Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtre
1.
Arq. bras. oftalmol ; 87(1): e2021, 2024. graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1527824

Résumé

ABSTRACT Purpose: To assess the anterior and posterior segments of full-term neonates over a 1.5-year period. Methods: The findings of full-term neonates who underwent ophthalmological examinations between June 2019 and December 2020 were analyzed, and the results were retrospectively recorded. Results: The study comprised 2972 neonates with a mean birth week of 38.7 ± 1.2 weeks and a mean birth weight of 3235 ± 464 g. The neonates were examined on an average of 49.3 ± 18.9 postnatal days. Of the examined neonates, 185 (6.2%) showed abnormal ophthalmological findings, the most prevalent of which were retinal hemorrhage in 2.3% (n=68) and white changes in the peripheral retina in 1.9% (n=55) of the neonates. Cases of optic disc pathologies (n=20), choroidal nevus (n=10), iris-choroidal coloboma (n=5), subconjunctival hemorrhage (n=6), non-specific retinal pigmentary change (n=4), congenital cataract (n=3), posterior synechia (n=3), iris nevus (n=3), corneal opacity (n=1), choroidal coloboma (n=1), iris coloboma (n=1), buphthalmos (n=1), anophthalmos (n=1), microphthalmia (n=1), lid hemangioma (n=1), and vitreous hemorrhage (n=1) collectively accounted for approximately 2% of all neonates. Pathologies that could potentially impair vision, which were detected by ophthalmological examination, accounted for 1.2% of all neonates (n=37). Conclusion: The most prevalent finding of the ophthalmological examinations of neonates in the present study was retinal hemorrhage. Ophthalmological examinations of neonates can help in identifying diseases that may affect their vision and are curable or may lead to amblyopia in the long term.


RESUMO Objetivo: Avaliar os segmentos anterior e posterior em recém-nascidos a termo durante um período de 1,5 anos. Métodos: Foram analisados recém-nascidos a termo que tiveram os olhos examinados entre junho de 2019 e dezembro de 2020, e os resultados foram registrados retrospectivamente. Resultados: O estudo foi composto por 2.972 recém-nascidos com média de uma semana de nascimento de 38,7 ± 1,2 semanas e um peso médio ao nascer de 3235 ± 464 g. Os recém-nascidos foram examinados em média pós-natal de 49,3 ± 18,9 dias. Dos recém-nascidos, 185 (6,2%) apresentaram resultados oculares anormais. Os achados oculares anormais mais prevalentes foram hemorragia da retina em 2,3% (n=68) e alterações brancas na retina periférica em 1,9% (n=55) dos recém-nascidos. Casos de patologias de disco óptico (n=20), nevo de coroide (n=10), coloboma iris-coroide (n=5), hemorragia subconjuntival (n=6), alteração pigmentar da retina não específica (n=4), catarata congênita (n=3), Sinequia posterior (n=3), nevo da íris (n=3), opacidade da córnea (n=1), coloboma de coroide (n=1), coloboma de íris (n=1), buftalmos (n=1), anoftalmia (n=1), microftalmia (n=1), hemangioma de pálpebra (n=1) e hemorragia vítrea (n=1) contabilizaram coletivamente cerca de 2% dos recém-nascidos. As patologias que potencialmente prejudicam a visão, detectadas por exame ocular, representaram 1,2% dos recém-nascidos (n=37). Conclusão: O achado mais prevalente de exames oculares de recém-nascidos neste estudo foi hemorragia da retina. Exames oftalmológicos em recém-nascidos podem ser úteis na identificação de doenças que podem impactar a visão deles, podendo ser curáveis ou levar à ambliopia no longo prazo.

2.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 40: e2020021, 2022. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1376320

Résumé

ABSTRACT Objective: The main aim of this study was to evaluate the performance of a platform designed for pediatricians to screen amblyopia using a smartphone. Methods: The medical records of consecutive children who received visual screening using a smartphone platform were retrospectively reviewed. The smartphone was used with a flash concentrator case and a software for capturing images of both eyes simultaneously by a photorefraction mechanism. The platform performance was compared to the comprehensive ophthalmological examination, which is considered the gold standard for detecting amblyopia. Sensitivity, specificity, positive predictive value, and negative predictive value of the software in detecting amblyopia risk factors were calculated. Results: A total of 157 children were included, with a mean age of 6.0±.5 years (range 5-7). In 94% of the cases, the software was able to analyze the images and release a result, determining whether or not the child presented with amblyopia risk factors. Compared to the ophthalmological examination, the smartphone platform sensitivity in detecting amblyopia risk factors was 84%, the specificity was 74%, the positive predictive value was 86%, and the negative predictive value was 70%. Conclusions: The sensitivity and specificity of the smartphone photoscreening platform to detect amblyopia risk factors were within the range of traditional instrument-based vision screening technology. A smartphone photorefraction platform appears to be a promising cost-effective alternative to assist pediatricians and minimize obstacles to vision screening and amblyopia detection. Future studies are needed to gather additional comparative data.


RESUMO Objetivo: Avaliar a performance de uma plataforma desenvolvida para pediatras para triagem de ambliopia utilizando um smartphone. Métodos: Os prontuários consecutivos de crianças submetidas a triagem visual usando uma plataforma no smartphone foram analisados retrospectivamente. Uma capa concentradora de flash foi utilizada no smartphone com um software para capturar imagens simultâneas dos dois olhos por um mecanismo de fotorrefração. A performance da plataforma foi comparada ao exame oftalmológico completo, considerado o padrão ouro para detecção de ambliopia. Foram calculados sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do software em detectar fatores de risco para ambliopia. Resultados: Foram incluídas 157 crianças com idade média de 6.0±0.5 anos (variação de 5 a 7 anos). Em 94% dos casos, o software foi capaz de analisar as imagens e fornecer um resultado, determinando se a criança apresentava ou não fatores de risco para ambliopia. Comparados ao exame oftalmológico, a sensibilidade da plataforma no smartphone em detectar fatores de risco para ambliopia foi de 84%, a especificidade foi de 74%, o valor preditivo positivo foi de 86% e o valor preditivo negativo foi de 70%. Conclusões: A plataforma de triagem por fotorrefração usando o smartphone apresentou sensibilidade e especificidade para detectar fatores de risco para ambliopia semelhantes às encontradas em instrumentos tradicionais de triagem por fotorrefração. Uma plataforma no smartphone é uma alternativa custo-efetiva promissora para auxiliar pediatras a minimizar os obstáculos para triagem visual e detecção da ambliopia. Estudos futuros são necessários a fim de reunir dados comparativos adicionais.

3.
Arq. bras. oftalmol ; 83(1): 43-47, Jan.-Feb. 2020. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1088951

Résumé

ABSTRACT Purpose: The aim of this study was to evaluate the effect of anterior chamber depth and axial length on clinical performance of the Spot Vision Screener in detecting amblyopia risk factors in children aged 3-10 years. Methods: A total of 300 eyes from 150 patients aged 3-10 years were prospectively tested with Spot Vision Screener (firmware version 3.0.02.32, software version 3.0.04.06) and a standard autorefractometer (Nidek ARK-1). The anterior chamber depth and axial length were measured with an optical biometer (Nidek AL-Scan). The sensitivity and specificity values for detecting significant refractive errors using the referral criteria of the American Association for Pediatric Ophthalmology and Strabismus were determined. Pearson's correlation analysis was employed to evaluate the relationship between the Spot Vision results and the anterior chamber depth and axial length. Results: Compared with the standard autorefractometer results, the Spot Vision Screener's sensitivity and specificity was 59% and 94%, respectively. The differences between the cycloplegic autorefractometer and the Spot Vision Screener spherical equivalents were negatively correlated with anterior chamber depth (r=-0.48; p<0.001) and axial length (r=-0.45; p<0.001). Conclusion: The Spot Vision Screener has moderate sensitivity and high specificity, using the criteria of the American Association for Pediatric Ophthalmology and Strabismus. The anterior chamber depth and axial length affect the Spot Vision results.


RESUMO Objetivo: O objetivo deste estudo foi avaliar o efeito da profundidade da câmara anterior e do comprimento axial sobre o desempenho clínico do Spot Vision Screener, na deteção de fatores de risco para a ambliopia em crianças de 3 a 10 anos de idade. Métodos: Um total de 300 olhos de 150 pacientes de 3-10 anos de idade foram prospectivamente testados com o Spot Vision Screener (firmware: 3.0.02.32, software: 3.0.04.06) e com autorefratómetro padrão (Nidek ARK-1). Todas as medições de profundidade e comprimento axial da câmara anterior dos pacientes foram realizadas através de Nidek AL Scan. A sensibilidade e especificidade para a deteção de erros refrativos significativos foram determinadas de acordo com os critérios de referência da Associação Americana de Oftalmologia e Estrabismo Pediátricos. A análise da Correlação de Pearson foi utilizada para avaliar a correlação entre os resultados do Spot Vision e a profundidade ou comprimento axial da câmara anterior dos pacientes. Resultados: Em comparação com os resultados do autorefratómetro padrão, a sensibilidade do Spot foi de 59% e a especificidade de 94%. As diferenças entre os equivalentes esféricos do autorefratómetro cicloplégico e o Spot Vision Screener foram correlacionados negativamente com a profundidade (r=-0,48; p<0,001) e o comprimento axial (r=-0,45; p<0,001) da câmara anterior dos casos. Conclusão: O Spot Vision Screener possui uma sensibilidade moderada e uma especificidade elevada utilizando os critérios da Associação Americana de Oftalmologia Pediátrica e Estrabismo; a profundidade da câmara anterior e o comprimento axial dos pacientes afetam os resultados do Spot Vision.


Sujets)
Humains , Enfant d'âge préscolaire , Enfant , Dépistage visuel/instrumentation , Amblyopie/diagnostic , Troubles de la réfraction oculaire/diagnostic , Amblyopie/étiologie , Strabisme , Études prospectives , Facteurs de risque , Sensibilité et spécificité , Rétinoscopie , Longueur axiale de l'oeil , Chambre antérieure du bulbe oculaire
4.
Rev. bras. oftalmol ; 78(5): 321-326, Sept.-Oct. 2019. tab, graf
Article Dans Portugais | LILACS | ID: biblio-1042387

Résumé

Resumo Objetivo: Determinar a concordância do retinógrafo portátil Pictor Plus, na ausência de midríase, com a retinografia digital e avaliar a sua acurácia como método de rastreio da retinopatia diabética (RD). Métodos: Estudo transversal, mascarado para o observador, avaliando 100 olhos de 51 pacientes diabéticos. Foram realizadas retinografias com o Pictor Plus com e sem midríase, seguidos de retinografia convencional com o retinógrafo IMAGEnet por técnico treinado. As imagens obtidas foram analisadas por oftalmologista especialista em retina e classificadas normais, presença de edema macular diabético, retinopatia não proliferativa (inicial, moderada e grave) e retinopatia proliferativa, além de análise inviável. A concordância entre os resultados foi avaliada via coeficiente Kappa. As imagens foram agrupadas em normais e alteradas e estas em RD de alto risco e RD de baixo risco. Avaliou-se ainda a sensibilidade, especificidade, valores preditivos positivos e negativos, em relação à retinografia convencional. Resultados: Oitenta e nove por cento das imagens foram consideradas viáveis para classificação. Pouco mais de 31% dos olhos avaliados foram considerados como normais pelas três tecnologias. O exame com Pictor na ausência de midríase apresentou altos índices de sensibilidade e especificidade para a classificação normal (92,9% e 93,4%) e RD de alto risco (82,9% e 97,9%) e bons resultados para RD de baixo risco (75,0% e 87,0%). Conclusão: O Pictor Plus apresentou altos níveis de concordância com a retinografia digital ao discriminar exames normais de alterados e portadores de RD de baixo e alto risco. Foram verificadas ainda altas sensibilidade e especificidade desta ferramenta, se comparados à retinografia padrão.


Abstract Purpose: Determine the effectiveness of the use a portable handheld fundus camera as a screening method for diabetic retinopathy, compared to regular digital retinography. Methods: This is a cross-sectional, observer-masked study, evaluating 100 eyes of 51 diabetic patients undergoing a routine dilated retinography for diabetic retinopathy. Fundus images pre and post-dilation we captured by Pictor Plus (Volk Optical Inc., Mentor, USA), followed by routine digital retinography by IMAGEnet (Topcon Medical Systems, New Jersey, USA). All exams were performed by a trained technician on the same occasion. The images were analyzed and graded by a masked retina specialist and classified as normal, presence of diabetic macular edema, nonproliferative diabetic retinopathy (initial, moderate and severe) and proliferative diabetic retinopathy. The ungradable images were recorded and excluded from analyses. The agreement between results obtained by the three methods was evaluated via Kappa coefficient. Sensitivity, specificity, positive and negative predictive values in relation to IMAGEnet images were also determined. Results: Images were gradable in 89% of pre-dilation photos. Pictor Plus pre-dilation images had high sensitivity and specificity in identifying normal eyes (92.9% and 93.4%) and in vision-threatening DR (82.9% and 97.9%) both when compared to IMAGEnet results. Conclusion: Pictor can capture retinal images of sufficient quality to screen for DR with and without dilation. Single retinal images obtained using Pictor can identify eyes with vision-threatening DR with high sensitivity and specificity compared to routine IMAGEnet images.


Sujets)
Humains , Photographie (méthode)/instrumentation , Télémédecine/instrumentation , Rétinopathie diabétique/imagerie diagnostique , Techniques de diagnostic ophtalmologique/instrumentation , Rétine/imagerie diagnostique , Traitement d'image par ordinateur , Pupille/effets des médicaments et des substances chimiques , Dépistage visuel , Cécité/étiologie , Études transversales , Rétinopathie diabétique/complications , Mydriatiques
5.
Rev. panam. salud pública ; 42: e61, 2018. tab
Article Dans Anglais | LILACS | ID: biblio-961794

Résumé

ABSTRACT Objective. To assess the impact of efforts to reduce visual impairment by detecting and treating refractive errors (REs) among schoolchildren in two urban areas of Chile. Methods. In 2013, in the communities of Concepción and La Florida, we conducted a multicenter, multistage-sampling, cross-sectional study employing methods used by the Refractive Error Study in Children (RESC) survey. Best-corrected visual acuity was assessed using pinhole, with and without glasses. The coverage for correcting visual impairment due to refractive error was estimated. Results. We examined 5 412 schoolchildren, in the communities of Concepción (n = 3 049) and La Florida (n = 2 363). Uncorrected visual acuity (VA) of > 0.63 in at least one eye was found in 4 721 children (87.23%; 95% confidence interval (CI): 86.58%-88.30%). Of the remaining children, 1 017 of them (18.79%; 95% CI: 17.78%-19.80%) had a VA of < 0.5 in at least one eye. Of the 691 children with uncorrected visual impairment with both eyes open (12.77%; 95% CI: 11.9%-13.64%), 476 of them (8.76%; 95% CI: 8.03%-9.49%) achieved normal vision using best possible correction, and with 271 of the 476 (56.93%) having a normal presenting VA in the better eye. Conclusions. We found an increased coverage of services for RE-associated visual impairment and an increased percentage of children wearing glasses as compared to values reported for La Florida in an article published in 2000. The National Board of School Aid and Scholarships (JUNAEB) in Chile is achieving better results in its schoolchildren eye care program.


RESUMEN Objetivo. Evaluar la repercusión de las medidas para reducir la deficiencia visual mediante la detección y el tratamiento de los errores refractivos en escolares de dos zonas urbanas de Chile. Métodos. En el 2013, en las comunas de Concepción y La Florida, realizamos un estudio transversal multicéntrico, con muestreo en varias etapas, con los métodos del estudio de error refractivo en niños conocido como RESC por su sigla en inglés. La agudeza visual mejor corregida se evaluó con un agujero estenopeico, con y sin lentes. Se calculó la cobertura de la corrección de las deficiencias visuales secundarias a errores de refracción. Resultados. Examinamos a 5 412 escolares en las comunidades de Concepción (n = 3 049) y La Florida (n = 2 363). Se encontró una agudeza visual sin corrección >0,63 cuando menos en un ojo en 4 721 niños (87,23%; intervalo de confianza de 95% [IC]: 86,58%-88,30%). De los niños restantes, 1 017 (18,79%; IC de 95%: 17,78%-19,80%) tenían una agudeza visual <0,5 cuando menos en un ojo. De los 691 niños con deficiencia visual sin corrección con ambos ojos abiertos (12,77%; IC de 95%: 11,9%-13,64%), 476 niños lograron la visión normal con la mejor corrección posible (8,76%; IC de 95%: 8,03%-9,49%); 271 de estos 476 (56,93%) tenían agudeza visual normal en el ojo mejor al inicio. Conclusiones. Encontramos una mayor cobertura de los servicios para la deficiencia visual secundaria a errores refractivos y un mayor porcentaje de niños que usaban lentes en comparación con los valores notificados para La Florida en un artículo publicado en el 2000. La Junta Nacional de Auxilio Escolar y Becas (JUNAEB) de Chile está logrando mejores resultados en su programa de atención oftalmológica para los escolares.


RESUMO Objetivo. Avaliar o impacto dos esforços para reduzir a baixa visão ao detectar e tratar erros de refração em escolares em duas áreas urbanas do Chile. Métodos. Foi realizado um estudo transversal multicêntrico com amostragem em múltiplos estágios, com a aplicação da metodologia do Estudo de erros de refração em crianças (RESC), nas comunidades de Concepción e La Florida em 2013. A melhor acuidade visual corrigida foi avaliada com fenda estenopeica, com e sem óculos. Foi estimada a cobertura para corrigir a visão por erros de refração. Resultados. Foram examinados 5.412 escolares nas comunidades de Concepción (n = 3.049) e La Florida (n = 2.363). Acuidade visual (AV) não corrigida >0,63 em pelo menos um olho foi observada em 4.721 crianças (87,23%; intervalo de confiança de 95% [IC]: 86,58%-88,30%). Do restante, 1.017 crianças (18,79%; IC de 95%: 17,78%-19,80%) apresentaram AV <0,5 em pelo menos um olho. Das 691 crianças com baixa visão não corrigida medida com ambos os olhos abertos (12,77%; IC de 95%: 11,9%-13,64%), 476 (8,76%; IC de 95%: 8,03%-9,49%) atingiram visão normal com a melhor correção visual possível e, destas, 271 (56,93%) tiveram AV normal no melhor olho. Conclusões. Foi observado um aumento da cobertura dos serviços para baixa visão associada a erros de refração e um aumento na porcentagem de crianças usando óculos quando comparado aos dados informados na comunidade La Florida em artigo publicado em 2000. A comissão nacional chilena de auxílio escolar e bolsas de estudos (JUNAEB) está conseguindo obter resultados melhores com o programa de atenção à saúde ocular de escolares.


Sujets)
Humains , Troubles de la réfraction oculaire , Dépistage visuel , Observance par le patient , Étudiants , Chili , Lunettes correctrices
6.
Rev. bras. oftalmol ; 75(4): 296-299, July-Aug. 2016. tab, graf
Article Dans Portugais | LILACS | ID: lil-794869

Résumé

RESUMO Objetivo: Comparar a sensibilidade ao contraste nas faixas etárias de 20 a 25, 40 a 45 e acima de 60 anos de idade. Métodos: Realizou-se um estudo transversal com indivíduos de diferentes idades, com acuidade visual superior a 20/25, sem doença ocular e sem cirurgia oftalmológica prévia. A acuidade visual foi medida pelo teste de Snellen e, a sensibilidade ao contraste, pelo aparelho OPTEC 3500P(r). A análise estatística foi realizada pelo teste de Wilcoxon, considerando um intervalo de confiança de 95%. Resultados: Em relação aos pacientes de 20 a 25 anos, os de 40 a 45 anos não apresentaram diminuição significativa da sensibilidade ao contraste em nenhuma das frequências espaciais avaliadas. Comparando os pacientes acima de 60 anos aos de 40 a 45 anos, houve diminuição da sensibilidade ao contraste nas frequências de 6,0 a 18,0 cpg no modo diurno e de 3,0 a 18,0 cpg no noturno. Já quando comparados aos de 20 a 25 anos, os pacientes maiores de 60 anos mostraram diminuição nas frequências de 3,0 a 18 cpg no modo diurno e em todas as frequências no modo noturno. Conclusão: A função de sensibilidade ao contraste parece diminuir com a idade, após os 45 anos, principalmente nas médias e altas frequências espaciais. Isso pode impactar na leitura, na direção e na mobilidade, dentre outras atividades diárias.


ABSTRACT Objective: To compare contrast sensitivity in different age groups: 20 to 25, 40 to 45 and above 60 years old. Methods: We performed a cross sectional study with individuals of different ages, with visual acuity better than 20/25, without eye disease and without prior eye surgery. Visual acuity was measured by Snellen test and contrast sensitivity was evaluated by OPTEC 3500P(r) equipment. Statistical analysis was performed using Wilcoxon test, considering a 95% confidence interval. Results: Compared to patients between 20 and 25 years old, patients between 40 and 45 years old did not presented decreased contrast sensitivity in any of evaluated frequencies. When compared to patients between 40 and 45 years old, patients over 60 years old presented decrease in contrast sensitivity at frequencies of 6,0 to 12,0 cpg in diurnal mode and 3,0 to 18,0 cpg in nocturnal mode. But when compared to patients between 20 and 25 years, patients older than 60 years old showed contrast sensitivity decreased in the frequencies of 3,0 to 18 cpg in diurnal mode and at all frequencies in nocturnal mode. Conclusion: Contrast sensitivity seems to decrease with age, after 45 years old, especially in middle and high spatial frequencies. This condition may affect reading, direction and mobility, as well as other daily activities.

7.
Arq. bras. oftalmol ; 69(6): 907-914, nov.-dez. 2006. ilus, tab, graf
Article Dans Portugais | LILACS | ID: lil-440431

Résumé

OBJETIVO: Elaborar e validar teste computadorizado para medida da acuidade visual de escolares. MÉTODOS: Foi elaborado teste computadorizado para determinação da acuidade visual utilizando os padrões das tabelas logarítmicas impressas adotadas na clínica oftalmológica. Foram avaliados 90 alunos da primeira série do ensino básico, oito estudantes do curso de Tecnologia Oftálmica da UNIFESP-EPM e 10 pacientes do ambulatório de Estrabismo do Departamento de Oftalmologia da UNIFESP-EPM. Todos os sujeitos foram avaliados pelo mesmo examinador e submetidos ao exame de acuidade visual monocular, pela tabela logarítmica de optotipos E impressa e do novo teste computadorizado no mesmo momento. Os participantes forneceram os seus consentimentos após esclarecimento. RESULTADOS: As análises estatísticas revelaram correlação excelente (r>0,75) entre os dois métodos, apesar da leve tendência apresentada pelo teste computadorizado em superestimar a acuidade visual quando comparado com o padrão-ouro. O teste computadorizado apresentou sensibilidade de 100 por cento e especificidade de 94 por cento. CONCLUSÕES: Os resultados obtidos nos permitem dizer que o teste computadorizado pode ser utilizado como novo recurso para triagem da qualidade visual dos escolares, por ser método rápido, de fácil aplicação, barato, automático e atrativo para as crianças. A automatização desvincula o aplicador da interpretação das respostas dadas pelo aluno testado, garante padronização do procedimento, que favorece as análises de acompanhamento e pode ser realizado por diferentes examinadores. Para melhor compreensão da efetividade do teste como instrumento de triagem visual, seria interessante instituí-lo nas escolas do curso básico, após treinamento dos professores para sua aplicação.


PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity assessment with optotypes arranged as those of printed logarithmic charts used in ophthalmic clinic. Ninety seven-year-old students, 8 normal adult volunteers and 10 patients from the Strabismus sector of the Federal University of São Paulo were evaluated by the same examiner and submitted to the visual acuity test through printed visual acuity logarithmic tumble "E" chart and the new computerized test at the same time. Written consent was obtained after clarification about the research project. RESULTS: Statistical analysis showed excellent correlation between the two methods (r>0.75) besides the slight trend of the computerized test to overestimate visual acuity when compared with the gold standard. Sensitivity of the computerized test was 100 percent (correctly identified 6 eyes with poor visual acuity) and specificity was 94 percent. CONCLUSION: The computerized test can be used as a new clinical tool for visual acuity screening of school-age children and it is fast, easy to perform and inexpensive, besides being more attractive for children. The method releases the examiner from the interpretation of the subject's answers and ensures the procedure's standardization even when more than one examiner performs the test. To better understand the effectiveness of this method for visual screening, one option would be to introduce it in elementary schools, after training the teachers to perform this test.


Sujets)
Humains , Mâle , Femelle , Enfant , Adolescent , Adulte , Diagnostic assisté par ordinateur/normes , Troubles de la vision/diagnostic , Dépistage visuel/normes , Tests de vision/méthodes , Acuité visuelle/physiologie , Interprétation statistique de données , Diagnostic assisté par ordinateur/économie , Diagnostic assisté par ordinateur/méthodes , Mathématiques , Reproductibilité des résultats , Sensibilité et spécificité , Strabisme , Perception de la taille/physiologie , Troubles de la vision/prévention et contrôle , Dépistage visuel/économie , Dépistage visuel/méthodes
SÉLECTION CITATIONS
Détails de la recherche