1.
Dental press j. orthod. (Impr.) ; 29(1): e2423195, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1534312

Résumé

ABSTRACT Introduction: Surgically assisted rapid palatal expansion (SARPE) has been the treatment of choice in subjects presenting skeletally mature sutures. Objective: The purpose of this study was to analyze stress distribution and displacement of the craniofacial and dentoalveolar structures resulting from three types of palatal expanders with surgical assistance using a non-linear finite element analysis. Material and Methods: Three different palatal expanders were designed: Model-I (tooth-bone-borne type containing four miniscrews), Model-II (tooth-bone-borne type containing two miniscrews), and Model-III (bone-borne type containing four miniscrews). A Le Fort I osteotomy was performed, and a total of 5.0 mm palatal expansion was simulated. Nonlinear analysis (three theory) method (geometric nonlinear theory, nonlinear contact theory, and nonlinear material methods) was used to evaluate stress and displacement of several craniofacial and dentoalveolar structures. Results: Regardless of the maxillary expander device type, surgically assisted rapid palatal expansion produces greater anterior maxillary expansion than posterior (ANS ranged from 2.675 mm to 3.444 mm, and PNS ranged from 0.522 mm to 1.721 mm); Model-I showed more parallel midpalatal suture opening pattern - PNS/ANS equal to 54%. In regards to ANS, Model-II (1.159 mm) and Model-III (1.000 mm) presented larger downward displacement than Model-I (0.343 mm). PNS displaced anteriorly more than ANS for all devices; Model-III presented the largest amount of forward displacement for PNS (1.147 mm) and ANS (1.064 mm). All three type of expanders showed similar dental displacement, and minimal craniofacial sutures separation. As expected, different maxillary expander designs produce different primary areas and levels of stresses (the bone-borne expander presented minimal stress at the teeth and the tooth-bone-borne expander with two miniscrews presented the highest). Conclusions: Based on this finite element method/finite element analysis, the results showed that different maxillary expander designs produce different primary areas and levels of stresses, minimal displacement of the craniofacial sutures, and different skeletal V-shape expansion.


RESUMO Introdução: A expansão rápida da maxila assistida cirurgicamente (ERMAC) tem sido o tratamento de escolha em indivíduos que apresentam suturas esqueleticamente maduras. Objetivo: O objetivo deste estudo foi avaliar, utilizando uma análise não linear com elementos finitos, a distribuição de tensões e os deslocamentos das estruturas craniofaciais e dentoalveolares gerados por três tipos de expansores palatinos usados na ERMAC. Material e Métodos: Três tipos de expansores palatinos foram projetados: Modelo I (dento-osseossuportado com quatro mini-implantes), Modelo II (dento-osseossuportado com dois mini-implantes) e Modelo III (osseossuportado com quatro mini-implantes). Uma osteotomia Le Fort I foi realizada e foi simulada uma expansão palatina total de 5,0 mm. Um método de análise não linear (três teorias - teoria da não-linearidade geométrica, teoria do contato não linear e métodos para materiais não lineares) foi utilizado para avaliar a tensão e o deslocamento de diversas estruturas craniofaciais e dentoalveolares. Resultados: Independentemente do tipo de aparelho expansor palatino, a ERMAC produziu maior expansão anterior da maxila do que posterior (ENA variou de 2,675 mm a 3,444 mm e ENP variou de 0,522 mm a 1,721 mm); o Modelo I apresentou padrão de abertura mais paralela da sutura palatina mediana, com ENP/ENA igual a 54%. Com relação à ENA, o Modelo II (1,159 mm) e o Modelo III (1,000 mm) apresentaram maior deslocamento para baixo do que o Modelo I (0,343 mm). A ENP deslocou-se mais para anterior do que a ENA com todos os aparelhos; o Modelo III apresentou o maior deslocamento para anterior da ENP (1,147 mm) e da ENA (1,064 mm). Os três tipos de expansores apresentaram deslocamento dentário semelhante e separação mínima das suturas craniofaciais. Como esperado, diferentes designs de expansores palatinos produzem diferentes áreas primárias e níveis de tensões (o expansor osseossuportado apresentou tensão mínima nos dentes, e o expansor dento-osseossuportado com dois mini-implantes apresentou o maior). Conclusões: Com base nesse estudo de elementos finitos, os resultados mostraram que diferentes designs de expansores palatinos produzem diferentes áreas primárias e níveis de tensão, com deslocamento mínimo das suturas craniofaciais e diferentes expansões esqueléticas em forma de V.

2.
Braz. dent. sci ; 27(2): 1-12, 2024. ilus, tab
Article Dans Portugais | LILACS, BBO | ID: biblio-1551332

Résumé

Objective: In response to the demand for dental implants, extensive research has been conducted on methods for transferring load to the surrounding bone. This study aimed to evaluate the stresses on the peripheral bone, implants, and prostheses under scenarios involving of the following variables: prosthesis designs, vertical bone heights, load angles, and restorative materials. Material and Methods: Three implants were inserted in the premolar and molar regions (5-6-7) of the two mandibular models. Model 1 represented 0 mm marginal bone loss and Model 2 simulated 3 mm bone loss. CAD/CAM-supported materials, hybrid ceramic (HC), resin-nano ceramic (RNC), lithium disilicate (LiSi), zirconia (Zr), and two prosthesis designs (splinted and non-splinted) were used for the implant-supported crowns. Forces were applied vertically (90°) to the central fossa and buccal cusps and obliquely (30°) to the buccal cusps only. The stresses were evaluated using a three-dimensional Finite Element Analysis. Results: Oblique loading resulted in the highest stress values. Of the four materials, RNC showed the low stress in the restoration, particularly in the marginal area. The use of different restorative materials did not affect stress distribution in the surrounding bone. The splinted prostheses generated lower stress magnitude on the bone, and while more stress on the implants were observed. Conclusion: In terms of the stress distribution on the peri-implant bone and implants, the use of different restorative materials is not important. Oblique loading resulted in higher stress values, and the splinted prosthesis design resulted in lower stress (AU)


Objetivo: Em resposta à demanda por implantes dentários, extensa pesquisa foi realizada sobre métodos para transferir carga ao osso circundante. Este estudo buscou avaliar os estresses no osso periférico, implantes e próteses em cenários que envolvem as seguintes variáveis: designs de próteses, alturas ósseas verticais, ângulos de carga e materiais restauradores. Material e Métodos: Três implantes foram inseridos nas regiões dos pré-molares e molares (5-6-7) de dois modelos de mandíbula. O Modelo 1 representou perda óssea marginal de 0 mm e o Modelo 2 simulou perda óssea de 3 mm. Materiais suportados por CAD/CAM, cerâmica híbrida (HC), cerâmica nano-resina (RNC), dissilicato de lítio (LiSi), zircônia (Zr) e dois designs de próteses (sintetizadas e não-sintetizadas) foram utilizados para as coroas suportadas por implantes. Forças foram aplicadas verticalmente (90°) à fossa central e cúspides bucais e obliquamente (30°) apenas às cúspides bucais. Os estresses foram avaliados usando Análise de Elementos Finitos tridimensional. Resultados: Cargas oblíquas resultaram nos valores mais altos de estresse. Entre os quatro materiais, RNC mostrou baixo estresse na restauração, especialmente na área marginal. O uso de diferentes materiais restauradores não afetou a distribuição de estresse no osso circundante. Próteses sintetizadas geraram menor magnitude de estresse no osso, enquanto mais estresse nos implantes foi observado. Conclusão: Em termos de distribuição de estresse no osso peri-implantar e implantes, o uso de diferentes materiais restauradores não é crucial. Cargas oblíquas resultaram em valores mais altos de estresse, e o design de prótese sintetizada resultou em menor estresse. (AU)


Sujets)
Implants dentaires , Prothèses dentaires , Analyse des éléments finis , Phénomènes biomécaniques
3.
São José dos Campos; s.n; 2024. 81 p. ilus, tab.
Thèse Dans Portugais | LILACS, BBO | ID: biblio-1552084

Résumé

O objetivo deste estudo foi avaliar o comportamento biomecânico através da resistência à fadiga e análise por elementos finitos de coroas bioinspiradas bilaminadas com infraestruturas modificadas na superfície vestibular (Estudo A) e utilizando diferentes materiais cerâmicos com módulos elásticos distintos (Estudo B). Para isso, foram confeccionados 90 preparos para coroa total em resina epóxi G10, sobre os quais foram preparadas coroas bioinspiradas de acordo com os seguintes grupos: Estudo A - IC (infraestrutura convencional), IME (infraestrutura modificada estratificada) e IMC (infraestrutura modificada cimentada), todas confeccionadas em dissilicato de lítio (infraestrutura) + porcelana (recobrimento); Estudo B ­ DL+LEU (dissilicato de lítio + leucita), LEU+DL (leucita + dissilicato de lítio), CH+DL (cerâmica híbrida + dissilicato de lítio) e CH+LEU (cerâmica híbrida + leucita). Para o Estudo A, todas as infraestruturas foram usinadas; os recobrimentos dos grupos IC e IME foram confeccionados através da estratificação, e os recobrimentos do grupo IMC foram usinados. Já para o Estudo B, todas as peças foram usinadas, de acordo com o material cerâmico de cada grupo. Em seguida, foi realizada a cimentação adesiva dos recobrimentos sobre as infraestruturas (a depender do grupo) e das coroas sobre os preparos utilizando cimento resinoso fotopolimerizável (Variolink Esthetic LC). Após a cimentação, os espécimes foram submetidos ao teste de fadiga cíclica (10.000 ciclos, 20Hz), e como desfecho foram considerados dois eventos, em que o primeiro foi a ocorrência de trinca e/ou lascamento (evento 1) e o segundo foi a falha catastrófica do conjunto (evento 2). Os valores de carga e número de ciclos para falha em que foram observados os eventos 1 e 2 foram utilizados para realizar a análise de sobrevivência de acordo com Kaplan-Meier e Log-Rank (Mantel-Cox; 95%). As marcas de fratura e o modo de falha das coroas foram avaliados e classificados por estereomicroscópio óptico e microscópio eletrônico de varredura. Por fim, foi realizada análise por elementos finitos (FEA) para ambos os estudos, a fim de avaliar a distribuição de tensões sobre as coroas e interface adesiva. Para o Estudo A, os resultados do teste de fadiga mostraram que, considerando o evento 1 (trinca/lascamento), os grupos IC e IMC apresentaram médias de carga fadiga estatisticamente significantes entre si (733,33 N e 913,33 N, respectivamente), enquanto o grupo IME apresentou média superior (1.020 N). O mesmo foi observado para o número de ciclos em fadiga para todos os grupos. Ao considerar o evento 2 (falha catastrófica), os três grupos apresentaram médias estatisticamente semelhantes entre si (~1.028 N). Os resultados de FEA mostraram que o grupo IC concentrou maior tensão de tração do que os grupos IME e IMC. Para o Estudo B, no teste de fadiga, o grupo DL+LEU apresentou a maior média de resistência à fadiga (evento 1: 913,33 N e evento 2: 1033,33 N), enquanto todas as outras combinações de materiais cerâmicos analisadas foram estatisticamente semelhantes entre si, considerando carga e número de ciclos. Com relação ao FEA, os grupos com cerâmica híbrida (CH+DL e CH+LEU) apresentaram menores picos de concentração de tensão na infraestrutura do que os grupos com cerâmicas vítreas (DL+LEU e LEU+DL), porém, em contrapartida, concentraram maior tensão na interface adesiva. Com isso, conclui-se que a utilização da infraestrutura modificada é uma alternativa viável e promissora para tratamentos reabilitadores, apresentando sobrevivência em fadiga e distribuição de tensões satisfatórias. Além disso, a combinação entre uma infraestrutura de dissilicato de lítio e recobrimento de cerâmica a base de leucita corresponde a melhor abordagem considerando a infraestrutura modificada.(AU)


The objective of this study was to evaluate the biomechanical behavior through fatigue resistance and finite element analysis of bilaminar bioinspired crowns with modified infrastructures on the buccal surface (Study A) and using different ceramic materials with different elastic moduli (Study B). For this, 90 preparations were made for a full crown in G10 epoxy resin, on which bioinspired crowns were prepared according to the following groups: Study A - CI (conventional infrastructure), SMI (stratified modified infrastructure) and CMI (cemented modified infrastructure ), all made of lithium disilicate (infrastructure) + porcelain (veneer); Study B ­ LD+LEU (lithium disilicate + leucite), LEU+LD (leucite + lithium disilicate), HC+LD (hybrid ceramic + lithium disilicate) and HC+LEU (hybrid ceramic + leucite). For Study A, all infrastructures were machined; the coverings of the CI and SMI groups were made through stratification technique, and the veneers of the SMI group were machined. For Study B, all pieces were machined, according to the ceramic material of each group. Then, the veneers were cemented into their infrastructures (depending on the group) and crowns were cemented into preparations using light-cured resin cement (Variolink Esthetic LC). After cementing, the specimens were subjected to the cyclic fatigue test (10,000 cycles, 20Hz), and as an outcome two events were considered: the occurrence of cracking and/or chipping (event 1) and catastrophic failure (event 2). The load (N) and number of cycles to failure in which events 1 and 2 were observed were used to perform the survival analysis according to Kaplan-Meier and Log-Rank (Mantel- Cox; 95%). The fracture marks and failure mode of the crowns were evaluated and classified by optical stereomicroscope and scanning electron microscope. Finally, finite element analysis (FEA) was performed for both studies in order to evaluate the stress distribution over the crowns and adhesive interface. For Study A, the results of the fatigue test showed that, considering event 1 (cracking/chipping), the CI and CMI groups presented average to failure that were statistically significant compared to each other (733.33 N and 913.33 N, respectively), while the SMI group showed higher averages (1,020 N). Same pattern was observed for the number of cycles under fatigue for both groups. When considering event 2 (catastrophic failure), the three groups presented statistically similar means (~1,028 N). The FEA results showed that the CI group concentrated greater tensile stress than the CMI and SMI groups. For Study B, in the fatigue test, the LC+LEU group presented the highest average fatigue resistance (event 1: 913.33 N and event 2: 1033.33 N), while all other combinations of ceramic materials analyzed were statistically similar to each other, considering load and number of cycles. Regarding FEA, the groups with hybrid ceramics (HC+LC and HC+LEU) showed lower stress concentration peaks in the infrastructure than the groups with glass ceramics (LC+LEU and LEU+LC), however, on the other hand, concentrated greater tension at the adhesive interface. With this, it is concluded that the use of modified infrastructure is a viable and promising alternative for oral rehabilitation treatments, presenting satisfactory fatigue survival and adequate stress distribution. Furthermore, the combination of a lithium disilicate infrastructure and a leucite-based ceramic coating corresponds to the best approach considering the modified infrastructure.(AU)


Sujets)
Céramiques , Analyse des éléments finis , Biomimétique , Prothèse partielle fixe , Fatigue
4.
Acta Anatomica Sinica ; (6): 88-97, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1015151

Résumé

Objective To study the stress change characteristics of the cervical disc after removing different ranges of the uncinate process by establishing a three⁃dimensional finite element model of the C

5.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 188-195, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1006520

Résumé

Objective@#To explore the effect of different miniscrew placement heights on the distribution of biological forces produced by clear aligner combined with intramaxillary traction for mandibular molar distalization, to identify the miniscrew location that is conducive to the protection of lower anterior tooth anchorage and to provide a reference that can be used when designing clinical treatments.@*Methods@#Mimics, GeomagicStudio 2017, SolidWorks 2016, and Ansys workbench were used to establish finite element analysis models and perform mechanical analysis under the following six working conditions: working condition 1 was the control group without miniscrews; working conditions 2 to 5 had miniscrew in the buccal bone cortex between the first and second molars of the lower jaw 10 mm, 7 mm, 4 mm, and 1 mm from the top of the alveolar crest, respectively; working condition 6 had the miniscrew in the center of the buccal tongue at the anterior edge of the ascending branch of the lower jaw 5 mm above the occlusal plane.@*Results@#On the sagittal axis, miniscrew anchorage caused distal displacement of all teeth. Compared to the control group, in the miniscrew group, the displacement of the anterior molars exceeded that of the second molars. On the vertical axis, the result in the control group was similar to backward bending; the results in the miniscrew groups resembled the effect of a lever, lowering the lateral incisors and canines and raising the central incisors and first premolars. On the coronal axis, the second premolars and the first molars showed lingual displacement in the control group, and only the premolars and first molars showed lingual displacementin the miniscrew groups. The canines were the teeth that were most strongly affected by the change in miniscrew placement height.@*Conclusion@#The higher the miniscrew position is, the stronger the protective effect on the anterior anchorage. According to the miniscrew placement height, the mandibular arch should be properly narrowed, the central incisors and first premolars should be lowered, and the lateral incisors and canines should be raised when designing clinical treatments.

6.
International Eye Science ; (12): 62-66, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1003507

Résumé

The finite element method(FEM)is a widely employed mathematical technique in mechanical research that divides an object into discrete and interacting finite elements. Medically, finite element analysis(FEA)enables the simulation of biomechanical experiments that are challenging to conduct. Orbital surgery poses significant challenges to ophthalmologists due to its inherent difficulty and steep learning curve. FEM enables the simulation and analysis of the mechanical properties of orbital tissue, offering a novel approach for diagnosing and treating orbital-related diseases. With technological advancements, FEM has significantly matured in the diagnosis and treatment of orbital diseases, becoming a popular area of research in orbital biomechanics. This paper reviewed the latest advancements in orbital FEM, encompassing the development of orbital FEA models, simulation of orbital structure, and its application in orbital-related diseases. Additionally, the limitations of FEM and future research directions are also discussed. As a digital tool for auxiliary diagnosis and treatment, orbital FEA will progressively unlock its potential for diagnosing and treating orbital diseases alongside technological advancements.

7.
Braz. oral res. (Online) ; 38: e010, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1557356

Résumé

Abstract: This study evaluated the stress distribution in the dentoalveolar and palatal bone structures during maxillary expansion in a 17-year-old male patient with bilateral cleft lip and palate (BCLP) using expanders with dental (HYRAX) and skeletal anchorage (MARPE). For the generation of the specific finite element models, cone-beam computed tomography was used, and the DICOM files were exported to Mimics 3-Matic (Materialise) and Patran (MSC Software) software. Three specific three-dimensional models were generated: A) HYRAX: conventional four-banded hyrax screw (9 mm); B) MARPE-DS: 3 miniscrews (1.8 mm diameter - 5.4 mm length) and four-banded dental anchorage; and C) MARPE-NoDS: 3 miniscrews without dental anchorage. Maxillary expansion was simulated by activating the expanders transversely 1 mm on the "X" axis. HYRAX resulted in higher levels of deformation predominantly in the dentoalveolar region. MARPE-DS showed stress in the dentoalveolar region and mainly in the center of the palatal region, at approximately 4,000 με. MARPE-NoDS exhibited evident stress only in the palatal region. High stress levels in the root anchoring teeth were observed for HYRAX and MARPE-DS. In contrast, MARPE-NoDS cause stress on the tooth structure. The stress distribution from the expanders used in the BLCP showed asymmetric expansive behavior. During the initial activation phase of expansion, the HYRAX and MARPE-DS models produced similarly high strain at the dentoalveolar structures and upper posterior teeth displacement. The MARPE-NoDS model showed restricted strain on the palate.

8.
J. appl. oral sci ; 32: e20230439, 2024. tab, graf
Article Dans Anglais | LILACS-Express | LILACS | ID: biblio-1558238

Résumé

Abstract Objective To evaluate the effect of the labiolingual diameter and construction of an endodontically treated (ET) anterior tooth with crown restoration on stress distribution and biomechanical safety under occlusal loading. Methodology Three-dimensional finite element models were generated for maxillary central incisors with all-ceramic crown restorations. The labiolingual diameters of the tooth, defined as the horizontal distance between the protrusion of the labial and lingual surfaces, were changed as follows: (D1) 6.85 mm, (D2) 6.35 mm, and (D3) 5.85 mm. The model was constructed as follows: (S0) vital pulp tooth; (S1) ET tooth; (S2) ET tooth with a 2 mm ferrule, restored with a fiber post and composite resin core; (S3) ET tooth without a ferrule, restored with a fiber post and composite resin core. A total of 12 models were developed. In total, two force loads (100 N) were applied to the crown's incisal edge and palatal surface at a 45° oblique angle to the longitudinal axis of the teeth. The Von Mises stress distribution and maximum stress of the models were analyzed. Results Regardless of the loading location, stress concentration and maximum stress (34.07~66.78MPa) in all models occurred in the labial cervical 1/3 of each root. Both labiolingual diameter and construction influenced the maximum stress of the residual tooth tissue, with the impact of the labiolingual diameter being greater. A reduction in labiolingual diameter led to increased maximum stress throughout the tooth. The ferrule reduced the maximum stress of the core of S2 models (7.15~10.69 MPa), which is lower compared with that of S3 models (19.45~43.67 MPa). Conclusion The labiolingual diameter exerts a greater impact on the biomechanical characteristics of ET anterior teeth with crown restoration, surpassing the influence of the construction. The ferrule can reduce the maximum stress of the core and maintain the uniformity of stress distribution.

9.
China Journal of Orthopaedics and Traumatology ; (12): 57-60, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009223

Résumé

OBJECTIVE@#To compare the biomechanical stability of three cross-bridge headless compression screws and locking plates in the fixation of Mason type Ⅲ radial head fractures by finite element method.@*METHODS@#Using reverse modeling technology, the radial CT data and internal fixation data of a healthy 25-year-old male were imported into the relevant software. Three-dimensional finite element model of 3 cross-bridge headless compression screws and locking plates for MasonⅢ radial head fractures were established, and the radial head was loaded with 100 N axial loading. The maximum displacement, maximum Von Mises stress and stress distribution of the two groups were compared.@*RESULTS@#The maximum displacements of the three cross-bridge screws group and locking plate group were 0.069 mm and 0.087 mm respectively, and the Von Mises stress peaks were 18.59 MPa and 31.85 MPa respectively. The stress distribution of the three screws group was more uniform.@*CONCLUSION@#Both internal fixation methods can provide good fixation effect. CoMPared with the locking plate fixation method, the 3 cross-bridge headless compression screws fixation is more stable and the stress distribution is more uniform.


Sujets)
Mâle , Humains , Adulte , Analyse des éléments finis , , Vis orthopédiques , Phénomènes biomécaniques , Fractures du radius/chirurgie , Ostéosynthèse interne/méthodes , Plaques orthopédiques , Fractures comminutives
10.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 17-25, abr./jun 2023. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1537357

Résumé

Introdução: A osteotomia Le Fort I possibilita a correção de deformidades dentofaciais que envolvem o terço médio da face. Para sua fixação, convencionou-se o emprego de quatro mini-placas nos pilares zigomático-maxilar e nasomaxilar. Propôs-se então, a dispensa da fixação do segmento posterior, surgindo questionamentos relacionados à capacidade biomecânica do sistema. Objetivos: Comparar o estresse biomecânico gerado em três meios distintos de fixação da osteotomia Le Fort I frente ao movimento de avanço sagital linear maxilar de 7mm. Metodologia: Trata-se de uma pesquisa experimental laboratorial, utilizando-se da análise de elementos finitos como ferramenta analítica, a fim de constatar qual das técnicas sofrerá maior estresse biomecânico. Resultados: Constatou-se que o estresse biomecânico gerado é maior quando aplicado em 4 pontos do que quando aplicado em apenas 2 pontos. Conclusão: Os resultados obtidos fornecem informações aos cirurgiões sobre a real necessidade do uso de fixação adicional de acordo com o método de fixação planejado. No entanto, deve ser interpretado de forma cautelosa, considerando-se as limitações deste estudo. Sendo assim, uma análise incipiente, que tem como intuito o fornecimento de evidência científica de grande significância.


Introducción: La osteotomía Le Fort I permite la corrección de deformidades dentofaciales que involucran el tercio medio de la cara. Para su fijación se acordó utilizar cuatro miniplacas en los pilares cigomaticomaxilar y nasomaxilar. Entonces se propuso prescindir de la fijación del segmento posterior, planteando interrogantes relacionados con la capacidad biomecánica del sistema. Objetivos: Comparar el estrés biomecánico generado en tres medios diferentes de fijación de la osteotomía Le Fort I frente a un movimiento de avance sagital lineal maxilar de 7mm. Metodología: Se trata de una investigación experimental de laboratorio, utilizando como herramienta analítica el análisis de elementos finitos, con el fin de comprobar cuál de las técnicas sufrirá un mayor estrés biomecánico. Resultados: Se encontró que el estrés biomecánico generado es mayor cuando se aplica en 4 puntos que cuando se aplica solo en 2 puntos. Conclusión: Los resultados obtenidos brindan información a los cirujanos sobre la necesidad real de utilizar fijación adicional de acuerdo al método de fijación planificado. Sin embargo, debe interpretarse con cautela, considerando las limitaciones de este estudio. Por tanto, un análisis incipiente, que pretende aportar evidencias científicas de gran trascendencia.


Introduction: The Le Fort I osteotomy allows the correction of dentofacial deformities involving the middle third of the face. For its fixation, it was agreed to use four mini plates on the zygomaticomaxillary and nasomaxillary pillars. It was then proposed to dispense with the fixation of the posterior segment, raising questions related to the biomechanical capacity of the system. Objectives: To compare the biomechanical stress generated in three different means of fixation of the Le Fort I osteotomy against a 7mm maxillary linear sagittal advancement movement. Methodology: This is an experimental laboratory research, using finite element analysis as an analytical tool, in order to verify which of the techniques will suffer greater biomechanical stress. Results: It was found that the biomechanical stress generated is greater when applied to 4 points than when applied to only 2 points. Conclusion: The results obtained provide information to surgeons about the real need to use additional fixation according to the planned fixation method. However, it should be interpreted with caution, considering the limitations of this study. Therefore, an incipient analysis, which aims to provide scientific evidence of great significance.


Sujets)
Ostéotomie de Le Fort , Analyse des éléments finis , Chirurgie orthognathique , Ostéosynthèse interne
11.
Int. j. morphol ; 41(5): 1288-1296, oct. 2023. ilus, tab
Article Dans Espagnol | LILACS | ID: biblio-1521049

Résumé

El propósito de este estudio fue analizar el comportamiento mecánico de la estructura dental sana de un primer premolar inferior humano sometido a fuerzas funcionales y disfuncionales en diferentes direcciones. Se buscó comprender, bajo las variables contempladas, las zonas de concentración de esfuerzos que conllevan al daño estructural de sus constituyentes y tejidos adyacentes. Se realizó el modelo 3D de la reconstrucción de un archivo TAC de un primer premolar inferior, que incluyó esmalte, dentina, ligamento periodontal y hueso alveolar considerando tres variables: dirección, magnitud y área de la fuerza aplicada. La dirección fue dirigida en tres vectores (vertical, tangencial y horizontal) bajo cuatro magnitudes, una funcional de 35 N y tres disfuncionales de 170, 310 y 445 N, aplicadas sobre un área de la cara oclusal y/o vestibular del premolar que involucró tres contactos estabilizadores (A, B y C) y dos paradores de cierre. Los resultados obtenidos explican el fenómeno de combinar tres vectores, cuatro magnitudes y un área de aplicación de la fuerza, donde los valores de esfuerzo efectivo equivalente Von Mises muestran valores máximos a partir de los 60 MPa. Los valores de tensión máximos se localizan, bajo la carga horizontal a 170 N y en el proceso masticatorio en la zona cervical, cuando la fuerza pasa del 60 %. Sobre la base de los hallazgos de este estudio, se puede concluir que la reacción de los tejidos a fuerzas funcionales y disfuncionales varía de acuerdo con la magnitud, dirección y área de aplicación de la fuerza. Los valores de tensión resultan ser más altos bajo la aplicación de fuerzas disfuncionales tanto en magnitud como en dirección, produciendo esfuerzos tensiles significativos para la estructura dental y periodontal cervical, mientras que, bajo las cargas funcionales aplicadas en cualquier dirección, no se generan esfuerzos lesivos. Esto supone el reconocimiento del poder de detrimento estructural del diente y periodonto frente al bruxismo céntrico y excéntrico.


SUMMARY: The purpose of this study was to analyze the mechanical behavior of the healthy dental structure of a human mandibular first premolar subjected to functional and dysfunctional forces in different directions. It was sought to understand, under the contemplated variables, the areas of stress concentration that lead to structural damage of its constituents and adjacent tissues. The 3D model of the reconstruction of a CT file of a lower first premolar was made, which included enamel, dentin, periodontal ligament and alveolar bone considering three variables: direction, magnitude and area of the applied force. The direction was directed in three vectors (vertical, tangential and horizontal) under four magnitudes, one functional of 35 N and three dysfunctional of 170, 310 and 445 N, applied to an area of the occlusal and/or buccal face of the premolar that involved three stabilizing contacts (A, B and C) and two closing stops. The results obtained explain the phenomenon of combining three vectors, four magnitudes and an area of force application, where the values of effective equivalent Von Mises stress show maximum values from 60 MPa. The maximum tension values are located under the horizontal load at 170 N and in the masticatory process in the cervical area, when the force exceeds 60%. Based on the findings of this study, it can be concluded that the reaction of tissues to functional and dysfunctional forces varies according to the magnitude, direction, and area of application of the force. The stress values turn out to be higher under the application of dysfunctional forces both in magnitude and in direction, producing significant tensile stresses for the dental and cervical periodontal structure, while under functional loads applied in any direction, no damaging stresses are generated. This supposes the recognition of the power of structural detriment of the tooth and periodontium against centric and eccentric bruxism.


Sujets)
Humains , Prémolaire/physiologie , Phénomènes biomécaniques , Analyse des éléments finis , Dent/physiologie , Force occlusale , Bruxisme/physiopathologie , Module d'élasticité , Usure dentaire , Mastication/physiologie
12.
Int. j. odontostomatol. (Print) ; 17(2): 174-185, jun. 2023. ilus, tab
Article Dans Anglais | LILACS | ID: biblio-1440356

Résumé

This in silico study aimed to evaluate the biomechanical behavior of a full-arch implant-supported prosthesis on titanium and zirconia monotype implants. A 3D mandible containing 1.0 mm thick cortical and cancellous bone was modeled. Four dental implants (3.3 x 10 mm) were inserted into the jaw model in each model. The implants consisted of Titanium (Ti-S group) and Zirconia Monotype/one-piece (Zr-S group). Fixed full-arch implant-supported prostheses were cemented onto the implant. The models were exported to the analysis software and divided into meshes composed of nodes and tetrahedral elements. All materials were considered isotropic, elastic, and homogeneous. Therefore, all contacts were considered bonded, the mandible model was fixed in all directions, applying a static structural axial load of 300 N on the bottom of the fossa of the left mola r teeth. Microstrain and von-Mises stress (MPa) were adopted as failure criteria. Comparable stress and strain values were shown in the peri-implant bone for both groups. However, the Ti-S group presented a lower stress value (1,155.8 MPa) than the Zr-S group (1,334.2 MPa). Regarding bone tissues, the Ti-S group presented 612 µε and the Zr-S group presented 254 µε. The highest strain peak was observed in bone tissues around the implant closer to the load for both groups. Evaluating monotype zirconia and titanium implants, it is suggested that the greater the rigidity of the implant, the greater the concentration of internal stre sses and the less dissipation to the surrounding tissues. Therefore, monotype ceramic implants composed of yttrium-stabilized tetragonal polycrystalline zirconia may be a viable alternative to titanium implants for full-arch prostheses.


El objetivo de este estudio in silico fue evaluar el comportamiento biomecánico de una prótesis implanto soportada de arcada completa sobre implantes monotipo de titanio y zirconia. Se modeló una mandíbula en 3D que contenía tejido óseo cortical y esponjoso de 1,0 mm de espesor. En cada modelo, se insertaron cuatro implantes dentales (3,3 x 10 mm) en el modelo de mandíbula. Los implantes consistieron en Monotipo de Titanio y Zirconia. Sobre el implante se cementaron prótesis implanto soportadas de arcada completa fija. Los modelos se exportaron al software de análisis y se dividieron en mallas compuestas por nodos y elementos tetraédricos. Todos los materiales se consideraron isotrópicos, elásticos y homogéneos. Por lo tanto, todos los contactos se consideraron cementados, el modelo mandibular se fijó en todas las direcciones, aplicando una carga vertical estructural estática de 300 N en el fondo de la fosa de los dientes molares izquierdos. Se seleccionaron la microesfuerzo y la tensión de Von-Mises (MPa) como criterios de falla. Se mostraron valores de tensión y deformación comparables en el hueso periimplantario para ambos grupos. Sin embargo, el grupo Ti-S presentó un valor de estrés menor (1.155,8 MPa) que el grupo Zr-S (1.334,2 MPa). En cuanto a los tejidos óseos, el grupo Ti-S presentó 612 µε y el grupo Zr-S presentó 254 µε. La mayor concentración de deformación en el tejido óseo se observó en los tejidos alrededor del implante más cerca de la carga para ambos grupos. Al evaluar los implantes monotípicos de zirconia y titanio, se sugiere que cuanto mayor sea la rigidez del implante, mayor será la concentración de tensiones internas y menor la disipación a los tejidos circundantes. Por lo tanto, los implantes cerámicos monotipo compuestos de zirconia policristalina tetragonal estabilizada con itrio pueden ser una alternativa viable a los implantes de titanio para prótesis de arcada completa.


Sujets)
Implants dentaires , Matériaux dentaires , Contrainte mécanique , Phénomènes biomécaniques , Analyse des éléments finis , Mandibule/imagerie diagnostique
13.
Kinesiologia ; 42(2): 127-131, 20230615.
Article Dans Espagnol , Anglais | LILACS-Express | LILACS | ID: biblio-1552472

Résumé

Objetivo. Analizar el rendimiento biomecánico de las placas de tibia proximal utilizadas en fracturas de platillos tibiales evaluado a través de modelos de elementos finitos. Métodos. Se realizará una búsqueda exhaustiva en PubMed/Medline, Embase, Lilacs, Web of Science y Google Scholar. No se utilizará ninguna restricción de idioma o estado de publicación. Dos revisores examinarán de forma independiente los posibles artículos elegibles, de acuerdo con los criterios de selección predefinidos. Se incluirán los estudios que evalúen el rendimiento de los platillos tibiales proximales utilizados en las fracturas del platillo tibial evaluadas mediante el análisis de elementos finitos. La extracción de datos sobre las características del estudio, los métodos, los resultados y la evaluación del riesgo de sesgo se realizará mediante un formulario estandarizado. Considerando el diseño de estudio no se requiere evaluación por comité de ética. Los resultados de esta revisión se difundirán a través de la publicación en revistas revisadas por pares, redes sociales y congresos de la especialidad. Se espera que los resultados de esta revisión permitan optimizar los resultados del manejo quirúrgico de las fracturas de platillos tibiales. Número de registro PROSPERO: CRD42023396015.


Objetive. To analyze the biomechanical performance of proximal tibial plates used in tibial plate fractures evaluated through finite element modeling. Methods. A comprehensive search will be conducted in PubMed/Medline, Embase, Lilacs, Web of Science, and Google Scholar. No language or publication status restrictions will be used. Two reviewers will independently review potential eligible articles according to predefined selection criteria. Studies evaluating the performance of proximal tibial splints used in tibial splint fractures assessed by finite element analysis will be included. Data extraction on study characteristics, methods, results, and risk of bias assessment will be performed using a standardized form. Considering the study design, evaluation by an ethics committee is not required. The results of this review will be disseminated through publication in peer-reviewed journals, social networks and specialty congresses. It is expected that the results of this review will allow optimizing the results of the surgical management of tibial plate fractures. PROSPERO registration number: CRD42023396015.

14.
Braz. dent. j ; 34(6): 140-149, 2023. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1528038

Résumé

Abstract This study aimed to evaluate the influence of material and crown design on the biomechanical behavior of implant-supported crowns with hybrid abutment (HA) through three-dimensional (3D) finite element analysis. The study factors were the type of material used as the mesostructure or crown (zirconia, lithium disilicate, and hybrid ceramic) and the crown design cemented to the titanium base (mesostructure cemented to the titanium base and a crown cemented on it (HaC); hybrid crown-abutment, the abutment and crown are manufactured as a single piece and cemented to the titanium base (HC); monolithic crown cemented on the titanium base and screwed to the implant (CS); and monolithic crown cemented on the titanium base (CC). Four 3D models were constructed using an implant with an internal connection, and an oblique load of 130 N was applied at 45° to the long axis of the implant. The models were evaluated using the von Mises stress for crown, abutment, screw, and implant and maximum principal stress for bone tissues. The lowest stresses occurred in the groups with a lower elastic modulus material, mainly hybrid ceramics, considered a material with greater resilience. The cemented crown group presented the lowest stress values. The stresses were concentrated in the cervical region of the crown at the titanium crown/base interface. Mesostructures made of materials with a higher elastic modulus exhibited a higher concentration of stress. The presence of a screw hole increased the stress concentration in the ceramic crown. Cemented ceramic crowns exhibited better biomechanical behavior than screw-retained crowns.


Resumo O estudo teve como objetivo avaliar a influência do material e do desenho da coroa no comportamento biomecânico de coroas implanto-suportadas com pilar híbrido (AH) por meio da análise tridimensional (3D) de elementos finitos. Os fatores de estudo foram o tipo de material do HA ou coroa (zircônia, dissilicato de lítio e cerâmica híbrida) e o desenho da coroa sobre a base de titânio (mesoestrutura cimentada à base de titânio e coroa total cimentada em cerâmica; pilar e coroa fabricados em peça única cimentada à base de titânio; coroa monolítica cimentada sobre a base de titânio e aparafusada ao implante; e coroa monolítica cimentada à base de titânio). Quatro modelos 3D foram construídos e uma carga oblíqua de 130 N foi aplicada a 45° em relação ao longo eixo do dente. Os modelos foram avaliados utilizando a tensão de von Mises para a coroa, pilar, parafuso, implante e tensão principal máxima (tensão de tração) para o tecido ósseo. As menores tensões ocorreram nos grupos que apresentaram um material com menor módulo de elasticidade, principalmente a cerâmica híbrida, considerada um material com maior resiliência. Com relação às diferentes configurações, o modelo com coroa cimentada apresentou os menores valores de tensão. As tensões foram concentradas na região cervical da coroa na interface entre coroa e base de titânio. Mesoestruturas feitas de materiais com maior módulo de elasticidade exibiram maior concentração de tensões. A presença de um orifício para parafuso aumentou a concentração de tensão na coroa de cerâmica. As coroas cerâmicas cimentadas exibiram melhor comportamento biomecânico do que as coroas parafusadas.

15.
RGO (Porto Alegre) ; 71: e20230055, 2023. graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1521438

Résumé

ABSTRACT Objective: The present study analyzed the biomechanical behavior of the generated stress on the external surface of the rehabilitation elements (implants, components and infrastructures) according to different occlusion patterns on a fixed partial denture on osseointegrated implants. Method: The experimental groups varied according to the location of the occlusal load applied to the Fixed partial denture, with a total occlusal load of 750N in all groups, opting for greater loads on the occlusal table of the molar in relation to the premolar. This evaluation was performed by the finite element method with simulations by the AnsysWorkbench 16.0 Software program. Results: The results analyzed for implants and their components showed that the more posterior the occlusal loading, the greater the stress developed (group 4), always in the connection area between the prosthetic component and the implant, as this location can induce greater screw loosening. The results analyzed for the infrastructures showed that the most distributed occlusal loading possible (group 1) is the best situation for generating less stress. However, even in group 3 which obtained the highest stresses in the critical area of the prosthetic connection, the zirconia flexural strength values generated were not worrisome. Conclusion: It can be concluded that the occlusal adjustment of Fixed partial dentures are preponderant and decisive factors for correct biomechanics and preservation of the system in the long term in order to avoid possible damage and/or failures, and exert significant and notorious differences in the behavior of all structures studied herein.


RESUMO Objetivo: O presente estudo analisou o comportamento biomecânico do estresse gerado na superfície externa dos elementos reabilitadores (implantes, componentes e infraestruturas) de acordo com diferentes padrões de oclusão em uma prótese parcial fixa sobre implantes osseointegrados. Métodos: Os grupos experimentais variaram de acordo com a localização da carga oclusal aplicada na Prótese Parcial Fixa, com carga oclusal total de 750N em todos os grupos, optando por cargas maiores na mesa oclusal do molar em relação ao pré-molar. Esta avaliação foi realizada pelo método dos elementos finitos com simulações pelo programa AnsysWorkbench 16.0 Software. Resultados: Os resultados analisados para os implantes e seus componentes mostraram que quanto mais posterior a carga oclusal, maior a tensão desenvolvida (grupo 4), sempre na área de conexão entre o componente protético e o implante, pois este local pode induzir maior soltura do parafuso. Os resultados analisados para as infraestruturas mostraram que a carga oclusal mais distribuída possível (grupo 1) é a melhor situação para gerar menos estresse. No entanto, mesmo no grupo 3 que obteve as maiores tensões na área crítica da conexão protética, os valores de resistência à flexão da zircônia gerados não foram preocupantes. Conclusões: Pode-se concluir que o ajuste oclusal das Próteses Parciais Fixas são fatores preponderantes e decisivos para correta biomecânica e preservação do sistema a longo prazo a fim de evitar possíveis danos e/ou falhas, e exercem diferenças significativas e notórias no comportamento de todas as estruturas aqui estudadas.

16.
Rev. odontol. UNESP (Online) ; 52: e20230027, 2023. tab, ilus
Article Dans Anglais | LILACS, BBO | ID: biblio-1530299

Résumé

Introdução: O conhecimento da biomecânica de implantes de diâmetro reduzido indica dimensões seguras para uso clínico. Objetivo: O objetivo do presente estudo foi comparar biomecanicamente implantes de diâmetro regular e reduzido para suporte de próteses implantossuportadas unitárias na região anterior da maxila por meio de análise de elementos finitos 3D (3D-FEA). Material e método: Quatro modelos 3D-FEA foram desenvolvidos a partir de recomposição de tomografia computadorizada e dados da literatura: um bloco ósseo na região incisiva lateral superior direita com implante e coroa. M1: 3,75 x 13 mm, M2: 3,75 x 8,5 mm, M3: 2,9 x 13 mm e M4: 2,9 x 8,5 mm. Foi aplicada carga de 178 N nos ângulos 0, 30 e 60 graus em relação ao longo eixo do implante. Foram avaliados mapas de tensão de Von Mises, tensão principal máxima e microdeformação. Resultado: M3 e M4 apresentaram maiores valores de tensão e microdeformação que M1 e M2, principalmente quando foram aplicadas forças inclinadas. Porém, M3 apresentou comportamento biomecânico melhor do que M4. Conclusão: Pode-se concluir que reduzir o diâmetro dos implantes pode prejudicar a biomecânica durante a aplicação de forças, mas a distribuição e intensidade das tensões, bem como os valores de microdeformação podem ser melhorados se o comprimento do implante for aumentado


Introduction: Narrow diameter implants biomechanics knowledge indicates safe dimensions for clinical use. Objective: Purpose of the present study was biomechanically to compare regular and narrow diameter implants to support single implant-supported prosthesis in the anterior region of the maxilla by 3D finite element analysis (3D-FEA). Material and method: Four 3D-FEA models were developed form CT scan recompositing and literature data: a bone block in the right upper lateral incisive region with implant and crown. M1: 3.75 x 13 mm, M2: 3.75 x 8.5 mm, M3: 2.9 x 13 mm and M4: 2.9 x 8.5 mm. It was applied load was of 178 N at 0, 30 and 60 degrees in relation to implant long axis. Von Mises stress, maximum principal stress and microdeformation maps were evaluated. Result: M3 and M4 did show higher tension and higher microdeformation values than M1 and M2, especially when inclined forces were applied. However, M3 presented enhanced biomechanical behavior than M4. Conclusion: It can be concluded that reduce the diameter of the implants can disadvantage to the biomechanics during the application of forces, but the distribution and intensity of the stresses, as well as the micro deformation values can be improved if the length of the implant is increased


Sujets)
Prothèses et implants , Contrainte mécanique , Phénomènes biomécaniques , Os et tissu osseux , Implants dentaires , Analyse des éléments finis , Tomodensitométrie , Maxillaire
17.
Journal of Medical Biomechanics ; (6): E465-E471, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987972

Résumé

Objective To study the process of single stent and double-stent thrombectomy at the Y-shaped bifurcation of the ideal internal carotid artery by finite element simulation, analyze the stent-thrombus-vessel interaction during the thrombectomy process based on the simulation results, and provide guidance for improving the effect of stent thrombectomy at the bifurcation. Methods The CAD software was used to build the model and the finite element analysis software was used to simulate the process of single stent and double-stent thrombectomy. Results Thrombectomy was unsuccessful in single stent model and successful in double-stent model, and the maximum stress of thrombus during embolus retrieval was twice that of single stent, the maximum strain was 1.12 times that of single stent, and the maximum contact pressure on the surface of vessel was approximately twice that of single stent. Conclusions Double Solitaire stents can effectively prevent thrombus displacement at the bifurcation and successfully retrieve the thrombus, but there is a risk of fracture due to the high stress level in the middle section of the thrombus. The contact pressure of the vessel on the anterior artery side is higher during thrombectomy, and the risk of vessel damage is greater. Therefore, it is necessary to optimize the design of the stent-retriever to improve its flexibility.

18.
Journal of Medical Biomechanics ; (6): E303-E309, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987951

Résumé

Objective To investigate the relationship between lesion size of solitary bone cyst ( SBC) and pathological fracture of calcaneus, so as to provide references for the treatment of SBC. Methods The three dimensional (3D) finite element model of foot and ankle was established based on CT images. Four models with gradient spherical bone defects were constructed in the focal area to simulate different SBC lesion sizes, and the biomechanical characteristics of calcaneus in different gait phases were analyzed. Results With the increasement of SBC size, the kinematics of calcaneus did not change significantly, but the peak stress of calcaneus increased gradually. When the SBC size exceeded 75% of the calcaneal width, the stress in calcaneal sulcus and cortical bone below SBC increased by 1. 48 times and 7. 74 times, respectively. Conclusions The risk of pathological fracture increases when the SBC diameter exceeds 75% of the calcaneal width, and early surgical intervention should be recommended. The calcaneal sulcus and the cortex bone below SBC are stress concentration regions and can be used as important areas to evaluate pathological fractures.

19.
Journal of Medical Biomechanics ; (6): E276-E282, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987947

Résumé

Objective Aiming at the problem of significant anisotropy in the three-dimensional ( 3D) printed polyether-ether-ketone ( PEEK) bone substitutes manufactured by material extrusion technology, taking the femur, the main load-bearing long bone of the lower limb, as an example, the biomechanical properties of the femoral model under different direction in the build chamber were evaluated by the combination of finite element analysis and in-vitro mechanical experiment. Methods A left femoral model was obtained by reconstruction from CT data. The stress and displacement of the 3D printed PEEK femur with different directions in the build chamber under five physiological postures in the human gait cycle were simulated by varying the orthogonal anisotropy mechanical properties. An in-vitro mechanical experiment was conducted to investigate the safety and stability of the femur through a 3D printed PEEK femur. Results When the long axis of the femur model was perpendicular to the building platform of the 3D printer, a better mechanical property was obtained, and the maximum von Mises stress was 46. 56 MPa, which was lower than the yield stress of PEEK, while the maximum displacement was larger than that of the natural femur under same loading condition. Therefore, the 3D printed PEEK femur met the strength requirement, but the stability needs to be improved. Conclusions The long axis is recommended to be perpendicular to the building platform when the material extrusion technology was used for the substitute of the load-bearing long bone, and the effect of its anisotropy on service performance of the substitute should be carefully considered when the 3D printing technology is used for load-bearing bone substitute.

20.
Journal of Medical Biomechanics ; (6): E097-E103, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987920

Résumé

Objective To perform finite element analysis on a novel motion mode hinged knee prosthesis, and investigate the method of wear simulation on hinged prosthesis and the influence of motion mode on wear of the prosthesis. Methods Based on the finite element model of contact stress on spherical axis prosthesis, the finite element model of wear was established according to Archard wear theory. The kinematics data during different motions were input as loading condition to simulate mechanical environment of the knee arthroplasty in physiological activities. The wear results of spherical axis prosthesis were studied. Results For tibial insert, the average and maximum contact stresses during upstairs and downstairs climbing were higher than those during walking, and the cumulative wear volume during upstairs climbing was larger than that during downstairs climbing and walking. The wear mainly occurred on lower surface of tibial insert during all 3 motions. For rotating bushing, there was only a short period of contact and wear during walking, and the cumulative wear was 0. 19 mm3. Conclusions The spherical axis motion of hinged knee prosthesis can improve the mechanical environment of knee, reduce the wear of rotating bushing, and prolong the prosthesis survival. The finite element simulation can predict the wear of hinged prosthesis effectively, and provide the theoretical basis for design and improvement of the prosthesis.