Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
1.
Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1088976

Résumé

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Sujet âgé , Phacoémulsification/méthodes , Cornée/anatomopathologie , Topographie cornéenne/instrumentation , Pose d'implant intraoculaire/méthodes , Lentilles intraoculaires multifocales , Chambre antérieure du bulbe oculaire/anatomopathologie , Période postopératoire , Valeurs de référence , Réfraction oculaire/physiologie , Facteurs temps , Acuité visuelle/physiologie , Valeur prédictive des tests , Études rétrospectives , Biométrie , Résultat thérapeutique , Cornée/imagerie diagnostique , Interférométrie/instrumentation , Interférométrie/méthodes , Chambre antérieure du bulbe oculaire/imagerie diagnostique
2.
Arq. bras. oftalmol ; 82(5): 389-393, Sept.-Oct. 2019. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1019426

Résumé

ABSTRACT Purpose: To evaluate the efficacy and safety of the modified Yamane technique with sutureless transconjunctival intrascleral intraocular lens fixation. Methods: Sutureless transconjunctival intrascleral haptic fixated intraocular lens implantation was performed in patients with aphakia and dislocated intraocular lenses. A clear corneal incision (2.8 mm) was made into the temporal quadrant and a three-piece intraocular lens was implanted into the anterior chamber. The haptics of the intraocular lens were externalized with a 27 G needle via transconjunctival scleral tunnels at the 6 and 12 o'clock positions. The transconjunctival scleral tunnels were prepared to conform to the haptic position and curvature. The site of the scleral tunnels was 2mm from the limbus with a length of 2 mm in the sclera and was aimed at the end of the posterior chamber. The tips of the haptics were cauterized to create a terminal knob. The haptics were pushed back and the knobs were implanted into the scleral tunnels. Results: The study cohort included 21 patients with unilateral aphakia and dislocated intraocular lenses. All patients were examined postoperatively and at postoperative day 1, day 7, month 1, and month 3. All examinations revealed formation of the anterior chamber and well-centralized intraocular lenses. No haptic-related complications of exposure, foreign body sensation, or discomfort were observed. Conclusion: Sutureless transconjunctival intrascleral haptic fixated intraocular lensimplantation is an effective, safe, and practical surgical alternative. This technique was superior to the Yamane method with regard to comfort and surgical duration. Further studies with longer follow-up evaluations are warranted to verify long-term complications.


RESUMO Objetivo: Avaliar a eficácia e a segurança da técnica de Yamane modificada com a fixação de lenta intraocular transconjuntival sem sutura. Métodos: O implante de lente intraocular intraescleral e transconjuntival sem sutura foi realizado em pacientes com afacia e lentes intraoculares luxadas. Uma incisão em córnea clara (2,8 mm) foi feita no quadrante temporal e uma lente intraocular de três peças foi implantada na câmara anterior. Os hápticos da lente intraocular foram externalizados com uma agulha 27G através de túneis esclerais transconjuntivais nas posições de 6 e 12 horas. Os túneis esclerais transconjuntivais foram preparados para se ajustarem à posição e curvatura hápticas. O local dos túneis esclerais foi de 2 mm do limbo com um comprimento de 2 mm na esclera e foi destinado ao final da câmara posterior. As pontas dos hápticos foram cauterizadas para criar uma saliência terminal. Os hápticos foram empurrados para tras e as saliências foram implantadas nos túneis esclerais. Resultados: A coorte do estudo incluiu 21 pacientes com afacia unilateral e lentes intraocular deslocada. Todos os pacientes foram examinados no pós-operatório e no dia 1, 7, 1 mês e 3 meses do pós-operatório. Todos os exames revelaram formação da uma câmara anterior e lentes intraoculares bem centralizadas. Nenhuma complicação hápticas relacionada à exposição, sensação de corpo estranho ou desconforto foram observadas. Conclusão: O implante de lente intraocular transconjuntival intraescleral sem sutura é uma alternativa cirúrgica eficaz, segura e prática. Esta técnica foi superior ao método de Yamane no que diz respeito ao conforto e duração cirúrgica. Mais estudos com avaliações de seguimento mais prolongados são necessários para verificar as complicações de longo prazo.


Sujets)
Humains , Mâle , Femelle , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Aphakie après chirurgie de la cataracte/chirurgie , Sclère/chirurgie , Pose d'implant intraoculaire/méthodes , Aphakie après chirurgie de la cataracte/physiopathologie , Sclère/physiopathologie , Acuité visuelle , Techniques de suture , Interventions chirurgicales sans suture , Lentilles intraoculaires , Chambre antérieure du bulbe oculaire/chirurgie
SÉLECTION CITATIONS
Détails de la recherche