179-182, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1031676

Résumé

【Objective】 To explore the feasibility of en-bloc resection of bladder tumors by flexible cystoscope combined with laparoscopic instruments through urethra and to provide reference for the clinical application of this technique. 【Methods】 Self-designed and processed transurethral single-hole PORT and Olympus electronic cystoscope were used as observation mirror; Φ1.8 mm soft grasper, tissue scissors, electric hook, and ultrasonic scalpel were used as instruments; the porcine bladder was used as a model.The PORT was placed through the urethra, and the cystoscope was inserted to observe the inner wall of the bladder and the condition of the mucosa.After the lesion site was identified in the bladder cavity, the soft grasper was inserted to pull the mucosa to be removed, which was then fixed with tension at the target position to maintain a satisfactory feild of view.The surgeon held the cystoscope in the left hand, and operated the laparoscopic instruments into the bladder cavity through the PORT with the right hand.Observing with the cystoscope and lifting and pulling the mucosa with the grasper, the surgeon simulated the cutting and pushing actions to realize the en-bloc resection of the lesioned mucosa. 【Results】 The mucosa at 4 different locations were successfully resected on 2 in vitro porcine bladder models. 【Conclusion】 The in vitro experiments show that the combination of flexible electronic cystoscope and laparoscopic instruments achieves synergistic effects in en-bloc resection of bladder tumor by transurethral single-hole laparoscope without additional iatrogenic bladder injury caused by percutaneous bladder incision.This method is feasible in the treatment of bladder tumors, and has the potential of clinical application after further optimization.

5.
International Journal of Traditional Chinese Medicine ; (6): 439-443, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1018325

Résumé

Objective:This study was designed to explore the distribution pattern of TCM syndrome types in patients with Chronic Kidney Disease (CKD) stage 3-5 without alternative treatment after objective collection of TCM quad-diagnostic instruments.Methods:The four-diagnostic instruments of Chinese medicine were used to collect the four-diagnostic information of patients with stage CKD 3-5 non-alternative treatment for syndrome determination, and the correlation between TCM syndrome and basic disease characteristics of patients was analyzed.Results:The distribution of TCM syndrome types in 464 patients with CKD 3-5 stage non-substitution therapy was based on deficiency syndrome, and had both standard and solid syndrome. Qi-deficiency syndrome was the most common type, accounting for 24.6% (114/464), followed by kidney-yang deficiency syndrome, heart-qi deficiency syndrome, kidney-yin deficiency syndrome, heart-blood deficiency syndrome, spleen-yang deficiency syndrome and lung-yin deficiency syndrome. The positivism type of this deficiency is blood stasis, dampness-heat, moisture, turbidity and turbidity toxicity. There was no significant difference in gender and age distribution among patients with different CKD stages ( P>0.05), but the proportion of deficiency syndrome gradually increased with the increase of age. There were differences in the distribution of primary deficiency syndrome in different CKD stages ( χ2=57.48, P<0.001), but no difference in the distribution of primary deficiency syndrome ( χ2=2.59, P=0.957). Conclusions:According to the four diagnostic instrument of traditional Chinese medicine, the distribution of TCM syndrome types in patients with stage CKD3-5 non-alternative treatment is based on deficiency syndrome, combined with deficiency of primary and solid syndrome. The syndrome types in CKD3 stage were mainly qi deficiency and kidney qi deficiency, while the TCM syndrome types in CKD stage 4 were qi deficiency and kidney Yang deficiency. With the progression of the disease, the TCM syndromes of stage 5 CKD were mainly heart-qi deficiency and kidney-yang deficiency.

6.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 101-107, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1006354

Résumé

Objective@#The purpose of this study was to investigate the differences in the anti cyclic fatigue performance of Woride KS (WKS), Proteper Gold (PTG), and Hyflex CM (HCM) nickel titanium instruments with different tip diameters in curved root canal models, and to provide reference for the targeted selection of suitable nickel titanium instruments in clinical preparation of curved root canals.

7.
São Paulo med. j ; 142(2): e2023325, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1551073

Résumé

ABSTRACT BACKGROUND: The Positive Aspects of Caregiving (PAC) scale is used to assess psychosocial benefits provided to caregivers by the task of caring. The PAC scale consists of nine items, assessed using a five-point Likert scale, with higher values indicating greater positive perceptions and gains from the caregiving experience. OBJECTIVE: To translate and culturally adapt the PAC scale for informal Brazilian caregivers of people with dementia. DESIGN AND SETTING: A methodological study was conducted at the Federal University of São Carlos. METHODS: The following stages were carried out: Translation; Synthesis of the translations; Back-translation; Evaluation by an experts' committee; and Pre-test. RESULTS: Two independent professionals translated the PAC scale. The consensus version was obtained by merging both translations, which were back-translated into English by a third translator. The expert committee comprised three specialists in the area and project researchers. All scale items presented a Content Validity Index of 1 (CVI = 1.0), and thus remained in the pre-final version of the instrument. The instrument was pre-tested with seven caregivers of people with dementia, the majority of whom were women (57.1%), with a degree of kinship corresponding to sons/daughters (57.1%) and an average age of 55.2 (± 4.1) years. The caregivers considered it clear and understandable and made no suggestions for changes. CONCLUSION: The PAC scale was translated and culturally adapted for use by informal caregivers of people with dementia in Brazil. However, a psychometric analysis of the instrument is necessary to provide normative data for this population group.

8.
Trends psychiatry psychother. (Impr.) ; 46: e20220492, 2024. tab
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1536920

Résumé

Abstract Objective Grazing is a disturbed eating pattern that has been associated with eating disorders and obesity. One of the new measures to investigate this eating behavior is the Short Inventory of Grazing (SIG), a two-item questionnaire that assesses grazing in general and grazing associated with the feeling of loss of control over eating (LOC grazing). However, the psychometric properties of the SIG have not been assessed in the Brazilian population. The present study aimed to cross-culturally adapt and validate a Brazilian version of the SIG. Methods The SIG was adapted to the Brazilian context following international guidelines. Then, 90 undergraduate students completed an online survey including questions from the SIG, the Binge Eating Scale (BES), the Patient Health Questionnaire-9 (PHQ9), the Generalized Anxiety Disorder-7 (GAD7), and a question related to self-reported health status. The internal consistency, test-retest reliability, and convergent validity of the questionnaire were assessed. Results The prevalence rates of at least one weekly episode of grazing in general and LOC grazing were 71.1 and 54.5%, respectively. The internal consistence of the SIG was acceptable (0.81). In addition, SIG scores on both items were positively and significantly associated with BES, GAD7, and PHQ9 scores, and with poorer self-rated health. However, SIG test and retest scores differed significantly. Conclusion Overall, the Brazilian version of the SIG demonstrated adequate psychometric properties. The instrument had adequate internal consistency, with both items exhibiting good convergent validity with related measures.

9.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1564080

Résumé

Abstract Cleaning and shaping the root canal system are essential steps for performing successful endodontic therapy, and are challenging procedures in the apical region. This study aimed to conduct an ex vivo assessment of the debridement ability of the WaveOne Gold (Medium 35/.06) and TruNatomy (Medium 36/.03) systems in the apical third of round root canals of mandibular premolars. Forty-eight teeth, extracted for orthodontic or periodontal reasons, were divided into three groups (n=16), as follows: Group C, control (without instrumentation or irrigation); Group WOG, instrumentation with WaveOne Gold; Group TN, instrumentation with TruNatomy. A total of 40 mL of 2.5% sodium hypochlorite and 5 mL of 17% ethylenediamine tetraacetic acid were used per root canal in all the groups. Ten 0.5-μm serial cross-sections per specimen were obtained every 0.2 mm from a 2-mm segment of the apical region, extending from 1 to 3 mm short of the root apex. The sections were stained with hematoxylin-eosin and analyzed under a digital microscope (100x). The percentages of unprepared walls and remaining debris were quantified using ImageJ software. Generalized linear models were used to analyze the results (α=5%). Groups WOG and TN had significantly lower percentages of unprepared walls and remaining debris than Group C (p<0.05). There was no significant difference between groups WOG and TN for either of the variables studied (p>0.05). Instrumentation with the WaveOne Gold Medium and TruNatomy Medium instruments was associated with equivalent percentages of unprepared walls and remaining debris in the apical third of round canals of mandibular premolars.


Resumo A limpeza e modelagem do sistema de canais radiculares são etapas fundamentais para o sucesso da terapia endodôntica e são procedimentos desafiadores na região apical. O objetivo deste trabalho foi realizar uma avaliação ex vivo da capacidade de debridamento dos sistemas WaveOne Gold (Medium 35/.06) e TruNatomy (Medium 36/.03) no terço apical de canais radiculares circulares de pré-molares inferiores. Quarenta e oito dentes que haviam sido extraídos por razões ortodônticas ou periodontais foram divididos em três grupos (n=16),da seguinte forma: Grupo C, Controle (sem instrumentação nem irrigação); Grupo WOG, instrumentação com WaveOne Gold; Grupo TN, instrumentação com TruNatomy. Um total de 40 mL de hipoclorito de sódio a 2,5% e 5 mL de ácido etilenodiamino tetraacético a 17% foi utilizado por canal radicular em todos os grupos. Dez secções transversais em série de 0,5 μm por espécime foram obtidas a cada 0,2 mm de um segmento de 2 mm da região apical, estendendo-se desde 1 até 3 mm aquém do ápice radicular. As seções foram coradas com hematoxilina-eosina e analisadas sob um microscópio digital (100x). As porcentagens de paredes não tocadas e detritos remanescentes foram quantificadas utilizando-se o software ImageJ. Modelos lineares generalizados foram utilizados para analisar os resultados (α=5%). Os grupos WOG e TN apresentaram porcentagens significativamente menores de paredes intocadas e detritos remanescentes do que o grupo C (p<0,05). Não houve diferença significativa entre os grupos WOG e TN quanto a nenhuma das variáveis estudadas (p>0,05). A instrumentação com os instrumentos WaveOne Gold Medium e TruNatomy Medium foi associada a porcentagens equivalentes de paredes intocadas e detritos remanescentes no terço apical de canais circulares de pré-molares inferiores.

10.
Braz. oral res. (Online) ; 38: e006, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1528151

Résumé

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

11.
Interaçao psicol ; 27(3): 330-340, ago.-dez. 2023.
Article Dans Portugais | LILACS-Express | LILACS | ID: biblio-1531341

Résumé

A autoestima é um termo muito utilizado pelas pessoas no senso comum, mas ainda são necessários mais estudos para entendê-lo sob o ponto de vista comportamental. O objetivo deste estudo foi realizar uma revisão de textos da Análise do Comportamento a respeito de autoestima. Foi realizada uma busca em três fontes diferentes: periódicos exclusivos de Análise do Comportamento; as coleções de livros Sobre Comportamento e Cognição e Comportamento em Foco; e na Scielo. No total, 16 textos preencheram os critérios, que eram a) ter a palavra "autoestima" no título b) ser um texto da Análise do Comportamento. Foram discutidas as definições de autoestima utilizadas, os participantes dos estudos, os estímulos usados em testes de medida implícita e os principais resultados. Nenhum dos textos analisados utilizou intervenções voltadas ao aumento da autoestima. Apesar de serem textos da abordagem comportamental, muitos dos estudos utilizam apenas definições e instrumentos não comportamentais. As principais conclusões da revisão foram: 1) ainda existem poucos estudos sobre autoestima na Análise do Comportamento; 2) ainda não existe uma definição comportamental bem construída, especialmente na literatura internacional.


Self-esteem is a term that is widely used in common sense, but more studies are still needed to understand it from a behavioral point of view. The objective of this study was to carry out a review of Behavior Analysis papers regarding self-esteem. A search was conducted in three different sources: Behavior Analysis journals; the book collections Sobre Comportamento e Cognição and Comportamento em Foco; and on Scielo. In total, 16 texts met the criteria, which were a) having the word "self-esteem" in the title and b) being a Behavior Analysis text. We discuss the definitions of self-esteem used, the participants in the studies, the stimuli used in the implicit measurement tests and the main results. None of the analyzed texts used interventions aimed to increase self-esteem. Even though they are texts of the behavioral approach, many of the studies only use non-behavioral definitions and instruments. The main conclusions of the review were: 1) there are still few studies on self-esteem in Behavior Analysis; 2) there is still no well-constructed behavioral definition, especially in international literature.

12.
J. res. dent ; 11(2): 25-31, Oct 2023.
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1513036

Résumé

Aims: The aim was to evaluate the cyclic and torsional fatigue resistance among thermally treated NiTi rotary instruments with different design features.Materials and methods: Sixty instruments of three systems were used (n=20): TruNatomy 26.04 (TN 26.04), BassiLogic 25.05 (BL 25.05), and Flat File 25.04 (FF 25.04). The cyclic fatigue test (n=10) was performed to evaluate the time to fracture (s) and the number of cycles until failure (NCF). The torsion test was performed to evaluate the torque (N.cm) and maximum angular deflection until fracture (n=10). The fracture surface of each fragment was examined under a scanning electron microscope. The data were analyzed by Tukey's test (p<0.05).Results: BL 25.05 and FF 25.04 instruments had a higher number of cycles and time to fracture compared with TN 26.04 (p<0.05). TN 26.04 instruments showed lower torque to fracture.Conclusions: Based on the proposed objectives and the methodology used, TruNatomy 26.04 instruments present lower resistance to cyclic fatigue and torsional fatigue when compared to BassiLogic 25.05 and Flat File 25.04 instruments.

14.
RFO UPF ; 28(1)20230808. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1511056

Résumé

Introdução: Mesmo com toda evolução tecnológica desses instrumentos, com o desenvolvimento das limas de liga de níquel-titanio (NiTi) e sistemas mecanizados, as fraturas podem ocorrer durante o preparo químico/mecânico. Existem três abordagens mais regulamente aplicadas para solucionar essa intercorrencia: tentativa de remoção do instrumento com ultrassom, tentativa de ultrapassálo (bypass) ou a obturação do segmento. Objetivo: Relatar um caso da técnica de bypass em instrumento fraturado no canal radicular. Descrição do caso: Paciente, sexo feminino, 47 anos, brasileira, sem condições sistêmicas associadas, foi encaminhada à clínica do Curso de Odontologia da UNIFENAS, Divinópolis, Minas Gerais, Brasil, para resolução de fratura de instrumento no canal mésio- vestibular do primeiro molar superior direito (16). Optou-se pelo tratamento pela técnica de bypass, que envolveu as seguintes etapas: anestesia, abertura, utilização de lima C-Pilot #08 para ultrapassar o instrumento fraturado, odontometria, escalonamento regressivo a partir da lima k#20, desinfecção com hipoclorito de sódio 5%, medicação com hidróxido de cálcio por 21 dias, agitação da substância irrigadora e obturação dos canais radiculares. Conclusão: O bypass ao instrumento é uma técnica conservadora, eficaz e uma solução adequada em casos de fratura de limas endodônticas dentro dos canais radiculares. Essa técnica visa preservar o máximo possível da estrutura dental original, evitando procedimentos mais invasivos.(AU)


Introduction: Even with all technological evolution of these instruments, with the development of nickel-titanium alloy (NiTi) files and mechanized systems, fractures can occur during chemical/mechanical preparation. There are three most commonly applie to resolve this complication: attempting to remove the instrument with ultrasound, attempting to bypass it, or obturating the segment. Objective: To report a case of bypass technique in fractured instrument in the root canal. Case description: A 47-year-old female patient from Brazil, with no associated systemic conditions, was referred to the clinic of the Dentistry Course at UNIFENAS, Divinópolis, Minas Gerais, Brazil, for resolution of an instrument fracture in the mesio-vestibular canal of the right upper first molar (16). Treatment was performed using the bypass technique, which involved the following steps: anesthesia, opening, use of a C-Pilot #08 file to bypass the fractured instrument, odontometry, regressive scaling from the k#20 file, disinfection with 5% sodium hypochlorite, medication with calcium hydroxide for 21 days, agitation of the irrigating substance and root canal filling. Conclusion: Instrument bypass is a conservative, effective technique and an adequate solution in cases of endodontic file fracture within root canals. This technique aims to preserve as much of the original tooth structure as possible, avoiding more invasive procedures.(AU)


Sujets)
Humains , Femelle , Adulte d'âge moyen , Traitement de canal radiculaire/instrumentation , Instruments dentaires , Cavité pulpaire de la dent/imagerie diagnostique , Panne d'appareillage , Titane , Radiographie dentaire , Résultat thérapeutique , Nickel
15.
Rev. mex. trastor. aliment ; 13(1): 58-70, ene.-jun. 2023. tab, graf
Article Dans Espagnol | LILACS-Express | LILACS | ID: biblio-1530218

Résumé

Resumen Con la finalidad de evaluar la presencia de insatisfacción corporal en jóvenes varones, resulta importante contar con instrumentos adecuados que midan esta insatisfacción y que garanticen resultados válidos. En el Perú y en diversos países, no se cuenta con gran variedad de herramientas apropiadas que midan la insatisfacción de la imagen corporal en varones, por lo que el propósito de la investigación fue adaptar lingüística y psicométricamente el BSQ en un grupo de jóvenes varones universitarios (n=320) de Lima Metropolitana con un rango de edad de 18 a 30 años. Se obtuvo una explicación del 50.72% sobre la variabilidad del instrumento y los resultados mostraron una excelente consistencia interna en ambos factores: 1) Malestar Corporal Normativo (α= .88) y 2) Malestar Corporal Patológico (α= .87). Respecto a la validez convergente y divergente, el BSQ demostró una buena capacidad para determinar la presencia de insatisfacción de la imagen corporal denotando una convergencia positiva y significativa entre ambos factores del BSQ con el Afecto Negativo del SPANAS, explicando como todos estos sentimientos negativos se encuentran presentes e influyen con la aparición de esta incomodidad. Se discuten las limitaciones y recomendaciones del estudio, y la dirección de futuras investigaciones.


Abstract In order to evaluate the presence of corporal dissatisfaction in young men, it is important to have adequate instruments to measure this dissatisfaction and guarantee valid results. However, in Peru and several countries, there is not a great variety of appropriate tools to assess body image dissatisfaction. The present research aimed to adapt the Body Shape Questionnaire (BSQ) to a group of young male university students (N = 320) from Metropolitan Lima with an age range of 18 to 30 years. Results showed a 2-factor structure that explained 50.72% of the total variance. An excellent internal consistency was obtained in both factors: 1) Normative Body Uncomfort (α = .88) and 2) Pathological Body Uncomfort (α = .87). Regarding convergent and divergent validity, the BSQ showed good ability to determine the presence of body image dissatisfaction, denoting a positive and significant convergence between both BSQ factors with the PANAS Negative Affect, explaining how all these negative feelings are present and influence with this discomfort. Finally, the limitations and recommendations of the study, as well as the direction of future research are discussed.

16.
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1535289

Résumé

Introduction: the in vitro study compared the dynamic cyclic fatigue resistance of 3 reciprocating NiTi files with heat treatment. Methods: we distributed 30 new endodontic files in three groups. The endodontic files selected for this experiment were: AF Blue R3 25/06 (AFB) (Fanta Dental, Shanghai, China), X1 Blue File 25/06 (X1B) (MK Life, Porto Alegre, RS, Brazil), and Reciproc Blue 08/25 (RB) (VDW, Munich, Germany. We measured the time to file fractureand the length of the fractured fragment. ANOVA analysis was used, followed by the Tukey test for multiple comparisons, with a significance level of 5% (P < 0,05). Results: the mean time in seconds until the file fractured was 170.7 ±15,1 for AFB files, 110,4 ±26,8 for X1B, and 163,3 ±22,9 for RB files. This difference was statistically significant when comparing X1B to AFB (p: 0,000) and X1B to RB (p: 0,000). However, there are no statistically significant differences between RB and AFB (p:0,739). Conclussions: this study found that RB and AFB files exhibit similar resistance to cyclic fatigue.


Introducción: el estudio in vitro comparó la resistencia a la fatiga cíclica dinámica de 3 limas NiTi recíprocas con tratamiento térmico. Métodos: distribuimos 30 limas endodónticas nuevas en tres grupos. Las limas endodónticas seleccionadas para este experimento fueron: AF Blue R3 25/06 (AFB) (Fanta Dental, Shanghai, China), X1 Blue File 25/06 (X1B) (MK Life, Porto Alegre, RS, Brasil), y Reciproc Blue 08/25 (RB) (VDW, Munich, Alemania. Se midió el tiempo transcurrido hasta la fractura de la lima y la longitud del fragmento fracturado. Se utilizó el análisis ANOVA, seguido de la prueba de Tukey para comparaciones múltiples, con un nivel de significación del 5% (P < 0.05). Resultados: el tiempo medio en segundos hasta la fractura de la lima fue de 170.7 ±15.1 para las limas AFB, 110.4 ±26.8 para las X1B y 163.3 ±22.9 para las RB. Esta diferencia fue estadísticamente significativa al comparar X1B con AFB (p: 0.000) y X1B con RB (p: 0.000). Sin embargo, no hay diferencias estadísticamente significativas entre RB y AFB (p:0.739). Conclusiones: en este estudio se ha comprobado que las limas RB y AFB presentan una resistencia similar a la fatiga cíclica.

17.
J. res. dent ; 11(1): 7-13, May 2023.
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1513029

Résumé

NiTi endodontic instruments for glide path are the most susceptible to fractures inside the root canal, mainly as a result of high torsional stress. Objective: The present study investigated the resistance to torsion and angular deflection of instruments destined for the glide path: ProGlider #16.02; T-File #17.02 and the MK Life #16.02. Materials and methods: Thirty rotating NiTi glide path instruments (n=10) with 25mm lengths were selected. The torsion test was performed based on ISO 3630-01 (1992). Three millimeters from the tip of the instruments, it was attached to a small load cell by a lever arm connected to the torsion shaft. Torsional strength and angular deflection were evaluated. Fracture surfaces were examined by scanning electron microscopy with magnifications of 1000x and 5000x in the cross section, and 50x in the lateral section. Statistical analysis was performed using the Kruskal-Wallis H test, followed by the Down's post hoc test. Results: The ProGlider instrument showed greater torsional strength (p<0.05) compared to the T-File (p<0.05) and MK Life (p<0.05), respectively. However, the T-File showed greater angular deflection (p<0.05) than the other groups tested. Conclusion: It can be concluded that the ProGlider instrument presented greater torque for the fracture, while the T-File instrument presented greater angular deflection.

18.
Rev. ADM ; 80(1): 6-10, ene.-feb. 2023. ilus, tab
Article Dans Espagnol | LILACS | ID: biblio-1510346

Résumé

Introducción: el material para empaquetar el instrumental odontológico, como pueden ser bolsas de tela, papel o plástico, es usado por profesionales de la salud; sin embargo, es necesario esclarecer la efectividad de cada uno y determinar el tiempo que permanece estéril luego del procedimiento. Objetivo: identificar la eficacia de tela, plástico y papel como materiales para esterilizar instrumental a corto y largo plazo. Material y métodos: se realizaron cultivos sólidos y líquidos de instrumental esterilizado en tres materiales y con diferentes tiempos de postesterilización. Se incubaron a 36 oC por 72 horas en condiciones aerobias y anaerobias. Los resultados se analizaron usando una prueba de Kruskal-Wallis, seguida de una prueba de Dunn. Resultados: los resultados mostraron que inmediatamente después del proceso de esterilización, los tres materiales son efectivos (Kruskal-Wallis test, p = 0.2752), 24 horas (p = 0.2492), siete (p = 0.0509) y 14 días (p = 0.0006). Veinticuatro horas posterior a la esterilización la tela no es efectiva, el plástico disminuye su efectividad y el papel sigue siendo efectivo. Conclusión: en nuestros resultados, el papel es la mejor opción para esterilizar instrumental (AU)


Introduction: material such as cloth, paper or plastic bags to wrap dental instruments is used by health professionals, however, it is necessary to clarify the effectiveness of each one and determine if it remains sterile after the procedure. Objective: to determine the effectiveness of cloth, plastic and paper as materials to sterilize dental instruments in the short and long term. Material and methods: we carry out solid and liquid cultures of sterilized instruments in three materials, at different post-sterilization times, incubated at 36 oC for 72 hours under aerobic and anaerobic conditions, and the results were analyzed using a Kruskal-Wallis test, followed by from a Dunn's test. Results: our results showed that immediately after the sterilization process the three materials are effective (Kruskal-Wallis; p = 0.2752), 24 hours (p = 0.2492), 7 (p = 0.0509) and 14 (p = 0.0006) days. Twenty-four hours after the cloth is not effective, plastic decreases its effectiveness and paper remain effective. Conclusion: in our results, paper is the best option to sterilize dental instruments (AU)


Sujets)
Stérilisation/méthodes , Instruments dentaires/microbiologie , Papier , Matières plastiques , Textiles , Temps , Efficacité (Effectiveness) , Numération de colonies microbiennes/méthodes , Statistique non paramétrique , Emballage de produit/instrumentation , Milieux de culture
19.
Chinese Journal of Medical Instrumentation ; (6): 252-257, 2023.
Article Dans Chinois | WPRIM | ID: wpr-982223

Résumé

Based on the joint analysis of EMG spectrum and amplitude method (JASA), a study on muscle fatigue assessment of spinal surgical instruments based on surface EMG signals was carried out, and a comparative evaluation of the operating comfort before and after the optimization of spinal surgical instruments was completed. A total of 17 subjects were recruited to collect the surface EMG signals of their brachioradialis and biceps. Five surgical instruments before and after optimization were selected for data comparison, and the operating fatigue time proportion of each group of instruments under the same task was calculated based on the RMS and MF eigenvalues. The results showed that when completing the same operation task, the operation fatigue time of the surgical instruments before optimization was significantly higher than that after optimization (P<0.05); there was no significant difference in the fatigue status of brachioradialis and biceps when operating the same instrument (P>0.05). These results provide objective data and reference for the ergonomic design of surgical instruments and fatigue damage protection.


Sujets)
Humains , Fatigue musculaire/physiologie , Muscles squelettiques , Électromyographie , Ingénierie humaine
20.
Article Dans Portugais | LILACS, BDENF | ID: biblio-1443967

Résumé

Objetivo: Conhecer as estratégias utilizadas por instrumentadores para o controle de materiais e instrumental cirúrgico no intraope-ratório. Método: Estudo descritivo e qualitativo, realizado em hospital privado. Participaram 13 instrumentadores cirúrgicos. Os dados foram coletados entre agosto e setembro de 2022 por meio de entrevistas gravadas em áudio. Como instrumento para coleta dos dados, utilizou-se um roteiro estruturado, contendo sete perguntas, e questões referentes ao perfil da amostra. Foram incluídos técnicos de enfermagem forma-dos, atuantes como instrumentadores cirúrgicos. Foram excluídos instrumentadores ausentes no período da coleta de dados. Os dados foram analisados por meio da análise de conteúdo. Resultados: Com base na análise dos dados, emergiram quatro categorias: protocolo de cirurgia segura; controle de materiais e instrumentais; desafios no seguimento do protocolo de cirurgia segura; facilitadores do seguimento do proto-colo de cirurgia segura. Conclusão: Pôde-se conhecer as estratégias utilizadas por instrumentadores cirúrgicos para o controle dos materiais dispostos na mesa de instrumentação durante o intraoperatório. Pressa de profissionais, falta de adesão e o não seguimento de rotinas insti-tucionais caracterizam-se como desafios para o seguimento das etapas do protocolo de cirurgia segura


Objective: To know the strategies used by surgical technologists to control materials and surgical instruments in the intraopera-tive period. Method: This qualitative descriptive study was carried out in a private hospital. A total of 13 surgical technologists participated in the research. Data were collected during audio-recorded interviews between August and September 2022. The data collection instrument was a structured questionnaire consisting of seven questions, as well as items related to the sample profile. We included trained nursing technicians, working as surgical technologists. Those who were absent during data collection were excluded. Data were analyzed by con-tent analysis. Results: The data analysis produced four categories: surgical safety checklist; control of materials and instruments; challenges in following the surgical safety checklist; facilitators to following the surgical safety checklist. Conclusions: The study allowed us to know the strategies used by surgical technologists to control the materials arranged on the instrument table during the intraoperative period. The haste of professionals, lack of adherence, and non-compliance with institutional routines are regarded as challenges in following the steps of the surgical safety checklis


Objetivo: Conocer las estrategias utilizadas por instrumentistas para el control de materiales e instrumental quirúrgico en el intraope-ratorio. Método: Estudio descriptivo y cualitativo, realizado en hospital privado. Participaron 13 instrumentistas quirúrgicos. Los datos fueron colectados entre agosto y septiembre de 2022 por medio de entrevistas grabadas en audio. Como instrumento para colecta de los datos, se utilizó um guion estructurado, conteniendo siete preguntas, y cuestiones referentes al perfil de la muestra. Fueon incluidos técnicos de enfermería egre-sados, actuantes como instrumentistas quirúrgicos. Fueron excluidos instrumentistas ausentes en el período de la colecta de datos. Los datos fue-ron analizados por medio del análisis de contenido. Resultados: Con base en el análisis de los datos, emergieron cuatro categorías: protocolo de cirugía segura; control de materiales e instrumentales; desafíos en el seguimiento del protocolo de cirugía segura; facilitadores del seguimiento del protocolo de cirugía segura. Conclusión: Se pueden conocer las estrategias utilizadas por instrumentistas quirúrgicos para el control de los materiales dispuestos en la mesa de instrumentación durante el intraoperatorio. Prisa de profesionales, falta de adhesión y el no seguimiento de rutinas institucionales se caracterizan como desafíos para el seguimiento de las etapas del protocolo de cirugía segura