RÉSUMÉ
ABSTRACT Purpose: To investigate ocular surface and meibomian glands in patients with treatment-naive acne vulgaris. Methods: The Ocular Surface Disease Index (OSDI) questionnaire, invasive tear film breakup time, fluorescein staining of the ocular surface, and Schirmer II test were performed for all subjects. Total eyelid and meibomian gland secretion scores were assessed. Non-contact meibography was performed with the Sirius corneal topographic device. Results: The right eyes of 35 patients with acne vulgaris and 35 healthy volunteers were included the study. While the OSDI and staining scores were significantly higher in the acne group than in the control group (p=0.01 and p=0.003, respectively), the invasive tear film breakup time and Schirmer measurements were significantly lower in the acne group (p=0.000 and p=0.003, respectively). The total eyelid and meibomian gland secretion scores were also higher in the acne group than in the control group (p=0.003 and p=0.000, respectively). On the morphological evaluation of the meibomian glands, the thickening, thinning, tortuosity, and presence of ghost areas were statistically significantly more common in the acne vulgaris group than in the control group (p=0.000, p=0.001, p=0.05, and p=0.006, respectively). The percentage of the meibomian gland loss area was significantly high in the acne vulgaris group on both upper and lower meibography. The meibomian gland loss area positively correlated with total eyelid and meibomian gland secretion scores. Conclusion: Acne vulgaris may have a predisposition to meibomian gland dysfunction and ocular surface damage. Early recognition of meibomian gland and ocular surface alterations seems important, especially in acne vulgaris cases for which oral isotretinoin treatment is planned.
RESUMO Objetivo: Todos os indivíduos responderam ao questionário Ocular Surface Disease Index (OSDI) e tiveram avaliados o tempo de ruptura do filme lacrimal pelo método invasivo, a coloração da superfície ocular com fluoresceína e o teste de Schirmer II. Foram ainda avaliados o escore palpebral total e o de secreção das glândulas meibomianas. Foi realizada meibografia sem contato com um dispositivo topográfico corneano Sirius. Métodos: Todos os indivíduos responderam ao questionário Ocular Surface Disease Index (OSDI) e tiveram avaliados o tempo de ruptura do filme lacrimal pelo método invasivo, a coloração da superfície ocular com fluoresceína e o teste de Schirmer II. Foram ainda avaliados o escore palpebral total e o de secreção das glândulas meibomianas. Foi realizada meibografia sem contato com um dispositivo topográfico corneano Sirius. Resultados: Foram incluídos no estudo os olhos direitos de 35 voluntários com acne vulgar e 35 saudáveis. Os escores do Ocular Surface Disease Index e da coloração foram significativamente maiores no grupo com acne em comparação com o grupo controle (p=0,01 e p=0,003, respectivamente), mas o tempo de ruptura do filme lacrimal pelo método invasivo e as medidas do teste de Schirmer II foram significativamente menores (p=0,000 e p=0,003, respectivamente). O escore palpebral total e o escore de secreção das glândulas meibomianas também foram maiores no grupo com acne que no grupo controle (p=0,003 e p=0,000). Na avaliação morfológica das glândulas meibomianas, o espessamento, o afinamento, a tortuosidade e a presença de áreas fantasmas nas glândulas foram mais comuns no grupo acne vulgar que no grupo controle, com significância estatística (p=0,000, p=0,001, p=0,05 e p=0,006 respectivamente). A porcentagem da área de perdas das glândulas meibomianas foi significativamente mais alta no grupo com acne vulgar, tanto na meibografia superior quanto na inferior. A área de perda das glândulas meibomianas demonstrou uma correlação positiva com o escore palpebral total e com o escore de secreção das glândulas meibomianas. Conclusão: A acne vulgar pode levar a uma predisposição para a disfunção das glândulas meibomianas e para danos na superfície ocular. Parece ser importante reconhecer precocemente as alterações das glândulas meibomianas e da superfície ocular, especialmente nos casos de acne vulgar para os quais se planeja o tratamento oral com isotretinoína.
RÉSUMÉ
ABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group comprised of eyes with best-corrected visual acuity of 0.0 logMAR or better and present at least a refractive error of ≥0.25 D. Patients underwent slit lamp examination, visual acuity, refraction, and vision quality using the HD Analyzer. Results: The mean objective light scatter indices were 0.62 ± 0.63, 0.77 ± 0.70, 0.74 ± 0.30, 0.93 ± 0.55, and 0.85 ± 0.61, and mean Strehl Ratio and Modulation Transfer Function scores were 38.17 ± 10.4, 37.37 ± 10.06, 29.84 ± 9.71, 33.2 ± 12.11, and 33.13 ± 10.09 in emmetropes, myopia, hyperopia, spherical equivalent of ≥0, and spherical equivalent of <0, respectively. Differences in all variables were significant between emmetropic and corrected hyperopic and between spherical equivalent of ≥0, and spherical equivalent of <0 eyes (p<0.05). Conclusion: In spectacle-corrected conditions (with trial frames), emmetropic and simple myopic eyes had significantly better vision quality compared to hyperopic and astigmatic eyes. The clinical significance of these results should be investigated in further studies.
RESUMO Objetivo: Avaliar a qualidade óptica medindo o índice de dispersão objetiva de luz e os parâmetros de qualidade óptica objetiva (Razão de Strehl e Função de Transferência de Modulação) em indivíduos com emetropia e ametropia. Métodos: Estudo prospectivo, transversal, incluindo 408 olhos. O grupo ametrópico era de olhos com melhor acuidade visual corrigida de 0,0 logMAR ou melhor e apresentando, pelo menos, um erro refrativo de 0,25 D ou mais. Os pacientes foram submetidos a exame com lâmpada de fenda, acuidade visual, refração e qualidade óptica com o HD Analyzer. Resultados: O índice de dispersão objetiva de luz médio foi de 0,62 ± 0,63, 0,77 ± 0,70, 0,74 ± 0,30, 0,93 ± 0,55, 0,85 ± 0,61 e a média da Razão de Strehl e de Função de Transferência de Modulação foram 38,17 ± 10,4, 37,37 ± 10,06, 29,84 ± 9,71, 33,2 ± 12,11 e 33,13 ± 10,09 em olhos emetrópicos, míopes, hipermétropes, equivalente esférico ≥0 e equivalente esférico <0 respectivamente. Foram encontradas diferenças significativas em todas as variáveis entre olhos emetrópicos e com hipermetropia corrigida, equivalente esférico ≥ 0 e equivalente esférico <0 (p<0,05). Conclusão: Em condições com lentes corrigidas (com armações de prova), os olhos emetrópicos e com miopia simples apresentaram qualidade óptica significativamente melhor em comparação com os olhos hipermétropes e astigmáticos. O significado clínico destes resultados deve ser estudado posteriormente.
RÉSUMÉ
Background: Influenza A virus (IAV) surveillance in swine is critical not only due to the direct impact of the disease in the pork industry but also because IAV are prone to interspecies transmission (from human to pigs and vice versa); therefore, its monitoring is fundamental from a public and animal health perspective. Several diagnostic techniques have been used to detect IAV infection from nasal samples in swine, while samples of oral fluids (OF) are in use as novel alternatives for pathogen detection. The OF allow for efficient and feasible low-cost disease detection at the herd level, with low risk of stress for the animals. Objective: To describe a surveillance strategy of IAV at the herd level during respiratory disease outbreaks in swine farms at tropical settings using porcine oral fluids. Methods: An active surveillance strategy was conducted in several farms with past records of respiratory disease. The IAV detection was conducted in five purposively selected swine farms from years 2014 to 2017. We investigated a total of 18 respiratory outbreaks of the disease. Swine OF were collected for IAV testing. An OF sample is described as a pen-based specimen collected from a group of >20 pigs per pen and/or per barn (stall-housed individually with close contact among them). The IAV infection was investigated in OF by rRT-PCR testing and confirmed by viral isolation in cell culture Results: We found 107 (7.4%) positives to IAV by rRT-PCR from a total of 1,444 OF samples tested. Additionally, 9 IAV isolates were all further identified as H1 subtype. Conclusions: Our results demonstrate that OF can be easily implemented as a novel, user-friendly, welfare-friendly, accurate and cost-effective sampling method for active surveillance and monitoring of IAV infections in swine farms in tropical settings.
Antecedentes: La vigilancia del Virus Influenza A (IAV) en los cerdos es fundamental debido al impacto directo de la enfermedad en la industria porcina, pero también porque los IAV son propensos de transmisión entre especies (humanos a cerdos y viceversa), y por lo tanto su monitoreo es crítico desde las perspectivas de salud pública y animal. Actualmente existen varias técnicas de diagnóstico disponibles para detectar la infección por IAV a partir de muestras nasales en cerdos, sin embargo, se han implementado otras muestras como los fluidos orales (OF) como nuevas alternativas para la detección de patógenos. El OF permite una detección eficiente y factible de enfermedades a menor costo a nivel de rebaño, con menor riesgo de estrés para los animales. Objetivo: Describir una estrategia de vigilancia de IAV a nivel de hato por medio de fluidos orales porcinos durante brotes de enfermedades respiratorias en granjas porcinas en entornos tropicales. Métodos: Se llevó a cabo una estrategia de vigilancia activa en cinco granjas porcinas seleccionadas con antecedentes de enfermedades respiratorias. Se recolectaron OF porcinos para la prueba de IAV. Una muestra de OF se describió como una muestra grupal recolectada de un grupo de >20 cerdos por corral y/o por establo (si estaban alojados individualmente, pero tenían un contacto cercano entre ellos). La infección por IAV se investigó probando OF mediante rRT-PCR y la confirmación mediante aislamiento viral en cultivo celular. Resultados: La detección de IAV se llevó a cabo en cinco granjas seleccionadas intencionalmente entre 2014- 2017. Investigamos un total de 18 eventos de brotes de enfermedades respiratorias. Del total de 1.444 OF muestras analizadas, encontramos 107 (7,4%) positivos a IAV mediante rRT-PCR. Además, solo se obtuvieron 9 aislamientos de IAV y todos se identificaron además como subtipo H1. Conclusiones: Los resultados de nuestro estudio demostraron cómo la OF puede implementarse fácilmente como un método de muestreo novedoso, fácil de usar, amigable con el bienestar animal, preciso y rentable para la vigilancia activa y el monitoreo de infecciones por IAV en granjas porcinas en entornos tropicales.
Antecedentes: A vigilância do vírus Influenza A (IAV) em suínos é crítica devido ao impacto direto da doença na indústria de suínos, mas também porque os IAV são propensos a transmissão interespécies (de humanos para porcos e vice-versa) e, portanto, seu monitoramento é crítico do ponto de vista da saúde pública e animal. Atualmente, existem várias técnicas de diagnóstico disponíveis para detectar a infecção por IAV em amostras nasais de suínos, no entanto, outras amostras, como fluidos orais (OF), têm sido implementadas como novas alternativas para a detecção de patógenos. O OF permite uma detecção eficiente e viável de doenças com menor custo em nível de rebanho, com menor risco de estresse para os animais. Objetivo: Descrever uma estratégia de vigilância de IAV em nível de rebanho durante surtos de doenças respiratórias em granjas de suínos em ambientes tropicais por meio de fluidos orais suínos. Métodos: A estratégia de vigilância ativa foi conduzida em cinco granjas de suínos selecionadas com histórico de doenças respiratórias. Suínos OF foram coletados para teste de IAV. Uma amostra OF foi descrita como um espécime baseado em curral coletado de um grupo de >20 porcos por curral e/ou por celeiro (se eles foram alojados individualmente, mas tendo contato próximo entre eles). A infecção IAV foi investigada testando OF por rRT-PCR e confirmada por isolamento em cultura de células. Resultados: A detecção do IAV foi realizada em cinco fazendas selecionadas propositalmente entre 2014-2017. Nós investigamos um total de 18 eventos de surto de doença respiratória. Do total de 1.444 amostras de OF testadas, encontramos 107 (7,4%) positivas para IAV por rRT-PCR. Além disso, apenas 9 isolados de IAV foram obtidos, e todos foram posteriormente identificados como subtipo H1. Conclusão: Os resultados de nosso estudo demonstraram como o OF pode ser facilmente implementado como um método de amostragem novo, amigável, amigável com o bem-estar, preciso e de baixo custo para vigilância ativa e monitoramento de infecções IAV em fazendas de suínos em ambientes tropicais.
RÉSUMÉ
Resumen: Presentamos la primera experiencia en Uruguay de una biopsia endobiliar con pinza por acceso percutáneo que realizáramos en una paciente con estenosis biliar hiliar de probable causa neoplásica. Hasta nuestro conocimiento, no existen reportes de esta técnica en Uruguay. La difusión de la disponibilidad de esta técnica en nuestro medio es de gran importancia, ya que permite al equipo médico tratante disponer de una nueva herramienta para el manejo diagnóstico de las estenosis biliares.
Abstract: The study presents the first experience in Uruguay of a forceps biopsy of biliary ducts via percutaneous catheterization performed in a patient with hilar biliary strictures probably caused by a tumor. As far as we know, no reports on this technique have been published in our country. It is important to spread the availability of this technique in our country since it provides the medical team with a new tool for the diagnostic handling of biliary strictures.
Resumo: Apresentamos a primeira experiência no Uruguai de uma biópsia endobiliária com pinça de acesso percutânea realizada em um paciente com estenose biliar hilar de provável causa neoplásica. Para nosso conhecimento, não há relatos dessa técnica no Uruguai. A difusão da disponibilidade dessa técnica em nosso ambiente é de grande importância, pois permite à equipe médica responsável o tratamento ter uma nova ferramenta para o manejo diagnóstico da estenose biliar.
Sujet(s)
Humains , Femelle , Adulte d'âge moyen , Maladie des voies biliaires/diagnostic , Biopsie/méthodes , Sténose pathologique/diagnosticRÉSUMÉ
OBJETIVO: O objetivo deste estudo foi desenvolver um padrão de avaliação diagnóstica pela Core biopsy com agulha de 16G em lesões mamárias. Utilizando critérios ecográficos padronizados e relacionando os resultados ao tamanho das lesões investigadas e avaliando o número ideal de fragmentos a serem colhidos. MÉTODOS: Estudo prospectivo de maio de 2004 a setembro de 2005 em 79 pacientes com lesões incluídas nas categorias 2, 3, 4 e 5, segundo Bi-RADS® US, realizando Core Biopsy com agulha de 16G, retirando-se cinco fragmentos numerados e colocados individualmente em frascos com formol a 10 por cento. RESULTADOS: De 84 biópsias realizadas houve 81 diagnósticos conclusivos (96 por cento), com 43 malignos (51 por cento) e 38 benignos (45 por cento). A eficácia da Core biopsy aumenta com o número de amostras colhidas: com uma amostra é de 95,24 por cento,duas amostras 96,93 por cento; três amostras 98,8 por cento; quatro amostras 98,81 por cento; cinco amostras 100 por cento. CONCLUSÃO: A retirada de três fragmentos foi suficiente para um resultado satisfatório.
OBJECTIVE: The objective of this study was to develop a standard diagnostic evaluation with 16G core-needle biopsy for breast lesions. We evaluated the ideal number of fragments using standard ultrasound criteria based on the previous results obtained on the size of the lesions. MEHTODS: A prospective study was carried out, from may 2004 to September 2005, in 79 patients with lesions that included categories 2,3,4 and 5, according to BIRADS -USTM using 16G core biopsy needle. We took up 5 pieces numbered and placed individually in vials with 10 percent formalin. RESULTS: In 84 biopsies performed there were 81 conclusive diagnoses (96 percent), with 43 malignant results (51 percent) and 38 benign results (45 percent). The effectiveness of the core biopsy increased with the sample numbers: one sample is 95.24 percent accurate; two samples reach 96.93 percent; three samples reach 98.8 percent; four samples reach 98.81 percent, and finally, five samples reach 100 percent accuracy. CONLCUSION: the resection of three fragments was sufficient for a satisfactory result.