RÉSUMÉ
Objective:To provide a basis for selecting the optimization method for intracavitary/interstitial brachytherapy (IC/ISBT) of cervical cancer by comparing graphical optimization (GO), inverse planning simulated annealing (IPSA), and hybrid inverse planning optimization (HIPO) using dosimetric and radiobiological models.Methods:This study selected 65 patients with cervical cancer who were treated with image-guided IC/ISBT. The afterloading therapy plans for these patients were optimized using GO, IPSA, and HIPO individually, with a prescription dose high-risk clinical target volume (HRCTV) D90 of 6 Gy. The non-parametric Friedman test and the non-parametric Wilcoxon rank test were employed to analyze the differences in duration, dose-volume parameters, and radiobiology between the three types of optimized plans. Results:Inverse planning optimization (IPSA: 46.53 s; HIPO: 98.36 s) took less time than GO (135.03 s). In terms of gross target volume (GTV) dose, the high-dose irradiation V150% (53.66%) was slightly higher in the HIPO-optimized plans, while the V200% (30.29%) was higher in the GO-optimized plans. The GO-optimized plans had a higher conformity index (CI; 0.91) than other plans, showing statistically significant differences. Compared with other plans, the HIPO-optimized plans showed the lowest doses of D1 cm 3 and D2 cm 3 at bladders and rectums and non-statistically significant doses at small intestines ( P > 0.05). In terms of the equivalent uniform biologically effective dose (EUBED) for HRCTV, the HIPO-optimized plans showed a higher value (12.35 Gy) than the GO-optimized plans (12.23 Gy) and the IPSA-optimized plans (12.13 Gy). Moreover, the EUBED at bladders was the lowest (2.38 Gy) in the GO-optimized plans, the EUBED at rectums was the lowest (3.74 Gy) in the HIPO-optimized plans, and the EUBED at small intestines was non-significantly different among the three types of optimized plans ( P = 0.055). There was no significant difference in the tumor control probability (TCP) predicted using the three types of optimized plans ( P > 0.05). The normal tissue complication probabilities (NTCPs) of bladders and rectums predicted using the HIPO-optimized plans were lower than those predicted using the GO- and IPSA-optimized plans( χ2 = 12.95-38.43, P < 0.01), and the NTCP of small intestines did not show significant differences ( P > 0.05). Conclusions:Among the three types of optimization algorithms, inverse optimization takes less time than GO. GO-optimized plans are more conformal than IPSA- and HIPO-optimized plans. HIPO-optimized plans can increase the biological coverage dose of the target volume and reduce the maximum physical/biological exposure and NTCP at bladders and rectums. Therefore, HIPO is recommended preferentially as an optimization algorithm for IC/ISBT for cervical cancer.
RÉSUMÉ
Purpose: In this study, it is aimed to compare three different radiotherapy treatment planning techniques in terms of critical organ scoring index (COSI), two different conformity index (CI), tumor control probability (TCP), and normal tissue complication probability (NTCP) calculations in early (T1) glottic larynx carcinoma (T1GL). Furthermore, it is aimed to investigate these parameters compliance with dose-volume histograms (DVH) parameters. Materials and Methods: Ten T1GL patients were immobilized in a supine position with a head and neck thermoplastic mask. Treatment plans were created with opposed lateral fields (OLAFs) and intensity-modulated radiation therapy (IMRT) techniques with a total dose of 66 Gy in 33 fraction with 2 Gy/day. IMRT fields were selected as five fields (5IMRT) and seven fields (7IMRT). Dosimetric evaluation of three different treatment plans for T1GL carcinoma was performed in two consequential steps. First step was the assessment of planning target volume (PTV), all organs at risks (OARs), and normal tissue (NT) dose calculations according to given dose constraint directions and comparing the plans via DVH. In the second step, for PTV, the compatibility of DVH data with CIs-TCP was investigated where COSI-NTCP was compared with DVH for OARs. The DVH data were considered as reference in all evaluations. Results: The CIRTOG mean values were significantly closer to 1 with IMRT plans when compared to OLAF plans (P = 0.005). The CIPADDICK mean values revealed that OLAF plans were significantly worse than IMRT plans (P = 0.005). No statistically significant difference was found between all three plans in terms of homogeneity index mean values (P = 0.076). The calculated mean TCP values were significantly better for 7IMRT plans when compared to OLAF and 5IMRT plans (P = 0.007 and P = 0.017, respectively). Both NTCP and COSI evaluations, which is compatible with DVH, significantly favored OLAF plan for spinal cord and 7IMRT for thyroid gland. The COSI evaluations, which are compatible with DVH, significantly favored 7IMRT plan for carotid arteries and 5IMRT plan for NT. Conclusion: Our results demonstrated that CIPADDICK-TCP calculations for PTV and COSI-NTCP calculations for OARs were compatible with DVH in T1 GL plans. Therefore, we suggest such parameters as valuable tools for choosing the feasible one among multiple plans and even with different treatment machines
RÉSUMÉ
BACKGROUND: To compare dosimetric parameters of intensity‑modulated radiation therapy (IMRT) with 3D conformal radiotherapy (3DCRT) in post‑operative patients of vulvar cancer and to assess clinical outcome and toxicity with IMRT. MATERIALS AND METHODS: A total of 8 post‑operative patients of vulvar cancer were treated with IMRT. All patients were also planned by 3DCRT for comparison with IMRT. The two plans were compared in terms of conformity index, homogeneity index, tumor control probability (TCP) and normal tissue complication probability (NTCP) for the planning target volume and organs at risk (OAR). RESULTS: IMRT resulted in significantly lesser doses to rectum, bladder, bowel and femoral head as compared with 3DCRT plans. Mean conformity and homogeneity indices were better and within range with IMRT. The TCP was comparable between the two treatment plans and NTCP for rectum, bladder, bowel and femoral head was significantly less with IMRT as compared with 3DCRT. Treatment was well‑tolerated and none of the patients developed Grade 3 or higher toxicity. CONCLUSION: IMRT yielded superior plans with respect to target coverage, homogeneity and conformality while lowering dose to adjacent OAR as compared with 3DCRT. Thus, IMRT offers a reduction in NTCP while maintaining TCP.
RÉSUMÉ
PURPOSE: To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). MATERIALS AND METHODS: We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating filters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was performed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. RESULTS: Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC (multi-leaf collimator). CONCLUSION: IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.