Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 36
Filtre
1.
Acta odontol. latinoam ; 36(3): 177-182, Dec. 2023. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1533524

Résumé

ABSTRACT Current instrumentation systems cannot fully prepare oval root canal systems. This may cause accumulation of hard tissue debris and fail to eliminate bacteria from areas inaccessible to instrumentation, which could perpetuate periapical inflammation and jeopardize the success of endodontic treatment Aim To evaluate the performance of two endodontic systems in oval canals by investigating the changes in volume, unprepared areas, and centering ability of XP-endo Shaper (XPS) and WaveOne Gold (WOG) in oval canals using microcomputed tomography (micro-CT) Materials and Method Thirty mandibular canines were scanned before and after preparation with WOG (25/.07 and 35/.06) or XPS (30/.01) to evaluate the volume, surface area, and canal centralization at 4 mm and 10 mm from the apical foramen Results Volume and surface area increased significantly after preparation with both systems (p<0.05). However, no significant difference was observed in the unprepared areas, regarding either the entire canal (26.21% for WOG and 30.10% for XPS), or the apical segment (18.82% for WOG and 14.63% for XPS) (p >0.05) Conclusions Both systems maintained canal centralization, with no difference between them. XPS and WOG had similar shaping abilities in the mandibular canine, but left almost one third of the unprepared areas.


RESUMO Os sistemas de instrumentação atuais são incapazes de preparar completamente os sistemas de canais radiculares do canal oval, o que pode levar ao acúmulo de detritos de tecido duro e manter micro-organismos em áreas inacessíveis à instrumentação. Essas bactérias poderiam perpetuar a inflamação periapical e comprometer o sucesso do tratamento endodôntico Objetivo Para avaliar o comportamento de dois sistemas endodônticos em canais ovais, esse estudo investigou as alterações no volume, áreas não preparadas e capacidade de centralização do XP-endo Shaper (XPS) e do WaveOne Gold (WOG) em canais ovais usando microtomografia computadorizada (micro-CT) Material e métodos Trinta caninos inferiores foram escaneados antes e depois do preparo com WOG (25/.07 e 35/.06) ou XPS (30/.01) para avaliar o volume, a área de superfície e a centralização do canal a 4 mm e 10 mm do forame apical Resultados O volume e a área de superfície aumentaram significativamente após o preparo com ambos os sistemas (p<0,05). No entanto, não foram observadas diferenças significativas nas áreas não preparadas, não apenas em todo o canal (26,21% para WOG e 30,10% para XPS), mas também no segmento apical (18,82% para WOG e 14,63% para XPS) (p >0,05) Conclusão Ambos os sistemas mantiveram a centralização do canal, sem diferenças entre eles. O XPS e o WOG tiveram habilidades de modelagem semelhantes no canino mandibular, mas deixaram quase um terço das áreas do canal sem preparo.

2.
RFO UPF ; 28(1)20230808. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1511056

Résumé

Introdução: Mesmo com toda evolução tecnológica desses instrumentos, com o desenvolvimento das limas de liga de níquel-titanio (NiTi) e sistemas mecanizados, as fraturas podem ocorrer durante o preparo químico/mecânico. Existem três abordagens mais regulamente aplicadas para solucionar essa intercorrencia: tentativa de remoção do instrumento com ultrassom, tentativa de ultrapassálo (bypass) ou a obturação do segmento. Objetivo: Relatar um caso da técnica de bypass em instrumento fraturado no canal radicular. Descrição do caso: Paciente, sexo feminino, 47 anos, brasileira, sem condições sistêmicas associadas, foi encaminhada à clínica do Curso de Odontologia da UNIFENAS, Divinópolis, Minas Gerais, Brasil, para resolução de fratura de instrumento no canal mésio- vestibular do primeiro molar superior direito (16). Optou-se pelo tratamento pela técnica de bypass, que envolveu as seguintes etapas: anestesia, abertura, utilização de lima C-Pilot #08 para ultrapassar o instrumento fraturado, odontometria, escalonamento regressivo a partir da lima k#20, desinfecção com hipoclorito de sódio 5%, medicação com hidróxido de cálcio por 21 dias, agitação da substância irrigadora e obturação dos canais radiculares. Conclusão: O bypass ao instrumento é uma técnica conservadora, eficaz e uma solução adequada em casos de fratura de limas endodônticas dentro dos canais radiculares. Essa técnica visa preservar o máximo possível da estrutura dental original, evitando procedimentos mais invasivos.(AU)


Introduction: Even with all technological evolution of these instruments, with the development of nickel-titanium alloy (NiTi) files and mechanized systems, fractures can occur during chemical/mechanical preparation. There are three most commonly applie to resolve this complication: attempting to remove the instrument with ultrasound, attempting to bypass it, or obturating the segment. Objective: To report a case of bypass technique in fractured instrument in the root canal. Case description: A 47-year-old female patient from Brazil, with no associated systemic conditions, was referred to the clinic of the Dentistry Course at UNIFENAS, Divinópolis, Minas Gerais, Brazil, for resolution of an instrument fracture in the mesio-vestibular canal of the right upper first molar (16). Treatment was performed using the bypass technique, which involved the following steps: anesthesia, opening, use of a C-Pilot #08 file to bypass the fractured instrument, odontometry, regressive scaling from the k#20 file, disinfection with 5% sodium hypochlorite, medication with calcium hydroxide for 21 days, agitation of the irrigating substance and root canal filling. Conclusion: Instrument bypass is a conservative, effective technique and an adequate solution in cases of endodontic file fracture within root canals. This technique aims to preserve as much of the original tooth structure as possible, avoiding more invasive procedures.(AU)


Sujets)
Humains , Femelle , Adulte d'âge moyen , Traitement de canal radiculaire/instrumentation , Instruments dentaires , Cavité pulpaire de la dent/imagerie diagnostique , Panne d'appareillage , Titane , Radiographie dentaire , Résultat thérapeutique , Nickel
3.
Braz. dent. sci ; 26(2): 1-7, 2023. ilus, tab
Article Dans Anglais | LILACS, BBO | ID: biblio-1436402

Résumé

Objective: The aim of this study was to evaluate the effect of different glide path files on the amount of apically extruded debris. Material and Methods: Sixty single-canaled mandibular premolars were accessed and randomly divided into three groups (n= 20) according to the file used for glid path creation; group A using Traverse file, group B using WaveOne Gold Glider, group C using stainless steel K file. All teeth were then instrumented using the Reciproc system. The debris extruded apically during instrumentation were collected into pre-weighed Eppendorf tubes which were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post instrumentation weights of the Eppendorf tubes. The data were analyzed using one-way ANOVA test, and post hoc analysis. Results: WaveOne Gold Glider produced the least amount of apical extruded debris (0.41±0.25) followed by the Traverse group (0.59±0.20) then the K-file group (0.64±0.16) with a statistically significant difference (p=0.003). Conclusion: Apical extrusion of debris is inevitable during root canal cleaning and shaping. Creation of glide path using engine-driven files produces less amount of apically extruded debris compared to hand-driven K-files. (AU)


Objetivos: O objetivo deste estudo foi avaliar o efeito de diferentes limas glide path na quantidade de detritos extruídos apicalmente. Metodologia: Sessenta pré-molares inferiores com canal único foram acessados e divididos aleatoriamente em três grupos (n= 20) de acordo com a lima utilizada para criação do glid path; grupo A usando lima Traverse, grupo B usando WaveOne Gold Glider, grupo C usando lima K de aço inoxidável. Todos os dentes foram então instrumentados usando o sistema reciprocante. Os detritos extruídos apicalmente durante a instrumentação foram coletados em tubos Eppendorf pré-pesados que foram então armazenados em uma incubadora a 70°C por 5 dias. O peso dos detritos secos extruídos foi estabelecido subtraindo-se os pesos dos tubos Eppendorf antes e após instrumentação. Os dados foram analisados por meio do teste one-way ANOVA e análise post-hoc. Resultados: WaveOne Gold Glider produziu a menor quantidade de detritos apicais extruídos (0,41±0,25) seguido pelo grupo Traverse (0,59±0,20) e depois pelo grupo K-file (0,64±0,16) com uma diferença estatisticamente significativa (p=0,003). Conclusão: A extrusão apical de detritos é inevitável durante a limpeza e modelagem do canal radicular. A criação do glide path usando limas acionadas por motores produz menos quantidade de detritos extruídos apicalmente em comparação com as limas K manuais. (AU)


Sujets)
Instruments dentaires , Cavité pulpaire de la dent
4.
Rio de Janeiro; s.n; 2022. 95 p.
Thèse Dans Portugais | LILACS, BBO | ID: biblio-1554296

Résumé

O conceito de Endodontia Minimamente Invasiva é amplo, e envolve não só a realização de acessos, mas também o uso de instrumentos com conicidades reduzidas ou geometrias inovadoras. Buscando avaliar se as estratégias minimamente invasivas adotadas apresentam vantagens frente aos tratamentos tradicionais, a presente tese foi dividida em três estudos. O estudo 1 avaliou a preservação da dentina perirradicular e o alargamento da porção apical dos canais de molares inferiores com instrumentos TruNatomy e ProTaper Gold. Para isso, vinte molares inferiores foram microtomografados, pareados e distribuídos em 2 grupos. No grupo ProTaper Gold, os canais mesial e distal foram preparados até os instrumentos F2 e F3, respectivamente, enquanto no grupo TruNatomy, os canais mesial e distal foram ampliados até os instrumentos prime e medium, respectivamente. Após um novo escaneamento, os parâmetros de instrumentação foram calculados. Os dados foram analisados pelos testes de Mann-Whitney, T Student e escalonamento multidimensional não-métrico. Não foram encontradas diferenças entre os grupos em relação à área não preparada e redução de espessura de dentina. O grupo ProTaper Gold removeu mais dentina que o TruNatomy no terço coronal das raízes mesiais. O estudo 2 avaliou a formação de microtrincas dentinárias em molares inferiores acessados de forma ultraconservadora (UltraAC), instrumentados com Reciproc e XP-Endo Shaper. Quarenta molares inferiores foram microtomografados, pareados e distribuídos em 4 grupos de acordo com o tipo de cavidade de acesso e protocolo do sistema de instrumentação: tradicional/Reciproc; tradicional/XP-endo Shaper; UltraAC/Reciproc e UltraAC/XP-endo Shaper. Após os preparos dos canais, os dentes foram escaneados novamente e as imagens transversais das raízes mesiais e distais, do nível da furca ao ápice foram avaliadas com o objetivo de identificar a presença de microtrincas dentinárias. Em todos os grupos, as microtrincas verificadas nas imagens pós-operatórias já estavam presentes no exame pré-operatório. O estudo 3 avaliou a influência de instrumentos com o mesmo diâmetro de ponta e diferentes conicidades no percentual de área não preparada e volume de dentina removida após o preparo dos canais mesiovestibular e distovestibular de molares superiores com ou sem o canal mesiovestibular 2 (MV2). Vinte e dois molares superiores foram selecionados, microtomografados, pareados e classificados em dois grupos, de acordo com a anatomia das raízes: dentes com MV2 e dentes sem MV2. Após o acesso, os canais radiculares foram preparados com instrumentos 25/.01, 25/.03, 25/.05, 25/.06 e 25/.08v. Os dentes foram submetidos a novos escaneamentos por micro-CT após preparo com cada instrumento descrito anteriormente. Os dados foram analisados usando o Modelo linear generalizado misto e aproximação de Kenward-Roger para testes Wald F. Em dentes com e sem canais MV2, a porcentagem de área não preparada apresentou uma diminuição significativa ao longo do tratamento após cada instrumento utilizado e a porcentagem de dentina removida apresentou um aumento significativo ao longo do tratamento. Com base nos estudos, concluiu-se que as estratégias minimamente invasivas adotadas não apresentaram vantagens frente aos tratamentos tradicionais(AU)


The concept of Minimally Invasive Endodontics is broad, and involves not only the realization of accesses, but also the use of instruments with reduced tapers or innovative geometries. Seeking to assess whether the minimally invasive strategies adopted have advantages over traditional treatments, this thesis was divided into three studies. Study 1 evaluated the preservation of periradicular dentin and enlargement of the apical portion of the mandibular molar canals prepared with TruNatomy and ProTaper Gold instruments. For this, twenty lower molars were microtomography, paired and divided into 2 groups. In the ProTaper Gold group, the mesial and distal canals were prepared up to the F2 and F3 instruments, respectively, while in the TruNatomy group, the mesial and distal canals were prepared up to the prime and medium instruments, respectively. After a new scan, the instrumentation parameters were calculated. Data were analyzed by Mann-Whitney, T Student and non-metric multidimensional scaling tests. No differences were found between groups regarding unprepared area and dentin thickness reduction. The ProTaper Gold group removed more dentin than TruNatomy in the coronal third of the mesial roots. Study 2 evaluated the formation of dentinal microcracks in mandibular molars accessed by ultraconservative cavites (UltraAC), instrumented with Reciproc and XP-Endo Shaper. Forty lower molars were microtomography, paired and divided into 4 groups according to the type of access cavity and instrumentation system protocol: traditional/Reciproc; traditional/XP-endo Shaper; UltraAC/Reciproc and UltraAC/XP-endo Shaper. After the root canal preparations, the teeth were scanned again and the transverse images of the mesial and distal roots, from the furcation level to the apex, were evaluated in order to identify the presence of dentinal microcracks. In all groups, the microcracks seen in the postoperative images were already present in the preoperative examination. Study 3 evaluated the influence of instruments with the same tip diameter and different tapers on the percentage of unprepared area and volume of dentin removed after preparation of the mesiobuccal and distobuccal canals of maxillary molars with or without the mesiobuccal canal 2 (MV2). Twenty-two maxillary molars were selected, microtomography, paired and classified into two groups, according to root anatomy: teeth with MV2 and teeth without MV2. After access, the root canals were prepared with instruments 25/.01, 25/.03, 25/.05, 25/.06 and 25/.08v. The teeth were rescanned by micro-CT after preparation with each instrument described above. Data were analyzed using the Generalized Linear Mixed Model and Kenward-Roger approximation for Wald F tests. In teeth with and without MV2 canals, the percentage of unprepared area showed a significant decrease throughout the treatment after each instrument used and the percentage of removed dentin showed a significant increase during treatment. Based on the studies, it was concluded that the minimally invasive strategies adopted did not present advantages over traditional treatments(AU)


Sujets)
Humains , Mâle , Préparation de canal radiculaire/méthodes , Microtomographie aux rayons X , Molaire/imagerie diagnostique , Préparation de canal radiculaire/instrumentation , Cavité pulpaire de la dent
5.
Braz. dent. sci ; 25(4): 1-15, 2022. tab, ilus, graf
Article Dans Anglais | BBO, LILACS | ID: biblio-1400807

Résumé

Objective: The purpose of this systematic review with bibliometric analysis was to map the available scientific evidence on intentional foraminal enlargement (IFE) and explore publication trends. Methods: This review is in accordance with the PRISMA 2020 Statement and is registered on the Open Science Framework. Two independent reviewers carried out a comprehensive search of seven databases (PubMed/MEDLINE, Cochrane Library, Scopus, Embase, Web of Science, LILACS, and BBO) up to January 31 st, 2022. Studies that investigated IFE were considered eligible, and the data were analyzed using the VOSViewer software. Results:The search identified a total of 55 IFE-related articles from 10 countries and 25 journals, with an increasing trend for publications over the last decade. The majority of evidence was based on laboratory assays (65.4%), followed by randomized clinical trials (18.1%) with follow-up periods of up to 2 months. The main clinical outcome evaluated was post-operative pain. The highest number of studies were carried out by the State University of Campinas, and published in the Journal of Endodontics. Also, studies with the highest level of evidence found that IFE resulted in greater post-operative pain in the initial days post-treatment. Conclusion:This systematic review with bibliometric analysis mapped the scientific progress and publication trends in the field of IFE, thus shedding light on gaps in the literature with the aim of guiding researchers to conduct more high-impact investigations by performing clinical studies evaluating rates of periapical repair and IFE treatment success using long-term observation periods (AU)


Objetivo: O objetivo desta revisão sistemática com análise bibliométrica foi mapear as evidências científicas disponíveis sobre ampliação foraminal intencional (IFE) e explorar as tendências de publicação. Métodos: Esta revisão está de acordo com a declaração PRISMA 2020 e está registrada no Open Science Framework. Dois revisores independentes realizaram uma busca abrangente em sete bases de dados (PubMed/MEDLINE, Cochrane Library, Scopus, Embase, Web of Science, LILACS e BBO) até 31 de janeiro de 2022. Os estudos que investigaram IFE foram considerados elegíveis e os dados foram analisados usando o software VOSViewer. Resultados: A busca identificou um total de 55 artigos relacionados ao IFE provenientes de 10 países e 25 periódicos, com tendência crescente de publicações na última década. A maioria das evidências foi baseada em ensaios laboratoriais (65,4%), seguido de ensaios clínicos randomizados (18,1%) com períodos de follow-up de até 2 meses. O principal desfecho clínico avaliado foi a dor pós-operatória. O maior número de estudos foi realizado pela Universidade Estadual de Campinas e publicado no Journal of Endodontics. Estudos com os maiores níveis de evidência constataram que IFE resultou em maior dor pós-operatória nos primeiros dias pós- tratamento. Conclusão: Esta revisão sistemática com análise bibliométrica mapeou o progresso científico e as tendências de publicação na área de IFE, lançando luz sobre lacunas na literatura com o objetivo de orientar pesquisadores a realizar investigações de maior impacto, realizando estudos clínicos avaliando taxas de reparo periapical e sucesso do tratamento usando essa técnica e com acompanhamento à longo prazo. (AU)


Sujets)
Bibliométrie , Préparation de canal radiculaire , Endodontie , Revue systématique
6.
Rio de Janeiro; s.n; 2021. 77 p.
Thèse Dans Portugais | BBO, LILACS | ID: biblio-1525808

Résumé

As cavidades de acesso dominaram a recente discussão sobre a Endodontia minimamente invasiva (EMI). No entanto, a rotulagem da EMI é mais ampla, envolvendo o uso de instrumentos com conicidades reduzidas ou geometrias inovadoras que permitam a remoção mínima de dentina. Além disso, aprimoramentos metodológicos têm sido sugeridos para mimetizar condições clínicas. Buscando responder algumas questões acerca da EMI, a presente tese é dividida em dois estudos. O estudo 1 avaliou a influência do acesso ultraconservador (UltraAC) na instrumentação, na qualidade da obturação e na capacidade máxima de carga para fratura em molares inferiores após o preparo do canal com o sistema XP-endo Shaper (XP) ou Reciproc (RC) em condições clínicas simuladas. Para isso, quarenta molares inferiores foram microtomografados e pareados em quatro grupos (n = 10), de acordo com o acesso e a instrumentação: TradAC/RC, TradAC/XP, UltraAC/RC e UltraAC/XP. Os dentes foram reescaneados e os parâmetros da instrumentação e obturação foram analisados. Os dentes foram restaurados e submetidos à ciclagem termomecânica e à capacidade máxima de carga para a fratura. O teste ANOVA foi usado para a análise estatística (P < 0,05). Os grupos TradAC apresentaram menor porcentagem (%) de área não preparada do que os grupos UltraAC (P < 0,05). O grupo UltraAC/XP apresentou a menor % de dentina removida (P < 0,05). A % de debris foi menor nos grupos UltraAC/XP e TradAC/XP do que no UltraAC/RC e TradAC/RC (P < 0,05). Os grupos UltraAC demonstraram maior % de espaços vazios e de material obturador na câmara pulpar (P < 0,05). Não houve diferença na capacidade máxima de carga para a fratura entre os grupos (P > 0,05). O estudo 2 avaliou o uso de instrumentos com conicidade reduzida - Bassi Logic ,03 (BL), com diferentes designs (XP) e como grupo de comparação o sistem Reciproc, na eficácia da instrumentação dos canais em condições clínicas simuladas. Vinte e quatro molares foram microtomografados, acessados de forma tradicional e divididos em três grupos (n = 8), de acordo com o preparo: BL, XP e RC. Nos grupos BL e RC, os canais mesiais foram instrumentados com 25/,03 ou R25 e o canal distal com 25/,03 e 40/,03 ou R25 e R40, respectivamente. No grupo XP, o mesmo instrumento foi utilizado em todos os canais (30/,04). Após o preparo, os dentes foram reescaneados e a % de área não preparada e de dentina removida foram avaliadas separadamente para os canais mesiais e distal. Os dados foram analisados com os testes ANOVA e de Tukey (P < 0,05). Verificou-se que o grupo BL apresentou maior % de área não preparada para ambos os canais em relação aos grupos XP e RC (P < 0,05). No entanto, não houve diferença na % de dentina removida entre os grupos (P > 0,05). Com base nos estudos, conclui-se que as estratégias minimamente invasivas adotadas no acesso e na instrumentação foram desvantajosas frente a tratamentos tradicionais, não justificando o seu uso(AU)


Access cavities have dominated the recent discussion on minimally invasive Endodontics (EMI). However, the issue of MIE is broader than access cavities, such as the use of instruments with reduced taper or innovative geometries that allow minimal dentin removal. Furthermore, methodological improvements have been suggested to mimic clinical conditions. Seeking to answer some questions about EMI, this thesis is divided into two studies. The first study evaluated the influence of ultraconservative access (UltraAC) on canal shaping, filling ability and maximum load capacity for fracture of mandibular molars after root canal preparation with XP-endo Shaper (XP) or Reciproc (RC), under simulated clinical conditions. Thus, forty mandibular molars were scanned and paired into four groups (n = 10), according to access and instrumentation protocol: TradAC/RC, TradAC/XP, UltraAC/RC and UltraAC/XP. Teeth were rescanned and the instrumentation and filling parameters were analyzed. The teeth were restored and submitted to thermomechanical cycling and maximum load capacity for the fracture. ANOVA test was used for statistical analysis (P < 0.05). The TradAC groups had a lower percentage (%) of unprepared area than the UltraAC groups (P < 0.05). The UltraAC/XP group had the lowest % of dentin removed (P < 0.05). The % of debris was lower in the UltraAC/XP and TradAC/XP groups than in the UltraAC/RC and TradAC/RC groups (P < 0.05). The highest % of voids and filling material in the pulp chamber was observed in the UltraAC groups (P < 0.05). There was no difference in the maximum load capacity for the fracture between the groups (P > 0.05). The second study evaluated the use of a reduced taper endodontic instrument system - Bassi Logic .03 taper (BL), expandable heat-treated system (XP) and, as comparison, the Reciproc system, on the ability to shape canals under simulated clinical conditions. For that, twenty-four mandibular molars were scanned and divided into three groups (n = 8), according to root canal instrumentation system: BL, XP and RC. In the BL and RC groups, the mesial canals were instrumented with 25/.03 or R25 and the distal canal with 25/.03 and 40/.03 or R25 and R40, respectively. In the XP group, the same instrument was used in all root canals (30/.04). After preparation, the teeth were rescanned and the % of unprepared area and dentin removed were evaluated separately for the mesial and distal canals. Data were analyzed using ANOVA and Tukey tests (P < 0.05). It was found that the BL group had a higher % of unprepared area for both root canals compared to the XP and RC groups (P < 0.05). However, there was no difference in the % of dentin removed between groups (P > 0.05). Based on the studies, it is concluded that there is no justification for the use of EMI since in general, UltraAC did not promote advantages over TradAC and the use of instruments with reduced taper resulted in a larger unprepared area, which could possibly influence the cleaning of the root canal system (AU)


Sujets)
Humains , Mâle , Femelle , Interventions chirurgicales mini-invasives , Préparation de canal radiculaire/instrumentation , Préparation de canal radiculaire/méthodes , Résistance à la flexion , Microtomographie aux rayons X , Molaire
7.
Acta odontol. latinoam ; 34(3): 282-288, 2021. graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1383415

Résumé

ABSTRACT This study compared the shaping ability of single-file reciprocating (WaveOne Gold) and multifile rotary (Mtwo) systems on mandibular oval-shaped canine root canals, using microcomputed tomography (micro-CT). Thirty mandibular canines were scanned by micro-CT and assigned to one of two groups (n=15) according to the system used for root canal preparation: WaveOne Gold or Mtwo. After preparation, the teeth were rescanned, and the percentage of untouched canal area, apical transportation and centering ability were analyzed. The data was evaluated using Kruskal and Mann- Whitney tests (p<0.05). No difference was found in percentage of unprepared canal area between groups in the entire root canal or the apical third, or in centering ability (p>0.05). WaveOne gold had less canal transportation than MTwo at the 5 mm section (p<0.05). WOG and Mtwo systems presented similar shaping ability and centering ability in oval-shaped canals. However, WOG presented less transportation than Mtwo at 5 mm from the apex.


RESUMO Este estudo comparou a capacidade de modelagem dos sistemas reciprocante de lima única (WaveOne Gold) e rotatórios com múltiplas limas (Mtwo) em caninos ovais inferiores, usando microtomografia computadorizada (micro-CT). Trinta caninos inferiores foram escaneados por micro-CT e divididos em dois grupos (n = 15) de acordo com o sistema usado durante o preparo do canal radicular: WaveOne Gold (WOG) e Mtwo. Os dentes foram reeescaneados e a porcentagem de área do canal não preparada, transporte apical e capacidade de centralização foram analisados. Os dados foram avaliados pelos testes de Kruskal Wallis e Mann-Whitney (p<0,05). Nenhuma diferença foi encontrada na porcentagem de área não preparada entre os grupos em todo o canal radicular e no terço apical e na capacidade de centralização (p>0,05). O sistema WOG promoveu menor transporte do canal do que o sistema Mtwo na região de 5mm aquém do ápice (p<0,05). Os sistemas WOG e Mtwo apresentaram capacidade de modelagem e capacidade de centralização semelhantes em canais ovais. No entanto, WOG promoveu menor transporte do que Mtwo a 5 mm do ápice.

8.
Dent. press endod ; 9(3): 37-43, Sept-Dec.2019. Tab, Ilus
Article Dans Anglais | LILACS | ID: biblio-1343659

Résumé

Introdução: o sistema reciprocante pode preparar o canal radicular usando um único instrumento; entretanto, para garantir o sucesso endodôntico, a obturação radicular deve ser de alta qualidade. Para isso, várias técnicas podem ser usadas, e é importante que sua eficiência seja determinada. Assim, o presente estudo analisou três técnicas diferentes, considerando a capacidade de preenchimento da obturação do canal radicular. Métodos: o estudo envolveu 30 molares inferiores humanos extraídos; os canais mesiais desses dentes foram instrumentados com o sistema WaveOne e, então, divididos em três grupos, de acordo com a técnica utilizada para o preenchimento do canal radicular. A técnica de cone único, técnica híbrida de Tagger e uma técnica experimental (cone único mais o uso do condensador guta-percha) foram utilizadas para os Grupos I, II e II, respectivamente. Os dentes obturados foram cortados transversalmente em seções de 0,3 mm a 2, 4 e 6 mm do ápice do canal radicular. As seções foram, então, digitalizadas e analisadas. Os dados foram comparados estatisticamente pelos testes de Kruskal-Wallis e Dunn, com valores de p < 0,05 indicando significância. Resultados: não houve diferença significativa entre os grupos experimentais em relação às quantidades de guta-percha ou cimento utilizado. No entanto, nos Grupos II e III, houve menor ocorrência de espaços vazios no preenchimento do canal radicular do que no Grupo I (p < 0,05). Conclusão: conclui-se que as técnicas de preenchimento do canal radicular apresentadas no presente estudo geraram um baixo número de espaços vazios e que as técnicas termoplastificadoras conferem menos espaços vazios (AU).


ntroduction: Reciprocating system can prepare the root canal using only one instrument. However, to ensure successful endodontic treatment, it must result in high-quality root canal filling. In this regard, several techniques can be used, and it is important that their efficiency is determined. This study analyzed three different techniques in terms of their ability to fill root canal. Material and Methods: The study involved 30 extracted human mandibular molars. Mesial canals of these teeth were instrumented using WaveOne system and then divided into three groups according to the technique used for root canal filling. The single-cone technique, Tagger's hybrid technique, and an experimental technique (single-cone plus gutta-percha condenser) were used for Groups I, II, and II, respectively. Filled teeth were sectioned transversely into 0.3-mm sections 2, 4, and 6 mm from the root canal apex. The sections were then digitized and analyzed. Data were statistically compared using Kruskal-Wallis and Dunn tests, with p-values <0.05 indicating significance. Results: There was no significant difference among experimental groups in terms of the amount of gutta-percha or sealer used. However, in Groups II and III, there were fewer voids in root canal filling than in Group I (p < 0.05). Conclusion: The techniques for root canal filling presented in the current study yielded a low number of empty spaces, and thermoplastification techniques result infewer voids (AU).


Sujets)
Humains , Produits d'obturation des canaux radiculaires , Obturation de canal radiculaire , Techniques in vitro , Traitement de canal radiculaire , Cavité pulpaire de la dent , Molaire
9.
RFO UPF ; 24(3): 334-339, 2019. ilus, tab
Article Dans Anglais | LILACS, BBO | ID: biblio-1357639

Résumé

Objective: To assess the apical transportation in simulated root canals with different curvature angles prepared using manual instrumentation and rotary and reciprocating motions. Methods: Sixty simulated root canals were prepared using manual instrumentation (Flexofile K-file) (MT), continuous rotation (HyFlex CM) (HF), and reciprocating motion (WaveOne Gold) (WG). A trained operator prepared the canals, and the apical enlargement was standardized up to a #25 file in all systems tested. Two different curvature angles of the simulated root canals were tested: 70° and 50°. Overlapping photographs of the simulated root canals, before and after root canal preparation, were used to measure the apical transportation (mm), using the ImageJ software. Descriptive statistics (mean and standard deviation) were analyzed and the groups were compared with two-way ANOVA followed by Tukey's post-hoc, with α=5%. Results: There was a statistically significant interaction between the effects of group and angle in the apical transportation (F = 3.740; p = 0.031). Simple main effects analysis showed that HyFlex CM produced a significantly lower apical transportation when compared to WaveOne Gold (p = 0.02) and the manual technique (p < 0.01), regardless of the angle. However, there were no differences between WaveOne Gold and manual technique in canals with the 70° angle (p>0.05). The group with the highest mean apical transportation was the MT, with 0.0917 mm, followed by WG and HF, with 0.0633 and 0.0325, respectively. Conclusion: Simulated root canals prepared with rotary motion (HyFlex CM) showed the lowest apical transportation, followed by the reciprocating motion (WaveOne Gold). The manual technique showed the most unfavorable results, with the highest apical transportation.(AU)


Objetivo: avaliar o transporte apical em canais radiculares simulados com diferentes ângulos de curvatura preparados por meio de instrumentação manual e dos movimentos rotativo e reciprocante. Métodos: sessenta canais simulados foram preparados usando instrumentação manual (Flexofile K- -file) (MT), rotação contínua (HyFlex CM) (HF) e movimento reciprocante (WaveOne Gold) (WG). O preparo do canal radicular foi realizado por um operador treinado, e o alargamento apical foi padronizado até o instrumento #25 em todos os sistemas testados. Dois diferentes ângulos de curvatura dos canais simulados foram testados: 70° e 50°. Fotografias sobrepostas dos canais simulados, antes e após o preparo do canal radicular, foram utilizadas para medir o transporte apical (mm), utilizando o software ImageJ. Estatísticas descritivas (média e desvio padrão) foram analisadas e as comparações entre os grupos foram realizadas através de ANOVA de duas vias, seguido por post-hoc de Tukey, com α=5%. Resultados: houve interação estatisticamente significativa entre os efeitos do grupo e do ângulo no transporte apical (F = 3,740; p = 0,031). A análise simples dos efeitos principais mostrou que o sistema Hy- Flex CM produziu um transporte apical significativamente menor quando comparado ao sistema WaveOne Gold (p = 0,02) e à Técnica Manual (p <0,01), independentemente do ângulo. No entanto, não houve diferenças entre o WaveOne Gold e a Técnica Manual em canais com ângulo de 70 ° (p> 0,05). O grupo que apresentou maior transporte apical médio foi o MT, com 0,0917 mm, seguido pelo WG e pela HF, com 0,0633 e 0,0325, respectivamente. Conclusão: canais radiculares simulados preparados com movimento rotatório (HyFlex CM) mostraram o menor transporte apical, seguido de movimento reciprocante (WaveOne Gold). A técnica manual revelou os resultados mais desfavoráveis, com maior transporte apical.(AU)


Sujets)
Préparation de canal radiculaire/instrumentation , Apex de la racine de la dent/anatomie et histologie , Instruments dentaires , Répartition aléatoire , Reproductibilité des résultats , Analyse de variance , Conception d'appareillage
10.
ROBRAC ; 26(79): 32-36, out./dez. 2017. graf, ilus
Article Dans Portugais | LILACS | ID: biblio-906008

Résumé

Objetivo: Instrumentos endodônticos de movimentos reciprocante estão entre as últimas inovações para o preparo do sistema de canais radiculares. O objetivo desse estudo piloto foi comparar o desvio apical promovido por sistemas reciprocantes e rotatório em canais simulados. Material e método: Quarenta e cinco canais simulados foram distribuídos aleatoriamente em três grupos experimentais (n=15), de acordo com o sistema utilizado para realização do preparo: Grupo PT - sistema ProTaper; Grupo RP - sistema Reciproc e Grupo WO - sistema WaveOne. O desvio apical foi avaliado por meio da análise de imagens obtidas pré e pós-instrumentação de cada canal simulado, com auxílio do programa ImageJ. Resultados: Todos os grupos apresentaram algum nível de desvio apical. O grupo PT apresentou maior desvio aos 2 mm, com diferença estatisticamente significante em relação aos demais grupos (p<0,05). Quando comparada a média dos 3 mm apicais, somente houve diferença significativa entre os grupos PT e RP (p<0,05). Conclusão: Nenhum dos sistemas testados, reciprocante ou rotatório, foi capaz de manter a posição original do forame apical após o preparo do canal simulado.


Objective: Endodontic instruments of reciprocating motion are among the latest innovations for root canal system preparation. The aim of this pilot study was to compare the apical deviation promoted by reciprocating and rotary systems in simulated canals. Methods: Forty-five simulated canals were randomly distributed into three experimental groups (n=15), according to the system used for preparation: PT group - ProTaper system; RP group - Reciproc and WO group - WaveOne system. The apical deviation was assessed by analysis of pre- and post-instrumentation images of each simulated canal, with the aid of the ImageJ software. Results: All groups presented some level of apical deviation. The PT group presented greater deviation at 2 mm, with statistically significant difference in comparison with the other groups (p<0.05). When compared the average of the final apical 3 mm, there was significant difference only between PT and RP groups (p<0.05). Conclusion: None of the tested systems, reciprocating or rotary, were able to maintain the original position of the apical foramen after preparation of the simulated canal.

11.
ROBRAC ; 26(77): 43-46, abr./jun. 2017.
Article Dans Portugais | LILACS-Express | LILACS | ID: biblio-875297

Résumé

Objetivo: Avaliar a precisão do exame de Tomografia Computadorizada de Feixe Cônico (TCFC) na determinação do comprimento de trabalho (CT) em 24 dentes humanos unirradiculares. Material e Método: Após a realização dos procedimentos de abertura coronária, exploração do canal radicular e preparo dos terços cervical e médio os dentes tiveram seus comprimentos de trabalho determinados pelos métodos direto, eletrônico e tomográfico. No método direto, o CT foi determinado visualmente com o auxílio de uma lima do tipo K-File #20, enquanto que nos métodos eletrônico e tomográfico, as odontometrias foram estabelecidas, respectivamente, com a utilização de um localizador eletrônico foraminal da marca Root ZX II e em imagens de TCFC obtidas em um tomógrafo Prexion 3D. Os dados foram analisados por meio do teste ANOVA ao nível de 5% de significância Resultados: Ao todo foram realizadas 72 mensurações. Não foram observadas diferenças estatisticamente significantes entre as medidas obtidas pelos diferentes métodos empregados. Conclusões: O exame de TCFC revelou ser uma alternativa eficaz para a obtenção do CT durante a terapia endodôntica.


Aim: To evaluate the accuracy of Cone Beam Computed Tomography (CBCT) in work length (WL) determination in twentyfour single-rooted human Material and Methods: After performing the procedures of coronary opening, root canal exploration and cervical preflaring, the teeth had their work lengths determined by direct, electronic and tomographic methods. In the direct method, the WL was determined visually, using a #20 KFile instrument. In the electronic and tomographic methods, the WLs were determined using the Root ZX II locating device and TCFC images, respectively. The data were analyzed statistically by the ANOVA test at 5% significance level. Results: A total of 72 measurements were performed. No statistical difference was observed between the measurements obtained by the different methods. Conclusions: The CBCT proved to be an effective alternative for WL determination during root canal treatment.

12.
ROBRAC ; 23(65)jul 2014. tab, graf
Article Dans Portugais | LILACS | ID: lil-763972

Résumé

A introdução da técnica de instrumentação rotatória com instrumentos de níquel-titânio (NiTi) diminuiu o número de erros operatórios e aumentou a qualidade dos tratamentos endodôntico. Contudo, poucos trabalhos, no Brasil e no mundo, mostram a difusão do uso de técnicas rotatórias entre os profissionais que realizam endodontia. O presente estudo tem como objetivo analisar o grau de implementação do preparo de canais radiculares com sistemas rotatórios de NiTi na endodontia no Brasil. Para a coleta de dados, foi desenvolvido um questionário on-line autoaplicável composto por 16 questões, enviado para 250 endereços eletrônicos. Das 108 respostas obtidas, os dados analisados nos permitiram observar que 71% eram especialistas em endodontia e 26% estavam cursando a pós-graduação; 88% utilizavam instrumentação mecanizada e, desses, 55% combinavam a rotação contínua com a alternada e, 41% faziam usoapenas da rotação contínua. O risco de fratura e custo operacionalforam os principais motivos abordados para a não implementação dos sistemas rotatórios de NiTi em endodontia.


The use of NiTi rotary instruments in Endodontics increased the quality of endodontic treatments and reduced the number of errors during root canal preparation. There are few papers in Brazil and around the world analyzing the diffusion of this new technology. The aim of this study involving Brazilian dentists was analyzed the accept of the new technologic in Endodontics. The increased purchasing of this new technology does not necessarily lead to correct use and incorporation into practice. A questionnaire survey comprising 16 questions was sent to 250 students and endodontics?s e-mails. The sampling frame was 108, comprising 71% specialists and 26% postgraduate students. Rotary instruments were used by 88%, 55% of them used rotary and alternatedrotation system and 41% only rotary instrumentation. Fracture and the high cost of the instruments were the main reasons for not using rotary NiTi in endodontics.

13.
Rev. odontol. UNESP (Online) ; 43(2): 111-118, Mar-Apr/2014. tab, ilus
Article Dans Portugais | LILACS, BBO | ID: lil-710375

Résumé

Introdução: Os tratamentos endodônticos têm evoluído com a finalidade de preparar o sistema de canais radiculares para receber uma obturação hermética deste sistema e assim preservar a saúde dos tecidos periapicais e/ou restabelecê-la, quando acometidos por lesões. Tais metas são alcançadas mediante obediência de uma adequada preparação químico-mecânica dos canais radiculares, seguida da obturação dos mesmos. Objetivo: Analisar o preparo químico-mecânico dos canais radiculares realizado in vitro pelos alunos do Curso de Odontologia da Universidade Federal do Espírito Santo, utilizando-se da diafanização. Material e método: Foram utilizados 88 espécimes dentários (caninos inferiores), cujo preparo químico-mecânico in vitro foi realizado pelos alunos. Esses dentes foram radiografados e posteriormente submetidos à técnica de diafanização. Nestes, se analisou a qualidade das técnicas de preparo químico-mecânico quanto à modelagem do canal radicular e, comparativamente, o melhor resultado das mesmas; visualizaram-se as características anatômicas do sistema de canais radiculares, e compararam-se o exame radiográfico e a diafanização dos dentes. Resultado: Quanto à modelagem dos canais radiculares analisados pela técnica da diafanização, 67% foram modelados com significância estatística de 0,002 (p<0,05) e, quanto à concordância dos resultados da variável modelagem do canal, entre o exame radiográfico e a técnica da diafanização, obteve-se um valor Kappa=0,511, mostrando uma concordância moderada entre as duas técnicas de visualização. Conclusão: A radiografia revelou-se limitada na visualização da modelagem dos canais ...


Introduction: The endodontic treatments have evolved in order to prepare the root canal system to receive a hermetic filling of the system and preserve the health of periapical and/or restore it when affected by tissue injury. These are achieved through obedience the a suitable chemical-mechanical preparation, then the filling of the same. Objective: Analyze the chemo-mechanical preparation of root canals performed in vitro by students of Dentistry of the Federal University of Espírito Santo, using the clearing technique. Material and method: 88 dental specimens (lower canines) were used, and provided to students who performed in vitro preparation chemo-mechanical. These specimens were radiographed and subsequently submitted to leaf clearing technique. The quality of the preparation chemical-mechanical techniques was examined concern the shaping of the root canal and compared the best result of the same, visualized the anatomical features of the root canal system, compared the radiographic exam of the teeth and clearing technique. Result: the modeling of root canals analyzed by the clearing technique, 67% were modeled with a statistical significance of 0.002 (p<0.05) and as the concordance of the results of variable modeling of the root canals between the radiographic examination and clearing technique yielded a Kappa value=0.511 showing a moderate agreement between the two visualization techniques. Conclusion: The radiography proved to be limited in view of the channel modeling and also in view of the anatomical features of the root canal system, and also that the clearing technique is a visualization technique accessible and essential to the evolution of education in Endodontics. .


Sujets)
Obturation de canal radiculaire , Étudiant dentisterie , Techniques in vitro , Radiographie dentaire , Préparation de canal radiculaire , Endodontie
14.
ROBRAC ; 22(63)out.-dez. 2013. tab, ilus
Article Dans Portugais | LILACS | ID: lil-737225

Résumé

Objetivo: Comparou o tempo de preparo, ocorrência de fratura e manutenção do trajeto do canal em canais artificiais do instrumento Reciproc R25 em movimento reciprocante e rotação contínua anti-horária. Material e Métodos: Foram utilizados dois grupos contendo 10 canais artificiais em blocos de acrílico cada, sendo um o grupo controle, instrumentado com movimento reciprocante, e o grupo teste utilizando rotação contínua anti-horária a 300rpm para a instrumentação. Resultados: os resultados mostraram que houve diferença estatística significante em relação ao tempo de preparo entre os grupos, uma vez que a rotação contínua anti-horária proporcionou um menor tempo de preparo; ambos mantiveram o trajeto original do canal sem qualquer desvios no terço apical e ocorreu uma fratura no grupo da rotação contínua. Conclusão: o sistema Reciproc manteve a trajetória original do canal, não influenciou na incidência de fratura dos instrumentos e demandou menor tempo de preparo utilizando rotação contínua. Portanto, o sistema Reciproc pode ser utilizado com rotação contínua anti-horária desde que velocidade, torque e pressão apical sejam respeitados e se empregue os instrumento uma única vez.


Objective: This study aimed to compare the preparation time, occurrence of fracture and maintenance of the canal path in artificial canals using Reciproc R25 instrument moving reciprocating and continuous counterclockwise rotation. Methods: Two groups of 10 Simulated rootcanals, each one in an artificial acrylic block, was instrumented with reciprocating motion (control group) and using counterclockwise continuous rotation to 300rpm (test group). Results: The results showed statistically significant difference in relation to the preparation time between the groups, since the counterclockwise continuous rotation allowed shorter preparation time, both kinematics kept the original route of the canal without any deviations in the apical third. A fracture occurred in the group of continuous rotation. Conclusion: The Reciproc system kept the original trajectory of the canals and did not influence the incidence of instruments fracture. A less preparation time was required when the continuous rotation was used. Therefore, the Reciproc system can be used with counterclockwise continuous rotation since that speed, torque and apical pressure are respected. The instrument also should be employed just one time.

15.
Rio de Janeiro; s.n; 2013. 93 p.
Thèse Dans Portugais | LILACS, BBO | ID: biblio-1451883

Résumé

O objetivo do presente trabalho foi avaliar, em microtomografia computadorizada (µCT), o preparo de canais de molares inferiores com diferentes sistemas acionados a motor. Foram selecionadas 58 raízes mesiais patentes, de diâmetro anatômico correspondente a #10. Para a avaliação em µTC, um anel de aço inoxidável foi confeccionado nos moldes do suporte para amostra do microtomógrafo, para que servisse de fôrma para a inclusão das raízes em resina Duralay, a fim de padronizar a posição do espécime no escaneamento inicial e final. Os canais foram preparados com os sistemas Reciproc R25 (n=16); WaveOne Primary File (n=16); Twisted File (n=14), e HyFlex (n=12). Após serem escaneados, foram reconstruídos tridimensionalmente e avaliados quantitativamente quanto à variação de volume (mm3), área de superfície (mm2) e structure model index (SMI). Foi, ainda, realizada a avaliação qualitativa das seções transversais por terço e por quadrante (MV, ML, DV, DL), sendo avaliado o toque de paredes. Os dados paramétricos foram analisados estatisticamente pelos testes ANOVA e t para amostras pareadas (α=5%). Não foi observada diferença estatística nos parâmetros quantitativos avaliados para Reciproc (142,77 ± 76,75; 42,22 ± 19,22; e 14,68 ± 17,69, respectivamente); WaveOne (105,09 ± 64,82; 29,54 ± 19,21; 14,81 ± 9,10, respectivamente); Twisted File (111,83 ± 43,09; 33,31 ± 18,40; 9,16 ± 6,57, respectivamente), e HyFlex (151,74 ± 149,37; 43,08 ± 41,44; 10,80 ± 8,52, respectivamente) (p=0,423). Dentro de cada grupo, foi observada diferença significante entre os resultados pré e pós-operatórios. O teste não paramétrico de Kruskal Wallis foi aplicado para a avaliação relativa ao toque de paredes. Foi observado que o sistema HyFlex apresentou a maior porcentagem de toques (82,3 ± 13,1), seguido por Reciproc (81,3 ± 16,9), Twisted File (78,3 ± 14,4) e, por fim, WaveOne (76,9 ± 21,7) (p>0,05). Em relação aos terços não foi observada diferença significativa (p=0,424). Os resultados da avaliação dos quadrantes intergrupo não demonstraram diferenças, porém indicaram tendência do preparo em direção à parede distal no terço cervical. Ao final, pôde-se concluir que os sistemas testados se equivalem quanto ao preparo de canais mesiais de molares inferiores; porém, nenhuma das técnicas foi capaz de tocar completamente em todas as paredes do canal radicular(AU)


The aim of this work was to analyze, in X-ray computed microtomography (µCT), the root canal preparation of mandibular molars with different engine driven systems. 58 mesial roots were selected, of anatomic diameter corresponding to #10. For the analysis in µTC, a stainless steel ring was manufactured in the same shape as the brace for µCT sampling, in order to serve as a mold to insert the roots in Duralay resin, so as to standardize the position of the specimen in the initial and final scanning. The canals were prepared with the Reciproc R25 (n=16), WaveOne Primary File (n=16), Twisted File (n=14) and HyFlex (n=12) systems. After being scanned, they were three-dimensionally reconstructed and quantitatively evaluated as regards the variation of volume (mm3), surface area (mm2) and structure model index (SMI). In addition, the qualitative evaluation of the cross sections by third and by quadrant (MV, ML, DV, DL) was carried out, along with the wall touching evaluation. The parametric data were statistically analyzed by ANOVA and t-tests for paired samples (α=5%). No statistical difference was observed in the qualitative parameters evaluated for Reciproc (142.77 ± 76.75; 42.22 ± 19.22; and 14.68 ± 17.69; respectively), WaveOne (105.09 ± 64.82; 29.54 ± 19.21; 14.81 ± 9.10; respectively), Twisted File (111.83 ± 43.09; 33.31 ± 18.40; 9.16 ± 6.57; respectively) and HyFlex (151.74 ± 149.37; 43.08 ± 41.44; 10.80 ± 8.52) (p=0,423). Significant difference was observed within each group between the pre- and post-results. The Kruskal-Wallis non-parametric test was applied for the evaluation as regards root canal wall touching. At the end, we observed that the HyFlex system presented the highest touching rate (82.3 ± 13.1), followed by the Reciproc (81.3 ± 16.9), Twisted File (78.3 ± 14.4) and, finally, WaveOne (76.9 ± 21.7) systems (p>0.05). As for the thirds, was not observed any significant difference (p=0.424). The results of the evaluation in the intergroup quadrants did not show any difference; however, they showed that there was a preparation trend towards the distal wall in the cervical third. At the end, it can conclude that the systems tested are equivalent as regards the preparation of mesial canals of mandibular molars, but none of the techniques was capable of fully touching all root canal walls(AU)


Sujets)
Humains , Mâle , Femelle , Préparation de canal radiculaire/instrumentation , Microtomographie aux rayons X , Molaire , Instruments dentaires
17.
Odonto (Säo Bernardo do Campo) ; 19(37): 55-62, jan.-jun.2011. tab, graf
Article Dans Portugais | LILACS | ID: lil-789951

Résumé

Analisar a capacidade de dissolução tecidual de diferentes soluções de hipoclorito de sódio em tecido conjuntivo e muscular esquelético de ratos.Metodologia: foram obtidos 60 fragmentos de tecido conjuntivo (dorso) e muscular esquelético (língua) de ratos da linhagem Wistar, que foram submetidos à ação solvente das soluções de hipoclorito de sódio comercializadas, prontas para uso, Hipoclor 1%, HW 1% e 2,5%, Limpa Bem 2,5% e soluções manipuladas nas mesmas concentrações. O tempo de dissolução foi cronometrado. O método de titulometria com iodo foi utilizado para confirmação do teor de cloro ativo das soluções utilizadas.Resultados: a análise estatística revelou diferença não significante entre os dois diferentes tecidos (p>0.05) e apresentou diferença significante (p<0.001) entre as concentrações de 1% e 2,5%. O tempo médio de dissolução em minutos no tecido conjuntivo foi: Limpa Bem 2,5% (80,4); Manipulado 2,5% (100,2); Hipoclor 1% (164,2); HW 2,5% (205,6); Manipulado 1% (278,4). No tecido muscular esquelético o tempo médio foi: Limpa Bem 2,5% (111,6); Manipulado 2,5% (171,6); Hipoclor 1% (178,5); HW 2,5% (219); Manipulado 1% (289,6). O HW 1% não foi capaz de dissolver os tecidos. Os resultados da titulometria demonstraram que as soluções testadas apresentavam teor de cloro ativo aceitáveis, com exceção da marca HW nas concentrações de 1% e 2,5%.Conclusão: ambos tecidos podem ser utilizados para a verificação da capacidade de dissolução tecidual do hipoclorito de sódio e que esta obedece uma relação diretamente proporcional a concentração do teor de cloro ativo...


The aim of this study was to analyze the ability of different solutions of sodium hypochlorite to dissolve connective and skeletal-muscle tissue of rats. Methodology: it was obtained 60 pieces of connective tissue (back) and skeletal-muscle (tongue) of Wistar rats that were subjected to solvent action of sodium hypochlorite solutions marketed, ready to use, 1% Hipoclor, 1 and 2, 5% HW, 2.5% Limpa Bem and solutions manipulated at the same concentrations. The dissolution time was recorded. The method of titration with iodine was used to confirm the active chlorine content of solutions used. Results: statistical analysis revealed no significant difference between the two different tissues (p> 0.05) and significantly difference (p <0.001) between concentrations 1% and 2.5%. The average time in minutes to dissolve the connective tissue was: 2.5% Limpa Bem (80.4); 2.5% Manipulated (100.2); 1% Hipoclor (164.2), 2.5% HW ( 205.6); 1% Manipulated (278.4). In skeletal muscle the average time was: 2.5% Limpa Bem (111.6); 2.5% Manipulated (171.6); 1% Hipoclor (178.5), 2.5% HW (219); 1% Manipulated (289.6). The 1% HW was not able to dissolve the tissues. The results of titrations demonstrated that the solutions tested had acceptable levels of chlorine, with the exception of brand HW concentrations of 1% and 2.5%.Conclusion: both tissues can be used for verifying the ability of tissue dissolution of sodium hypochlorite and that obeys a directly proportional to the concentration of active chlorine content...


Sujets)
Animaux , Rats , Hypochlorite de sodium/composition chimique , Liquides d'irrigation endocanalaire/composition chimique , Muscles squelettiques , Tissu conjonctif , Dissolution , Test de matériaux , Rat Wistar , Reproductibilité des résultats , Facteurs temps , Titrimétrie
18.
ROBRAC ; 20(52)abr. 2011. ilus
Article Dans Portugais | LILACS | ID: lil-609185

Résumé

O preparo do canal radicular tem sido avaliado por diferentes métodos ao longo dos anos: a microscopia ótica, a microscopia eletrônica de varredura, o exame radiográfico, analises fotográficas, moldagem, os métodos computadorizados e recentemente a análise tomográfica. Até 1987, a grande dificuldade na avaliação estava na ausência de um controle negativo uma vez que o preparo só podia ser avaliado após a instrumentação. Neste ano, Bramante et al. desenvolveram um método que permitiu a análise antes e após o preparo, usando dentes incluídos em resina e em morsa adequada e seccionados transversalmente, o qual se tornou o mais importante método para análise da qualidade do preparo do canal radicular. Em 1991 Sydney et al.3, desenvolveram uma plataforma radiográfica com a finalidade de padronizar as tomadas radiográficas, obtendo numa mesma película as imagens dos instrumentos antes e depois da instrumentação, para em seguida analisar a manutenção do trajeto original do canal radicular ou não. Face às restrições no uso de dentes naturais e as dificuldades de sua obtenção, o ensino básico da endodontica viu-se obrigado a buscar alternativas. Dente estas, o uso de canais simulados tem se mostrado uma opção de grande valia o que gerou ao desenvolvimento de uma plataforma radiográfica específica para estes, tornando-se valioso auxiliar no ensino da Endodontia.


Root canal preparation has been evaluated by different methods along the years: common optical microscope, the scanning electron microscope, radiographic examination, photographic studies, root canal models, computer programs and recently the tomography. Until 1987 the difficulty on analyzing root canal preparation was the negative control. In this year, Bramante et al. introduced a method that allowed the analysis before, during and after instrumentation. In 1991 Sydney et al.3 developed the radiographic platform method that makes possible to get in the same film the position of the file at the beginning and at the end of instrumentation. Deviations and imperfection are directly observed. The importance of simulated root canals in teaching endodontics is significant as we have difficulties and restrictions on getting human tooth for the grad students. The development of a radiographic platform for simulated root canals is an important teaching aid in endodontics.

19.
RSBO (Impr.) ; 8(1): 68-74, jan.-mar. 2011. tab
Article Dans Anglais | LILACS, BBO | ID: biblio-874402

Résumé

Introdução: A evolução da odontologia nos últimos anos revolucionou a prática diária em algumas especialidades. Uma dessas revoluções ocorreu na Endodontia devido ao avanço das técnicas rotatórias de preparo do canal radicular e sua posterior incorporação ao ensino dos graduandos de Odontologia. Objetivo: O objetivo deste estudo foi relatar uma experiência de 5 anos na graduação laboratorial e clínica do preparo endodôntico rotatório em uma universidade privada. Material e métodos: O levantamento dos dados foi realizado por meio de um questionário composto por nove questões objetivas; o questionário foi respondido pelos graduandos. Resultados: Os resultados mostraram uma aceitação positiva em relação ao ensino da técnica rotatória na graduação (94,7%). As seguintes vantagens foram destacadas: preparo mais rápido do canal radicular (91,6%) e redução do estresse do paciente (80,9%). Conclusão: Pode-se concluir que a experiência com as duas turmas de graduação foi excelente devido ao alto nível de aceitação da nova técnica pelos alunos


Introduction: Dentistry evolution in the past few years has revolutionized daily practice in some specialties. One of these revolutions has occurred in Endodontics due to the advancement of rotary techniques for root canal preparation and its subsequent incorporation into the teaching of Dentistry undergraduates. Objective: The aim of this study was to report a 5-year experience on the undergraduate laboratorial and clinical use of rotary endodontic preparation at a private university. Material and methods: Data survey was performed by using a questionnaire composed of nine objective questions; the questionnaire was answered by the undergraduates. Results: The results showed a positive acceptance regarding the undergraduate teaching of the rotary technique (94.7%). The following advantages were highlighted: faster root canal preparation (91.6%) and reduction of patient's stress (80.9%). Conclusion: It can be concluded that the experience with the two undergraduate groups was excellent due to the high acceptance level of the new technique by the students


Sujets)
Enquêtes et questionnaires , Instruments dentaires , Enseignement dentaire , Endodontie/instrumentation , Préparation de canal radiculaire , École dentaire
20.
Rev. odonto ciênc ; 26(2): 161-164, 2011. tab
Article Dans Anglais | LILACS, BBO | ID: lil-611664

Résumé

PURPOSE: To evaluate the effect of preflaring on the electronic measurement of working length in mesiobuccal roots of maxillary molars. METHODS: Thirty roots were embedded in an alginate model. Root canals were irrigated with 2.5 percent sodium hypochlorite, and a size 10 K file was inserted into the canal until the locator indicated that apical constriction had been reached. Then, the cervical portion of each canal was flared using the ProTaper system shaping files, whereupon electronic measurements were carried out again. RESULTS: The Student's t test for paired samples did not reveal statistically significant differences in the measurements obtained for preflared and unflared canals (P<0.05). CONCLUSION: Based on the lack of clinical significant relevance of the comparisons carried out in the present study, it is possible to conclude that electronic working length measurement can be carried out either before or after cervical preparation.


OBJETIVO: Avaliar o efeito do pré-alargamento sobre a medição eletrônica do comprimento de trabalho em raízes mésio-vestibulares de molares superiores. METODOLOGIA: Trinta raízes foram incluídas em um modelo de alginato. Canais radiculares foram irrigados com hipoclorito de sódio a 2,5 por cento, e uma lima de tamanho 10 K foi inserida no canal até onde o localizador indicou que a constrição apical tinha sido alcançada. A porção cervical de cada canal foi alargada usando as limas do sistema ProTaper, quando então as medições eletrônicas foram realizados novamente. RESULTADOS: O teste t de Student para amostras pareadas não mostrou diferenças estatisticamente significativas nas medições obtidas para canais pré-alargados e não alargados (P<0,05). CONCLUSÃO: Com base na falta de relevância clínica significativa das comparações realizadas no presente estudo, é possível concluir que a medição do comprimento eletrônico de trabalho pode ser realizado antes ou após o preparo cervical.


Sujets)
Humains , Préparation de canal radiculaire/instrumentation
SÉLECTION CITATIONS
Détails de la recherche