Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 13 de 13
Filtre
1.
Article | IMSEAR | ID: sea-220276

Résumé

Background: Atrial septal defect is a common congenital heart anomaly results in hemodynamically significant right ventriclular volume overload and an increase in the pulmonary venous flow. Aim: Evaluate changes of pulmonary venous flow parameters after transcatheter closure of secundum atrial septal defect. Patients and Methods: 50 patients with atrial septal defect aged from 3.5 to 31 years were included in the study. Pulmonary venous flow Doppler and right ventricular function were evaluated before and after successful transcatheter closure by transthoracic and transesophageal echocardiography. Results: The defect size ranged from 15 to 37mm with a mean (24.96 ±7.52), Normal systolic and diastolic waves of pulmonary venous flow Doppler were replaced by a continuous antegrade wave (mean 60±13.6 cm/s) in all atrial septal defect patients. Post-closure, the normal pulmonary venous flow pattern was regained, two separate waves, with a significant decrease in mean peak Systolic wave velocity (44.54±8.12 cm/sec vs 69.61±12.37, P=0.000), the mean peak Diastolic Wave velocity (55.85±9.81 cm/sec vs 72.65±10.38, P=0.000) and a significant increase in the mean peak atrial reversal wave velocity (28.75±4.63cm/sec vs 21.18±3.64, P=0.000). In multivariate regression analysis, significant predictors of haemodynamic significant ASD were ASD size,(odds ratio 1.508, P=0.007, 95% CI 1.153,2.671) and ASD/IAS ratio (odds ratio 2.313, P=0.001, 95% CI 1.064,3.104). Conclusions: Atrial septal defect patients have characteristic pulmonary venous flow pattern: continuous antegrade wave with systolic predominance and decrease in atrial reversal wave, which return to normal after closure. These changes could be helpful echocardiographic tool in prediction of successful closure of the defect.

2.
Ann Card Anaesth ; 2013 Jan; 16(1): 44-46
Article Dans Anglais | IMSEAR | ID: sea-145391

Résumé

Acute left ventricular (LV) failure has been reported after surgical closure of atrial septal defect (ASD) in adult patients. We report acute LV failure in a 56 year old gentleman following coronary artery bypass grafting (CABG) and surgical closure of ASD. Transesophageal echocardiography examination of the patient following closure of ASD and CABG showed a residual ASD and a shunt (Qp :Qs = 1.5). The residual ASD was closed after re-institution of cardiopulmonary bypass (CPB) under cardioplegic cardiac arrest. However, the patient did not tolerate closure of the residual ASD. The CPB was re-established and under cardioplegic cardiac arrest residual ASD was reopened to create a fenestration. This time patient was weaned easily from CPB. Postoperatively, 16 hours after extubation, patient became hemodynamically unstable, the patient was electively put on ventilator and intra-aortic balloon pump. Later the patient was weaned off successfully from ventilator. Retrospective analysis of pulmonary venous flow diastolic deceleration time (PVDT D ) recorded during prebypass period measured 102 msec suggestive of high left atrial pressure which indicate possibility of LV failure after ASD closure.


Sujets)
Adulte , Vitesse du flux sanguin/physiologie , Pontage aortocoronarien , Échocardiographie transoesophagienne/méthodes , Défaillance cardiaque/étiologie , Communications interauriculaires/chirurgie , Humains , Contrepulsion par ballon intra-aortique , Mâle , Complications postopératoires , Circulation pulmonaire/analyse , Statistique non paramétrique , Respirateurs artificiels , Sevrage de la ventilation mécanique
3.
Journal of Chinese Physician ; (12)2002.
Article Dans Chinois | WPRIM | ID: wpr-523902

Résumé

Objective To investigate the pulmonary venous flow pattern (PVFP) in atrial septal defect (ASD) and mitral stenosis (MS),to analyze the differences of PVFP in each group and evaluate their clinical value. Methods The characteristics of PVFP and mitral valve flow pattern in 42 patients of ASD and 17 patients of MS were prospectively compared by transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE), and also compared with the normal subject. Result The PVFP was significantly different between MS and ASD, including S、D、Ar、S-T (P

4.
Journal of the Korean Society of Echocardiography ; : 116-124, 2001.
Article Dans Coréen | WPRIM | ID: wpr-96653

Résumé

BACKGROUND: Restrictive left ventricular (LV) filling patterns after acute myocardial infarction (AMI) predict poor prognosis. Doppler indexes of LV inflow, especially peak velocity ratio of early versus late diastolic flow (E/A) and deceleration time, can predict heart failure or death. Doppler indexes of pulmonary venous flow are also used to diagnose restrictive LV filling, but their prognostic values after AMI are not known. METHODS: Doppler echocardiographic examination were performed in patients with AMI (n=122) between 7 to 10 days after attack, and followed for 30 months. Death group included 9 deaths (7.4%) during follow-up. 18 age-matched patients (control group) were selected from 70 patients without death, heart failure or readmission. Doppler echocardiographic indexes of peak systolic velocity (SV), peak diastolic velocity (DV), and peak reverse flow velocity associated with atrial contraction (AR) of pulmonary venous flow were measured by transthoracic echocardiography. RESULTS: Death group had lower SV (46.1+/-6.3 vs 57.0+/-14.7 cm/sec; p=0.059) and SV/DV ratio (1.26+/-0.50 vs 1.58+/-0.37; p=0.076). Death group had significantly more patients with SV/DV ratio less than 1.3 (67% vs 17%; p=0.026). AR was significantly different between death and control groups (29.7+/-7.8 vs 24.7+/-6.8 cm/sec; p=0.023). Death group had significantly more patients with AR greater than 25 (78% vs 33%; p=0.046). CONCLUSION: SV/DV ratio and AR of pulmonary venous flow predicted death after AMI.


Sujets)
Humains , Décélération , Échocardiographie , Échocardiographie-doppler , Études de suivi , Défaillance cardiaque , Infarctus du myocarde , Pronostic
5.
Korean Circulation Journal ; : 681-687, 1996.
Article Dans Coréen | WPRIM | ID: wpr-23802

Résumé

OBJECTIVES: Hypertension provokes left ventricular diastolic dysfunction due to decreased elasticity of the ventricular myocardium at first. It has been proposed that the Doppler echocardiography might provide information concerning diastole because of its ability to measure the blood flow velocities across the mitral valve noninvasively. But Doppler mitral velocity may be "normalized" in hypertensive patients in different conditions. The purpose of this study is to evaluate diastolic function in hypertensive hearts using Doppler echocardiography of the pulmonary venous flow in conjunction with mitral flow velocity pattern. METHODS: We measured the mitral flow velocity curves and the pulmonary flow velocity curves in fifty hypertensive patients(mean age : 56.3+/-10.0, man : 19, woman : 31) nad forty healthy adults(mean age : 51.6+/-12.5, man : 14, woman : 26) from March 1995 to December 1995 by using the SONO 1000 of Hewlett Packerd. RESULTS: 1) The mitral flow velocity pattern in 50 hypertensive patients was characterized by the decrease in the peak early diastolic filling velocity(E : 0.59+/-0.12m/sec) and the ratio of E to peak filling velocity(A : 1.00+/-0.46m/sec). Isovolumetric relaxation time and deceleration time were 127.2+/-33.3msec, 258.9+/-40.9msec respectively. They were longer than normotensive patients(P < 0.05). 2) The pulmonary venous flow velocity pattern in hypertensive patients was characterized by the decreased peak diastolic forward velocity(D : 33.7+/-9.8cm/sec) and the ratio of peak systolic forward velocity(S) to D(S/D : 1.60+/-0.5)(P < 0.05). 3) There was no relation between the flow velocity integral parameters and the peak flow velocity parameters of pulmonary venous flow pattern in hypertensive patients. 4) The dofference in the pulmonary venous duration and the mitral A wave duration at atrial contraction (DA-DR) was 20.9+/-29.4 msec in hypertensive patients. DA-DR in normatensive patients was 24.3+/-32.9msec. DA-DR was not significant in hypertensive patients compared with that of the healthy subjects (P < 0.05) CONCLUSION: Analysis of pulmonary venous flow velocity pattern in conjunction with mitral flow velocity pattern in hypertensive patients provides more accurate assessment of left ventricular diastolic function.


Sujets)
Femelle , Humains , Vitesse du flux sanguin , Décélération , Diastole , Échocardiographie-doppler , Élasticité , Coeur , Hypertension artérielle , Valve atrioventriculaire gauche , Myocarde , NAD , Relaxation
6.
Journal of the Korean Society of Echocardiography ; : 144-150, 1995.
Article Dans Coréen | WPRIM | ID: wpr-741258

Résumé

OBJECTIVES: In mitral stenosis, there is an alteration of normal left atrial hemodynamics because the narrowed mitral valve prolongs the decay in diastolic pressure, and atrial function may be impaired secondary to atrial fibrillation. In this study, we purposed to evaluation of the pulmonary venous flow patterns in the patients with mitral stenosis using transesophageal echocardiography. METHODS: The study was performed on 35 patients(13 men and 22 women, mean age 51±13.1 years) with mitral stenosis. We measured the left ventricular end-diastolic and end-systolic dimension, left atrial dimension, mitral valve area by planimetry method and the mean pressure gradient by transthoracic echocardiography. Systolic and diastolic peak velocities, atrial reversal and diastolic pressure half time of pulmonary venous flow by transesophageal echocardiography were evaluated. RESULTS: 1) The pulmonary venous peak systolic and diastolic flow velocities were 27.5±7.0cm/sec, 28.2±9.3cm/sec in patients with sinus rhythm, and 23.9±7.6cm/sec, 27.1±8.3cm/sec in patients with artial fibrillation. But there was no difference between patients with sinus rhythm and with atrial fibrillation. 2) The lesser mitral valve area, the more decreased peak systolic velocity and systolic to diastolic flow ratio. Especially, the systolic to diastolic flow ratio was significantly decreased(1.16±0.26, 0.95±0.23, 0.68±0.20, p < 0.05). But there was no difference at the peak diastolic velocity. 3) The thrombus or spontaneous echo contrast in the left atrium was not influence on the pulmonary venous flow pattern. CONCLUSION: In mitral stenosis, systolic flow and systolic to diastolic flow ratio decrease with the decrease of mitral valve area and diastolic flow becomes predominant, which may be useful in assessing the hemodynamics of mitral stenosis.


Sujets)
Femelle , Humains , Mâle , Fibrillation auriculaire , Fonction auriculaire , Pression sanguine , Échocardiographie , Échocardiographie transoesophagienne , Atrium du coeur , Hémodynamique , Méthodes , Valve atrioventriculaire gauche , Sténose mitrale , Thrombose
7.
Journal of the Korean Society of Echocardiography ; : 58-65, 1995.
Article Dans Coréen | WPRIM | ID: wpr-741244

Résumé

BACKGROUND: Doppler echocardiographic assessment of pulmonary venous flow has helped to characterize left ventricular diastolic function in various cardiac diseases of the heart. Abnormal pulmonary venous flow patterns have been described for a variety of conditions including restrictive myocardial disease such as cardiac amyloidosis, constrictive pericarditis,, dilated cardiomyopathy and they also helped to assess the severity of mitral regurgitation. Therefore this study was designed to evaluate the changes of pulmonary venous flow profiles in several cardiac diseases which are commonly encountered clinically, such as congestive heart failure, mitral regurgitation, mitral stenosis, aortic regurgitation and left ventricular hypertrophy and also the differences between right and left pulmonary venous flow pattern in these conditions. METHOD: We analyzed transesophageal echocardiographic findings of 328 patients(95 men and 233 women, mean age 54±13 years) in those right and left pulmonary venous flow were obtatinable. According to the echocardiographic findings, the above subjects were calssified into control group(n=167), conestive heart failure group(n=23), mitral regurgitation group (n=28), mitral stenosis group(n=10), aortic regurgitation group(n=37), and left ventricular hypertrophy group(n=23). In this study, the datas of subjects who did not show significant valvular lesions, ventricular hypertrophy, systolic or diastolic dysfuction were used as a control. Peak systolic velocity(peak S), systolic velocity integral(syst. V.I), peak diastolic velocity(peak D), diastolic velocity integral(dias. V.I.), peak velocity of atrial contraction(peak A), velocity integral of atrial contraction(A. V.I.), peak systolic velocity/peak diastolic velocity ratio(peak S/peak D), and systolic velocity integral/diastolic velocity integral ratio(syst./dias V.I) were measured in each group. RESULTS: The pulmonary venous flow pattern of right and left pulmonary vein in each group and comparisons between different groups showed the findings as follows(table). CONCLUSION: Analysis of pulmonary venous flow could be used as a useful index of evaluating diseased state of heart. Each group showed the relatively characteristic changes of pulmonary venous flow and those changes could be observed commonly in both right and left pulmonary vein. When one side of pulmonary veins could not be evaluated adequately, the valuable hemodynamic information could be obtained through the examintion of the other side pulmonary vein.


Sujets)
Femelle , Humains , Mâle , Amyloïdose , Insuffisance aortique , Cardiomyopathies , Cardiomyopathie dilatée , Échocardiographie , Échocardiographie transoesophagienne , Coeur , Cardiopathies , Défaillance cardiaque , Hémodynamique , Hypertrophie , Hypertrophie ventriculaire gauche , Méthodes , Insuffisance mitrale , Sténose mitrale , Péricardite constrictive , Veines pulmonaires
8.
Korean Circulation Journal ; : 554-561, 1994.
Article Dans Coréen | WPRIM | ID: wpr-103620

Résumé

BACKGROUND: Pulmonary venous flow(PVF) is closely related to left atrial pressure(LAP) and percutaneous mitral commissurotomy(PMC) reduces LAP rapidly. However, PVF pattern in mitral stenosis(MS) with sinus rhythm after PMC remains to be elucidated. METHODS: Transesophageal echocardiographic pulsed Doppler examination was performed within 24 hours before and after PMC to evaluate PVF pattern in 10 patients of MS with sinus rhythm. RESULTS: Before PMC, both peak velocity(PV) and velocity time integral(VTI) during systole had significant negative correlations with mean LAP(r=-0.70, r=-0.79, respectively). After PMC, both systolic PV and VTI increased significantly without significant changes in diastolic PV and VTI. However, there was no significant correlation between systolic PV and mean LAP, and between systolic VTI and mean LAP after PMC. CONCLUSION: In mitral stenosis with sinus rhythm, these data suggest that systolic PVF decreases with increase of mean LAP and PMC could reverse this change without affecting diastolic PVF. However, acute hemodynamic changes of left atrium induced by PMC may contribute to the absence of correlation between mean LAP and systolic PVF after PMC.


Sujets)
Humains , Échocardiographie , Atrium du coeur , Hémodynamique , Sténose mitrale , Systole
9.
Korean Circulation Journal ; : 259-271, 1994.
Article Dans Coréen | WPRIM | ID: wpr-174998

Résumé

BACKGROUND: Biphasic or triphasic or quadriphasic pattern of pulmonary venous flow has been described by color Doppler echocardiography in normal subjects. Absolute velocity measurements varied with the position of the probe in relation to the pulmonary vein. The purpose of this study is to evaluate the normal pulmonary venous flow pattern and compare the data according to age, body weight, height and body surface area. METHODS: 244 normal children underwent transthoracic echocardiography from December 1992 to July 1993. Age ranged from newborns to 13 years. From the apical four chamber view, pulmonary venous flow velocity and integral were obtained. RESULTS: Quadriphasic pulmonary flow pattern(early systolic flow, late systolic flow, diastolic flow, atrial reversal flow) was identified. Pulmonary venous peak flow velocity was not different according to increasement of age, body weight, height or body surface area. But pulmonic flow integral was significantly increased according as increasement of age, body weight, height, or body surface area. CONCLUSION: Transthoracic color Doppler echocardiography is a good noninvasive diagnostic tool to evaluate pulmonary venous flow pattern in children.


Sujets)
Enfant , Humains , Nouveau-né , Surface corporelle , Poids , Échocardiographie , Échocardiographie-doppler couleur , Veines pulmonaires
10.
Korean Circulation Journal ; : 220-227, 1994.
Article Dans Coréen | WPRIM | ID: wpr-193718

Résumé

BACKGROUND: Normally major forward pulmonary venous flow(PVF) into left atrium occurs during systole and early diastole. This is followed by the reversal of the PVF with atrial contraction during late diastole. Chronic increase of left atrial pressure and volume, and decrease of the left atrial compliance might alter the PVF pattern in patients with mitral stenosis. Moreover, the cardiac rhythm could be changed from sinus rhythm(SR) to atrial fibrillation(AF) with the progression of the disease. To elucidate the effect of these changes on PVF, we performed transesophageal echocardiographic(TEE) Doppler examination in 20 patients of mitral stenosis who were going to be taken Percutaneous mitral commissurotomy(PMC). METHOD: We measured the velocities of the PVF by TEE pulsed Doppler examination, and compared it with the hemodynamic parameters measured by cardiac catheterization in 20 patients of mitral stenosis who underwent the PMC. The SR was found in 12 patients and the rest showed established AF. RESULTS: 1) Doppler variables measured by TEE. 2) Hemodynamic parameters measured by cardiac catheterization. 3) In patients with SR, S-PV, S-VTI and S-FVTI showed negative correlation with mean LAP(r=-0.66, -0.67, -0.71, respectively, p<0.05). However in AF group, there is no correlation between Doppler variables and mean LAP. CONCLUSION: In mitral stenosis with SR, systolic PVF decreases with the increase of mean left atrial pressure and finally, diastolic PVE becomes predominant with the development of AF.


Sujets)
Humains , Pression auriculaire , Cathétérisme cardiaque , Sondes cardiaques , Compliance , Diastole , Échocardiographie , Échocardiographie transoesophagienne , Atrium du coeur , Hémodynamique , Sténose mitrale , Systole
11.
Korean Circulation Journal ; : 14-24, 1993.
Article Dans Coréen | WPRIM | ID: wpr-93364

Résumé

BACKGROUND: Recent development of transesophageal echocardiography(TEE) makes it possible to record pulmonary venous flow velocities(PVFV) accurately. To observe the differences of PVFV between normal controls and patients with severe mitral stenosis and to clarify the effects of percutaneous mitral valvuloplasty(PMV) on PVFV, TEE was performed in 12 normal controls and 11 patients with severe mitral stenosis. METHODS: PVFV was recorded from left upper pulmonary vein in longitudinal view of midesophageal position with a 5 MHz probe. Peak velocity and velocity-time integral(VTI) of systole and diastole were calculated with a digitizer. TEE was performed before and one day after PMV. Hemodynamic data(left atrial pressure, transmitral diastolic pressure gradient and cardiac output) were analyzed to demonstrate the possible correlation with PVFV. RESULTS: 1) 75%(9/12) of normal controls showed 4 distinct phases of PVFV with 2 systolic forward peaks, I diastolic forward and I end-diastolic backward peak. Peak systolic velocity was 52.6+/-.9cm/sec and peak diastolic forward velocity was 36.0+/-10.3cm/sec : Systolic VTI was greater than diastolic VTI, too(11.1+/-3.6cm vs 5.2+/-.6cm). 2) In patients with tight mitral stenosis(mean mitral area : 0.9cm2), most(10/11, 91%) showed one peak of systolic forward flow : Peak systolic velocity(27.8+/-15.8cm/sec) and systolic velocity-time integral(3.4+/-1.8cm)were significantly smaller than those of normal controls, while there was no statistical difference in peak diastolic forward velocity and velocity-time integral(34.5+/-12.7cm/sec, 4.3+/-1.7cm) compared to normal controls. There were no significant differences according to the rhythm. After successful PMV(mean mitral valve area : 1.9cm2) peak systolic and diastolic velocities increased up to 46.9+/-13.8cm/sec, 41.4+/-7.5cm/sec respectively, and systolic increase was statistically significant. The systolic increase of peak pulmonary venous velocity and velocity-time integral was more prominent in normal sinus group compared to patients with atrial fibrillation. 3) In patients with mitral stenosis, there was no correlation between peak diastolic forward velocity of pulmonary vein and peak transmitral early diastolic velocity(r=-0.19, p=0.40) : There was a weak negative correlation between mean left atrial pressure and peak systolic velocity of pulmonary vein(r=-0.46, p=0.03) in the pooled data of pre- and postvalvuloplasty(N=22). Also there noticed a negative correlation between diastolic transmitral pressure gradient and peak diastolic velocity of pulmonary vein(r=-0.49, p=0.02, N=22). CONCLUSION: Pulmonary venous velocities of patients with tight mitral stenosis showed decreased peak systolic velocity and VTI due to increased left atrial pressure and decreased compliance. which normalized immediately after successful PMV. In patients with mitral stenosis there seems to be somewhat different relationships between hemodynamic indices and pulmonary venous flow velocities, and further study with more patients with variable mitral valve area would be necessary to clarify the exact correlation.


Sujets)
Humains , Fibrillation auriculaire , Pression auriculaire , Pression sanguine , Compliance , Diastole , Échocardiographie transoesophagienne , Hémodynamique , Valve atrioventriculaire gauche , Sténose mitrale , Veines pulmonaires , Systole
12.
Korean Circulation Journal ; : 311-321, 1991.
Article Dans Coréen | WPRIM | ID: wpr-102754

Résumé

To evaluate the influencing factors on pulmonary venous flow(PVF) pattern, we studied the relationship between PVF and left ventricular ejection fracton(EF), mitral annulus motion(MAM) and transmitral flow using pulsed doppler echocardiography in patients with dilated cardiomyopathy(DCMP), acute myocardioal infarction(AMI), left ventricular hypertrophy(LVH) and atrial fibrillation(AE). Ther results were as follows : 1) In the normal controls(13 cases), two forward flow during ventricular systole(VS) and diastole(VD) and one retrograde flow during atrial systole(AS) were observed. The peak velocity of VS, VD and AS flow was 45.9cm/s, 42.8cm/s and -18.3cm/sec, respectively. The peak VS/VD ratio was 1.1. 2) In patients with DCMP(11 cases), (a) compared to the noraml subjects, the peak velocity of VS flow and VS/VD ratio were were significantly reduced(p<0.005 and p<0.001, respectively) and were positively correlated with ejection fraction(r=0.8 and r=0.7, respectively) (b) in 2 DCMP cases with severe mitral regurgitation, systolic retrograde flow was observed in the pulmonary vein instead of forward VS flow. 3) In 12 AMI cases and 7 LVH cases with normal or slightly diminished left ventricular systolic function but with abnormal diastolic function. (a) the peak velocity of VS flow and peak VS/VD ratio were significantly increased(r<0.005 and p<0.01, respectively). (b) the peak velocity of VD flow is positively correlated with transmitral E/A ratio(r=0.8) and the peak VS/VD ratio was positively correlated with transmitral pressure half time(r=0.8). (c) the peak velocity of retrograde AS flow was significantly increased(p<0.001). (d) there was no correlation between doppler parameters of PVF and left ventricular ejection fraction. 4) In patients with atrial fibrillation(10 cases), VS flow was markedly diminished or absent and only VD flow was observed. Also, retrograde AS flow was not observed. These findings suggest that the pattern of PVF is influnced by LVEF, MAM, transmitral inflow and atrial contraction. However, main contributary factors in determining the pattern of PVF in each disease are diverse according to its main pathophysiology.


Sujets)
Humains , Désoxycytidine monophosphate , Échocardiographie-doppler pulsé , Cardiopathies , Coeur , Insuffisance mitrale , Veines pulmonaires , Débit systolique
SÉLECTION CITATIONS
Détails de la recherche