Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 13 de 13
Filtrer
1.
Arq. bras. oftalmol ; 84(1): 37-44, Jan.-Feb. 2021. tab, graf
Article de Anglais | LILACS | ID: biblio-1153092

RÉSUMÉ

ABSTRACT Purpose: We aimed to evaluate the use of automated quantitative static and dynamic pupillometry in screening patients with type 2 diabetes mellitus and different stages of diabetic retinopathy. Method: 155 patients with type 2 diabetes mellitus (diabetes mellitus group) were included in this study and another 145 age- and sex-matched healthy individuals to serve as the control group. The diabetes mellitus group was divided into three subgroups: diabetes mellitus without diabetic retinopathy (No-diabetic retinopathy), nonproliferative diabetic retinopathy, and proliferative diabetic retinopathy. Static and dynamic pupillometry were performed using a rotating Scheimpflug camera with a topography-based system. Results: In terms of pupil diameter in both static and dynamic pupillometry (p<0.05), statistically significant differences were observed between the diabetes mellitus and control groups and also between the subgroups No-diabetic retinopathy, nonproliferative diabetic retinopathy, and proliferative diabetic retinopathy subgroups. But it was noted that No-diabetic retinopathy and nonproliferative diabetic retinopathy groups have showed similarities in the findings derived from static pupillometry under mesopic and photopic conditions. The two groups also appeared similar at all points during the dynamic pupillometry (p>0.05). However, it could be concluded that the proliferative diabetic retinopathy group was significantly different from the rest of the subgroups, No-diabetic retinopathy and nonproliferative diabetic retinopathy groups, in terms of all the static pupillometry measurements (p<0.05). The average speed of dilation was also significantly different between the diabetes mellitus and control groups and among the diabetes mellitus subgroups (p<0.001). While weak to moderate significant correlations were found between all pupil diameters in static and dynamic pupillometry with the duration of diabetes mellitus (p<0.05 for all), the HbA1c values showed no statistically significant correlations with any of the investigated static and dynamic pupil diameters (p>0.05 for all). Conclusion: This study revealed that the measurements derived from automated pupillometry are altered in patients with type 2 diabetes mellitus. The presence of nonproliferative diabetic retinopathy does not have a negative effect on pupillometry findings, but with proliferative diabetic retinopathy, significant alterations were observed. These results suggest that using automated quantitative pupillometry may be useful in verifying the severity of diabetic retinopathy.


RESUMO Objetivos: Procuramos avaliar o uso da pupilometria estática e dinâmica quantitativa automatizada na triagem de pacientes com diabetes mellitus tipo 2 e em di­ferentes estágios de retinopatia diabética. Métodos: Cento e cinquenta e cinco pacientes com diabetes mellitus tipo 2 (grupo com diabetes mellitus) foram incluídos neste estudo e outros 145 controles saudáveis pareados por idade e sexo para server como grupo controle. O grupo com diabetes mellitus foi dividido em três subgrupos: diabetes mellitus sem retinopatia diabética (retinopatia não diabética), retinopatia diabética não proliferativa e retinopatia diabética proliferativa. A pupilometria estática e dinâmica foi realizada utilizando uma camera rotative Scheimpflug com um sistema baseado em topografia. Resultados: Em termos de diâmetro da pupila, tanto na pupilometria estática quanto na dinâmica (p<0,05), foram observadas diferenças estatisticamente significantes entre os grupos diabetes mellitus e controle e também entre os subgrupos retinopatia não diabética, retinopatia diabética não proliferativa e retinopatia diabética proliferativa. Mas foi observado que os grupos de retinopatia não diabética e retinopatia diabética não proliferativa mostraram semelhanças nos achados derivados da pupilometria estática em condições mesópicas e fotópicas. Os dois grupos também pareciam semelhantes em todos os pontos durante a pupilometria dinâmica (p>0,05). No entanto, pode-se concluir que o grupo de retinopatia diabética proliferative foi sugnificativamente diferente do restante dos subgrupos, retinopatia não diabética e retinopatia diabética não proliferativa, em termos de todas as medidas de pupilometris estática (p<0,05). A velocidade média de dilatação também foi significativamente diferente entre os grupos diabetes mellitus e controle, e entre os subgrupos diabetes mellitus (p<0,001). Enquanto correlações significativas fracas a moderadas foram encontradas entre todos os diâmetros da pupila na pupilometria estática e dinâmica com a duração do diabetes mellitus (p<0,05 para todos), os valores de HbA1c não mostraram correlações estatisticamente significantes com nenhum dos diâmetros da pupila estática e dinâmica investigados (p>0,05 para todos). Conclusão: Este estudo revelou que as medidas derivadas da pupilometria automatizada estão alteradas em pacientes com diabetes mellitus tipo 2. A presença de retinopatia diabética não proliferativa não afeta negativamente os achados pupilomé­tricos, mas com a retinopatia diabética proliferative, alterações significativas foram observadas. Estes resultados sugerem que o uso da pupilometria quantitativa automatizada pode ser útil na verificação gravidade da retinopatia diabética.


Sujet(s)
Humains , Diabète de type 2 , Rétinopathie diabétique , Diabète de type 2/complications , Rétinopathie diabétique/diagnostic
2.
Rev. chil. neuro-psiquiatr ; 58(4): 324-336, dic. 2020. tab
Article de Espagnol | LILACS | ID: biblio-1388362

RÉSUMÉ

INTRODUCCIÓN: Disfunción del sistema nervioso autonómico ocurre en enfermedades del sistema nervioso central y periférico. Es importante cuantificar el compromiso simpático y parasimpático, diagnosticar la disfunción, monitorizar la evolución y la respuesta a terapias. Las principales pruebas funcionales son las cardiovasculares y sudomotoras. Existen además exámenes para estudiar la disfunción autonómica en distintos órganos y que son específicos de las especialidades médicas respectivas. DESARROLLO: Se describen los síntomas, las pruebas funcionales y métodos de estudio a nivel cardiovascular: simpáticas vasomotoras (noradrenérgicas) y cardiovagales (colinérgicas) y las pruebas para la sudoración: sudomotoras simpáticas (colinérgicas). Se describen los síntomas y exámenes a nivel pupilar, urogenital y gastrointestinal. Se señala la utilidad de las pruebas funcionales autonómicas en el estudio de distintas patologías neurológicas. CONCLUSIONES: la evaluación conjunta de los hallazgos clínicos y de las pruebas funcionales autonómicas permiten determinar el nivel anatómico y el grado de severidad de la disfunción autonómica con un fundamento fisiopatológico.


INTRODUCTION: Autonomic dysfunction occurs in patients with central and peripheral nervous system diseases. It is important to quantify the sympathetic and parasympathetic involvement for the diagnosis of the autonomic failure, for follow up and evaluate the response to a specific treatment. The most important studies are cardiovascular and sudomotor functional tests. There are other tests for the study of autonomic dysfunction in different organs, that are specific to respectively medical specialty. DEVELOPMENT: we describe main symptoms, functional autonomic tests and other methods to study cardiovascular: sympathetic vasomotor (noradrenergic) and cardiovagal (cholinergic) and sudomotor: sympathetic (cholinergic) functions. We describe symptoms and tests for assessment pupillary, genitourinary and gastrointestinal autonomic dysfunction. The indications for autonomic function testing in the different clinical scenarios are reported. CONCLUSIONS: combined evaluation of clinical and tests of autonomic function results allow to obtain the level and severity of autonomic dysfunction based upon pathophysiological support.


Sujet(s)
Humains , Maladies du système nerveux autonome/physiopathologie , Neuropathies périphériques/diagnostic , Système nerveux parasympathique/physiopathologie , Sudation , Système nerveux sympathique/physiopathologie
3.
Rev. mex. ing. bioméd ; 41(1): 29-42, ene.-abr. 2020. tab, graf
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1139322

RÉSUMÉ

Abstract The aim of this study is to investigate the effect of a continuous stream of pulses of monochromatic blue pulsed (BP) and a combination of blue and green pulsed (BGP) light-emitting diode (LED) light conditions on physiological responses. This study is an approach to clarify the most suitable LED combination and flickering frequency to evoke alertness when a continuous stream of pulsed LED light is delivered and may suggest applications of continuous pulsed light as support for task illumination for shift workers, hospital nurses, school students or office employees. Combinations were delivered by exposures of BPLED and BGPLED pulses at 100, 200, and 400 Hertz over two background light colors (BLC). Participants were exposed to 12 different light conditions in a counterbalanced procedure. By integrating measures of electroencephalogram (EEG) and pupil constriction; results suggested significant changes in responses during the interaction of BLC, LED, and EEG. Beta waves exhibited a statistically significance (p < 0.05) in arousal levels when exposed to BG light, although no active task was involved during exposure. Furthermore, pupil reacted with larger constriction towards BGPLED exposure than towards monochromatic BPLED exposure, thus demonstrating that a continuous stream of pulses can deliver the same irradiance as if delivered in a continuous flow and without affecting perception as no flickering was perceived in any of the conditions by a qualitative evaluation.


Resumen Este estudio tiene por objetivo determinar cuál es la combinación de luz LED más adecuada y la frecuencia de parpadeo que esta deba tener, para evocar un estado de alerta cuando se emite un flujo continuo de la misma al combinarla con una iluminación de ambiente; y poder sugerir aplicaciones como soporte para la iluminación de tareas para trabajadores por turnos, enfermeras, médicos, estudiantes; o en oficinas y hospitales. Es de original importancia resaltar que en el mercado no existe un producto comercial que se pueda ajustar para apoyar en el trabajo al estado de alerta, se tiene la limitante que estas son pruebas a nivel laboratorio y que posteriores pruebas serán necesarias para validar el producto final. El método usado se basó en las combinaciones que se administraron mediante exposiciones de luz azul pulsada (BPLED) y luz azul y verde combinadas (BGPLED) a frecuencias de 100, 200 y 400 Hz adicionadas a la iluminación ambiental (BLC). Los participantes fueron expuestos a 12 condiciones de luz diferentes en un experimento balanceado y contrapesado. Mediante la integración de medidas electroencefalográficas (EEG) y de constricción pupilar; los resultados sugirieron cambios significativos en las respuestas durante la interacción de BLC, LED y EEG. Las ondas beta mostraron una significancia estadística (p <0.05) en los niveles de activación cuando se expusieron a la luz BGPLED, además, la pupila reaccionó con una mayor constricción hacia la exposición a BGPLED que hacia la exposición BPLED monocromática, adicionalmente se demostró que un flujo continuo de pulsos puede proporcionar una irradiación igual a la que se emite en flujo continuo; se concluyó e identificó además la frecuencia (100 Hz) que mejor evoca estado de alerta encefalográfíca y sin afectar la percepción de los usuarios en cuanto a su percepción del ambiente de acuerdo a la evaluación cualitativa.

4.
Rev. Soc. Colomb. Oftalmol ; 53(1): 31-36, 2020. ilus.
Article de Espagnol | LILACS, COLNAL | ID: biblio-1128156

RÉSUMÉ

Introducción: se presenta una serie de 3 casos de síndrome de retracción iridiana (SRI) asociados a desprendimiento de retina regmatógeno (DRR) y desprendimiento coroideo. Objetivo: dar a conocer las características clínicas y tomográficas de tres pacientes con SRI asociado a desprendimiento de retina regmatógeno. Diseño del estudio: serie de casos. Resumen del caso: tres pacientes que presentaron DRR asociado a SRI. El tiempo de evolución promedio fue de 21 días (15-30 días), 2 de los 3 pacientes tuvieron resolución del SRI posterior al inicio de midriáticos y antes de ser intervenidos por el desprendimiento de retina, y 2 tuvieron presencia de proliferación vitreoretiniana (PVR) a pesar del corto tiempo de evolución. Adicionalmente estos 2 pacientes cursaron con desprendimientos coroideos. Todos los pacientes tuvieron un buen resultado estructural, AV menor o igual a 20/400, no redesprendimientos ni recurrencias de SRI durante el seguimiento. Conclusión: ante un paciente con SRI en el cual no sea posible valorar polo posterior, se debe tener en cuenta el diagnóstico de desprendimiento de retina regmatógeno. El SRI puede considerarse como un factor de mal pronóstico en pacientes con desprendimiento de retina regmatógeno.


Background: to report a 3 cases series of patients with iris retraction syndrome (IRS). Objective: introduce the clinical and tomographic features of tree patients with IRS following RRD. Study design: case series. Case summary: three patients presented IRS following RRD. They presented with an average evolution of 21 days (15 to 30 days), 2 patients had resolution of the IRS after mydriatics and before receiving surgical treatment for retinal detacthment, and 2 had vitreoretinal proliferation despite the short time. Besides, these 2 patients had choroidal detachments discovered in the operating room. All patients had good structural outcomes, visual acuity less or equal than 20/400, no re-detachment of the retina and no recurrence of IRS during follow up. Conclusion: the presence of a retinal detachment should be suspected in a patient with IRS in which it´s not possible to assess the posterior pole, and it should be considered a bad prognostic factor if present.


Sujet(s)
Décollement de la rétine/diagnostic , Hypotension oculaire/diagnostic , Hypotension oculaire/physiopathologie , Syndrome de rétraction de Duane , Maladies de l'iris
5.
Rev. bras. anestesiol ; 69(3): 319-321, May-June 2019.
Article de Anglais | LILACS | ID: biblio-1013418

RÉSUMÉ

Abstract Prone position though is commonly used for better access to surgical site, but may be associated with a variety of complications. Perioperative Visual Disturbances or loss is rare but a devastating complication that is primarily associated with spine surgeries in prone position. In this case we report a 42 year old ASA-II patient who developed anisocoria with left pupillary dilatation following lumbar microdiscectomy in prone position. Following further evaluation of the patient, segmental pupillary palsy of the left pupillary muscles was found to be the possible cause of anisocoria. Anisocoria partially improved but persisted till follow up.


Resumo O posicionamento em decúbito ventral, embora comumente usado para melhorar o acesso ao local cirúrgico, pode estar associado a uma variedade de complicações. Distúrbios ou perda visual no Perioperatório é uma complicação rara, mas devastadora, que está principalmente associada à cirurgia de coluna vertebral em decúbito ventral. Relatamos aqui o caso de um paciente de 42 anos de idade, ASA - II, que desenvolveu anisocoria com dilatação pupilar esquerda após microdiscetomia lombar em decúbito ventral. Após uma avaliação adicional do paciente, observamos que a paralisia segmentar dos músculos pupilares esquerdos seria a possível causa de anisocoria. A anisocoria melhorou parcialmente, mas persistiu até o acompanhamento.


Sujet(s)
Humains , Femelle , Adulte , Anisocorie/étiologie , Mydriase/étiologie , Décubitus ventral , Discectomie/méthodes , Complications postopératoires/diagnostic , Études de suivi , Discectomie/effets indésirables , Vertèbres lombales/chirurgie
6.
Psico (Porto Alegre) ; 50(2): e30033, 2019.
Article de Anglais | LILACS | ID: biblio-1008333

RÉSUMÉ

The objective of this study was to investigate whether there is a relationship between pupil diameter and facial attractiveness. Participated in the study 60 young adults (30 men and 30 women) between 18 and 26 years of age (M=20.65, SD=2.20). Ten different unfamiliar neutral faces (five men and five women) were used as stimuli. The pupil diameter of each face was manipulated with pupil diameters of 2, 3, 4, 5 and 6mm (10 faces x5 pupil diameters=50 stimuli). A two-step study was carried out with the same sample and the same sets of faces, seeking to understand the difference of responses between subjects of both sexes. In phase I, result indicated a significant difference in relation to the pupil diameter factor for both the men (ꭓ²=21.93, p<.05) and the women (ꭓ²=44.73, p<.05). In phase II, the results indicated significant differences in relation to the pupil size [F(1, 234)=19.06, p<0.05]. The post-hoc Tukey HSD test showed that both the men and the women differently judged the faces with a pupil diameter of 2mm in relation to the faces with pupil diameters of 3, 4, 5 and 6mm (p<.05). Also, a significant difference between the diameter of 5mm in relation to the diameter of 3mm (p<.05). In general, the results indicate that the pupil diameter is a structural component of the human face that plays an important role in the process of judging facial attractiveness.


O objetivo deste estudo foi investigar a relação entre o diâmetro da pupila e a atratividade facial. Participaram da pesquisa 60 jovens com idade entre 18 e 26 anos. Foram utilizadas dez faces de adultos jovens, manipulou-se o diâmetro de cada pupila com variações de 2, 3, 4, 5 e 6mm. Realizou-se um estudo em duas etapas: na fase I, o resultado indicou diferença significativa para o fator de diâmetro pupilar tanto para homens quanto para mulheres (p<0,05). Na fase II, os resultados indicaram diferenças significativas em relação ao tamanho da pupila (p<0,05). O teste post-hoc Tukey mostrou que tanto os homens quanto as mulheres avaliaram diferentemente as faces com diâmetro pupilar de 2mm (p<0,05). Em geral, os resultados indicam que o diâmetro da pupila é um componente da face humana que desempenha um importante função no processo de julgamento da atratividade facial.


El objetivo de este estudio fue investigar si existe una relación entre el diámetro pupilar y el atractivo facial. Participaron en la estudio 60 adultos jóvenes (30 hombres y 30 mujeres) entre 18 y 26 años de edad (M=20.65, DE=2.20). Se utilizaron como estímulos diez rostros neutrales desconocidos diferentes (cinco hombres y cinco mujeres). El diámetro de la pupila de cada cara se manipuló con diámetros de pupila de 2, 3, 4, 5 y 6mm (10 caras x5 diámetros de pupila=50 estímulos). Se realizó un estudio en dos etapas con la misma muestra y los mismos conjuntos de caras buscando entender la diferencia de respuestas entre sujetos de ambos sexos. En la fase I, el resultado indicó una diferencia significativa en relación al factor de diámetro de la pupila tanto para los hombres (ꭓ²=21.93, p <0.05) como para las mujeres (ꭓ²=44.73, p<0.05). En la fase II, los resultados indicaron diferencias significativas en relación al tamaño de la pupila [F(1, 234)=19,06, p<0,05]. La prueba post-hoc de Tukey HSD mostró que tanto los hombres como las mujeres evaluaron de manera diferente las caras con un diámetro pupilar de 2mm con respecto a las caras con diámetros pupilares de 3, 4, 5 y 6mm (p<0,05). Se observó una diferencia significativa entre el diámetro de 5mm en relación al diámetro de 3mm (p<0,05). En general, los resultados indican que el diámetro de la pupila es un componente estructural de la cara humana que desempeña una importante función en el proceso de juicio del atractivo facial.


Sujet(s)
Pupille , Relations interpersonnelles , Oeil , Face
7.
Arq. bras. med. vet. zootec ; 68(3): 641-650, tab, graf
Article de Anglais | LILACS, VETINDEX | ID: lil-785710

RÉSUMÉ

The aim of this study was to evaluate changes in intraocular pressure (IOP), pupil size (PS), blood pressure (BP), heart rate (HR), and ECG variables (Pms wave PmV, PR interval, QRS complex, RMV wave and QT intervals) over time during the instillation of 0.5% timolol, 0.5% levobunolol and 0.5% apraclonidine in clinically normal dogs. Ten adult beagles were used. Baseline values were measured at 8a.m., 2p.m. and 8p.m., for three consecutive days. A waiting period of 10 days between the administrations of each drug was established. For 15 consecutive days, the drug being tested was instilled in one eye of each dog twice a day (7a.m. and 7p.m.). The parameters were evaluated at the aforementioned times on days 3, 6, 9, 12 and 15. Data were statistically compared using the Bonferroni test and one-way repeated measures analysis of variance (P<0.05). The Pearson test was used to evaluate any correlation between QT interval, HR and BP. The tested drugs did not find a decrease in IOP. A significant decreased in PS was observed in almost all dogs following levobunolol administration, relative to the control eye. A significant decrease in HR was observed on day 3 following levobunolol treatment, while apraclonidine induced an increase on day 15. Blood pressure was reduced in all measurement time points following apraclonidine treatment. A negative correlation between QT interval and HR was only observed in dogs treated with timolol. In conclusion, levobunolol was the only drug that induced significant alterations in PS. Apraclonidine was the only drug that induced systemic hypotension. Timolol was the only drug to that induced a negative correlation between QT and HR.(AU)


O objetivo deste estudo foi avaliar as mudanças na pressão intraocular (PIO), no diâmetro pupilar (DP), na pressão sanguínea (PS), na frequência cardíaca (FC) e nas variáveis eletrocardiográficas (onda Pms, PmV, intervalo PR, complexo QRS, onda RmV e intervalo QT), ao longo do tempo da instilação do timolol 0,5%, do levobunolol 0,5% e da apraclonidina 0,5% em cães clinicamente normais. Dez Beagles adultos compuseram o estudo. Valores basais foram mensurados às oito,, 14 e 20 horas, durante três dias consecutivos. Foi instituído um período de espera de 10 dias entre a administração de cada fármaco. Durante 15 dias consecutivos, um olho de cada animal recebeu uma gota de cada um deles, a intervalos de 12 horas (às sete e às 19 horas). Os parâmetros foram avaliados nos momentos acima referidos, nos dias três, seis, nove, 12 e 15. Os dados foram comparados estatisticamente empregando-se o teste de Bonferroni após análise de variância para medidas repetidas (P<0,05). Teste de Pearson foi utilizado para correlação entre o intervalo QT com a FC e a PS. Não se encontrou diminuição da PIO. Observou-se redução significativa do DP na quase totalidade dos animais que receberam levobunol, relativamente ao olho controle. Diminuição significativa da FC foi vista ao terceiro dia após a administração do levobunolol, enquanto apraclonidina induziu aumento no 15º dia. A pressão arterial foi reduzida em todos os momentos com a apraclonidina. Observou-se correlação negativa entre o intervalo QT e a FC apenas nos indivíduos tratados com o timolol. Em conclusão, levobunolol foi o único fármaco que induziu alterações significativas no DP. A apraclonidina foi o único fármaco que induziu hipotensão sistêmica significativa. O timolol foi o único a ensejar correlação negativa entre o intervalo QT e a FC.(AU)


Sujet(s)
Animaux , Chiens , Pression sanguine , Rythme cardiaque , Pression intraoculaire , Lévobunolol/effets indésirables , Lévobunolol/analyse , Timolol/effets indésirables , Timolol/analyse , Analyse de variance , Instillation de médicaments , Pupille
8.
Arq. bras. oftalmol ; 77(6): 360-363, Nov-Dec/2014. tab, graf
Article de Anglais | LILACS | ID: lil-735797

RÉSUMÉ

Purpose: To assess the prevalence and treatment outcomes of angle-closure mechanisms other than pupillary block in a population of Brazilian patients. Methods: A retrospective chart review was conducted to evaluate patients who had undergone laser peripheral iridotomy (LPI) due to occludable angles at a single institution between July 2009 and April 2012. An occludable angle was defined as an eye in which the posterior trabecular meshwork was not visible for ≥180° on dark-room gonioscopy. Key exclusion criteria were any form of secondary glaucoma and the presence of >90° of peripheral anterior synechiae. Collected data were age, race, gender, angle-closure mechanism (based on indentation goniocopy and ultrasound biomicroscopy), intraocular pressure (IOP), number of antiglaucoma medications and subsequent management during follow-up. If both eyes were eligible, the right eye was arbitrarily selected for analysis. Results: A total of 196 eyes of 196 consecutive patients (mean age 58.3 ± 11.6 years) who underwent LPI were included. In most of the patients [86% (169 patients; 133 women and 36 men]), LPI sucessfully opened the angle. Mean IOP was reduced from 18.3 ± 6.4 mmHg to 15.4 ± 4.5 mmHg after LPI (p<0.01). Among the 27 patients with persistent occludable angles, the most common underlying mechanisms were plateau iris (56%) and lens-induced component (34%). Most of these patients (85%) were treated with argon laser peripheral iridoplasty (ALPI); approximately 90% showed non-occludable angles following the laser procedure (mean IOP reduction of 18.9%), with no significant differences between patients with plateau iris and lens-induced components (p=0.34; mean follow-up of 11.4 ± 3.6 months). Conclusion: Our findings suggest that, in this population of Brazilian patients, several eyes with angle closure were not completely treated with LPI. In the present large case series involving middle-age patients, plateau iris was the ...


Objetivo: Reportar a prevalência e os resultados terapêuticos em casos de fechamento angular por outros mecanismos além de bloqueio pupilar em uma população de pacientes brasileiros. Métodos: Realizou-se um estudo retrospectivo para avaliar pacientes apresentando ângulo oclusível submetidos à iridotomia periférica a laser (LPI), em uma única instituição, entre julho/2009 e abril/2012. Ângulo oclusível foi definido pela não observação do trabeculado posterior em mais de 180° à gonioscopia sem identação. Olhos com glaucomas secundários ou >90º de sinéquia anterior periférica foram excluídos. Foram coletados os seguintes dados: idade, raça, sexo, mecanismo de fechamento angular (com base na gonioscopia e biomicroscopia ultrassônica), pressão intraocular (PIO), número de medicações antiglaucomatosas e manejo subsequente durante o seguimento. Sempre que ambos os olhos eram elegíveis, o olho direito foi escolhido arbitrariamente para análise. Resultados: Foram incluídos 196 olhos de 196 pacientes (58,3 ± 11,6 anos) que foram submetidos à LPI. Na maioria dos casos [86% (169 pacientes; 133 mulheres e 36 homens), a LPI foi capaz de abrir o ângulo. A PIO média foi reduzida de 18,3 ± 6,4 para 15,4 ± 4,5 mmHg após a LPI (p<0,01). Entre os 27 casos que persistiram com ângulo oclusível, os mecanismos mais comuns envolvidos foram íris em platô (56%) e induzido por componente cristaliniano (34%). A maioria desses casos (85%) foram tratados com iridoplastia periférica a laser (ALPI). Aproximadamente 90% tornaram-se não oclusíveis após a ALPI (redução média da PIO de 18,9%), não havendo diferença significativa entre os pacientes com componentes de íris em platô ou cristaliniano (p=0,34; seguimento médio de 11,4 ± 3,6 meses). Conclusões: Nossos resultados sugerem que, nessa população de pacientes brasileiros, parte dos olhos com fechamento angular não foi completamente tratada com LPI. Nesta série de pacientes de meia-idade, a presença de íris em ...


Sujet(s)
Sujet âgé , Femelle , Humains , Mâle , Adulte d'âge moyen , Glaucome à angle fermé/épidémiologie , Glaucome à angle fermé/chirurgie , Iridectomie/méthodes , Brésil/épidémiologie , Glaucome à angle fermé/physiopathologie , Maladies de l'iris/chirurgie , Lasers à gaz/usage thérapeutique , Prévalence , Troubles pupillaires/physiopathologie , Études rétrospectives , Statistique non paramétrique , Résultat thérapeutique
9.
Arq. bras. oftalmol ; 76(5): 296-300, set.-out. 2013. ilus, tab
Article de Anglais | LILACS | ID: lil-690608

RÉSUMÉ

PURPOSE: Identify ideal profiles in patients undergoing to photorefractive laser surgery with the aid of an automated pupillometry and psychometric analysis of patients with visual function questionnaire (VQF 25). METHODS: Seventy-seven patients undergoing photorefractive laser surgery laser (LASIK) were analyzed with the aid of an automated digital pupillometer based on an infrared camera coupled to the optical head of a videokeratography system. Patients underwent complete ophthalmic evaluation and documentation of the pupillary behavior under different intensities of illumination, simulating situations of everyday life. Visual quality function questionnaire, translated to Portuguese was assessed. RESULTS: All patients, regardless of pupillary change under varying conditions of illumination (scotopic, mesopic and photopic) showed improvement in all sub-groups of the VQF 25. Pupil diameter was not the primary determinant of patients' visual satisfaction. CONCLUSION: Despite digital pupillometer has proven to be a useful tool in documenting and understanding of pupil behavior, a set of factors such as psycho-social profile, preoperative ametropy and final residual ametropy, contributed decisively to determine the degree of satisfaction of patients undergoing LASIK.


OBJETIVO: Identificar perfis ideais em pacientes submetidos à cirurgia fotorrefrativa a laser com o auxílio de um pupilômetro automatizado e análise psicométrica de pacientes com o questionário de função visual (VQF 25). MÉTODOS: Setenta e sete pacientes submetidos à cirurgia fotorrefrativa a laser (LASIK) foram analisados com o auxílio de um pupilômetro digital automatizado baseado em uma câmera de infravermelho acoplado à cabeça óptica de um sistema de videoceratografia. Os pacientes foram submetidos à avaliação oftalmológica completa e documentação do comportamento pupilar em diferentes intensidades de iluminação, simulando situações da vida cotidiana. O questionário de qualidade da função visual, traduzido para o Português, foi avaliado. RESULTADOS: Todos os pacientes, independentemente da mudança pupilar em diferentes condições de iluminação (escotópica, mesópica e fotópica) apresentaram melhora em todos os subgrupos do VQF 25. O diâmetro pupilar não foi o principal determinante da satisfação visual dos pacientes. CONCLUSÃO: Apesar do pupilômetro digital ter provado ser uma ferramenta útil na documentação e compreensão do comportamento da pupila, um conjunto de fatores, tais como o perfil psicossocial, ametropia pré-operatória e ametropia residual final, contribuiu de forma decisiva para determinar o grau de satisfação dos pacientes submetidos a LASIK.


Sujet(s)
Adulte , Femelle , Humains , Mâle , Adulte d'âge moyen , Jeune adulte , Kératomileusis in situ avec laser excimère/psychologie , Réflexe pupillaire/physiologie , Acuité visuelle/physiologie , Kératomileusis in situ avec laser excimère , Psychométrie , Photokératectomie réfractive/psychologie , Photokératectomie réfractive , Enquêtes et questionnaires
10.
Arq. bras. oftalmol ; 75(5): 337-340, set.-out. 2012. graf, tab
Article de Portugais | LILACS | ID: lil-667578

RÉSUMÉ

OBJETIVO: Descrever a implantação do teste de reflexo vermelho nas 30 cidades de inserção do Hospital das Clínicas da Faculdade de Medicina de Botucatu, HC/FMB/UNESP (480.337 habitantes), a criação de um centro para referência de crianças com reflexo vermelho alterado ou duvidoso, a Triagem do reflexo vermelho e outro para o tratamento da catarata infantil, o Centro de tratamento da catarata infantil. MÉTODOS: O exame do reflexo vermelho foi divulgado em 30 cidades da região de Botucatu. Foram realizadas palestras aos municípios, convocados pelo Departamento Regional de Saúde VI do estado de São Paulo (DRS VI). Foram distribuídos 109 "pen torch ophthalmoscope", às maternidades e Unidades Básicas de Saúde (UBSs) das cidades. A Triagem do reflexo vermelho recebeu os casos de reflexo vermelho alterado ou duvidoso e estabeleceu o diagnóstico oftalmológico. O Centro de tratamento da catarata infantil realizou o exame pré-operatório, o tratamento cirúrgico e o acompanhamento das crianças com catarata. RESULTADOS: Após um ano de funcionamento a Triagem do reflexo vermelho atendeu 29 crianças, 17 do sexo masculino e 12 do feminino, com idade média e desvio padrão (dp) de 10,09 ± 20,35 meses (7 dias - 98 meses). 16 pacientes foram encaminhados com reflexo vermelho alterado, idade média e dp de 13,17 ± 24,14 meses (7 dias - 98 meses), a alteração foi confirmada em todos os casos, 13 deles apresentavam catarata. Em 13 encaminhamentos com reflexo duvidoso, idade média e dp de 6,29 ± 14,46 meses (7 dias - 98 meses), a alteração não se confirmou. A incidência de alterações do reflexo vermelho encontradas foi de 9,2/10.000 nascidos vivos e a incidência the catarata foi de 7,9/10.000 nascidos vivos. CONCLUSÃO: Descrevemos a implantação do Teste do reflexo vermelho na Região de Botucatu, a criação da Triagem do reflexo vermelho e do Centro de tratamento da catarata infantil e dificuldades encontradas.


PURPOSE: To describe the implantation of the red reflex test in 30 cities in the area of Botucatu Medical School Clinical Hospital, (480,337 inhabitants) and the creation of a reference Center for children with red reflex changes, the Red reflex screening and another Center for treatment of childhood cataract. METHODS: The red reflex exam was released in 30 cities of the surrounding Botucatu area, lectures were done in the cities invited to participate by the Regional Department of Health.109 pen torch ophthalmoscopes were distributed to the hospital maternities and primary care units. The Red reflex screening attended cases of altered or doubtful red reflex and established the diagnosis. The Center for treatment of childhood cataract performed the preoperative examination, surgical treatment and follow-up of children with cataracts. RESULTS: After one year the Red reflex screening attended 29 children, 17 males and 12 females, mean age and pattern deviation (PD) of 10.09 ± 20.35 months (7 days - 98 months old). 16 patients were referred with altered red reflex, with a mean age and pattern deviation of 13.17 ± 24.14 months (7 days - 98 months old). The alteration was confirmed in all of these cases. 13 children had cataract. In 13 children with doubtful exam, with a mean age and PD of 6.29 ± 14.46 months (7 days - 54 months old), the alteration was not confirmed in any of these patients. The incidence of negative red reflex found among newborns was 9.2/10,000 and the incidence cataracts in this same group was 7.9/10,000. CONCLUSION: We described the implantation of the red reflex exam in the Botucatu area, and the creation of a reference Center for eye examination of children with changes in the red reflex, and the creation of a reference Center for treatment of childhood cataract and difficulties.


Sujet(s)
Enfant , Enfant d'âge préscolaire , Femelle , Humains , Nourrisson , Nouveau-né , Mâle , Cataracte/diagnostic , Maladies de l'oeil/diagnostic , Réflexe/physiologie , Dépistage visuel/méthodes , Cataracte/congénital , Cataracte/thérapie , Maladies de l'oeil/congénital , Maladies de l'oeil/thérapie , Pigmentation , Acuité visuelle
11.
Cienc. tecnol. salud vis. ocul ; 9(2): 123-130, ene.-jun. 2011. ilus
Article de Espagnol | LILACS | ID: lil-653286

RÉSUMÉ

En la diabetes mellitus se han descrito alteraciones en el control que ejerce el sistema nervioso autónomo sobre diferentes órganos y sistemas. Dentro de estas se encuentra la alteración sobrela regulación autonómica de la pupila, a la que se le ha denominado neuropatía autonómica pupilar diabética (NAPD). El presente artículo es una revisión de la relación que existe entre la dinámica pupilar y los cambios retinales en pacientes diabéticos tipo 2, y hace una descripciónde la dinámica pupilar y de los cambios retinales en pacientes diabéticos, así como de la relación que existe entre ellas y el tiempo de evolución de la enfermedad.


Alterations have been described in the autonomic nervous system’s control on different organs and systems as a result of diabetes mellitus. They include the alteration of the autonomic regulation ofthe pupil, which has been called Diabetic Autonomic Pupillary Neuropathy (NAPD, for its initialsin Spanish). This paper is a review of the existing relationship between pupillary dynamic and retinal changes in type 2 diabetic patients, and describes pupillary dynamics and retinal changes in diabetic patients, as well as the relationship between them and the time of evolution of the disease.


Sujet(s)
Système nerveux autonome , Diabète , Pupille , Rétine
12.
Einstein (Säo Paulo) ; 7(3)set. 2009. ilus
Article de Anglais, Portugais | LILACS | ID: lil-530791

RÉSUMÉ

Até há bem pouco tempo, o exame oftalmológico feito em recém-nascidos, ainda na maternidade, não era uma prioridade; e mesmo hoje em dia, em um grande número de serviços de Neonatologia, os olhos dos recém-nascidos não são adequadamente examinados. As consequências são desastrosas, pois quando a alteração é descoberta tardiamente, a criança poderá ter perdido irremediavelmente a visão. O exame oftalmológico, feito ainda no berçário pelo neonatologista, permite um diagnóstico e encaminhamento precoce da criança, propiciando um tratamento efetivo que possibilite o desenvolvimento adequado da visão. O presente artigo salienta a importância da pesquisa do reflexo vermelho em recém-nascidos e discute as principais causas da leucocoria, como a catarata, o retinoblastoma e as doenças da retina e do vítreo, a fim de alertar pediatras e neonatologistas para o problema. Ênfase especial é dada ao retinoblastoma, problema que afeta de 1/14.000 a 1/20.000 dos recém-nascidos vivos, sendo apresentados aspectos genéticos, clínicos, diagnósticos e terapêuticos dessa afecção. O seu diagnóstico precoce é a base para a redução da morbimortalidade da doença.

13.
Arq. bras. med. vet. zootec ; 60(5): 1045-1052, out. 2008. ilus
Article de Anglais | LILACS | ID: lil-500068

RÉSUMÉ

The effects of topical levobunolol with the fixed combination of 2 percent dorzolamide-0.5 percent timolol and the association of 2 percent dorzolamide with 0.5 percent levobunolol on intraocular pressure (IOP), pupil size (PS), heart rate (HR), and conjunctival hyperemia in eighteen halthy cats were investigated and compared. IOP, PS, HR, and conjuntival hyperemia were daily recorded at three times (9a.m., 2p.m., and 6p.m.). Three groups were formed (n=6), and one eye of each animal was randomly selected and treated with topical levobunolol (L), or commercial combination of dorzolamide-timolol (DT), or the association of dorzolamide with levobunolol (DL). The first day (0) consisted of recording of baseline values. On the next four consecutive days, drugs were instilled at 8a.m. and 8p.m. and measurements were taken at the same times fore cited. Comparing with the baseline values, all evaluated parameters significantly decreased (P<0.001). Conjuntival hyperemia was not seen. Levobunolol significantly declined IOP, PS, and HR in normal cats, and showed a stronger effect in lowering HR, when compared to dorzolamide-timolol effect. No synergistic effect in IOP declining was noted when levobunolol dorzolamide was added to levobunolol.


Estudaram-se e compararam-se os efeitos do levobunolol, da combinação fixa de dorzolamida 2 por cento-timolol 0,5 por cento e da associação de dorzolamida 2 por cento com levobunolol 0,5 por cento sobre a pressão intra-ocular (PIO), o diâmetro pupilar (DP), a freqüência cardíaca (FC) e a hiperemia conjuntival em 18 gatos saudáveis. PIO, DP, FC e hiperemia conjuntival foram aferidos diariamente, em três horários distintos (9h, 14h e 18h). Três grupos foram formados (n=6) e um olho de cada animal recebeu, aleatoriamente, uma gota de levobunolol (L), ou a combinação comercial à base de dorzolamida-timolol (DT), ou a associação de dorzolamida com levobunolol (DL). Parâmetros basais foram aferidos no primeiro dia (dia 0). Nos quatro dias consecutivos, os fármacos foram instilados às 8h e 20h e os parâmetros aferidos nos mesmos horários. Todos os parâmetros decresceram significativamente em relação aos valores basais (P<0,001) e não se observou hiperemia conjuntival. O levobunolol reduziu significativamente a PIO, o DP e a FC e o foi o fármaco que mais reduziu a FC. Não se observou efeito sinérgico na redução da PIO quando a dorzolamida foi adicionada ao levobulol.


Sujet(s)
Animaux , Chats , Rythme cardiaque , Pression intraoculaire , Lévobunolol/effets indésirables , Pupille/physiologie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE