Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 518
Filtre
1.
Cancer Research and Clinic ; (6): 228-233, 2023.
Article Dans Chinois | WPRIM | ID: wpr-996216

Résumé

With the continuous development of endoscopic technology, more and more early-stage colorectal cancer and precancerous lesions have been found by endoscopy, and endoscopic treatment has dominated the treatment of early-stage colorectal cancer for its characteristics of small trauma, rapid recovery and good effect. At present, there are many methods of endoscopic treatment, but their indications are still controversial, and some new technologies still need further verified. Based on the latest guidelines at home and abroad and some hot issues, this article reviews the progress of endoscopic treatment of early-stage colorectal cancer and precancerous lesions, mainly including the indications of various endoscopic treatment methods, some important technical improvement of endoscopic treatment methods, and the application of some new endoscopic treatment technologies, in order to provide some references for the minimally invasive treatment of early-stage colorectal cancer and precancerous lesions.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 518-522, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992742

Résumé

Minimally invasive treatment is the development trend in surgical techniques for pelvic fractures. There have been numerous minimally invasive techniques for pelvic fractures, each having its own advantages. This paper reviews the literature recently published at home and abroad concerning minimally invasive treatment of pelvic fractures so as to summarize the existing minimally invasive techniques for the fractures and their supporting theories, hoping traumatic orthopedists to know more about the minimally invasive techniques. As a result, Chinese traumatic orthopedists may formulate personalized treatment protocols to suit the specific condition of each patient so that the surgical invasion can be minimized and the intraoperative and postoperative complications reduced.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 505-511, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992740

Résumé

Objective:To investigate the feasibility and clinical efficacy of percutaneous anterior column screwing assisted by blocking screws for pelvic and acetabular fractures.Methods:A retrospective analysis was conducted of the 13 patients who had been admitted from July 2019 to April 2022 for pelvic and acetabular fractures. There were 8 males and 5 females with an age of (49.1±13.3) years, 7 acetabular fractures (6 on one side and 1 on both sides; by the Letournel-Judet classification: 5 anterior column fractures on 6 sides, and 2 transverse and posterior wall fractures on 2 sides), and 6 pelvic fractures (5 complicated with pelvic posterior ring fracture; by the Tile classification: 1 case of type B2, 3 cases of type C1, and 2 cases of type C2). According to the anatomic zones of the anterior column, 5 fractures were at zone Ⅲ, 3 ones at zone Ⅳ, and 6 ones at zone Ⅴ. The time from injury to surgery ranged from 3 to 14 days, averaging (8.2±2.9) days. Anterograde anterior column screwing assisted by blocking screws was performed for all the 13 patients; the posterior ring was fixated with percutaneous sacroiliac joint screws for the 5 patients complicated with pelvic posterior ring fracture. The surgical time, intraoperative fluoroscopy frequency, and intraoperative bleeding volume for insertion of anterior column screws, fracture reduction quality, and hip joint function at the last follow-up were recorded.Results:A total of 14 anterior column screws were inserted percutaneously in the 13 patients. For insertion of anterior column screws, the surgical time was (65.0±10.2) min, the intraoperative fluoroscopy frequency (63.5±14.5) times, and the intraoperative bleeding volume for each screw less than 30 mL. All the incisions healed primarily after surgery, without such complications as iatrogenic neurovascular injury or poor wound healing. All the 13 patients were followed up for (11.1±2.2) months after surgery. In the patient with bilateral acetabular anterior column fractures for which 2 anterior column screws had been inserted, one screw had to be removed due to its displacement at 1 month after surgery; no such complications as loosening of internal fixation or fracture re-displacement was found in the other patients. All fractures healed after (10.2±2.1) months. According to the Matta scoring for quality of fracture reduction, 7 sides were excellent, 5 sides good, and 2 sides poor; according to the Majeed scoring for the 6 patients with pelvic fracture at the last follow-up, the efficacy was rated as excellent in 4 cases and as good in 2 ones; according to the modified Merle d'Aubigné & Postel scoring for the 7 patients with 8 acetabular fractures at the last follow-up, the efficacy was rated as excellent in 4 hips, as good in 3 hips, and as fair in 1 hip.Conclusion:For pelvic and acetabular fractures, minimally invasive percutaneous anterior column screwing assisted by blocking screws can result in fine clinical efficacy, in addition to its easy procedures, safety and reliability.

4.
Chinese Journal of Orthopaedic Trauma ; (12): 491-497, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992738

Résumé

Objective:To explore the clinical efficacy of a retrograde pubic ramus intramedullary nail (RPRIN) in the treatment of anterior pelvic ring fractures.Methods:A retrospective study was conducted to analyze the 14 patients with anterior pelvic ring fracture who had been treated and followed up at Department of Traumatic Surgery, Tongji Hospital From June 2020 to February 2021. There were 10 males and 4 females with an age of (44.8±12.5) years. By the AO/OTA classification for pelvic fractures, 5 cases were type 61-A, 4 cases 61-B, and 5 cases type 61-C; by the Nakatani classification, 1 case belonged to unilateral zone Ⅰ fracture, 5 cases to unilateral zone Ⅱ fracture, 2 cases to unilateral zone Ⅲ fracture, 3 cases to right zone Ⅱ and left zone Ⅲ fracture, 2 cases to zone Ⅲ fracture on both left and right sides, and 1 case to zone Ⅱ fracture on both sides. The time from injury to operation was (7.8±1.8) days. All the anterior pelvic ring fractures were fixated with a RPRIN. The time and fluoroscopic frequency for placement of every single RPRIN, quality of fracture reduction, and pelvic function and incidence of postoperative complications at the last follow-up were recorded.Results:A total of 18 RPRINs were placed in the 14 patients. For placement of each RPRIN, the time was (35.9±8.6) min, and the fluoroscopic frequency (22.8±1.9) times. No complications such as infection occurred at any surgical incision after RPRIN placement. According to the Matta scoring, the quality of postoperative fracture reduction was assessed as excellent in 7 cases, as good in 5 cases and as fair in 2 cases. The 14 patients were followed up for (18.1+1.5) months. Their X-ray and CT images of the pelvis at the last follow-up showed that the fractures healed well and the intramedullary nails were placed in the cortical bone of the anterior ring of the pelvis. According to the Majeed scoring at the last follow-up, the pelvic function was assessed as excellent in 10 cases, as good in 3 cases and as fair in 1 case. One patient reported discomfort during squatting 2 months after operation but the symptom improved 3 months later without any special treatment. No patient experienced such complications as displacement or slippage of RPRIN, or pain at the insertion site.Conclusion:RPRIN is effective in the treatment of anterior pelvic ring fractures, showing advantages of small surgical incision, limited intraoperative fluoroscopy and short operation time.

5.
Chinese Journal of Orthopaedic Trauma ; (12): 415-421, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992727

Résumé

Objective:To compare the clinical effects between proximal humerus internal locking system (PHILOS) inverted and a posterior single plate in the anterior percutaneous minimally invasive internal fixation for distal humeral shaft fractures.Methods:A retrospective study was conducted to analyze the data of 65 patients with distal humeral shaft fracture who had been treated from January 2018 to May 2021 at Department of Orthopaedics, The Second Hospital of Fuzhou. The patients were assigned into 2 groups according to different treatment methods. In the observation group of 30 cases subjected to anterior percutaneous minimally invasive internal fixation with PHILOS inverted: 20 males and 10 females with an age of (41.5±11.6) years; type A in 5 cases, type B in 14 cases, and type C in 11 cases by AO fracture classification. In the control group of 35 cases subjected to anterior percutaneous minimally invasive internal fixation with a posterior single plate: 23 males and 12 females with an age of (39.9±11.2) years; type A in 7 cases, type B in 17 cases, and type C in 11 cases by AO fracture classification. The preoperative general data, operation time, intraoperative blood loss, total incision length, fracture healing time, and shoulder and elbow VAS scores, Constant-Murley shoulder function score, Mayo elbow performance score (MEPS), and complications at the last follow-up were recorded and compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). There were no significant differences either in operation time, fracture healing time, or shoulder or elbow VAS pain score, Constant-Murley shoulder function score, or MEPS at the last follow-up between the 2 groups ( P>0.05). The intraoperative blood loss was (59.7±26.6) mL in the observation group and (165.7±86.4) mL in the control group, and the total incision length was (10.7±2.1) cm in the observation group and (18.6±2.7) cm in the control group, showing statistically significant differences between the 2 groups ( P<0.01). There was no injury to the radial nerve or musculocutaneous nerves, incision infection or fracture nonunion in the observation group. There were 4 cases of iatrogenic radial nerve injury, 2 cases of incision infection and 1 case of fracture nonunion in the control group, yielding a complication rate of 20.0% (7/35). The difference in the incidence of complications was significant between the 2 groups ( P<0.01). Conclusion:In the treatment of distal humeral shaft fracture with anterior percutaneous minimally invasive internal fixation, PHILOS inverted has advantages of less soft tissue damage, less intraoperative bleeding, and a lower risk of iatrogenic radial nerve injury than the posterior single plate.

6.
Chinese Journal of Orthopaedic Trauma ; (12): 341-350, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992717

Résumé

Objective:To compare the short-term efficacy between our self-designed intelligent robot-assisted minimally invasive reduction system and conventional freehand reduction assisted by fluoroscopy in the treatment of unstable pelvic fractures by robot or fluoroscopy-assisted internal fixation with percutaneous screws.Methods:A prospective randomized controlled trial was conducted to include eligible 35 patients with unstable pelvic fracture who were admitted to Department of Orthopaedic Trauma, Beijing Jishuitan Hospital from December 2021 to October 2022. They were randomized into 2 groups. The observation group[17 cases, 10 males and 7 females with an age of (44.0±17.4) years] was treated with robot-assisted minimally invasive reduction, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws; the control group[18 cases, 12 males and 6 females with an age of (38.8±15.0) years] was treated with freehand reduction assisted by fluoroscopy, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws. The 2 groups were compared in terms of operation time, intraoperative bleeding, successful reduction, reduction quality, incidence of surgical complications and postoperative functional scores.Results:The 2 groups were comparable because there were no significant differences in the preoperative general data between them ( P>0.05). The intraoperative fluoroscopy frequency[(32.4±17.5) times] and fluoroscopy time [(19.8±10.4) s] in the observation group were significantly lower or shorter than those in the control group [(60.8±26.6) times and (38.2±16.1) s], and the rate of successful reduction in the observation group was 100.0% (17/17), significantly higher than that in the control group[72.2% (13/18)] ( P<0.05). There was no significant difference between the 2 groups in intraoperative bleeding, operation time, reduction error, excellent and good rate of reduction after operation by Matta scoring, or Majeed functional score at 12 weeks after operation ( P>0.05). Conclusion:In the treatment of unstable pelvic fractures, since our self-designed intelligent robot-assisted minimally invasive reduction system can plan autonomously the reduction paths and accomplish minimally invasive reduction of the fracture with 3D images real-time monitoring, it is advantageous over conventional reduction methods in a higher success rate and less radiation exposure.

7.
International Journal of Surgery ; (12): 433-436, 2023.
Article Dans Chinois | WPRIM | ID: wpr-989477

Résumé

In recent years, with the development and maturity of endoscopic technique, endoscopic spinal surgery represented by water media and optical rigid endoscope has been widely used in the treatment of many disorders in the cervical, thoracic and lumbar spine. Endoscopic spinal surgery shows similar clinical effects as traditional open surgery or other minimally invasive procedures, and is favored by spinal surgeons due to its advantages of less trauma and rapid recovery after surgery. However, the large-scale application of endoscopic technique brings problems such as non-standard nomenclature and unreasonable indications. Therefore, this article will summarize the surgical nomenclature and indications of endoscopic spinal surgery, in order to provide a reference for spinal surgeons to understand and apply endoscopic technology reasonably.

8.
China Journal of Orthopaedics and Traumatology ; (12): 414-419, 2023.
Article Dans Chinois | WPRIM | ID: wpr-981707

Résumé

OBJECTIVE@#To compare the short-term clinical efficacy and radiologic differences between oblique lateral interbody fusion(OLIF) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for degenerative lumbar spondylolisthesis.@*METHODS@#A retrospective analysis was performed on 58 patients with lumbar spondylolisthesis treated with OLIF or MIS-TLIF from April 2019 to October 2020. Among them, 28 patients were treated with OLIF (OLIF group), including 15 males and 13 females aged 47 to 84 years old with an average age of (63.00±9.38) years. The other 30 patients were treated with MIS-TLIF(MIS-TLIF group), including 17 males and 13 females aged 43 to 78 years old with an average age of (61.13±11.10) years. General conditions, including operation time, intraoperative blood loss, postoperative drainage, complications, lying in bed, and hospitalization time were recorded in both groups. Radiological characteristics, including intervertebral disc height (DH), intervertebral foramen height (FH), and lumbar lordosis angle (LLA), were compared between two groups. The visual analogue scale (VAS) and Oswestry disability index (ODI) were used to evaluate the clinical effect.@*RESULTS@#The operation time, intraoperative blood loss, postoperative drainage, lying in bed, and hospitalization time in OLIF group were significantly less than those in the MIS-TLIF group (P<0.05). The intervertebral disc height and intervertebral foramen height were significantly improved in both groups after the operation (P<0.05). The lumbar lordosis angle in OLIF group was significantly improved compared to before the operation(P<0.05), but there was no significant difference in the MIS-TLIF group before and after operation(P>0.05). Postoperative intervertebral disc height, intervertebral foramen height, and lumbar lordosis were better in the OLIF group than in the MIS-TLIF group (P<0.05). The VAS and ODI of the OLIF group were lower than those of the MIS-TLIF group within 1 week and 1 month after the operation (P<0.05), and there were no significant differences in VAS and ODI at 3 and 6 months after the operation between the two groups(P>0.05). In the OLIF group, 1 case had paresthesia of the left lower extremity with flexion-hip weakness and 1 case had a collapse of the endplate after the operation;in the MIS-TLIF group, 2 cases had radiation pain of lower extremities after decompression.@*CONCLUSION@#Compared with MIS-TLIF, OLIF results in less operative trauma, faster recovery, and better imaging performance after lumbar spine surgery.


Sujets)
Mâle , Femelle , Humains , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Adulte , Études rétrospectives , Spondylolisthésis/chirurgie , Vertèbres lombales/chirurgie , Lordose/chirurgie , Interventions chirurgicales mini-invasives/méthodes , Arthrodèse vertébrale/méthodes , Résultat thérapeutique , Perte sanguine peropératoire , Hémorragie postopératoire
9.
Chinese Journal of Ocular Fundus Diseases ; (6): 261-264, 2022.
Article Dans Chinois | WPRIM | ID: wpr-934303

Résumé

Silicone oil is widely used in intraocular filling of fundus disease after vitrectomy, which improves retinal reattachment rate andpostoperative visual function of patients. With the era of minimally invasive vitreous surgery coming, the utilization rate of silicone oil filling is decreasing, however, it still plays an indispensable role in the surgical treatment of complex fundus diseases. In the process of using silicone oil, the indications should be strictly selected, and the potential risks should be fully considered and possibly avoided. The study of vitreous substitutes with certain physiological functions is currently a research hotspot in the field of fundus diseases.

10.
Chinese Journal of Ocular Fundus Diseases ; (6): 257-260, 2022.
Article Dans Chinois | WPRIM | ID: wpr-934302

Résumé

At present, tamponade agent which being used in retinal surgery is mainly sterile air, gas and silicone oil. Sterile air is mostly used in the treatment of simple retinal detachment. Gas or silicone oil as tamponade is greatly applied for complicated retinal detachment. In recent years, with the application of micro-invasive vitrectomy under a wide-angle viewing system and perioperative anti-vascular endothelial growth factor drugs, application of intraocular filling materials also has changed. The application of silicone oil is significantly reduced. Percentage rate of gas as tamponade for retinal detachment is reduced. The application of sterile air as tamponade is rising. With selecting indication carefully and picking up the suitable air or gas, doctor will reduce the workload. It will also reduce the social burden and benefit patients.

11.
Chinese Journal of Ocular Fundus Diseases ; (6): 34-39, 2022.
Article Dans Chinois | WPRIM | ID: wpr-934270

Résumé

Objective:To observe the changes of macular morphology and blood flow after minimally invasive vitrectomy (PPV) in patients with severe non-proliferative diabetic retinopathy (sNPDR).Methods:A prospective clinical study. From January 2020 to April 2021, 17 consecutive sNPDR patients with 17 eyes who were diagnosed and received PPV treatment at the Zhongshan Ophthalmic Center of Sun Yat-sen University were included in the study. There were 12 males with 12 eyes and 5 females with 5 eyes; the average age was 55 years old; the average duration of diabetes was 11 years; the average glycosylated hemoglobin was 7.9%. Before the operation and 1, 3, and 6 months after the operation, all the affected eyes underwent best corrected visual acuity (BCVA), standard 7-field fundus color photography, and optical coherence tomography angiography (OCTA). An OCTA instrument was used to scan the macular area of the affected eye with in the range of 3 mm×3 mm to measure the central subfoveal thickness (CST), the thickness of the ganglion cell complex (GCC) in the macular area, the thickness of the retinal nerve fiber layer (RNFL), and the superficial capillary plexus (SCP) vessel density and perfusion density in the macular area, macular avascular zone (FAZ) area, a-circularity index (AI). Before the operation and 6 months after the operation, the least significant difference test was used for the pairwise comparison.Results:Before the operation, 1, 3, and 6 months after the operation, the FAZ area of the macular area were 0.34±0.14, 0.35±0.10, 0.37±0.10, 0.36±0.13 mm 2, respectively; AI were 0.52±0.13, 0.54±0.11, 0.57±0.10, 0.60±0.11; CST was 282.6±66.7, 290.4±70.9, 287.2±67.5, 273.2± 49.6 μm; GCC thickness were 77.1±15.5, 74.3±13.9, 72.6±16.2, 78.5±18.3 μm; the thickness of RNFL was 97.9±13.8, 101.3±14.6, 97.7±12.0, 96.1±11.4 μm, respectively. The overall blood flow density of SCP in the macula were (16.79±1.43)%, (16.71±1.82)%, (17.30±2.25)%, (17.35±1.22)%; the overall perfusion density were 0.32±0.02, 0.32±0.03, 0.33±0.03, 0.33±0.02, respectively. After the operation, the CST increased first and then decreased; the thickness of RNFL increased 1 month after the operation, and then gradually decreased. Comparison of the parameters before and 6 months after the operation showed that the AI improved, and the difference was statistically significant ( P=0.049); the difference in FAZ area and the thickness of CST, GCC, and RNFL was not statistically significant ( P=0.600, 0.694, 0.802, 0.712); There was no statistically significant difference in the retina SCP blood flow density and perfusion density in the macular area ( P=0.347, 0.361). Conclusion:Compared with before surgery, there is no significant change in macular structure and blood flow density in sNPDR patients within 6 months after minimally invasive PPV.

12.
Chinese Journal of Ocular Fundus Diseases ; (6): 1-5, 2022.
Article Dans Chinois | WPRIM | ID: wpr-934265

Résumé

Vitrectomy is the preferred surgical method for diabetic retinopathy, especially in the stage of proliferative diabetic retinopathy. Vitrectomy for diabetic retinopathy involves all aspects of vitrectomy, which is one of the signs of maturity of retinal surgeons. With the application of minimally invasive vitrectomy and perioperative anti-neovascularization drugs, indications and timing of surgery, perioperative medication, management of vitreous, and whether combined with cataract surgery have changed greatly, and new understanding is needed. Evidence-based clinical research on the timing of diabetic retinopathy surgery and perioperative drug use should be carried out to provide a new theoretical basis for the surgical treatment of diabetic retinopathy.

13.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 18-22, 2022.
Article Dans Chinois | WPRIM | ID: wpr-934209

Résumé

Objective:To investigate the surgical procedure and outcome of uniportal thoracoscopic decortication in the treatment of chronic tuberculous empyema.Methods:From March 2019 to December 2019, the clinical data of 53 patients with chronic tuberculous empyema, who underwent uniportal thoracoscopic decortication in the Surgical Department of Wuhan Pulmonary Hospital were retrospectively analyzed. There were 40 males and 13 females. Age ranged from 16 to 69, averaged 36 years old.36 cases were on the right side and 17 cases on the left side, 38 cases were complicated with pulmonary tuberculosis. All cases had been diagnosed as tuberculous empyema by pathogeny and pathology test in preoperative or postoperative, and received tuberculosis management treatment between 2 and 12 months prior to surgery.The surgical procedure and clinical efficacy of uniportal thoracoscopic decortication were expounded in treatment of chronic tuberculous empyema.Results:Among the 53 patients, 49(92.45%) cases underwent uniportal thoracoscopic decortication, and 4(7.55%) cases changed to thoracotomy. The duration of surgery was 100-370 min, mean(234.53±56.06)min. Intraoperative hemorrhage was 50-1 400 ml, median value 300(175.0, 402.5)ml. Catheter retention time was 3-22 days, median value 8(6.00, 11.25)days. The incidence of surgical complications was 1.89%(1/53), the cure rate was 92.45%(49/53).Conclusion:If the perioperative evaluation and treatment are appropriate, and the operator is experienced, the uniportal thoracoscopic decortication is feasible, safe and effective in the therapy of chronic tuberculous empyema.

14.
Chinese Journal of General Surgery ; (12): 35-38, 2022.
Article Dans Chinois | WPRIM | ID: wpr-933608

Résumé

Objective:To analyze the effectiveness and safety of Morinidazole combined laparoscopic appendectomy for acute purulent appendicitis and acute gangrene appendicitis.Methods:We retrospectively retrieved 387 acute appendicitis patients who have received surgery or conservative treatment from Jan 2017 to Jun 2019. Firty four patients with Morinidazole + Etimicin bigeminy combined laparoscopic surgery were set to experimental group. The other 54 cases using ornidazole + levofloxacin bigeminy combined laparoscopic appendectomy were enrolled into control group after Propensity Score Matching.Results:After 1∶1 propensity score matching, there was no statistically significant difference between the two groups and control group in clinical features. The white blood cell count, C-reactive protein and calcitonin original inflammation index change were higher in experimental group than in the control group,both preoperatived and on post-op day1 and day 3 (all P<0.05). In the experimental group the length of hospital stay and analgesic drug usetime were shorter than in the control group (all P<0.05). Conclusion:Morinidazole combined laparoscopic appendectomy can effectively control the intra-abdominal infection caused by acute purulent appendicitis and acute gangrene appendicitis with less adverse reactions.

15.
Chinese Journal of Orthopaedic Trauma ; (12): 1024-1029, 2022.
Article Dans Chinois | WPRIM | ID: wpr-992662

Résumé

Objective:To explore the safety and efficacy of the minimally invasive treatment of unstable pelvic fractures with the blunt head technique of Kirschner wire and 3D-printed external template technique.Methods:A retrospective study was conducted of the clinical data of 21 patients with unstable pelvic fracture who had undergone minimally invasive treatment at Department of Orthopaedics, Union Hospital from May 2016 to July 2018 using 3D-printed external templates and the blunt head technique of Kirschner wire. There were 7 males and 14 females with an age of 43.6 years (from 19 to 65 years). According to the Tile classification, there were 3 cases of B1, 7 ones of B2, 6 ones of C1 and 5 ones of C2. The intraoperative fluoroscopy, operation time, postoperative fracture reduction and functional recovery of the pelvis at the last follow-up were recorded.Results:The 21 patients were followed up for an average of 16.3 months (from 12 to 24 months). A total of 33 wires were inserted in the 21 patients, including 15 S 1 ones and 18 S 2 ones. The intraoperative fluoroscopy ranged from 13 to 27 times, averaging 21.8 times. The operation time ranged from 65 to 130 min, averaging 88.6 min. The anterior subcutaneous internal fixation was used to fix the anterior ring in 9 patients. No vascular injury occurred during the operation. By the Matta criteria, the postoperative fracture reduction was assessed as excellent in 14 cases, good in 5, and fair in 2, giving an excellent to good rate of 90.5% (19/21). By the Majeed scoring system, the pelvic function at the last follow-up was assessed as excellent in 10 cases, good in 8, and fair in 3, giving an excellent to good rate of 85.7% (18/21). Lateral femoral cutaneous nerve injury occurred in 2 patients but was recovered by the 3-month follow-up. No other complications were follwed up. Conclusion:The minimally invasive treatment of unstable pelvic fractures with the blunt head technique of Kirschner wire assissted by 3D-printed external templates is safe and effective, showing advatages of reduced fluoroscopic frequency and operation time.

16.
Chinese Journal of Ocular Fundus Diseases ; (6): 789-792, 2022.
Article Dans Chinois | WPRIM | ID: wpr-958524

Résumé

Vitrectomy is an important treatment for vitreoretinal diseases. After half a century of innovation and development, it has made a breakthrough from open type to micro-incision surgery. Minimally invasive vitrectomy has the advantages of wide indications and high cutting efficiency, which greatly improves the safety and efficacy of surgery, and minimizes the occurrence of trauma and complications during surgery. At present, with the development of surgical microscope system, ophthalmic microsurgery robot and other equipment, and the development and application of new artificial vitreous materials, vitrectomy is developing toward minimally invasive, accurate and intelligent development. The further development of vitrectomy innovative technology in the field of ophthalmology is hopeful in the future, so that clinicians can achieve the best surgical results with the minimum damage, and bring better light to patients.

17.
Chinese Journal of Geriatrics ; (12): 1178-1182, 2022.
Article Dans Chinois | WPRIM | ID: wpr-957360

Résumé

Objective:To evaluate clinical outcomes and complications of minimal invasive surgery for the treatment of elderly patients with fragility fracture of pelvis.Methods:Elderly patients with fragile pelvic fractures undergoing minimally invasive surgery and being followed up were retrospectively analyzed from January 2015 to December 2019.Based on the classification of pelvic fragile fractures(FFP), open reduction and internal fixation with pelvic anterior ring instability internal fixator(INFIX)plus posterior ring sacroiliac screw, or open reduction and internal fixation with iliac fossa approach, were performed for elderly patients with fragile pelvic fractures.The general data of all patients(age, sex, mechanism of injury)were recorded.Time from injury to operation, VAS(visual analogue scale)before and after operation, blood loss during operation, complications during hospitalization, time to ambulation, mortality, and Koval walking index at 2 year follow-up were recorded to evaluate clinical outcomes and complications of minimal invasive surgery for the treatment of fragility fracture of pelvis.Results:Thirty-two patients were followed up, including 11 males and 21 females, aged 65-88 years(76.9±5.5)years.The mechanism of injury was fall on the ground as a percentage of 59.4%(19/32), fall in the sitting position as a percentage of 25.0%(8/32), and 15.63%(5/32)had unknown history of trauma.The time from injury to operation was 3-36 days(9.6±3.3)days.There were 50.0%(16/32)type Ⅱ, 31.3%(10/32)type Ⅲ and 18.8%(6/32)type Ⅳ cases according to FFP classification.The mean blood loss during operation was(65.9±35.2)ml(range, 20-200 ml). The preoperative VAS score was 5-9 scores, with an average of(6.41±1.07)scores.The postoperative VAS score was 1-4(1.71±0.63). Average time from injury to operation was(9.6±3.3)days(range, 3~36). The incidence of complications during operation was 9.4%(3/32), including 1 case of gastrointestinal bleeding, 1 case of lower extremity deep vein thrombosis, and 1 case of superficial wound infection.Ambulation was at 4 weeks post-operation in 56.3%(18/32)cases, at 6 weeks post-operation in 31.3%(10/32)cases and at 8 weeks post-operation in 12.5%(4/32)cases.6.25%(2/32)patients died within 2 year follow-up.Koval walking index of the rest 30 patients included grade 1 in 46.9%(15/32)cases, grade 2 in 18.8%(6/32)cases, grade 3 in 6.3%(2/32)cases, grade 4 in 18.8%(6/32)cases and grade 6 in 3.1%(1/32)case(1 year after surgery, hemiplegia after cerebral infarction).Conclusions:Minimal invasive surgery achieves significant pain relief and early mobilization in patients with fragility fracture of pelvis.

18.
Chinese Journal of Orthopaedic Trauma ; (12): 943-949, 2022.
Article Dans Chinois | WPRIM | ID: wpr-956611

Résumé

Objective:To compare closed reduction and intramedullary nailing versus open reduction and locking plate fixation in the treatment of middle and upper humeral fractures.Methods:A retrospective case-control study was conducted to analyze the clinical data of 62 patients with middle and upper humeral fracture who had been treated at Department of Orthopaedics, The First People's Hospital of Jinmen and at Department of Orthopedics, General Hospital of PLA Central Theater from October 2017 to February 2021. There were 35 males and 27 females, aged from 27 to 86 years. The left side was affected in 24 cases and the right side in 38 cases. All fractures were fresh. According to the AO classification, 16 cases were type A, 32 type B, and 14 type C. Of the patients, 29 were treated with closed reduction and intramedullary nailing (intramedullary nail group) and 33 with open reduction and locking plate fixation (locking plate group). The length of incision, operation time, intraoperative blood loss, hospital stay, fracture healing and complications were recorded and compared between the 2 groups. The pain degree was evaluated by visual analogue scale (VAS) at one week and one month after operation, and the functional recovery of the shoulder was evaluated by Constant-Murley score at one month and 12 months after operation.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The intramedullary nail group was followed up for 12 to 29 months and the locking plate group for 15 to 50 months. In the intramedullary nail group, the length of incision [(4.1±0.7) cm], operation time [(58.3±7.7) min], intraoperative blood loss [(52.7±6.5) mL], and hospital stay [(7.3±1.5) d] were significantly less than those in the locking plate group [(21.7±2.3) cm, (95.8±11.7) min, (237.4±14.9) ml, and (12.3±1.7) d] ( P<0.05). The fracture healing time in the intramedullary nail group was (5.0±1.9) months, significantly longer than that in the locking plate group [(3.5±1.7) months] ( P<0.05). The VAS scores at one week and one month after operation in the intramedullary nail group [(2.8±0.3) points and (1.2±0.5) points] were significantly lower than those in the locking plate group [(4.3±0.4) points and (1.6±0.5) points], and the Constant-Murley score at one month after operation in the intramedullary nail group [(63.5±7.4) points] was significantly higher than that in the locking plate group [(54.3±6.9) points] ( P<0.05). However, at 12 months after operation, there was no significant difference in the Constant-Murley score between the 2 groups ( P>0.05). In both groups, the VAS score at one month after operation was significantly lower than that at one week after operation while the Constant-Murley score at 12 months after operation was significantly higher than that at one week after operation ( P<0.05). In the intramedullary nail group, intraoperative distal refracture happened in one case; in the locking plate group, incision infection occurred in one case and postoperative radial nerve injury in another. There was no significant difference in the incidence of complications between the 2 groups [3.4% (1/29) versus 6.1% (2/33)] ( P>0.05). Conclusion:In the treatment of middle and upper humeral fractures, compared with open reduction and locking plate fixation, closed reduction and intramedullary nailing shows advantages of a smaller surgical incision, shorter operation time, less intraoperative blood loss, shorter hospital stay and faster functional recovery.

19.
Chinese Journal of Orthopaedic Trauma ; (12): 935-942, 2022.
Article Dans Chinois | WPRIM | ID: wpr-956610

Résumé

Objective:To compare the clinical effects of minimally invasive reduction through a bone tunnel combined with Jail screwing and those of posterolateral locking plating in the treatment of simple posterolateral tibial plateau fractures.Methods:A retrospective analysis was conducted of the data of 48 patients who had been operatively treated and completely followed up at Department of Orthopedics, Suqian Hospital of Nanjing Drum Tower Hospital Group for simple posterolateral tibial plateau fractures from October 2016 to October 2020. There were 26 males and 22 females, aged from 35 to 68 years. They were divided into a minimally invasive group (25 cases subjected to minimally invasive reduction through a bone tunnel combined with Jail screwing) and an incision group (23 cases subjected to posterolateral locking plating) according to their surgical methods. The operation time, incision length, intraoperative blood loss, fracture healing time, cumulative fluoroscopy time, hospital stay and posterior inclination angles of the tibial plateau and Hospital for Special Surgery (HSS) knee function scores at 1, 3, 6, 9, and 12 months after operation were compared between the 2 groups. Complications in the 2 groups of patients were recorded.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The 48 patients were followed up for 12 to 36 months (average 16.5 months). The minimally invasive group was significantly better than the incision group in operation time [(42.6±9.1) min versus (65.7±11.5) min], incision length [(4.0±0.4) cm versus (15.0±1.5) cm], intraoperative blood loss[(22.6±5.8) mL versus (31.5±8.8) mL], hospital stay [(7.6±1.4) d versus (11.1±2.4) d], and HSS score one month after operation [(84.8±1.9) points versus (72.9±4.1) points], but the cumulative fluoroscopy time in the incision group [(4.1±1.4) s]was significantly less than that in the minimally invasive group [(22.3±4.2) s] ( P<0.05). There were no significant differences in fracture healing time, HSS scores at 3, 6, 9, or 12 months after operation, or posterior inclination angle of the tibial plateau between the 2 groups ( P>0.05). There were no such complications as wound infection, vascular injury, internal fixation failure, nonunion or malunion of fractures in either of the 2 groups. Two cases in the incision group presented with symptoms of common peroneal nerve injury but recovered 3 months after operation. Conclusions:Although both minimally invasive reduction through a bone tunnel combined with Jail screwing and posterolateral locking plating can achieve satisfactory outcomes in the treatment of simple posterolateral tibial plateau fractures, the minimally invasive technique is preferable because it shows the advantages of a smaller incision, less bleeding, shorter operation time, a lower operation risk, quicker postoperative recovery and shorter hospital stay.

20.
Chinese Journal of Orthopaedic Trauma ; (12): 856-861, 2022.
Article Dans Chinois | WPRIM | ID: wpr-956598

Résumé

Objective:To explore the efficacy and safety of TiRobot combined with three-dimensional imaging in the minimally invasive surgery for pelvic fractures.Methods:A retrospective analysis was conducted of the 40 patients with pelvic fracture who had been treated by fixation with S1 and S2 sacroiliac screws at Department of Orthopaedics and Traumatology, Yangjiang People's Hospital from January 2019 to May 2021. They were divided into 2 groups according to their treatment methods. In the TiRobot group of 20 cases subjected to percutaneous sacroiliac screw fixation assisted by TiRobot combined with three-dimensional imaging, there were 13 males and 7 females with an age of (38.2 ± 8.8) years. In the manual group of 20 cases subjected to fixation with manual placement of sacroiliac screws under conventional C-arm fluoroscopy, there were 11 males and 9 females with an age of (37.3 ± 9.2) years. The 2 groups were compared in terms of fluoroscopy time for screw placement, guide needle adjustment, operation time, intraoperative blood loss, visual analogue scale (VAS) 72 hours after operation, postoperative hospital stay, time to ambulation, excellent to good rate of screw placement, complication rate, fracture union time, Majeed score at 6 months after operation, and excellent to good rate of functional evaluation.Results:There was no significant difference between the 2 groups in their preoperative general data, showing they were comparable ( P > 0.05). In the TiRobot group, fluoroscopy time for screw placement [(8.2 ± 2.9) s], guide needle adjustment [(0.4 ± 0.2) times], operation time [(67.4 ± 5.5) min], and intraoperative blood loss [(36.5 ± 8.0) mL] were significantly less than those in the manual group [(40.4 ± 4.5) s, (8.6 ± 0.7) times, (78.4 ± 7.2) min, and (41.6 ± 7.8) mL], postoperative VAS [3.0 (4.0, 5.0) points] was significantly lower than that in the manual group [4.0 (5.0, 6.0) points], the excellent to good rate of screw placement (100%, 40/40) was significantly higher than that in the manual group (85.0%, 34/40), and the complication rate (5.0%,1/20) was significantly lower than that in the manual group (35.0%, 7/20) (all P < 0.05). There was no significant difference between the 2 groups in postoperative hospital stay, time to ambulation, fracture union time, Majeed score, or excellent to good rate of functional evaluation ( P > 0.05). Conclusion:In the minimally invasive surgery for pelvic fractures, TiRobot combined with three-dimensional imaging leads to positive outcomes, because it can reduce operation time and radiation exposure, improve accuracy of screw placement, and increase safety.

SÉLECTION CITATIONS
Détails de la recherche