Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Medical Equipment Journal ; (6): 82-83,118, 2015.
Article Dans Chinois | WPRIM | ID: wpr-600539

Résumé

Objective To evaluate the clinical efficacy of ultrasonic-harmonic scalpel in open thyroid surgery.Methods Totally 70 patients with thyroid surgery from January 2012 to January 2014 in some hospital were selected as the study objects, who were divided into a control group and an observation group equally. The patients in the control group went through traditional surgery, and the ones in the observation group underwent open thyroid surgery. Then the operative time, blood loss, postoperative hospital stay before and after surgery and body stress-related serum markers of two groups were analyzed and compared.Results The observation group had the operative time, blood loss and postoperative hospital stay significantly better than those of the control group, and the body stress-related serum markers 5 days after operation significantly lower than that of the control group, with P<0.05.Conclusion The short-term clinical effect of ultrasonic-harmonic scalpel in open thyroid surgery is significantly better than that of traditional surgery, which has high safety and lower degree of adverse physical stress.

2.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1454-1455, 2012.
Article Dans Chinois | WPRIM | ID: wpr-425833

Résumé

ObjectiveTo explore the effect of ultrasonic harmonic scalpel on stress after radical resction of esophageal carcinoma.MethodsAll 115 patients of esophageal carcinoma undergone radical esophagectomy were analyzed retrospectively.60 patients were performed with ultrasonic harmonic scalpel,the other 55 patients were performed with electrotome.The drainage volume of 72h after operation,postoperative complications and hospital days were analyzed.White blood cell count,Neu,CRP and blood glucose level were tested 2 days after operation.ResultsThere was significant difference in the drainage volume of 72h after operation (P < 0.05 ),but the postoperative complications and hospital days had no obvious difference.White blood cell count,Neu,CRP and blood glucose were obviously increased after operation( all P < 0.05 ) ;the barmonic scalpel group was dramatically decreased as compared with the electrotome group except blood glucose ( all P < 0.05 ).ConclusionRadical resection of esophageal carcinoma using ultrasonic harmonic scalpel appears to decrease the drainage volume of 72h after operation and less the stress.

3.
Chinese Journal of Minimally Invasive Surgery ; (12)2005.
Article Dans Chinois | WPRIM | ID: wpr-584944

Résumé

Objective To evaluate the safety of temporary cardiac pacemaker during perioperative period of laparoscopic cholecystectomy (LC) in patients with bradyarrhythmia. Methods Temporary cardiac pacemakers were installed preoperatively in 34 elderly patients with bradyarrhythmia for LC. On operation the ultrasonic harmonic scalpel, instead of electrotome, was used to perform dissection and coagulation. Results LC was completed successfully in all the 34 patients without surgery-related complications or perioperative serious cardiovascular diseases. Conclusions Utilization of temporary cardiac pacemaker and ultrasonic harmonic scalpel may considerably enhance the perioperative safety and reduce the incidence of cardiovascular complications in elderly patients with bradyarrhythmia.

4.
Journal of Medical Postgraduates ; (12)2003.
Article Dans Chinois | WPRIM | ID: wpr-589116

Résumé

Objectives:To establish a method of electric power detection and to evaluate its performance for ultrasonic harmonic scalpel(UHS).Methods:We defined maximum electric power(Pmax),static electric power(Pg) and spare power index(Pi) at first and worked-out reasonable procedure,then we designed available detecting-tools and determined the Pmax,Pg and Pi.Results:We detected 3 sets of UHS from domestic or overseas makers and acquired Pmax,Pg and Pi successfully.The results were stable,reproducible and positively correlated to ultrasonic power.Conclusions:The ultrasonic power of UHS is difficult to detect.By the experiment in this paper,detecting ultrasonic power can be replaced by detecting electric power.

5.
Chinese Medical Equipment Journal ; (6)1989.
Article Dans Chinois | WPRIM | ID: wpr-590645

Résumé

Objective To study the measuring method for amplitude of transducer's tip in ultrasonic surgical apparatus, and design a set of practical detecting system with special data processing technique. Methods The system was consisted of stereomicroscope, CCD camera, etc. The images of amplitude measuring were captured and processed and the result was carried out at last. Results The measurement range for amplitude of transducer’s tip was above 190 ?m, the precision was below 10?m, and the repeatability was also ideal. Conclusion The amplitude measuring method has some excellent characters such as directness, simplicity, easy implementation, error estimableness and controllability, etc. It is proved in practice that the effect is nice and the blank in this field in China is filled.