Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 973
Filtre
1.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 50-58, jan.-abr. 2024. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1553265

Résumé

As indicações de tratamento das fraturas mandibulares em paciente pediátrico variam em conservador, fixação não rígida e interna rígida. Alterações no crescimento ósseo, disfunções na articulação temporomandibular e assimetrias faciais podem ser decorrentes ao insucesso do tratamento. O objetivo deste trabalho consiste em relatar abordagem cirúrgica em fratura de sínfise e côndilo mandibular bilateral em paciente pediátrico. Paciente gênero feminino, 09 anos de idade, foi encaminhada ao Hospital Geral do Estado - Bahia vítima de queda de nível, cursando com trauma em face. Apresentou queixa principal, referida pela progenitora, de dificuldades em fechar a boca. Ao exame físico, a paciente apresentou mobilidade atípica à manipulação da mandíbula, mordida aberta anterior, equimose sublingual, ausência das unidades dentárias 74 e 75, com abertura bucal regular e suturas em posição em região de mento. Ao exame de imagem de tomografia computadorizada da face, pôde-se notar sinais sugestivos de fratura em região de sínfise e côndilos mandibulares bilateral. Após diagnóstico das fraturas, a paciente foi submetida à cirurgia sob anestesia geral para redução e fixação das mesmas. Realizou-se acessos em ferimento na região mentual e retromandibular bilateral com posterior síntese das fraturas utilizando fixação interna rígida com placas do sistema 2.0mm, associada a odontossíntese na fratura de sínfise. Ao acompanhamento periódico, a eleição do tratamento cirúrgico para fraturas mandibulares em pacientes pediátricos, pode permitir segurança no crescimento ósseo mandibular e facial(AU)


The indications for treatment of mandibular fractures in pediatric patients vary from conservative, non-rigid fixation and rigid internal fixation. Changes in bone growth, temporomandibular joint disorders and facial asymmetries may be due to treatment failure. The objective of this work is to report a surgical approach to bilateral symphysis and mandibular condyle fractures in a pediatric patient. Female patient, 9 years old, was sent to the State General Hospital - Bahia, victim of a fall in level, suffering from trauma to the face. She presented a main complaint, mentioned by her mother, of difficulties in closing her mouth. On physical examination, the patient presented atypical mobility when manipulating the jaw, anterior open bite, sublingual ecchymosis, absence of dental units 74 and 75, with regular mouth opening and sutures in position in the chin region. When examining the computed tomography image of the face, signs suggestive of fracture in the region of the symphysis and bilateral mandibular condyles were noted. After diagnosis of the fractures, the patient underwent surgery under general anesthesia to reduce and fix them. Access was performed on a wound in the mental and bilateral retromandibular region with subsequent synthesis of the fractures using rigid internal fixation with 2.0mm system plates, associated with odontosynthesis in the symphysis fracture. With periodic monitoring, the choice of surgical treatment for mandibular fractures in pediatric patients can allow for safe mandibular and facial bone growth(AU)


Sujets)
Humains , Femelle , Enfant , Ostéosynthèse interne , Menton/chirurgie , Menton/traumatismes , Condyle mandibulaire/chirurgie , Condyle mandibulaire/traumatismes
2.
China Journal of Orthopaedics and Traumatology ; (12): 86-91, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009228

Résumé

OBJECTIVE@#To investigate the clinical effect of total hip replacement (THA) in the treatment of traumatic arthritis secondary to acetabular fracture.@*METHODS@#From October 2019 to June 2022, 15 patients with secondary traumatic arthritis of acetabulum fracture were treated with THA. There were 8 males and 7 females, aged from 40 to 76 years old with an average of (59.20±9.46) years old. Prosthesis loosening, dislocation of hip joint, range of motion of hip joint, nerve injury and other conditions were recorded before and after surgery. Harris score, visual analogue scale (VAS) and imaging were used to evaluate hip joint function and surgical effect.@*RESULTS@#Follow-up time ranged 6 to 39 months with an average of (18.33±9.27) months. All the 15 patients successfully completed the operation, no nerve and blood vessel injury during the operation, postoperative wound healing was stageⅠ, no infection, one case of acetabular side prosthesis loosening at half a year after operation, and recovered well after revision surgery, one case of hip dislocation was cured after open reduction treatment, no adverse consequences. Harris score at the last postoperative follow-up was (88.60±4.01) points, compared with the preoperative (47.20±11.77) points, the difference was statistically significant (P<0.05), and VAS at the lateat postoperative follow-up was 1 (1) points, compared with the preoperative 8 (2) points, the difference was statistically significant (P<0.05). At the last follow-up, the pain symptoms were relieved or disappeared, and the joint function was satisfactory. The imaging data of the latest follow-up showed joint was well pseudoradiated, no abnormal ossification occurred, and the prosthesis was not loose.@*CONCLUSION@#THA is effective in the treatment of traumatic arthritis secondary to acetabular fracture and can effectively improve the quality of life of patients. Preoperative comprehensive evaluation and bone defect evaluation of patients, and intraoperative management of acetabulum, femur, internal fixation and bone defect are key factors for the success of surgery.


Sujets)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Sujet âgé , Arthroplastie prothétique de hanche/méthodes , Défaillance de prothèse , Études rétrospectives , Qualité de vie , Acétabulum/traumatismes , Prothèse de hanche , Fractures de la hanche/chirurgie , Fractures du rachis/chirurgie , Arthrite/chirurgie , Résultat thérapeutique , Études de suivi
3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 113-118, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009117

Résumé

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Sujets)
Humains , Phénomènes biomécaniques , Plaques orthopédiques , Ostéosynthèse interne , Ostéosynthese intramedullaire , Fractures du tibia/chirurgie ,
4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 28-34, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009104

Résumé

OBJECTIVE@#To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.@*METHODS@#A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.@*RESULTS@#All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).@*CONCLUSION@#Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.


Sujets)
Humains , Ostéosynthèse interne/méthodes , Études rétrospectives , Imagerie tridimensionnelle , Vis orthopédiques , Chirurgie assistée par ordinateur , Tomodensitométrie , Fractures du rachis/chirurgie , Fractures osseuses/chirurgie , Os coxal/traumatismes , Complications postopératoires , Traumatismes du cou
5.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 17-25, abr./jun 2023. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1537357

Résumé

Introdução: A osteotomia Le Fort I possibilita a correção de deformidades dentofaciais que envolvem o terço médio da face. Para sua fixação, convencionou-se o emprego de quatro mini-placas nos pilares zigomático-maxilar e nasomaxilar. Propôs-se então, a dispensa da fixação do segmento posterior, surgindo questionamentos relacionados à capacidade biomecânica do sistema. Objetivos: Comparar o estresse biomecânico gerado em três meios distintos de fixação da osteotomia Le Fort I frente ao movimento de avanço sagital linear maxilar de 7mm. Metodologia: Trata-se de uma pesquisa experimental laboratorial, utilizando-se da análise de elementos finitos como ferramenta analítica, a fim de constatar qual das técnicas sofrerá maior estresse biomecânico. Resultados: Constatou-se que o estresse biomecânico gerado é maior quando aplicado em 4 pontos do que quando aplicado em apenas 2 pontos. Conclusão: Os resultados obtidos fornecem informações aos cirurgiões sobre a real necessidade do uso de fixação adicional de acordo com o método de fixação planejado. No entanto, deve ser interpretado de forma cautelosa, considerando-se as limitações deste estudo. Sendo assim, uma análise incipiente, que tem como intuito o fornecimento de evidência científica de grande significância.


Introducción: La osteotomía Le Fort I permite la corrección de deformidades dentofaciales que involucran el tercio medio de la cara. Para su fijación se acordó utilizar cuatro miniplacas en los pilares cigomaticomaxilar y nasomaxilar. Entonces se propuso prescindir de la fijación del segmento posterior, planteando interrogantes relacionados con la capacidad biomecánica del sistema. Objetivos: Comparar el estrés biomecánico generado en tres medios diferentes de fijación de la osteotomía Le Fort I frente a un movimiento de avance sagital lineal maxilar de 7mm. Metodología: Se trata de una investigación experimental de laboratorio, utilizando como herramienta analítica el análisis de elementos finitos, con el fin de comprobar cuál de las técnicas sufrirá un mayor estrés biomecánico. Resultados: Se encontró que el estrés biomecánico generado es mayor cuando se aplica en 4 puntos que cuando se aplica solo en 2 puntos. Conclusión: Los resultados obtenidos brindan información a los cirujanos sobre la necesidad real de utilizar fijación adicional de acuerdo al método de fijación planificado. Sin embargo, debe interpretarse con cautela, considerando las limitaciones de este estudio. Por tanto, un análisis incipiente, que pretende aportar evidencias científicas de gran trascendencia.


Introduction: The Le Fort I osteotomy allows the correction of dentofacial deformities involving the middle third of the face. For its fixation, it was agreed to use four mini plates on the zygomaticomaxillary and nasomaxillary pillars. It was then proposed to dispense with the fixation of the posterior segment, raising questions related to the biomechanical capacity of the system. Objectives: To compare the biomechanical stress generated in three different means of fixation of the Le Fort I osteotomy against a 7mm maxillary linear sagittal advancement movement. Methodology: This is an experimental laboratory research, using finite element analysis as an analytical tool, in order to verify which of the techniques will suffer greater biomechanical stress. Results: It was found that the biomechanical stress generated is greater when applied to 4 points than when applied to only 2 points. Conclusion: The results obtained provide information to surgeons about the real need to use additional fixation according to the planned fixation method. However, it should be interpreted with caution, considering the limitations of this study. Therefore, an incipient analysis, which aims to provide scientific evidence of great significance.


Sujets)
Ostéotomie de Le Fort , Analyse des éléments finis , Chirurgie orthognathique , Ostéosynthèse interne
6.
Rev. bras. ortop ; 58(1): 42-47, Jan.-Feb. 2023. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1441348

Résumé

Abstract Objective To compare the clinical results between conservative (CS) and surgical treatment (CXS) of A3 and A4 fractures without neurological deficit. Methods Prospective observational study of patients with thoracolumbar fractures type A3 and A4. These patients were separated between the surgical and conservative groups, and evaluated sequentially through the numeric rating scale (NRS), Roland-Morris disability questionnaire (RMDQ), EuroQol-5D (EQ-5D) quality of life questionnaire, and Denis work scale (DWS) up to 2.5 years of follow-up. Results Both groups showed significant improvement, with no statistical difference in pain questionnaires (NRS: CXS 2.4 ± 2.6; CS 3.5 ± 2.6; p> 0.05), functionality (RMDQ: CS 7 ± 6.4; CXS 5.5 ± 5.2; p> 0.05), quality of life (EQ-5D), and return to work (DWS). Conclusion Both treatments are viable options with equivalent clinical results. There is a tendency toward better results in the surgical treatment of A4 fractures.


Resumo Objetivo Comparar os resultados clínicos entre os tratamentos conservador (CS) e cirúrgico (CXS) das fraturas A3 e A4 sem déficit neurológico. Métodos Estudo prospectivo observacional de paciente com fraturas toracolombares tipo A3 e A4. Esses pacientes foram separados entre os grupos cirúrgico e conservador e avaliados sequencialmente através da escala numérica de dor (NRS), do questionário de incapacidade de Roland-Morris (RMDQ), do EuroQol-5D (EQ-5D) e da escala de trabalho de Denis (DWS) até 2,5 anos de acompanhamento. Resultados Ambos os grupos apresentaram melhora significante, sem diferença estatística nos questionários de dor (NRS: CXS 2,4 ± 2,6; CS 3,5 ± 2,6; p> 0,05), funcionalidade (RMDQ: CS 7 ± 6,4; CXS 5,5 ± 5,2; p> 0,05), qualidade de vida (EQ-5D) e retorno ao trabalho (DWS). Conclusão Ambos os tratamentos são opções viáveis e com resultados clínicos equivalentes. Há uma tendência a melhores resultados no tratamento cirúrgico das fraturas A4.


Sujets)
Humains , Fractures du rachis/chirurgie , Résultat thérapeutique , Traitement conservateur , Ostéosynthèse interne
7.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6): 300-303, 2023.
Article Dans Chinois | WPRIM | ID: wpr-995944

Résumé

Objective:To observe the difference in the effect of simple titanium plate internal fixation and titanium plate internal fixation combined with titanium nail intermaxillary traction in the treatment of jaw fractures and their impact on the oral and maxillofacial function of patients.Methods:From August 2016 to May 2021, 94 patients with jaw fractures admitted to the Department of Stomatology, Linyi Central Hospital, Shandong (supplementing the gender, age range and average age of the patients), were divided into 47 cases in the control group, and the titanium plates were used alone, combined operation group 47 cases, titanium plate internal fixation combined with intermaxillary traction with titanium nails. The changes of oral and maxillofacial function and fracture healing were measured before operation and 3 months after operation, and the perioperative indicators and postoperative complications were recorded.Results:Three months after operation, the scores of maxillofacial function, mouth function and masticatory function in the combined operation group (0.52±0.09 points, 0.67±0.12 points, 0.58±0.08 points) were significantly lower than those in the control group (1.05±0.21 points, 1.14±0.22 points, 1.02±0.21 points) ( t=15.90, 12.86, 13.42, P<0.05). The effective rate of the combined operation group was 95.74% (45/47), which was significantly higher than that of the control group (80.85%, 38/47) (χ 2=5.05, P<0.05); there was no significant difference in operation time and hospitalization time between the groups ( P>0.05), the fracture healing time in the combined surgery group (65.02±7.06) d was significantly shorter than that in the control group (82.69±10.25) d ( t=9.73, P<0.05). The postoperative complication rate of combined treatment group was 6.38% (3/47), which was significantly lower than the control group 21.28% (10/47) (χ 2=4.37, P<0.05). Conclusions:In the treatment of jaw fractures, titanium plate internal fixation combined with titanium nail intermaxillary traction treatment can significantly improve the oral and maxillofacial function of patients, promote postoperative fracture healing, improve curative effect and reduce the incidence of complications compared with simple titanium plate internal fixation.

8.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 810-814, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981672

Résumé

OBJECTIVE@#To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.@*METHODS@#The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.@*RESULTS@#After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.@*CONCLUSION@#Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.


Sujets)
Mâle , Femelle , Humains , Adolescent , Études rétrospectives , Ulna/chirurgie , Ostéochondrodysplasies , Fractures du radius/chirurgie , Articulation du poignet/chirurgie , Ostéotomie , Amplitude articulaire , Résultat thérapeutique
9.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 694-699, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981654

Résumé

OBJECTIVE@#To evaluate the effectiveness of limited internal fixation combined with a hinged external fixator in the treatment of peri-elbow bone infection.@*METHODS@#The clinical data of 19 patients with peri-elbow bone infection treated with limited internal fixation combined with a hinged external fixator between May 2018 and May 2021 were retrospectively analyzed. There were 15 males and 4 females with an average age of 44.6 years (range, 28-61 years). There were 13 cases of distal humerus fractures and 6 cases of proximal ulna fractures. All the 19 cases were infected after internal fixation of fracture, and 2 cases were complicated with radial nerve injury. According to Cierny-Mader anatomical classification, 11 cases were type Ⅱ, 6 cases were type Ⅲ, and 2 cases were type Ⅳ. The duration of bone infection was 1-3 years. After primary debridement, the bone defect was (3.04±0.28) cm, and the antibiotic bone cement was implanted into the defect area, and the external fixator was installed; 3 cases were repaired with latissimus dorsi myocutaneous flap, and 2 cases were repaired with lateral brachial fascial flap. Bone defects repair and reconstruction were performed after 6-8 weeks of infection control. The wound healing was observed, and white blood cell (WBC), erythrocyte sedimentation rate (ESR), and C-reaction protein (CRP) were reexamined regularly after operation to evaluate the infection control. X-ray films of the affected limb were taken regularly after operation to observe the bone healing in the defect area. At last follow-up, the flexion and extension range of motion and the total range of motion of the elbow joint were observed and recorded, and compared with those before operation, and the function of the elbow joint was evaluated by Mayo score.@*RESULTS@#All patients were followed up 12-34 months (mean, 26.2 months). The wounds healed in 5 cases after skin flap repair. Two cases of recurrent infection were effectively controlled by debridement again and replacement of antibiotic bone cement. The infection control rate was 89.47% (17/19) in the first stage. Two patients with radial nerve injury had poor muscle strength of the affected limb, and the muscle strength of the affected limb recovered from grade Ⅲ to about grade Ⅳ after rehabilitation exercise. During the follow-up period, there was no complication such as incision ulceration, exudation, bone nonunion, infection recurrence, or infection in the bone harvesting area. Bone healing time ranged from 16 to 37 weeks, with an average of 24.2 weeks. WBC, ESR, CRP, PCT, and elbow flexion, extension, and total range of motions significantly improved at last follow-up ( P<0.05). According to Mayo elbow scoring system, the results were excellent in 14 cases, good in 3 cases, and fair in 2 cases, and the excellent and good rate was 89.47%.@*CONCLUSION@#Limited internal fixation combined with a hinged external fixator in the treatment of the peri-elbow bone infection can effectively control infection and restore the function of the elbow joint.


Sujets)
Mâle , Femelle , Humains , Adulte , Coude , Articulation du coude/chirurgie , Études rétrospectives , Ciments osseux , Résultat thérapeutique , Fixateurs externes , Ostéosynthèse interne/méthodes , Fractures osseuses , Amplitude articulaire
10.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 688-693, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981653

Résumé

OBJECTIVE@#The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.@*METHODS@#Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.@*RESULTS@#In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).@*CONCLUSION@#Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.


Sujets)
Humains , Femelle , Sujet âgé , Analyse des éléments finis , Phénomènes biomécaniques , Ostéosynthèse interne/méthodes , Fractures de la hanche/chirurgie , Plaques orthopédiques , Tête du fémur , Fractures du fémur/chirurgie
11.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 681-687, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981652

Résumé

OBJECTIVE@#To investigate the effectiveness of joystick technique assisted closed reduction and cannulated screw fixation in the treatment of femoral neck fracture.@*METHODS@#Seventy-four patients with fresh femoral neck fractures who met the selection criteria between April 2017 and December 2018 were selected and divided into observation group (36 cases with closed reduction assisted by joystick technique) and control group (38 cases with closed manual reduction). There was no significant difference in gender, age, fracture side, cause of injury, Garden classification, Pauwels classification, time from injury to operation, and complications (except for hypertension) between the two groups ( P>0.05). The operation time, intraoperative infusion volume, complications, and femoral neck shortening were recorded and compared between the two groups. Garden reduction index was used to evaluate the effect of fracture reduction, and score of fracture reduction (SFR) was designed and was used to evaluate the subtle reduction effect of joystick technique.@*RESULTS@#The operation was successfully completed in both groups. There was no significant difference in operation time and intraoperative infusion volume between the two groups ( P>0.05). All patients were followed up 17-38 months, with an average of 27.7 months. Two patients in the observation group received joint replacement due to failure of internal fixation during the follow-up, and the other patients had fracture healing. Within 1 week after operation, the Garden reduxtion index of the observation group was better than the control group; the SFR score of the observation group was also higher than that of the control group; the proportion of femoral neck shortening within 1 week after operation and at 1 year after operation in the observation group were lower than those in the control group. The differences of the above indexes between the two groups were significant ( P<0.05).@*CONCLUSION@#The joystick technique can improve the effectiveness of closed reduction of femoral neck fractures and reduce the incidence of femoral neck shortening. The designed SFR score can directly and objectively evaluate the reduction effect of femoral neck fracture.


Sujets)
Humains , Résultat thérapeutique , Vis orthopédiques , Fractures du col fémoral/chirurgie , , Ostéosynthèse interne/méthodes , Études rétrospectives
12.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 572-577, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981634

Résumé

OBJECTIVE@#To compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation.@*METHODS@#The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups ( P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function.@*RESULTS@#There was no significant difference in operation time between the two groups ( P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference ( t=-0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values ( P<0.05). However, there was no significant difference in the improvement value between the two groups ( P>0.05).@*CONCLUSION@#For PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.


Sujets)
Humains , Ligament croisé postérieur/traumatismes , Ancres de suture , Fractures-avulsions/chirurgie , Études rétrospectives , Fractures du tibia/chirurgie , Arthroscopie/méthodes , Ostéosynthèse interne/méthodes , Articulation du genou/chirurgie , Vis orthopédiques , Techniques de suture , Résultat thérapeutique
13.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 410-416, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981607

Résumé

OBJECTIVE@#To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.@*METHODS@#A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.@*RESULTS@#All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).@*CONCLUSION@#For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.


Sujets)
Mâle , Femelle , Humains , Adulte , Études rétrospectives , Perte sanguine peropératoire , , Résultat thérapeutique , Plaques orthopédiques , Fractures du tibia/chirurgie , Articulation du genou , Ostéosynthèse interne , Ostéotomie , Mise en charge
14.
Chinese Journal of Medical Instrumentation ; (6): 312-316, 2023.
Article Dans Chinois | WPRIM | ID: wpr-982235

Résumé

This study briefly introduces the revised content of Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021) compared to the original guidance, mainly including the principles of dividing registration unit, main performance indicators of standard specification, physical and mechanical performance research, and clinical evaluation. At the same time, in order to provide some references for the registration of metallic bone plate internal fixation system, this study analyzes the main concerns in the review process of these products based on the accumulation of experience combining with the current review requirements.


Sujets)
Plaques orthopédiques , Ostéosynthèse interne , Phénomènes biomécaniques
15.
China Journal of Orthopaedics and Traumatology ; (12): 635-640, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981747

Résumé

OBJECTIVE@#To investigate the clinical efficacy of femoral neck system(FNS) and three cannulated compression screws(CCS) in the treatment of unstable femoral neck fractures in young adults.@*METHODS@#The clinical data of 52 young and middle-aged patients with unstable femoral neck fractures admitted from August 2018 to August 2021 were reviewed and analyzed. All patients were divided into two groups according to the internal fixation method, 25 cases were treated with FNS fixation, 27 cases were treated with closed reduction and 3 CCS inverted triangular distribution. The operation time, incision length, intraoperative bleeding, hospitalization expenses and fracture reduction quality of two groups were recorded and compared;The patients were followed up regularly after operation. The fracture healing time, complete weight-bearing time and postoperative complications(nonunion, femoral neck shortening, femoral head necrosis) of two groups were compared. The Harris score was used to evaluate hip function 6 months after surgery.@*RESULTS@#The operation was successfully completed in both groups. The patients in FNS group had more bleeding, longer incision length and higher hospitalization cost than CCS group(P<0.01). There ware no significant difference in operation time and Garden index between two groups(P>0.05). Patients in both groups were followed up for 6 to 32 months.The fracture healing time in FNS group was less than that in CCS group, the time of complete weight bearing after surgery was earlier than that in CCS group, and the hip Harris score was higher than that in CCS group (P<0.01). There were no internal fixation fracture complications in two groups during follow-up. In the FNS group, there were 4 cases of avascular necrosis of the femoral head and 2 cases of femoral neck shortening, of which 3 cases underwent total hip replacement due to avascular necrosis of the femoral head. In the CCS group, there were 2 cases of nonunion, 9 cases of avascular necrosis of the femoral head, and 11 cases of femoral neck shortening, among which 5 cases underwent total hip replacement due to nonunion and avascular necrosis of the femoral head.@*CONCLUSION@#With simple operation, rotational stability and angular stability, FNS enables patients to start functional exercise as early as possible and reduces the incidence of postoperative complications of unstable femoral neck fracture. It is a new choice for the treatment of unstable femoral neck fracture in young adults.

16.
China Journal of Orthopaedics and Traumatology ; (12): 614-618, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981743

Résumé

OBJECTIVE@#To investigate the risk factors of elbow stiffness after open reduction and internal fixation of intercondylar fracture of humerus.@*METHODS@#From March 2015 to February 2019, 120 patients with humeral intercondylar fractures were treated with open fixation including 59 males and 61 females, aged from 25 to 77 years with an average of(53.5±3.2) years. According to the occurrence of elbow stiffness after operation, 120 patients were divided into stiffness group(37 cases) and control group(83 cases). The related factors of elbow stiffness were analyzed by single factor analysis, and the risk of elbow stiffness after internal fixation of humeral intercondylar fracture was analyzed by logistic regression factor.@*RESULTS@#There were 37 cases of elbow stiffness(stiff group), and 83 cases had no elbow stiffness(control group). The incidence of joint stiffness was 30.83%. There were significant differences between the stiffness group and the control group in age, injury energy, fracture to operation time, AO classification of fracture, open injury and postoperative premature or hyperactivity. Multivariate logistic regression analysis showed that age>50 years old, high energy injury, AO classification of fracture, open fracture and postoperative premature or hyperactivity were risk factors for elbow stiffness after internal fixation of humeral intercondylar fracture. The postoperative mobility and Mayo elbow performance score(MEPS) scores of the postoperative stiffness group were lower than those of the non-stiffness group with statistical significance(P<0.05). There were no significant differences in postoperative mobility and MEPS scores between flexion stiffness and rotation stiffness after humeral intercondylar fracture(P>0.05).@*CONCLUSION@#In view of the risk factors of elbow stiffness after internal fixation of humeral intercondylar fracture, reasonable operation plan and rehabilitation strategy should be formulated before operation to minimize the incidence of elbow stiffness.

17.
China Journal of Orthopaedics and Traumatology ; (12): 574-578, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981735

Résumé

OBJECTIVE@#To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.@*METHODS@#This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.@*RESULTS@#The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.@*CONCLUSION@#Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.


Sujets)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Sujet âgé , Études rétrospectives , Reproductibilité des résultats , Fractures du radius/chirurgie , Ostéosynthèse interne/méthodes , Résultat thérapeutique , , Articulation du poignet , Plaques orthopédiques , Amplitude articulaire
18.
China Journal of Orthopaedics and Traumatology ; (12): 440-444, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981712

Résumé

OBJECTIVE@#To compare the clinical efficacy of micro steel plate and Kirschner needle oblique and transverse internal fixation of adjacent metacarpal bone in the treatment of metacarpal diaphyseal oblique fracture.@*METHODS@#Fifty-nine patients with metacarpal diaphyseal oblique fractures admitted between January 2018 and September 2021 were selected as the study subjects and divided into the observation group (29 cases) and the control group (30 cases) based on different internal fixation methods. The observation group was treated with Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones, while the control group was treated with micro steel plate internal fixation. Postoperative complications, operation time, incision length, fracture healing time, treatment cost, and metacarpophalangeal function were compared between the two groups.@*RESULTS@#No incision or Kirschner wire infections occurred in the 59 patients, except for one in the observation group. No fixation loosening, rupture, or loss of fracture reduction occurred in any of the patients. The operation time and incision length in the observation group were (20.5±4.2) min and (1.6±0.2) cm, respectively, which were significantly shorter than those in the control group (30.8±5.6) min and (4.3±0.8) cm (P<0.05). The treatment cost and fracture healing time in the observation group were (3 804.5±300.8) yuan and (7.2±1.1) weeks, respectively, which were significantly lower than those in the control group (9 906.9±860.6) yuan and (9.3±1.7) weeks (P<0.05). The excellent and good rate of metacarpophalangeal joint function in the observation group was significantly higher than that in the control group at 1, 2, and 3 months after operation (P<0.05), but there was no significant difference between the two groups at 6 months after operation (P>0.05).@*CONCLUSION@#Micro steel plate internal fixation and Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones are both viable surgical methods for treating metacarpal diaphyseal oblique fractures. However, the latter has the advantages of causing less surgical trauma, shorter operation time, better fracture healing, lower cost of fixation materials, and no need for secondary incision and removal of internal fixation.


Sujets)
Humains , Os du métacarpe/traumatismes , Fractures osseuses/chirurgie , Ostéosynthèse interne/méthodes , Fils métalliques , Plaques orthopédiques , Résultat thérapeutique
19.
China Journal of Orthopaedics and Traumatology ; (12): 406-413, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981706

Résumé

OBJECTIVE@#To analyze the causes of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy, summarize the clinical results, and propose preventive measures.@*METHODS@#Retrospective analysis was made on the data of 8 cases of lumbar spondylopathy and vertebral fracture treated by oblique lateral interbody fusion in three medical centers from October 2014 to December 2018. All were female, aged from 50 to 81 years with an average of 66.4 years. Disease types included 1 case of lumbar degenerative disease, 3 cases of lumbar spinal stenosis, 2 cases of lumbar degenerative spondylolisthesis and 2 cases of lumbar degenerative scoliosis. Preoperative dual energy X-ray bone mineral density test showed that 2 cases had T-value >-1 SD, 2 cases had T-value -1 to -2.5 SD, and 4 cases had T-value <-2.5 SD. Single segment fusion was in 5 cases, two segment fusion in 1 case and three segment fusion in 2 cases. Four cases were treated with OLIF Stand-alone and 4 cases were treated with OLIF combined with posterior pedicle screw fixation. Postoperative imaging examination showed vertebral fracture, and all of them were single vertebral fracture. There were 2 cases of right lower edge fracture of upper vertebral body at fusion segment, 6 cases of lower vertebral body fracture at fusion segment, and 6 cases with endplate injury and fusion cage partially embedded in vertebral body. Three cases of OLIF Stand-alone were treated with pedicle screw fixation via posterior intermuscular approach, while one case of OLIF Stand-alone and four cases of OLIF combined with posterior pedicle screw fixation were not treated specially.@*RESULTS@#The 5 cases of initial operation and 3 cases of reoperation did not show wound skin necrosis or wound infection. The follow-up time was from 12 to 48 months with an average of 22.8 months. Visual analogue scale (VAS) of low back pain was preoperative decreased from 4 to 8 points (averagely 6.3 points) and postoperative 1 to 3 points (averagely 1.7 points) at the final follow-up. Oswestry disability index (ODI) was preoperative 39.7% to 52.4% (averagely 40.2%), and postoperative 7.9% to 11.2% (averagely 9.5%) at the final follow-up. During the follow-up, there was no loosening or fracture of the pedicle screw system, and no lateral displacement of the fusion cage;however, the fusion cage at the vertebral fracture segment had obvious subsidence. The intervertebral space height of vertebral fracture segment was preoperaive 6.7 to 9.2 mm (averagely 8.1 mm), and postoperative 10.5 to 12.8 mm (averagely 11.2 mm). The improvement rate after operation was 37.98% compared to preoperative. The intervertebral space height at final follow-up was 8.4 to 10.9 mm (averagely 9.3 mm), and the loss rate was 16.71% compared with that after operation. At the final follow-up, interbody fusion was achieved in all cases except for one that could not be identified.@*CONCLUSION@#The incidence of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy is lower, and there are many reasons for fracture, including preoperative bone loss or osteoporosis, endplate injury, irregular shape of endplate, excessive selection of fusion cage, and osteophyte hyperplasia at the affected segment. As long as vertebral fracture is found in time and handled properly, the prognosis is well. However, it still needs to strengthen prevention.


Sujets)
Humains , Femelle , Mâle , Fractures du rachis/chirurgie , Études rétrospectives , Résultat thérapeutique , Vertèbres lombales/chirurgie , Spondylolisthésis/chirurgie , Scoliose , Arthrodèse vertébrale/méthodes
20.
China Journal of Orthopaedics and Traumatology ; (12): 376-380, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981700

Résumé

OBJECTIVE@#To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.@*METHODS@#From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.@*RESULTS@#All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.@*CONCLUSION@#Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.


Sujets)
Adulte , Sujet âgé , Animaux , Femelle , Humains , Mâle , Adulte d'âge moyen , Jeune adulte , Plaques orthopédiques , Ostéosynthèse interne/méthodes , Radius/chirurgie , Fractures du radius/chirurgie , Amplitude articulaire , Résultat thérapeutique , Articulation du poignet
SÉLECTION CITATIONS
Détails de la recherche