Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Rev. Pesqui. Fisioter ; 12(1)jan., 2022. ilus, tab
Article Dans Anglais, Portugais | LILACS | ID: biblio-1417280

Résumé

INTRODUÇÃO: Diferentes protocolos do teste de elevação do calcanhar (TEC) têm sido utilizados, sendo necessário analisar o impacto das variações nas respostas do teste. OBJETIVO: Comparar o desempenho e respostas de oxigenação muscular (OM) e frequência cardíaca (FC) de adultos em diferentes protocolos do TEC bipodal. MATERIAIS E MÉTODOS: Este foi um estudo transversal do tipo cruzado. Trinta participantes (23,1±2,9 anos; 16 homens) realizaram quatro protocolos do TEC bipodal, variando cadenciamento (autocadenciado e cadenciado externamente) e posição dos tornozelos (neutra e dorsiflexão). Para a OM, analisamos a saturação tecidual de oxigênio (StO2 ) e variação da concentração de oxihemoglobina (∆[O2 Hb]) e calculamos a variação entre os menores valores e os valores finais (∆Nadir-Final) e área sob a curva (AUC). Para a FC, calculamos a variação dos valores iniciais e finais (∆FC) e constante de tempo (τ). O teste de Friedman foi utilizado para comparar as variáveis entre os protocolos. A ANOVA de dois fatores foi utilizada para identificar o impacto da cadência e/ou posição dos tornozelos. RESULTADOS: O número de repetições e o tempo de execução foram maiores nos protocolos em posição neutra e cadenciado externamente (p<0,001 para ambos). ∆Nadir-Final (StO2: p<0,001; ∆[O2Hb]: p=0,005) e AUC (StO2: p<0,001; ∆[O2Hb]: p<0,001) dea mbas as variáveis de OM foram maiores nos protocolos em posição neutra. Protocolos autocadenciados apresentaram maior aumento da FC e τ mais rápida (p=0,006 e p=0,046). CONCLUSÃO: O TEC realizado em posição neutra e cadenciamento externo gera maiores repetições e tempo de execução. A dorsiflexão promoveu menor reperfusão muscular e o autocadenciamento, maior e mais rápido aumento da FC.


INTRODUCTION: Different heel-rise test (HRT) protocols have been used, possibly leading to varied responses. It is necessary to analyse the impact of protocol variation on test responses. PURPOSE: To compare the performance, muscle oxygenation (MO), and heart rate (HR) responses of adults in bilateral HRT protocols. METHODS: This was a cross-sectional crossover study. Thirty participants (23.1±2.9 years; 16 men) performed four bilateral HRT protocols with varying cadence (self-cadenced; externally cadenced) and ankle position (neutral; dorsiflexion). For MO responses, we analysed tissue oxygen saturation (StO2) and oxyhemoglobin concentration variation (∆[O2Hb]) and calculated the variation between the smallest and final values (∆Nadir-Final) and the area under the curve (AUC). The variation between the initial and final HR values (∆HR) and the time constant (τ) were calculated. Friedman's test was used to compare the variables among the protocols. Two-way ANOVA was used to identify the impact of cadence and/or ankle position. RESULTS: The number of repetitions and execution time were higher in the neutral position and externally cadenced protocols (p<0.001 for both). ∆Nadir-Final (StO2: p<0.001;∆[O2Hb]: p=0.005) and AUC (StO2: p<0.001; ∆[O2Hb]: p<0.001) of both MO variables were higher in the neutral position protocols. Selfcadenced protocols presented higher HR increase and faster τ (p=0.006 and p=0.046). CONCLUSION: Bilateral HRT performed in a neutral position, and external cadence promotes more repetitions and a longer execution time. Dorsiflexion promotes lower muscle reperfusion, and self-cadence higher and faster HR increase.


Sujets)
Fatigue musculaire , Talon , Performance fonctionnelle physique
2.
Rev. méd. (La Paz) ; 26(1): 38-41, 2020. ilus
Article Dans Espagnol | LILACS | ID: biblio-1127075

Résumé

Objetivo: Describir el valor del índice SaO2/FiO2 en nativos residentes sanos, pacientes con diferentes patologías así como gestantes durante el control prenatal a gran altitud. Material y métodos: Serie de casos llevada a cabo en el Hospital del Norte de la ciudad de Alto, La Paz (Bolivia) localizado a 4 090 metros sobre el nivel del mar, durante el periodo 01 Octubre 2018-31 Enero de 2019. Se incluyeron 119 participantes en quienes se calculó el índice SaO2/FiO2 con respiración a aire ambiente de manera casual, al momento de ingreso o control prenatal de los participantes. Resultados: El promedio del índice SaO2/FiO2 en nativos residentes sanos es de 426, en pacientes no neumópatas 376, neumópatas 312 y gestantes normoevolutivas 423. Existe una correlación negativa alta por r de Pearson entre el desarrollo de la gestación y el índice SaO2/FiO2. Conclusión: El presente estudio ofrece información novedosa acerca de los valores de referencia de SaO2/FiO2 para gran altitud, tanto de nativos residentes "sanos" así como pacientes neumópatas, no neumópatas y gestantes.


Objective. To describe SaO2/FiO2 (oxygen saturation/fraction of inspired oxygen) index in healthy native dwellers, patients with or without chronic lung diseases and pregnant women at high altitude. Material and methods. Case series at Hospital del Norte from El Alto city, La Paz-Bolivia, located at 4090 meters above sea level, during 1 October 2018 to 31 January 2019. 119 participants were included, and SaO2/FiO2 index was measured by using a pulse oximeter. Results. SaO2/FiO2 index average was 426 in healthy dwellers, 376 in patients with non-respiratory pathologies, 312 in patients with pulmonary diseases, and 423 in pregnant women. A high negative correlation (r of Pearson) was observed between pregnancy evolution and SAO2/FIO2 index. Conclusion. This study provides novel data about SaO2/FiO2 index at high altitude either of healthy native dwellers, patients with or without pulmonary diseases and pregnant women.


Sujets)
Capacité d'absorption des radicaux oxygénés
3.
Rev. invest. clín ; 58(1): 28-33, ene.-feb. 2006. ilus, tab
Article Dans Espagnol | LILACS | ID: lil-632333

Résumé

Background. Pulse oximeters are frequently used in the clinical practice and we must known their precision and accuracy. The objective was to evaluate the precision and accuracy of a "pocket" pulse oximeter at an altitude of 2,240 m above sea level. Methods. We tested miniature pulse oximeters (Onyx 9,500, Nonin Finger Pulse Oximeter) in 96 patients sent to the pulmonary laboratory for an arterial blood sample. Patients were tested with 5 pulse oximeters placed in each of the fingers of the hand oposite to that used for the arterial puncture. The gold standard was the oxygen saturation of the arterial blood sample. Results. Blood samples had SaO2 of 87.2 ± 11.0 (between 42.2 and 97.9%). Pulse oximeters had a mean error of 0.28 ± 3.1%. SaO2 - (1.204 x SpO2) - 17.45966 (r = 0.92, p < 0.0001). Intraclass correlation coefficient between each of five pulse oximeters against the arterial blood standard ranged between 0.87 and 0.99. HbCO (2.4 ± 0.6) did not affect the accuracy. Conclusions. The miniature oximeter Nonin is precise and accurate at 2,240 m of altitude. The observed levels of HbCO did not affect the performance of the equipment. The oximeter good performance, small size and low cost enhances its clinical usefulness.


Introducción. Los oxímetros de pulso son ampliamente utilizados en la práctica clínica y su precisión y exactitud deben conocerse especialmente en altitudes moderadas como en la ciudad de México. El objetivo principal fue evaluar la precisión y exactitud de un oxímetro de pulso "de bolsillo" (Onyx 9500 de Nonin®) en la ciudad de México. Métodos. Se realizaron mediciones de la saturación de oxígeno estimada por el oxímetro de pulso (SpO2) y se compararon contra la medida espectrofotométricamente en sangre arterial (SaO2) en 96 pacientes que acudieron al laboratorio de fisiología pulmonar del Instituto Nacional de Enfermedades Respiratorias. A cada paciente se le colocaron cinco oxímetros de pulso en los dedos de una mano obteniéndose un promedio de SpO2 para cada uno de los oxímetros y para los cinco oxímetros a la vez, mediciones que se compararon de manera simultánea contra el estándar. Resultados. Las muestras sanguíneas de los 96 pacientes que participaron tuvieron una SaO2 de 87.2 ± 11.0 (entre 42.2-97.9%). Los oxímetros (promedio de los cinco) tuvieron un error de medición promedio de 0.28 ± 3.1%. SaO2 = (1.204 x SpO2) - 17.45966 (r = 0.92, p < 0.0001). Los coeficientes de correlación intraclase que se obtuvieron al comparar los oxímetros entre sí y contra el estándar (SaO2) estuvieron entre 0.87 y 0.99. El nivel de carboxihemoglobina (HbCO) fue de 2.4 ± 0.6% y no afectó significativamente la exactitud del oxímetro. Conclusiones. El oxímetro digital de pulso "de bolsillo" es preciso y exacto en la estimación de la SaO2 a 2,240 metros de altitud. Los niveles observados de HbCO (2.4%) no afectaron su exactitud. Se observó un adecuado desempeño del oxímetro digital de pulso en la ciudad de México.


Sujets)
Adulte , Sujet âgé , Femelle , Humains , Mâle , Adulte d'âge moyen , Oxymétrie/instrumentation , Oxygène/sang , Altitude , Hypoxie/sang , Hypoxie/diagnostic , Hypoxie/épidémiologie , Carboxyhémoglobine/analyse , Exposition environnementale , Doigts , Hémoglobinométrie/méthodes , Hémoglobines/analyse , Méthémoglobine/analyse , Mexique/épidémiologie , Oxymétrie/économie , Oxyhémoglobines/analyse , Reproductibilité des résultats , Sensibilité et spécificité , Fumée , Spectrophotométrie , Fumer/sang , Fumer/épidémiologie , Pollution par la fumée de tabac , Population urbaine
SÉLECTION CITATIONS
Détails de la recherche