Malaysian Orthopaedic Journal ; : 66-68, 2012.
Article Dans Anglais | WPRIM | ID: wpr-625789

Résumé

We report a method for removing the distal segment of a broken locked intramedullary nail secondary to nonunion of the femur following radiotherapy for fibromatosis. A Kirschner wire with one tip fashioned into a hook was used to remove the distal segment without opening with the nonunion site. Details of the procedure are described.

2.
The Journal of the Korean Orthopaedic Association ; : 85-86, 2003.
Article Dans Coréen | WPRIM | ID: wpr-655582

Résumé

Fractures of the humeral shaft are commonly encountered by orthopaedic surgeons, mainly in the age group ranging between adolescence and adult, in which treatment can be mananged operatively using plate and screws, intramedullary nail or external fixator. In this case, a patient had an operation for humerus shaft fracture, an intramedullary nail was applied and bone union occured. When removing the metal, and because the proximal entry of the intramedullary nail could not be tightly interlocked with the metal removal set due to entry screw thread wear, it was necessary to devise a certain tool. A 6.5 mm diameter cannulated screw was used as a alternative device for removal of interlocking intramedullary nail.