Chinese Journal of Ultrasonography ; (12): 508-514, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992855

Résumé

Objective:To discuss the effect of remnant cholesterol (RC) levels on carotid intima thickness (CIT) in patients with type 2 diabetes mellitus (T2DM) by ultra-high frequency ultrasound.Methods:A total of 60 patients with T2DM who received treatment in Henan Provincial People′s Hospital from May 2021 to July 2022 were prospectively recruited, and they were divided into a higher RC group (31 cases) and a lower RC group (29 cases) according to the RC levels. Thirty-one age, sex and body mass index(BMI)-matched healthy volunteers were selected as control group. Carotid CIT, carotid media thickness(CMT) and intima-media thickness(CIMT) were measured by 24 MHz ultra-high frequency ultrasound probe. The difference of general clinical data, laboratory indicators and CIMT, CIT, CMT among the three groups were compared, and the influencing factors of CIT in T2DM patients were explored by multivariate regression analysis.Results:①There were no statistical significances in gender, age, BMI, high-density lipoprotein cholesterol (HDL-C) and CMT among the three groups (all P>0.05). There were no statistical significances in duration of diabetes, fasting blood-glucose and glycated haemoglobin between the two subgroups of T2DM (all P>0.05). ②Compared with the control group, CIMT and CIT were thicker in the T2DM group (both P<0.05). ③CIT was thicker in the higher RC group than in the lower RC group ( P<0.05), while the difference of CIMT was not statistically significant the two groups ( P>0.05). ④Multivariate regression analysis showed that RC was the influence factor of CIT in patients with T2DM(β=0.610, P=0.005). Conclusions:CIT is significantly thicker in T2DM patients with higher RC than in those with lower RC, and RC is the influence factor of CIT, which suggests that more attention should be paid to the detection of RC in T2DM patients.

2.
China Occupational Medicine ; (6): 423-427, 2019.
Article Dans Chinois | WPRIM | ID: wpr-881812

Résumé

OBJECTIVE: To explore the effect of ultra-high frequency radiation on psychomotor neurological behavior in workers with exposure. METHODS: A total of 85 workers who exposed to 40.68 MHz radiofrequency were recruited as the exposure group by judgment sampling method. A group of 121 workers without occupational EMR exposure were recruited as the control group. Workers in both groups were from the same shoe factory. The electric field intensity(EFI) of ultra-high frequency radiation of workplace in the exposure group was measured. The computerized neurobehavioral evaluation system in Chinese version 3 was used to evaluate the psychomotor neurobehavioral function which included the neurobehavioral ability index(NAI) of simple visual reaction time(SVRT), digital screening and fit curve and the general NAI(GNAI) of the above 3 indexes. RESULTS: The median of the workplace EFI of ultra-high frequency radiation in the exposure group was 119.0 V/m, and all of them exceeded the national occupational exposure limit. NAI of digital screening in exposure group was lower than that in the control group(P<0.05). There is no statistically significant difference in the NAI of SVRT, fit curve and GNAI(P>0.05). Meanwhile, there is no statistically significant difference in abnormal rate of NAI of SVRT, digital screening, fit curve and GNAI(P>0.05). The results of multiple linear regression analysis showed that the ultra-high frequency radiation EFI exposure was negatively correlated with NAI of digital screening(P<0.05) after eliminating the influence of confounding factors such as age, working age, gender, education level, smoking, drinking and staying up late. CONCLUSION: The digital screening of psychomotor neurobehavioral function in the exposure workers was adversely affected by the ultra-high frequency radiation. The neural behavioral ability of eye-hand coordination and precise movement may be the specific performance.

3.
Chinese Journal of Comparative Medicine ; (6): 19-23, 2014.
Article Dans Chinois | WPRIM | ID: wpr-453858

Résumé

Objective To explore the application value of ultra -high frequency ultrasound in detection of femoral artery stenosis in rabbits.Methods Twenty-four healthy male New Zealand white rabbits (body weight 2.5 -3.0 kg) were randomly divided into three groups , 8 rabbits in each group.Preparation of femoral atherosclerosis model : the rabbits were fed with high fat diet for 4 weeks, 8 weeks and 12 weeks after femoral artery balloon injury , respectively.The changes of cholesterol level were observed .We used ultra-high frequency ultrasonic probe to observe the femoral artery , to assess the diameter stenosis rate and peak systolic velocity (SPV) at the symptomatic side, and the histological areal stenosis was evaluated.Results 1.The blood cholesterol levels were increased after fed high cholesterol diet , with a significant difference among the groups (P <0.001); 2.There was a stenosis to a different degree in the modeling artery after fed high cholesterol diet for 4 wks, 8 wks, and 12 wks, and the stenosis degree was increased gradually .At 12 w, the degree of stenosis was higher than that at 4 w and 8 w, respectively, showing statistical significance ( P <0.001).At the symptomatic side, the peak systolic flow velocity was increased , and it was higher at 12 w than that at 4w and 8 w, respectively.3.With the extension of time, the arterial stenosis rate was increased along with the time course (P <0.05). Conclusions 1.High fat diet combined with balloon injury can cause varying degrees of rabbit femoral artery stenosis ; 2. Ultrahigh frequency ultrasound can clearly show different degrees of rabbit femoral artery stenosis , and can be used for detecting the lesions in animal models of peripheral vascular diseases .

4.
Rev. cuba. oftalmol ; 18(1)ene.-jun. 2005.
Article Dans Espagnol | LILACS | ID: lil-629411

Résumé

Se realizó un estudio prospectivo, descriptivo en 50 pacientes operados de catarata que acudieron a la consulta de oftalmología (especialidad de retina), en el período comprendido entre septiembre de 2002 hasta junio de 2004 en el Hospital Militar Central "Dr. Carlos J. Finlay", los cuales, en el posoperatorio presentaron una disminución de la agudeza visual por edema macular quístico. Se les aplicó tratamiento con ultra-alta frecuencia a 20 watt, en un período de 10 a 20 sesiones. Al finalizar el tratamiento, el 94 % de los pacientes mejoró la agudeza visual, lo que demostró la utilidad del método empleado en esta patología.


A prospective descriptive study was conducted in 50 patients operated on of cataract that visited the ophthalmological office (retina specialty) from September 2002 to June 2004 at "Dr Carlos J. Finlay" Central Military Hospital. These patients presented in the postoperataive a reduction of the visual acuity due to cystic macular edema. They received between 10 and 20 sessions of ultra-high frequency of 20 watts. At the end of the treatment, 94 % of the patients improved the visual acuity, which showed the usefulness of the method applied to this pathology.

5.
Journal of Pharmaceutical Analysis ; (6): 101-104,109, 2005.
Article Dans Chinois | WPRIM | ID: wpr-625027

Résumé

Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS.There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.

6.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 82-85, 1997.
Article Dans Coréen | WPRIM | ID: wpr-653740

Résumé

The goal of treatment in OME is normal aerated middle ear space. When the tympanogram convert to type A or C from type B in patients with OME, no further medication would be needed. But 1/3 of these patient had type B tympanogram again after 4 weeks follow up without medication. Many parameters-including age, sex, season, unilaterality, passive smoking, associated rhinitis etc-were concerned about the recurrence of OME. Ultra high frequency audiometry was added as a new parameter in recurrence of OME.