Chinese Journal of Medical Instrumentation ; (6): 140-142, 2019.
Article Dans Chinois | WPRIM | ID: wpr-772543

Résumé

OBJECTIVE@#Based on the Magphan phantom,a baseline value of low contrast resolution was established,and the stability of the imaging performance of the system was monitored.Drift and correction were found in time to give full play to the performance of the device.@*METHODS@#The general test evaluation method for low-contrast resolution was not suitable for the characteristics of long-term monitoring equipment performance changes,and the test evaluation of low-contrast resolution that incorporates the -test method in statistical principle was proposed.@*RESULTS@#By analyzing and evaluating the test results of the low contrast resolution of the standard water model image,and verifying the correctness of the evaluation method,according to the correct test method,the test statistic value was used as the low contrast resolution value of the MRI equipment to test the boundary of the region.The value was used as a baseline value for low contrast resolution to establish a long-term stable quality assurance system.@*CONCLUSIONS@#In this paper,the data of the low contrast resolution test on Magphan phantom was in line with practical experience,therefore the test method of low contrast resolution was verified.The baseline value of the indicator can be established based on the detection and evaluation method of low contrast resolution based on phantom,then to ensure the stability of the imaging performance of the system.


Sujets)
Produits de contraste , Imagerie par résonance magnétique , Fantômes en imagerie
2.
Chinese Medical Equipment Journal ; (6): 16-19,23, 2017.
Article Dans Chinois | WPRIM | ID: wpr-659375

Résumé

Objective To design and implement an automatic analysis and evaluation system for the image parameters of medical MRI quality testing.Methods The system was developed and debugged by the study on MRI image quality parameters,the image denoising,integration,extraction and etc by MATLAB processing platform as well as the comparison and comparative calculation of the obtained data.Results The system replaced manual operation by auto processing and parameters analysis of MRI quality inspection image.Conclusion The system enhances the efficiency and avoids artificial error,and has a promising prospect in the future.

3.
Chinese Medical Equipment Journal ; (6): 16-19,23, 2017.
Article Dans Chinois | WPRIM | ID: wpr-662094

Résumé

Objective To design and implement an automatic analysis and evaluation system for the image parameters of medical MRI quality testing.Methods The system was developed and debugged by the study on MRI image quality parameters,the image denoising,integration,extraction and etc by MATLAB processing platform as well as the comparison and comparative calculation of the obtained data.Results The system replaced manual operation by auto processing and parameters analysis of MRI quality inspection image.Conclusion The system enhances the efficiency and avoids artificial error,and has a promising prospect in the future.