Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres








Gamme d'année
1.
Chinese Journal of Hematology ; (12): 411-416, 2019.
Article de Chinois | WPRIM | ID: wpr-810640

RÉSUMÉ

Objectives@#To assess the diagnostic values of latex immunoturbidimetric assay (LIA) and particle immunofiltration assay (PIFA) for heparin-induced thrombocytopenia (HIT) .@*Methods@#Samples from 94 patients with suspected HIT from May 2016 to July 2018 in our hospital were prospectively analyzed by the two immunoassays. Their medical records and further follow-up data were also collected and analyzed by our hematologists to make the 4Ts scores and confirm the diagnosis of HIT, respectively. Performance characteristics of the two immunoassays were assessed, including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) . Their post-test probabilities (PTP) were also calculated based on the 4Ts score.@*Results@#Among 94 cases, 15 (16.0%) had a positive HIT, including 6 of 37 (16.2%) with an intermediate, and 9 of 15 (60.0%) with a high 4Ts score. PIFA operating characteristics were: sensitivity 100.0% (15/15) , specificity 51.9% (41/80) , PPV 28.3% (15/53) , NPV 100.0% (41/41) . The positive PTP in intermediate and high 4Ts score group were 28.7% and 75.7%, respectively, while negative PTP were all 0. At manufacturers’ cutoffs, LIA operating characteristics were: sensitivity 66.7% (10/15) , specificity 94.9% (75/79) , PPV 71.4% (10/14) and NPV 93.8% (75/80) . The positive and negative PTP in intermediate 4Ts score group were 71.8% and 6.3%, while 95.2% and 34.4% in high 4Ts score group, respectively. Receiver operating characteristic (ROC) analysis manifested that LIA was preferable than PIFA, and combining the 2 assays together was significantly better than single test.@*Conclusions@#4Ts score is still an important tool for the diagnosis of HIT. Combining clinical score with heparin/PF4 antibody assay can increase the accuracy of confirming or excluding HIT. Although PIFA is inferior to LIA in the diagnostic value, its user friendliness and 100% NPV have major advantages. Combining the 2 assays together can achieve a higher diagnostic value.

2.
Chinese Journal of Hematology ; (12): 411-416, 2019.
Article de Chinois | WPRIM | ID: wpr-1012002

RÉSUMÉ

Objectives: To assess the diagnostic values of latex immunoturbidimetric assay (LIA) and particle immunofiltration assay (PIFA) for heparin-induced thrombocytopenia (HIT) . Methods: Samples from 94 patients with suspected HIT from May 2016 to July 2018 in our hospital were prospectively analyzed by the two immunoassays. Their medical records and further follow-up data were also collected and analyzed by our hematologists to make the 4Ts scores and confirm the diagnosis of HIT, respectively. Performance characteristics of the two immunoassays were assessed, including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) . Their post-test probabilities (PTP) were also calculated based on the 4Ts score. Results: Among 94 cases, 15 (16.0%) had a positive HIT, including 6 of 37 (16.2%) with an intermediate, and 9 of 15 (60.0%) with a high 4Ts score. PIFA operating characteristics were: sensitivity 100.0% (15/15) , specificity 51.9% (41/80) , PPV 28.3% (15/53) , NPV 100.0% (41/41) . The positive PTP in intermediate and high 4Ts score group were 28.7% and 75.7%, respectively, while negative PTP were all 0. At manufacturers' cutoffs, LIA operating characteristics were: sensitivity 66.7% (10/15) , specificity 94.9% (75/79) , PPV 71.4% (10/14) and NPV 93.8% (75/80) . The positive and negative PTP in intermediate 4Ts score group were 71.8% and 6.3%, while 95.2% and 34.4% in high 4Ts score group, respectively. Receiver operating characteristic (ROC) analysis manifested that LIA was preferable than PIFA, and combining the 2 assays together was significantly better than single test. Conclusions: 4Ts score is still an important tool for the diagnosis of HIT. Combining clinical score with heparin/PF4 antibody assay can increase the accuracy of confirming or excluding HIT. Although PIFA is inferior to LIA in the diagnostic value, its user friendliness and 100% NPV have major advantages. Combining the 2 assays together can achieve a higher diagnostic value.


Sujet(s)
Humains , Anticorps , Anticoagulants , Test ELISA , Héparine/effets indésirables , Dosage immunologique , Facteur-4 plaquettaire , Thrombopénie/induit chimiquement
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE