Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Article Dans Chinois | WPRIM | ID: wpr-856646

Résumé

Objective: To evaluate the effect of nickel-titanium three-dimensional memory alloy mesh combined with autologous bone for living model of canine tibial plateau collapse fracture by biomechanical testing. Methods: Sixteen healthy 12-month-old Beagle dogs were randomly divided into 4 group, 4 dogs in each group. The dogs were used to establish the tibial plateau collapse fracture model in groups A, B, and C. Then, the nickel-titanium three-dimensional memory alloy mesh combined with autologous bone (the fibula cortical bone particles), the artificial bone (nano-hydroxyapatite), and autologous fibula cortical bone particles were implanted to repair the bone defects within 4 hours after modeling in groups A, B, and C, respectively; and the plate and screws were fixed outside the bone defects. The dogs were not treated in group D, as normal control. At 5 months after operation, all animals were sacrificed and the tibial specimens were harvested and observed visually. The destructive axial compression experiments were carried out by the biomechanical testing machine. The displacement and the maximum failure load were recorded and the axial stiffness was calculated. Results: All animals stayed alive after operation, and all incisions healed. After 1-3 days of operation, the animals could stand and move, and no obvious limb deformity was found. The articular surfaces of the tibial plateau specimens were completely smooth at 5 months after operation. No obvious articular surface collapse was observed. The displacement and maximum failure load of specimens in groups A and D were significantly higher than those in groups B and C ( P0.05). Conclusion: The nickel-titanium three-dimensional memory alloy mesh combined with autologous bone for subarticular bone defect of tibial plateau in dogs has good biomechanical properties at 5 months after operation, and has better axial stiffness when compared with the artificial bone and autologous bone graft.

2.
Article Dans Chinois | WPRIM | ID: wpr-749771

Résumé

@#Objective     To compare clinical outcomes between the performed titanium locking plate and nickel-titanium memory alloy embracing fixator for the treatment of multiple rib fractures, and to select a better internal fixator for multiple rib fractures. Methods     A total of 206 consecutive patients with multiple rib fractures were admitted to Department of Cardiothoracic Surgery in Beijing Luhe Hospital of Capital Medical University from October 2011 to September 2016. According to different treatment strategies, the patients were divided into 2 groups: a performed titanium locking plate group (a titanium plate group, n=105) and a nickel-titanium memory alloy embracing fixator group (an embracing fixator group, n=101). There were 82 males and 23 females with a mean age of 46.5±9.7 years ranging from 23 to 65 years in the titanium plate group, and 83 males and 18 females with a mean age of 44.7±10.3 years ranging from 19 to 63 years in the embracing fixator group. The preoperative data, curative outcomes, visual analogue scale (VAS) and postoperative complications were compared between the two groups. Results     There was no statistical difference in the preoperative data between the two groups, and all patients successfully completed the operation. Compared with the embracing fixator group, the incision length and operation time were shorter, intraoperative bleeding and VAS score were less, and curative outcome was better in the titanium plate group. Conclusion     The performed titanium locking plate has a great advantage in the clinic, which can be preferred.

3.
Article Dans Chinois | WPRIM | ID: wpr-448329

Résumé

To compare the effect of surgical and non-surgical treatment for multiple fractured ribs retrospectively, with 30 cases in each group. Patient's length of stay, visual analogue scale ( VAS) pain, independent ambulation time, cost of hospitalization, thoracoplasty degree and the lung ventilation function were evaluated. The results showed that VAS declined obviously in patients of surgical group, length of stay and independent ambulation time were shorter. Compared to the non-surgical group, the maximal voluntary ventilation increased significantly and ref-erral rib reduction was significantly better, but cost of the surgical group was higher. It's an effective treatment for using nickel titanium memory alloy embracing fixator in the treatment of multiple fractured rips, and is worthy of clinical application.

SÉLECTION CITATIONS
Détails de la recherche