Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Practical Nursing ; (36): 1722-1727, 2021.
Article Dans Chinois | WPRIM | ID: wpr-908145

Résumé

Objective:To study the effect of high flow humidification oxygen inhalation on hypoxemia in patients undergoing cardiac surgery and the effect of postoperative weaning time.Methods:A total of 80 patients with hypoxemia after cardiac surgery from January 2018 to January 2020 were selected for the study, according to the random number table, they were divided into the observation group and the control group, 40 cases each.The control group was treated with noninvasive positive pressure ventilation, while the observation group was treated with high flow humidification and oxygen absorption. The weaning time, the changes of the arterial oxygen partial pressure (PaO 2), partial pressure of carbon dioxide (PaCO 2), oxygenation index (PaO 2/FiO 2), pH value, spontaneous breathing frequency (RR), heart rate before and after treatment 2 h, 6 h, 24 h, and the incidence of complications were compared between the two groups. Results:The weaning time in the observation group was (35.51±4.61) h, and that in the control group was (44.04±3.85) h, the difference was statistically significant( t value was 8.982, P<0.01). The PaO 2 in the observation group at 2, 6, 24 h after treatment were (73.96±4.32), (79.82±3.61), (94.82±2.71) mmHg(1 mmHg=0.133 kPa), and those in the control group were (70.72±3.10), (75.63±3.88), (90.27±3.55) mmHg, the differences were statistically significant( t values were 3.854, 5.000, 6.443, P<0.01). The PaO 2/FiO 2 in the observation group at 2, 6, 24 h after treatment were (239.45±18.74), (269.85±20.09), (291.83±17.30) mmHg, and those in the control group were (226.74±20.72), (251.12±16.74), (279.65±19.40) mmHg, the differences were statistically significant( t values were 2.877, 4.530, 2.964, P<0.01). The RR in the observation group at 2, 6, 24 h after treatment were (24.74±2.03), (22.61±1.86), (18.63±2.05) times/min, and those in the control group were (26.07±1.89), (24.24±1.73), (20.11±1.87) times/min, the differences were statistically significant( t values were 3.033, 4.058, 3.373, P<0.01). The heart rate in the observation group at 2, 6, 24 h after treatment were (83.32±4.88), (76.06±4.71), (70.34±3.82) times/min, and those in the control group were (86.06±3.29), (80.91±4.31), (75.71±6.22) times/min, the differences were statistically significant( t values were 2.944, 4.805, 4.653, P<0.01). The total incidence of complications in the observation group was 7.50%(3/40), and that in the control group was 25.00%(10/40), the difference was statistically significant( χ 2 value was 4.501, P<0.05). Conclusions:High flow humidification and oxygen absorption is well for patients with hypoxemia after cardiac surgery, which effectively improve the blood gas index, shorten the weaning time, reduce the incidence of complications, and have good safety, which is worth popularizing.

SÉLECTION CITATIONS
Détails de la recherche