Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
West China Journal of Stomatology ; (6): 502-505, 2016.
Article Dans Chinois | WPRIM | ID: wpr-317776

Résumé

<p><b>OBJECTIVE</b>Finite elemental analysis of the mechanical characteristics of a first mandibular implant molar under different mandibular plane angles determines the load conditions on the implant, thereby providing guidance for clinical application.</p><p><b>METHODS</b>CT data of three mandibular plane angles (low, average, high) were collected. A finite elemental combination model of a dental implant was constructed. The orthogonal experimental research was designed. Results followed data collection and analysis.</p><p><b>RESULTS</b>The optimal combination was a low angle, 4.8 mm, and type Ⅱ bone. The relations among diameter of the implant, angle of mandibular bone, and bone density were determined.</p><p><b>CONCLUSIONS</b>Mandibular plane angle influences the stability of a dental implant. Under constant biting force, dental implants bear the stress proportional to the angle, high angles cause high stress, average angles cause average stress, and low angles cause the least stress.</p>


Sujets)
Humains , Force occlusale , Implants dentaires , Conception de prothèse dentaire , Analyse du stress dentaire , Analyse des éléments finis , Mandibule , Molaire
2.
Journal of Medical Research ; (12)2006.
Article Dans Chinois | WPRIM | ID: wpr-567402

Résumé

Objective To establish a three-dimensional finite element model and make mechanical analysis of "V"-type atlantoaxial reduction and internal fixation. Methods According to "V"-type atlantoaxial and internal fixation,based on screw-type Ⅱ design parameters,and using Pro/E 2001 and MSC.Patran 2005 software,we set up a finite element model and calculated the region containing the node scope of the force as the sites binding and 100N mechanics adding. Results The model looked realistic,geometric similarity.The deformation stress field mainly concentrated in the reset device V-tip arm bending and stability.The strength of its maximum stress was 4.78MPa,and the scope had 2794 nodes.V-type wing of the acute angle point of convergence of the premises to bear the stress intensity followed.It was 0.31MPa,and the scope had 1953 nodes.V-type wing by the end of edge was the smallest for the 1.22?10-3MPa,and there was the scope of 1730 nodes. Ⅱ-shaped fixed nail stress concentrated at the central parts of tooth and the art on both sides of teeth,with maximum stress intensity of 1.68?10-2MPa,and there was the scope of 1146 nodes. Conclusion The reduction and fixation devices to load at the time of recovery deformation forces and mechanical characteristics adapted to Ni-Ti shape memory alloy material functions and super-elasticity completely,which meets the clinical needs.

SÉLECTION CITATIONS
Détails de la recherche