Journal of Practical Radiology ; (12): 1129-1132, 2014.
Article de Chinois | WPRIM | ID: wpr-452595

RÉSUMÉ

Objective To explore the application value of 320-slice spiral CT myocardial perfusion technique in the evaluation of cardiac function in patients with coronary artery disease.Methods 24 patients with known reversible myocardial ischemia with coro-nary heart disease and 13 cases of normal were detected by 320-slice spiral CT myocardial perfusion scan in resting and after dobu-tamine-induced stress,measured the values of cardiac function indexes(ESV、EDV、SV、EF)in resting and after dobutamine-induced stress respectively,the results were analyzed by paired t test and independent sample t test,when the P value is less than 0.05,con-sidered statistically significant or correlation.Results The values of cardiac function indexes (ESV,EDV,SV)between the resting and after dobutamine-induced stress were significantly different except EF value in normal group.But only the EF value was signifi-cantly different in CHD,the rest values of cardiac function indexes(ESV,EDV,SV)no significant difference.Each corresponding value of cardiac function indexes in resting and after dobutamine-induced stress was significantly different between the CHD and the normal.Conclusion The dobutamine-induced stress myocardial perfusion with 320-slice spiral CT can judge the impaired degree of cardiac function in patients with myocardial ischemia,provide the basis for comprehensive evaluation of coronary artery disease and its prognosis.