1.
Article de Anglais | WPRIM | ID: wpr-97070

RÉSUMÉ

PURPOSE: To evaluate the axial displacement of implant-abutment assembly after cyclic loading in internal tapered connection system. MATERIALS AND METHODS: External butt-joint connection implant and internal tapered connection implant were connected with three types of abutment for cement-retained prostheses, i.e. external type abutment (Ext group), internal tapered 1-piece abutment (Int-1 group), and internal tapered 2-piece abutment (Int-2 group). For each group, 7 implants and abutments were used. The implantabutments assemblies were clamped into the implant holder for vertical loads. A dynamic cyclic loading was applied for 150 +/- 10 N at a frequency of 4 Hz. The amount of axial displacement of the abutment into the implant was calculated at each cycle of 0, 5, 10, 50, 100, 1,000, 5,000, and 10,000. A repeated measures analysis of variance (ANOVA) for the overall effect of cyclic loading and the pattern analysis by linear mixed model were used for statistical analysis. Differences at P<.05 were considered statistically significant. RESULTS: The mean axial displacement after 10,000 cycles were 0.714 +/- 0.488 microm in Ext group, 5.286 +/- 1.604 microm in Int-1 group, and 11.429 +/- 1.902 microm in Int-2 group. In the pattern analysis, Int-1 and Int-2 group showed continuous axial displacement at 10,000 cycles. There was no declining pattern of axial displacement in the Ext group. CONCLUSION: The pattern of linear mixed model in Ext group showed no axial displacement. There were continuous axial displacements in abutment-implant assemblies in the Int-1 and Int-2 group at 10,000 cycles. More axial displacement was found in Int-2 group than in Int-1 group.


Sujet(s)
Conception d'implant dentaire et de pilier , Projets pilotes , Prothèses et implants
2.
Article de Coréen | WPRIM | ID: wpr-229224

RÉSUMÉ

PURPOSE: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. MATERIALS AND METHODS: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with 0degreesangle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison. RESULTS: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups(P<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. CONCLUSION: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.


Sujet(s)
Alliages , Axis , Cimentation , Moment de torsion
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE