Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 972
Filtre
1.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 50-58, jan.-abr. 2024. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1553265

Résumé

As indicações de tratamento das fraturas mandibulares em paciente pediátrico variam em conservador, fixação não rígida e interna rígida. Alterações no crescimento ósseo, disfunções na articulação temporomandibular e assimetrias faciais podem ser decorrentes ao insucesso do tratamento. O objetivo deste trabalho consiste em relatar abordagem cirúrgica em fratura de sínfise e côndilo mandibular bilateral em paciente pediátrico. Paciente gênero feminino, 09 anos de idade, foi encaminhada ao Hospital Geral do Estado - Bahia vítima de queda de nível, cursando com trauma em face. Apresentou queixa principal, referida pela progenitora, de dificuldades em fechar a boca. Ao exame físico, a paciente apresentou mobilidade atípica à manipulação da mandíbula, mordida aberta anterior, equimose sublingual, ausência das unidades dentárias 74 e 75, com abertura bucal regular e suturas em posição em região de mento. Ao exame de imagem de tomografia computadorizada da face, pôde-se notar sinais sugestivos de fratura em região de sínfise e côndilos mandibulares bilateral. Após diagnóstico das fraturas, a paciente foi submetida à cirurgia sob anestesia geral para redução e fixação das mesmas. Realizou-se acessos em ferimento na região mentual e retromandibular bilateral com posterior síntese das fraturas utilizando fixação interna rígida com placas do sistema 2.0mm, associada a odontossíntese na fratura de sínfise. Ao acompanhamento periódico, a eleição do tratamento cirúrgico para fraturas mandibulares em pacientes pediátricos, pode permitir segurança no crescimento ósseo mandibular e facial(AU)


The indications for treatment of mandibular fractures in pediatric patients vary from conservative, non-rigid fixation and rigid internal fixation. Changes in bone growth, temporomandibular joint disorders and facial asymmetries may be due to treatment failure. The objective of this work is to report a surgical approach to bilateral symphysis and mandibular condyle fractures in a pediatric patient. Female patient, 9 years old, was sent to the State General Hospital - Bahia, victim of a fall in level, suffering from trauma to the face. She presented a main complaint, mentioned by her mother, of difficulties in closing her mouth. On physical examination, the patient presented atypical mobility when manipulating the jaw, anterior open bite, sublingual ecchymosis, absence of dental units 74 and 75, with regular mouth opening and sutures in position in the chin region. When examining the computed tomography image of the face, signs suggestive of fracture in the region of the symphysis and bilateral mandibular condyles were noted. After diagnosis of the fractures, the patient underwent surgery under general anesthesia to reduce and fix them. Access was performed on a wound in the mental and bilateral retromandibular region with subsequent synthesis of the fractures using rigid internal fixation with 2.0mm system plates, associated with odontosynthesis in the symphysis fracture. With periodic monitoring, the choice of surgical treatment for mandibular fractures in pediatric patients can allow for safe mandibular and facial bone growth(AU)


Sujets)
Humains , Femelle , Enfant , Ostéosynthèse interne , Menton/chirurgie , Menton/traumatismes , Condyle mandibulaire/chirurgie , Condyle mandibulaire/traumatismes
2.
China Journal of Orthopaedics and Traumatology ; (12): 86-91, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009228

Résumé

OBJECTIVE@#To investigate the clinical effect of total hip replacement (THA) in the treatment of traumatic arthritis secondary to acetabular fracture.@*METHODS@#From October 2019 to June 2022, 15 patients with secondary traumatic arthritis of acetabulum fracture were treated with THA. There were 8 males and 7 females, aged from 40 to 76 years old with an average of (59.20±9.46) years old. Prosthesis loosening, dislocation of hip joint, range of motion of hip joint, nerve injury and other conditions were recorded before and after surgery. Harris score, visual analogue scale (VAS) and imaging were used to evaluate hip joint function and surgical effect.@*RESULTS@#Follow-up time ranged 6 to 39 months with an average of (18.33±9.27) months. All the 15 patients successfully completed the operation, no nerve and blood vessel injury during the operation, postoperative wound healing was stageⅠ, no infection, one case of acetabular side prosthesis loosening at half a year after operation, and recovered well after revision surgery, one case of hip dislocation was cured after open reduction treatment, no adverse consequences. Harris score at the last postoperative follow-up was (88.60±4.01) points, compared with the preoperative (47.20±11.77) points, the difference was statistically significant (P<0.05), and VAS at the lateat postoperative follow-up was 1 (1) points, compared with the preoperative 8 (2) points, the difference was statistically significant (P<0.05). At the last follow-up, the pain symptoms were relieved or disappeared, and the joint function was satisfactory. The imaging data of the latest follow-up showed joint was well pseudoradiated, no abnormal ossification occurred, and the prosthesis was not loose.@*CONCLUSION@#THA is effective in the treatment of traumatic arthritis secondary to acetabular fracture and can effectively improve the quality of life of patients. Preoperative comprehensive evaluation and bone defect evaluation of patients, and intraoperative management of acetabulum, femur, internal fixation and bone defect are key factors for the success of surgery.


Sujets)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Sujet âgé , Arthroplastie prothétique de hanche/méthodes , Défaillance de prothèse , Études rétrospectives , Qualité de vie , Acétabulum/traumatismes , Prothèse de hanche , Fractures de la hanche/chirurgie , Fractures du rachis/chirurgie , Arthrite/chirurgie , Résultat thérapeutique , Études de suivi
3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 113-118, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009117

Résumé

OBJECTIVE@#To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.@*METHODS@#The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.@*RESULTS@#Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.@*CONCLUSION@#Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.


Sujets)
Humains , Phénomènes biomécaniques , Plaques orthopédiques , Ostéosynthèse interne , Ostéosynthese intramedullaire , Fractures du tibia/chirurgie ,
4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 28-34, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1009104

Résumé

OBJECTIVE@#To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.@*METHODS@#A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.@*RESULTS@#All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).@*CONCLUSION@#Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.


Sujets)
Humains , Ostéosynthèse interne/méthodes , Études rétrospectives , Imagerie tridimensionnelle , Vis orthopédiques , Chirurgie assistée par ordinateur , Tomodensitométrie , Fractures du rachis/chirurgie , Fractures osseuses/chirurgie , Os coxal/traumatismes , Complications postopératoires , Traumatismes du cou
5.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 17-25, abr./jun 2023. ilus
Article Dans Portugais | LILACS, BBO | ID: biblio-1537357

Résumé

Introdução: A osteotomia Le Fort I possibilita a correção de deformidades dentofaciais que envolvem o terço médio da face. Para sua fixação, convencionou-se o emprego de quatro mini-placas nos pilares zigomático-maxilar e nasomaxilar. Propôs-se então, a dispensa da fixação do segmento posterior, surgindo questionamentos relacionados à capacidade biomecânica do sistema. Objetivos: Comparar o estresse biomecânico gerado em três meios distintos de fixação da osteotomia Le Fort I frente ao movimento de avanço sagital linear maxilar de 7mm. Metodologia: Trata-se de uma pesquisa experimental laboratorial, utilizando-se da análise de elementos finitos como ferramenta analítica, a fim de constatar qual das técnicas sofrerá maior estresse biomecânico. Resultados: Constatou-se que o estresse biomecânico gerado é maior quando aplicado em 4 pontos do que quando aplicado em apenas 2 pontos. Conclusão: Os resultados obtidos fornecem informações aos cirurgiões sobre a real necessidade do uso de fixação adicional de acordo com o método de fixação planejado. No entanto, deve ser interpretado de forma cautelosa, considerando-se as limitações deste estudo. Sendo assim, uma análise incipiente, que tem como intuito o fornecimento de evidência científica de grande significância.


Introducción: La osteotomía Le Fort I permite la corrección de deformidades dentofaciales que involucran el tercio medio de la cara. Para su fijación se acordó utilizar cuatro miniplacas en los pilares cigomaticomaxilar y nasomaxilar. Entonces se propuso prescindir de la fijación del segmento posterior, planteando interrogantes relacionados con la capacidad biomecánica del sistema. Objetivos: Comparar el estrés biomecánico generado en tres medios diferentes de fijación de la osteotomía Le Fort I frente a un movimiento de avance sagital lineal maxilar de 7mm. Metodología: Se trata de una investigación experimental de laboratorio, utilizando como herramienta analítica el análisis de elementos finitos, con el fin de comprobar cuál de las técnicas sufrirá un mayor estrés biomecánico. Resultados: Se encontró que el estrés biomecánico generado es mayor cuando se aplica en 4 puntos que cuando se aplica solo en 2 puntos. Conclusión: Los resultados obtenidos brindan información a los cirujanos sobre la necesidad real de utilizar fijación adicional de acuerdo al método de fijación planificado. Sin embargo, debe interpretarse con cautela, considerando las limitaciones de este estudio. Por tanto, un análisis incipiente, que pretende aportar evidencias científicas de gran trascendencia.


Introduction: The Le Fort I osteotomy allows the correction of dentofacial deformities involving the middle third of the face. For its fixation, it was agreed to use four mini plates on the zygomaticomaxillary and nasomaxillary pillars. It was then proposed to dispense with the fixation of the posterior segment, raising questions related to the biomechanical capacity of the system. Objectives: To compare the biomechanical stress generated in three different means of fixation of the Le Fort I osteotomy against a 7mm maxillary linear sagittal advancement movement. Methodology: This is an experimental laboratory research, using finite element analysis as an analytical tool, in order to verify which of the techniques will suffer greater biomechanical stress. Results: It was found that the biomechanical stress generated is greater when applied to 4 points than when applied to only 2 points. Conclusion: The results obtained provide information to surgeons about the real need to use additional fixation according to the planned fixation method. However, it should be interpreted with caution, considering the limitations of this study. Therefore, an incipient analysis, which aims to provide scientific evidence of great significance.


Sujets)
Ostéotomie de Le Fort , Analyse des éléments finis , Chirurgie orthognathique , Ostéosynthèse interne
6.
Rev. bras. ortop ; 58(1): 42-47, Jan.-Feb. 2023. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1441348

Résumé

Abstract Objective To compare the clinical results between conservative (CS) and surgical treatment (CXS) of A3 and A4 fractures without neurological deficit. Methods Prospective observational study of patients with thoracolumbar fractures type A3 and A4. These patients were separated between the surgical and conservative groups, and evaluated sequentially through the numeric rating scale (NRS), Roland-Morris disability questionnaire (RMDQ), EuroQol-5D (EQ-5D) quality of life questionnaire, and Denis work scale (DWS) up to 2.5 years of follow-up. Results Both groups showed significant improvement, with no statistical difference in pain questionnaires (NRS: CXS 2.4 ± 2.6; CS 3.5 ± 2.6; p> 0.05), functionality (RMDQ: CS 7 ± 6.4; CXS 5.5 ± 5.2; p> 0.05), quality of life (EQ-5D), and return to work (DWS). Conclusion Both treatments are viable options with equivalent clinical results. There is a tendency toward better results in the surgical treatment of A4 fractures.


Resumo Objetivo Comparar os resultados clínicos entre os tratamentos conservador (CS) e cirúrgico (CXS) das fraturas A3 e A4 sem déficit neurológico. Métodos Estudo prospectivo observacional de paciente com fraturas toracolombares tipo A3 e A4. Esses pacientes foram separados entre os grupos cirúrgico e conservador e avaliados sequencialmente através da escala numérica de dor (NRS), do questionário de incapacidade de Roland-Morris (RMDQ), do EuroQol-5D (EQ-5D) e da escala de trabalho de Denis (DWS) até 2,5 anos de acompanhamento. Resultados Ambos os grupos apresentaram melhora significante, sem diferença estatística nos questionários de dor (NRS: CXS 2,4 ± 2,6; CS 3,5 ± 2,6; p> 0,05), funcionalidade (RMDQ: CS 7 ± 6,4; CXS 5,5 ± 5,2; p> 0,05), qualidade de vida (EQ-5D) e retorno ao trabalho (DWS). Conclusão Ambos os tratamentos são opções viáveis e com resultados clínicos equivalentes. Há uma tendência a melhores resultados no tratamento cirúrgico das fraturas A4.


Sujets)
Humains , Fractures du rachis/chirurgie , Résultat thérapeutique , Traitement conservateur , Ostéosynthèse interne
7.
China Journal of Orthopaedics and Traumatology ; (12): 247-250, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970856

Résumé

OBJECTIVE@#To investigate the clinical effect of double pulley combined with suture bridge in the treatment of comminuted fracture of the lower pole of the patella.@*METHODS@#From January 2018 to June 2020, 15 patients with comminuted fracture of the lower pole of the patella were treated with double pulley and suture bridge technology, including 9 males and 6 females, aged 28 to 68 years old with an average of (42.4±9.6) years old. All patients had obvious knee joint pain and limited movement after injury. All knee joints were examined by X-ray and CT, which confirmed that they were all comminuted fractures at the lower level of the patella. After operation, X-ray films of the knee joint were taken regularly to understand the fracture healing, the Insall Salvati index was measure, the range of motion of the joint was recorded, and the function of the knee joint was evaluateed by the Bostman scoring system.@*RESULTS@#All the 15 patients were followed up for 7 to 24 months with an average of (11.4±4.2) months, and there was no obvious anterior knee pain. At the last follow-up, the knee joint range of motion of the affected limb was 105° to 140° with an average of (128.5±12.8) °, and the Insall Salvati index was 0.79 to 1.12 with an average of (0.92±0.18). The X-ray film showed that the patella was bone healing, and no anchor fell off, broken, or displaced fracture block was found. Bostman patellar fracture function score was 27.85±2.06, 13 cases were excellent, 2 cases were good.@*CONCLUSION@#Double pulley technique combined with suture bridge technique is reliable for reduction and fixation of comminuted fracture of the lower pole of patella, and patients can start functional exercise early after operation.


Sujets)
Mâle , Femelle , Humains , Adulte , Adulte d'âge moyen , Sujet âgé , Fractures comminutives/chirurgie , Ostéosynthèse interne/méthodes , Patella/traumatismes , Fils métalliques , Fractures osseuses/chirurgie , Matériaux de suture , Résultat thérapeutique
8.
China Journal of Orthopaedics and Traumatology ; (12): 242-246, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970855

Résumé

OBJECTIVE@#To investigate the relationship between the shape of the lateral wall and the early failure of internal fixation in the fracture of the femoral trochanteric region(FFT).@*METHODS@#Total 295 patients with femoral trochanteric fracture underwent internal fixation from January 2015 to January 2020 were selected. The patients were divided into two groups according to whether there was early internal fixation failure after surgery, 19 patients in the failure group and 276 patients in the normal group. Gender, affected side, age, AO classification, body mass index(BMI), preoperative hemoglobin, X-ray measurement of lower lateral wall thickness, preoperative internal diseases, intraoperative blood loss, postoperative tip apex distance(TAD), postoperative neck shaft angle, operation time and other data were compared between two groups. The shape of the lateral wall was compared between two groups, and the correlation between the shape of the lateral wall and the early internal fixation failure of femoral trochanteric fracture was analyzed.@*RESULTS@#All patients were followed up for more than 1 year. There was no significant difference between two groups in terms of intraoperative blood loss, operation time, postoperative TAD, and postoperative neck shaft angle(P>0.05). At the latest follow-up, the visual anaglue scale (VAS) of the failure group was higher than that of the normal group(P<0.01), and the Harris score of the failure group was lower than that of normal group(P<0.05). The receiver operator characteristic (ROC) curve between shape of lateral wall and failure of early internal fixation of femoral trochanteric fracture was drawn. The critical value of the midpoint lateral wall thickness was 16.5 mm, and the area under the ROC curve was 0.845;The critical value of average sidewall thickness was 16.5 mm, and the area under ROC curve was 0.838;The critical value of the axial area of the sidewall was 7.5 mm, and the area under the ROC curve was 0.826.@*CONCLUSION@#The shape of the lateral femoral wall measured by CT could be used as a predictive factor for the early failure of internal fixation of femoral trochanteric fractures. For patients at risk, more reasonable surgical plans and postoperative preventive measures should be developed.


Sujets)
Humains , Résultat thérapeutique , Ostéosynthese intramedullaire , Clous orthopédiques , Études rétrospectives , Fractures de la hanche/chirurgie , Ostéosynthèse interne
9.
China Journal of Orthopaedics and Traumatology ; (12): 232-235, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970853

Résumé

OBJECTIVE@#To analyze and compare the clinical efficacy of internal fixation and total hip replacement in the treatment of displaced femoral neck fracture from 55 to 65 years.@*METHODS@#From September 2016 to August 2020, 86 patients with Garden type Ⅲ or Ⅳ femoral neck fracture were divided into two groups according to different surgical methods. Among them, 38 patients were treated with lag screws for internal fixation, there were 26 males and 12 females, aged 55 to 64 years old with an average of(60.2±3.1) years;the other 48 patients were treated with total hip replacement, including 28 males and 20 females, aged from 57 to 65 years old with an average of(61.3±3.8) years. The time from injury to operation ranged from 1 to 3 days. The reoperation rate, incidence of deep infection, Harris score of hip joint function, visual analogue scale(VAS) of pain and patients reported outcome scores(European five-dimensional Health Questionnaire, EQ-5D) were compared between two groups.@*RESULTS@#All patients were followed up for 24 to 54 months with an average of (35.8±10.3) months. There was significant difference in reoperation rate between two groups (P<0.05). There was no significant difference on the incidence of deep infection, hip Harris score and VAS between two groups(P>0.05) . The postoperative EQ-5D score of patients with internal fixation was lower than that of total hip replacement, and the difference was statistically significant(P<0.05).@*CONCLUSION@#Both the surgery of internal fixation and total hip replacement have similar effect in short-and medium term among the patients aged 55 to 65 years old. However, for the reoperation rate, the group of internal fixation was higher than that of total hip replacement. For the subjective functional score of patients, the group of internal fixation was lower than that of total hip replacement.


Sujets)
Mâle , Femelle , Humains , Adulte d'âge moyen , Sujet âgé , Arthroplastie prothétique de hanche/méthodes , Résultat thérapeutique , Fractures du col fémoral/chirurgie , Ostéosynthèse interne/méthodes , Réintervention
10.
China Journal of Orthopaedics and Traumatology ; (12): 226-231, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970852

Résumé

OBJECTIVE@#To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.@*METHODS@#From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.@*RESULTS@#Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).@*CONCLUSION@#Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Sujets)
Adulte d'âge moyen , Humains , Résultat thérapeutique , Perte sanguine peropératoire , Études rétrospectives , Ostéosynthèse interne/méthodes , Fractures du col fémoral/chirurgie , Vis orthopédiques
11.
China Journal of Orthopaedics and Traumatology ; (12): 221-225, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970851

Résumé

OBJECTIVE@#To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.@*METHODS@#The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.@*RESULTS@#The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).@*CONCLUSION@#Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.


Sujets)
Mâle , Femelle , Humains , Adulte d'âge moyen , Robotique , Études rétrospectives , Fractures du col fémoral/chirurgie , Vis orthopédiques , Ostéosynthèse interne/méthodes , Résultat thérapeutique
12.
China Journal of Orthopaedics and Traumatology ; (12): 209-215, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970849

Résumé

OBJECTIVE@#To investigate the application of 3D printing percutaneous surgical guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.@*METHODS@#The clinical data of 12 patients with femoral neck fracture from March 2019 to March 2022 were retrospectively analyzed. Patients were divided into observation group and control group according to different operation plans, with 6 cases in each group. The observation group received percutaneous operation guide plate assisted closed reduction and hollow screw internal fixation, while the control group received closed reduction and hollow compression screw internal fixation. The operation time, intraoperative blood loss, fluoroscopy times, and Kirschner needle puncture times were compared between two groups. The location of screws were recordedon postoperative X-ray films, follow-up time, time of complete fracture healing, Harris score of hip joint and the incidence of complications were recorded on postoperative X-ray films.@*RESULTS@#The operation time of observation group (32.17±6.18) min was shorter than that of control group (53.83±7.31) min (P<0.05). The amount of intraoperative bleeding in the observation group (18.33±2.94) ml was less than that in the control group (38.17±5.56) ml(P<0.05). The times of fluoroscopy in the observation group (7.50±1.05) were less than those in the control group (21.00±4.82) (P<0.05). The number of Kirschner needle punctures (8.00±0.63) in observation group was less than that in control group (32.67±3.08) (P<0.05). The follow-up time was(12.88±0.74) months in observation group and (12.83±0.72) months in control group, there was no significant difference between two groups (P>0.05). One year after operation, Harris score of hip joint in the observation group was(82.00±4.52) points, while that in the control group was(81.00±3.41) points, there was no significant difference between two groups(P>0.05). The time of complete fracture healing in the observation group was (7.50±1.05) months, while that in the control group was (7.67±1.21) months, there was no significant difference between two groups(P>0.05). The parallelism of the screws in the observation group was (0.50±0.11) ° and (0.76±0.15) °, which were lower than that in the control group (1.57±0.31) ° and (1.87±0.21) ° (P<0.05). The screw distribution area ratio (0.13±0.02) cm2 in the observation group was higher than that in the control group (0.08±0.01) cm2 (P<0.05). No complications such as necrosis of femoral head, nonunion of fracture, shortening of femoral neck and withdrawal of internal fixation occurred in both groups.@*CONCLUSION@#The application of 3D printing percutaneous surgical guide plate improves the accuracy and safety of closed reduction and cannulated screw internal fixation for femoral neck fracture. It has the advantages of minimally invasive, reducing radiation exposure, fast and accurate, shortening the operation time and reducing intraoperative bleeding.


Sujets)
Humains , Études rétrospectives , Résultat thérapeutique , Fractures du col fémoral/chirurgie , Ostéosynthèse interne , Vis orthopédiques , Impression tridimensionnelle
13.
China Journal of Orthopaedics and Traumatology ; (12): 156-160, 2023.
Article Dans Chinois | WPRIM | ID: wpr-970838

Résumé

OBJECTIVE@#To retrospectively analyze the clinical efficacy of olecranon osteotomy approach in the treatment of Dubberley type Ⅲ coronal fractures of the distal humerus and summarize the treatment experience.@*METHODS@#From January 2016 to June 2020, 17 patients (5 males and 12 females) with Dubberley type Ⅲ coronal fractures of the distal humerus were treated by olecranon osteotomy approach. The age ranged from 37 to78 years old with an average of (58.5±12.9) years old. According to Dubberley classification, there were 5 cases of type Ⅲ A and 12 cases of type Ⅲ B. The curative effect was evaluated using the Borberg-Morrey elbow function score. The flexion, extension and rotation range of motion of the elbow joint, complications and postoperative imaging evaluation were recorded.@*RESULTS@#All the 17 patients got bony union. The follow-up time ranged from 12 to 33 months with an average of (15.6±5.6) months. There was 1 case of ischemic necrosis of capitulum humeri, 2 cases of traumatic arthritis and 1 case of heterotopic ossification, 1 case of malunion of fracture. The range of motion was (114.80±19.50) °. The Broberg-Morrey score was 85.3±8.2, excellent in 5 cases, good in 9 cases, fair in 3 cases and poor in 0 case.@*CONCLUSION@#Through olecranon osteotomy approach, the articular surface of distal humerus could be fully exposed, and the operation is convenient. Anatomical reduction and rigid fixation of the articular surface of distal humerus are the key factors for the succesful outcome.


Sujets)
Mâle , Femelle , Humains , Adulte , Processus olécrânien/chirurgie , Articulation du coude/chirurgie , Fractures de l'humérus/chirurgie , Études rétrospectives , Ostéosynthèse interne/méthodes , Humérus/chirurgie , Résultat thérapeutique , Amplitude articulaire
14.
Journal of Peking University(Health Sciences) ; (6): 910-914, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1010148

Résumé

OBJECTIVE@#To investigate the clinical significance of different plastic surgeries in the treatment of poor healing wound after posterior spinal internal fixation.@*METHODS@#In this study, 16 patients with poor incision healing after posterior spinal internal fixation were retrospectively included, and dif-ferent plastic surgery treatment plans were determined according to the wound characteristics and defect condition. The measures included debridement, vacuum sealing drainage (VSD), and different tissue flaps according to the location and extent of the defect.@*RESULTS@#A total of 16 patients meeting the criteria were included, of whom 3 were treated with debridement combined with VSD and wound suture directly, 6 were treated with debridement combined with Z-flap for wound repair, 1 was treated with bilateral sacrospinous muscle flap for dural defect repair combined with Z-flap for skin wound repair, 1 was treated with lectus dorsi flap for wound repair, 3 were treated with the fourth lumbar artery perforator flap for wound repair. The wound was repaired with local rotating flap in 1 case and gluteus maximus musculocutaneous flap in 1 case. Among the 16 patients, 7 cases were positive for wound culture, including 3 cases of Staphylococcus aureus, 1 case of Pseudomonas aeruginosa, 1 case of Staphylococcus epidermidis, 1 case of Escherichia coli, 1 case of Klebsiella pneumoniae, and the other 9 cases were negative. After surgery, there were 7 patients with different degrees of poor wound healing, including 3 patients undergoing dressing change, 2 patients undergoing secondary debridement and suture, 1 patient undergoing free scalp skin graft, and 1 patient undergoing local effusion suction treatment. All the above 7 patients were discharged from hospital after improvement, and the remaining 9 patients had good first-stage wound hea-ling after surgery. None of the 16 patients underwent internal fixation.@*CONCLUSION@#Multiple factors could lead to poor wound healing after posterior spinal internal fixation. Early intervention, thorough debridement, removal of necrotic/infected tissue, and selection of suitable skin flap for effective wound fil-ling and covering were important means to ensure wound healing after spinal surgery and reduce removal of internal fixation.


Sujets)
Humains , Études rétrospectives , Cicatrisation de plaie , Débridement , , Lambeaux chirurgicaux/vascularisation , Transplantation de peau , Résultat thérapeutique
15.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6): 300-303, 2023.
Article Dans Chinois | WPRIM | ID: wpr-995944

Résumé

Objective:To observe the difference in the effect of simple titanium plate internal fixation and titanium plate internal fixation combined with titanium nail intermaxillary traction in the treatment of jaw fractures and their impact on the oral and maxillofacial function of patients.Methods:From August 2016 to May 2021, 94 patients with jaw fractures admitted to the Department of Stomatology, Linyi Central Hospital, Shandong (supplementing the gender, age range and average age of the patients), were divided into 47 cases in the control group, and the titanium plates were used alone, combined operation group 47 cases, titanium plate internal fixation combined with intermaxillary traction with titanium nails. The changes of oral and maxillofacial function and fracture healing were measured before operation and 3 months after operation, and the perioperative indicators and postoperative complications were recorded.Results:Three months after operation, the scores of maxillofacial function, mouth function and masticatory function in the combined operation group (0.52±0.09 points, 0.67±0.12 points, 0.58±0.08 points) were significantly lower than those in the control group (1.05±0.21 points, 1.14±0.22 points, 1.02±0.21 points) ( t=15.90, 12.86, 13.42, P<0.05). The effective rate of the combined operation group was 95.74% (45/47), which was significantly higher than that of the control group (80.85%, 38/47) (χ 2=5.05, P<0.05); there was no significant difference in operation time and hospitalization time between the groups ( P>0.05), the fracture healing time in the combined surgery group (65.02±7.06) d was significantly shorter than that in the control group (82.69±10.25) d ( t=9.73, P<0.05). The postoperative complication rate of combined treatment group was 6.38% (3/47), which was significantly lower than the control group 21.28% (10/47) (χ 2=4.37, P<0.05). Conclusions:In the treatment of jaw fractures, titanium plate internal fixation combined with titanium nail intermaxillary traction treatment can significantly improve the oral and maxillofacial function of patients, promote postoperative fracture healing, improve curative effect and reduce the incidence of complications compared with simple titanium plate internal fixation.

16.
Chinese Journal of Orthopaedic Trauma ; (12): 702-710, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992770

Résumé

Objective:To compare 3D-printing-assisted surgery and conventional surgery in the treatment of Schazker type Ⅵ tibial plateau fractures.Methods:A retrospective study was conducted to analyze the clinical data of 50 patients with type Ⅵ tibial plateau fracture who had been treated from January 2019 to December 2021 at the 5 Departments of Orthopedics in The First Affiliated Hospital of Nanchang University, The First People's Hospital of Jiujiang, Pingkuang General Hospital, Ganzhou People's Hospital, and Nanchang Hongdu Hospital of Traditional Chinese Medicine. The patients were divided into 2 groups according to their different treatment methods. In the 3D printing group of 25 cases treated by 3D-printing-assisted surgery, there were 14 males and 11 females, with an age of (42.5±9.1) years; in the conventional group of 25 cases treated by conventional surgery, there were 13 males and 12 females with an age of (42.2±9.3) years. The 2 groups were compared in terms of operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, fracture healing time, postoperative complications, the Rasmussen radiological scores and the American Hospital for Special Surgery (HSS) knee function scores at 6 and 12 months after operation.Results:There was no significant difference in the preoperative general data between the 2 groups, indicating comparability ( P>0.05). The operation time [(125.4±10.6) min], intraoperative blood loss [(206.2±16.3) mL], intraoperative fluoroscopy frequency [(9.2±2.7) times] and fracture healing time [(3.0±0.7) months] in the 3D printing group were all significantly less than those in the conventional group [(168.2±14.1) min, (303.2±20.4) mL, (15.5±3.5) times and (4.1±0.8) months] while the Rasmussen radiological scores (17.6±1.2 and 17.9±0.6) and HSS knee scores (90.8±6.4 and 91.5±5.6) at 6 and 12 months after operation in the 3D printing group were all significantly higher than those in the conventional group (16.2±2.6 and 16.7±2.2; 84.5±9.2 and 87.6±8.0) (all P<0.05). In the 3D printing group, there were 1 case of wound infection and 1 case of wound dehiscence after operation. In the conventional group, there were 2 cases of wound skin necrosis, 3 cases of wound dehiscence, 1 case of traumatic arthritis, 2 cases of wound infection, and 1 case of screw loosening. The incidence of complications in the 3D printing group (8.0%, 2/28) was significantly lower than that in the conventional group (36.0%, 9/25) ( P<0.05). Conclusion:In the treatment of Schatzker type VI tibial plateau fractures, compared with conventional surgery, 3D-printing-assisted surgery can lead to better curative outcomes, because it is conducive to lowering surgical difficulty, reducing postoperative complications, and promoting fracture union and functional recovery of the knee.

17.
Chinese Journal of Orthopaedic Trauma ; (12): 77-82, 2023.
Article Dans Chinois | WPRIM | ID: wpr-992684

Résumé

Objective:To evaluate the efficacy of arthroscopic minimally invasive reduction in the treatment of talus posterior process fractures.Methods:The clinical data were retrospectively studied of the 42 patients with talus posterior process fracture who had been admitted to Department of Orthopedics, The Fourth Hospital of Wuhan from January 2010 to June 2021. There were 25 males and 17 females, aged from 21 to 60 years (average, 40.5 years). They were assigned into 2 groups according to their different treatments. In the arthroscopic group of 15 cases, arthroscopic reduction and internal fixation (ARIF) were conducted via the posteromedial and posterolateral approaches; in the open reduction group of 27 cases, open reduction and internal fixation (ORIF) were conducted via the posteromedial para-Achilles approach. The 2 groups were compared in terms of operation time, blood loss, hospital stay, fracture clinical healing time, postoperative complications, and the American Society for Foot and Ankle Surgery (AOFAS) ankle-hindfoot score at one year postoperation.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P> 0.05). The arthroscopic group incurred significantly less blood loss [(32.0±11.5) mL], hospital stay [(5.3±1.8) d], and fracture clinical healing time [(4.6±1.0) months], and a significantly lower incidence of postoperative complications [20.0% (3/15)] than the open reduction group did [(80.0±15.2) mL, (8.4±2.4) d, (6.3±2.2) months, and 29.6% (8/27)], but significantly longer operation time [(74.0±8.9) min] than the open reduction group [(62.9±5.1) min] ( P<0.05). The AOFAS ankle-hindfoot scores at one year postoperation in both groups were higher than those before operation. The AOFAS ankle-hindfoot scores in the arthroscopic group [(83.0±13.0) points] were significantly higher than those in the open reduction group [(72.3±16.0) points] ( P<0.05). Conclusion:ARIF is a preferred minimally invasive treatment for talus posterior process fractures, because it leads to a smaller incision, less blood loss, shorter hospital stay, quicker clinical healing, a lower incidence of postoperative complications, and better functional improvement of the ankle and hindfoot than ORIF.

18.
Chinese Journal of Applied Clinical Pediatrics ; (24): 693-697, 2023.
Article Dans Chinois | WPRIM | ID: wpr-990099

Résumé

Objective:To investigate the clinical effect of arthroscopic reduction of tibial intercondylar ridge fractures in children using a 2.0 mm perforated Kirschner wire to establish bone tunnels and the Krackow-" 8" suture.Methods:From January 2018 to December 2020, 24 children (14 males and 10 females, aged 6-15 years) with tibial intercondylar ridge fractures admitted to Children′s Hospital of Nanjing Medical University were retrospectively recruited for analyses.All patients were treated with arthroscopic reduction, non-absorbable Krackow-" 8" suture for the base of the anterior cruciate ligament, and establishment of bone tunnels by 2.0 mm perforated Kirschner wire from the proximal tibial epiphysis for inserting a suture to fix the fractures.The affected limb was immobilized with a cast for 4 weeks, followed by active exercises postoperatively.Knee function was assessed using the Lysholm score and IKDC 2000 subjective score.Knee stability was evaluated using the Lachman test.X-rays were taken at 3 and 6 months postoperatively to evaluate fracture healing.Growth retardation of epiphyseal plate at 2 years of follow-up was assessed by bilateral knee X-rays.Results:All the 24 cases were successfully operated, with the operation time of (63.1±20.2) (40-115) min.All children were followed up for 24-36 months[(28.7±3.4) months]. All children achieved an anatomical reduction of the fracture postoperatively.No complications like fracture displacement, suture rupture, or infection were reported.All fractures healed completely at 3 months postoperatively.At the last follow-up, the Lysholm score and IKDC 2000 subjective score were (94.4±4.8) points and (93.8±5.6) points, respectively.The positive Lachman test was detected in 2 patients.No inhibition of proximal tibial epiphyseal growth was observed.Conclusions:Arthroscopic reduction with non-absorbable Krackow-" 8" suture and establishment of bone tunnels using a 2.0 mm perforated Kirschner wire for the treatment of tibial intercondylar ridge fractures in children has the advantages of simple surgical procedures, minimal invasiveness, which is an effective treatment method.

19.
Acta Anatomica Sinica ; (6): 586-592, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1015187

Résumé

[Abstract] Objective To investigate the appropriate X-ray angle which image can represent total proximal of femur according to the anatomic shape of the femoral neck section. Methods The anatomic parameter of the femoral neck section was observed and measured. Found the femoral neck was contained with three main surfaces of anterior surface, posterosuperior surface and posteroinferior surface. A model of surface fluoroscopy has been made by covering aluminum foil papers on the three surfaces of femoral neck. Taking the midpoint of the femoral neck as the fluoroscopy center, the C-arm was rotated at an interval of 10° between 0° and 170°, and the three aluminum foil paper models were taken for X-ray projection respectively. The X-ray angle with the smallest image of aluminum foil paper was taken as the appropriate X-ray angle of the surface. A penetrating model of the femoral neck internal fixation was made of three Kirschner wires penetrating through the anterior, posterosuperior and posteroinferior surfaces of femoral neck. The images of the penetrating Kirschner wires were observed through the traditional anteroposterior, lateral view and the three appropriate X-ray angle views obtained from the above test. Results The length of the three main surfaces accounts for 80. 95% of the circumference of the femoral neck. The anterior surface coronal angle was 18°, the posterosuperior surface coronal angle was 65°, and the posteroinferior surface coronal angle was 165°. The Appropriate X-ray angle of the three surfaces were 20°, 70° and 170° respectively. In the images of the three appropriate X-ray angles, the penetrating Kirschner wires of anterior surface, posterosuperior surface and posteroinferior surface of the femoral neck could be clearly observed respectively, while the penetrating Kirschner wire could not be completely found in the traditional anteroposterior and lateral images. Conclusion Traditional anteroposterior and lateral fluoroscopy can not accurately display the three-dimensional structure of femoral neck. By increasing the appropriate X-ray angle of 20°, 70° and 170°, the reduction quality and bony violation from internal fixation implants on the anterior surface, posterosuperior surface and posteroinferior surface of the femoral neck could be observed respectively.

20.
Chinese Journal of Medical Instrumentation ; (6): 312-316, 2023.
Article Dans Chinois | WPRIM | ID: wpr-982235

Résumé

This study briefly introduces the revised content of Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021) compared to the original guidance, mainly including the principles of dividing registration unit, main performance indicators of standard specification, physical and mechanical performance research, and clinical evaluation. At the same time, in order to provide some references for the registration of metallic bone plate internal fixation system, this study analyzes the main concerns in the review process of these products based on the accumulation of experience combining with the current review requirements.


Sujets)
Plaques orthopédiques , Ostéosynthèse interne , Phénomènes biomécaniques
SÉLECTION CITATIONS
Détails de la recherche