1.
Military Medical Sciences
;
(12): 17-20,37, 2017.
Article
Dans Chinois
| WPRIM
| ID: wpr-606379
Résumé
Objective To design a controller for the air environment of cabins of special vehicles .Methods The microprocessor was used to collect and store parameters ,and calculate automatically the operative mode of actuators ,such as the fan,air-conditioner,oxygenerator,air cleaner, filtering and boosting devices according to the preset target values .Output commands by RS485 were used to control actuators .Results and Conclusion The controller is capable of control integration for air-adjusting equipment while improving the control effect of the air quality in cabins of special vehicles .