Journal of Jilin University(Medicine Edition) ; (6): 1-9, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1017313

Résumé

Objective:To discuss the regulatory effect of physiological tensile stress on the differentiation of chondrocytes,and to clarify the associated signaling pathway mechanism.Methods:The ATDC5 chondrocytes were cultured in vitro and subjected to physiological tensile stress by four-point bending cell mechanical loading device.Initially,the cells were divided into control group and tensile stress group(2 000 μstrain/2 h group),and further divided into different stress magnitudes(1 000,2 000,and 3 000 μstrain)for 2 h,and 2 000 μstrain for different duration time(1,2,and 4 h)groups;the cells without tensile stress were used as control group.Real-time fluorescence quantitative PCR(RT-qPCR)method was used to detect the expression levels of type Ⅱ collagen(Col-Ⅱ),type Ⅹ collagen(Col-Ⅹ),aggregated proteoglycom(Aggrecan),sex-determining region Y-box protein 9(SOX9),vascular endothelial growth factor(VEGF),proliferating cell nuclear antigen(PCNA),Nel-like molecule tyep 1(Nell-1),Runt-related transcription factor 2(Runx2),Indian hedgehog(Ihh),patched homolog 1(Ptch-1),GLI family zinc finger protein 1(Gli-1),and hedgehog interacting protein 1(Hhip-1)mRNA in the cells in various groups;Western blotting method was used to detect the expression levels of Nell-1,Runx2,and Ihh proteins in the cells in various groups.The ATDC5 cells were divided into control group,cyclopamine group,tensile stress group,and cyclopamine + tensile stress group.RT-qPCR method was used to detect the expression levels of Nell-1,Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in various groups;Western blotting method was used to detect the expression levels of Nell-1 and Ihh proteins in the cells in various groups.Results:Compared with control group,the expression levels of Col-Ⅱ,Col-Ⅹ,Aggrecan,SOX9,VEGF,and PCNA mRNA in the cells in 2 000 μstrain/2 h group were significantly increased(P<0.01);after treated with 2 000 μstrain tensile stress for different duration time(1,2,and 4 h)or different tensile stresses(1 000,2 000,and 3 000 μstrain)for 2 h,compared with control group,the expression levels of Runx2 mRNA in the cells in other groups were increased with the prolongation of time or the increasing of tensile stress(P<0.01),and the expression levels of Nell-1,Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA were gradually increased(P<0.01),the expression levels reached the peaking at 2 000 μstrain/2 h,and then decreased but remained significantly higher than that in control group(P<0.01).The Western blotting results showed that the expression levels of Nell-1,Runx2,and Ihh proteins in the cells were consistent with the change trend of mRNA expression levels.After pre-treated with cyclopamine,compared with control group,the expression levels of Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in cyclopamine group were significantly decreased(P<0.01),and the expression levels of Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in tensile stress and cyclopamine+tensile stress groups were significantly increased(P<0.01);compared with cyclopamine group,the expression levels of Nell-1,Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in cyclopamine+tensile stress group were significantly increased(P<0.01);compared with tensile stress group,the expression levels of Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in cyclopamine + tensile stress group were significantly decreased(P<0.01).Compared with control group,the expression level of Ihh protein in the cells in cyclopamine group was significantly decreased(P<0.01),but there was no significant difference in expression level of Nell-1 protein in the cells between control group and cyclopamine group(P>0.05),while the expression levels of Nell-1 and Ihh proteins in the cells in tensile stress group and cyclopamine + tensile stress group were significantly increased(P<0.01);compared with cyclopamine group,the expression levels of Nell-1 and Ihh proteins in the cells in tensile stress group and cyclopamine + tensile stress group were significantly increased(P<0.01);compared with tensile stress group,in the expression levels of Nell-1 and Ihh proteins in the cells in cyclopamine + tensile stress group had no significant differences(P>0.05).Conclusion:After stimulated with physiological tensile stress,Nell-1 can activate the Ihh signaling pathway upstream,and regulate the differentiation of the ATDC5 chondrocytes.

2.
Chinese Journal of Tissue Engineering Research ; (53): 3451-3456, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1021717

Résumé

BACKGROUND:The anterior cruciate ligament has unique nonlinear mechanical properties under a complex physiological loading environment.Elastin is an important contributor to the mechanical properties of the anterior cruciate ligament,but its mechanical response to the anterior cruciate ligament under axial tension is not clear. OBJECTIVE:To quantitatively analyze the effect of elastin on the tensile mechanical response of the anterior cruciate ligament. METHODS:Elastase solution and control buffer were prepared.The porcine anterior cruciate ligament samples were prepared into small-size samples and randomly soaked in 0,0.1,1.0,2.0,5.0,and 10.0 U/mL elastase solution for 6 hours,and other small samples of the same size were soaked in 2 U/mL elastase solution for 0,1,3,6,9,and 12 hours.To determine suitable soaking conditions for elastin-targeted enzymes and verify the digestive effect,histological staining was used to compare the effects of enzyme treatment on tissue structure and composition.The ligament samples were randomly divided into elastase-treated group and PBS group,and immersed in 2 U/mL elastase solution and PBS buffer for 6 hours,respectively.A mechanical tensile test was performed before and after immersion. RESULTS AND CONCLUSION:(1)The biochemical results showed that being treated in 2 U/mL elastase solution for 6 hours could reduce the elastin content by 31.1%,and had no significant effect on other mechanical-related components in the tissue.(2)The histological results showed that elastase was able to penetrate the tissue,and the loose degree of tissue increased after treatment.(3)In the mechanical results before and after treatment,the mechanical properties of the PBS group decreased significantly,only the low-tension elastic modulus increased significantly and the initial length increased significantly in the elastase-treated group.(4)The intergroup comparison results showed that there was no significant difference between the two groups in pre-treatment,but the low-tension elastic modulus,initial slopes,saturated slopes,and initial length of the elastase-treated group after treatment were significantly higher than those in the PBS group.(5)These results suggest that elastin degradation significantly affects the biomechanical properties of the anterior cruciate ligament and further complements our understanding of the structure-function relationship of the anterior cruciate ligament.

3.
Chinese Journal of Tissue Engineering Research ; (53): 4788-4794, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1021920

Résumé

BACKGROUND:Cervical rotatory manipulation is widely used in the treatment of neck-related diseases with a clear curative effect,but it also has some risks in clinical practice.The previous study of our group found that cervical rotatory manipulation can reduce the tensile mechanical properties of the atherosclerotic carotid artery,but it is not clear about the effects of different cervical rotatory manipulations(positioning/non-positioning)and different degrees(mild/moderate/severe)of atherosclerosis on the tensile mechanical properties of the carotid artery. OBJECTIVE:To explore the effects of different cervical rotatory manipulations and different degrees of atherosclerosis on the tensile mechanical properties of the internal carotid artery. METHODS:The 120 male New Zealand rabbits were randomly divided into eight experimental groups with different degrees of atherosclerosis and different cervical rotatory manipulations:severe atherosclerosis + positioning/non-positioning cervical rotatory manipulation,moderate atherosclerosis + positioning/non-positioning cervical rotatory manipulation,mild atherosclerosis + positioning/non-positioning cervical rotatory manipulation,and normal rabbit + positioning/non-positioning cervical rotatory manipulation,as well as three model control groups:mild/moderate/severe atherosclerosis + non-cervical rotatory manipulation,and the blank control group.Two-factor analysis of variance was used to explore the main effects and interactive effects of different cervical rotatory manipulations and different degrees of atherosclerosis on the tensile mechanical properties of the internal carotid artery.One-way analysis of variance was applied to explore the influence of different cervical rotatory manipulations on the tensile mechanical properties of the internal carotid artery under the same degree of atherosclerosis. RESULTS AND CONCLUSION:(1)Both different cervical rotatory manipulations and different degrees of atherosclerosis were the main effect factors affecting the tensile mechanical properties of the internal carotid artery.(2)For both mild and severe atherosclerosis,both positioning and non-positioning cervical rotatory manipulations reduced the maximum stress of the internal carotid artery(P<0.05)and also increased the physiological elastic modulus of the internal carotid artery(P<0.05).(3)For moderate atherosclerosis,positioning and non-positioning cervical rotatory manipulations also increased the physiological elastic modulus of the internal carotid artery(P<0.05).Non-positioning cervical rotatory manipulation reduced the maximum strain of the internal carotid artery(P<0.05),and its maximum strain was also less than the internal carotid artery of the positioning cervical rotatory manipulations(P<0.05).(4)For the normal internal carotid artery,in addition to the maximum strain,both positioning and non-positioning cervical rotatory manipulations had no statistically significant effects on other tensile mechanical indicators of the internal carotid artery(P>0.05).(5)The results suggest that both positioning and non-positioning cervical rotatory manipulations may increase the stiffness of the atherosclerotic internal carotid artery,reducing its elasticity and brittleness.Therefore,both positioning and non-positioning cervical rotatory manipulations may increase the risk of cardiovascular events in mild/moderate/severe atherosclerotic internal carotid artery,and the more severe the atherosclerosis is,the greater the risk of positioning/non-positioning cervical rotatory manipulation treatment,but the risk of positioning cervical rotatory manipulation is not lower than that of non-positioning cervical rotatory manipulation.

4.
Acta Universitatis Medicinalis Anhui ; (6): 590-595, 2024.
Article Dans Chinois | WPRIM | ID: wpr-1036296

Résumé

Objective @#To develop a high modulus and high strength biodegradable silk fibroin GBR membrane to address the issue of maintaining the space for bone regeneration in the repair of osseous defects . @*Methods @#After purifying silk fibroin protein , membrane materials were prepared using evaporation-hot pressing method . The physi- cal and chemical properties and biological performance of the membranes were evaluated using stretching tests , in vitro simulations , and cell co-culturing methods . @*Results @#A silk fibroin GBR membrane was successfully fabrica- ted , resulting in a simulated degradation rate of 35 . 3% after 12 h in vitro . The wet-state elastic modulus reached 45 MPa , while the tensile strength reached 8. 39 MPa. Furthermore , the cell survival rate was nearly 100% after 7 days . @*Conclusion @#The biodegradable GBR membrane produced in this study possesses high modulus and strength , as well as excellent biocompatibility , offering a promise as a foundation for addressing the bone defect re- pair and bone space maintenance .

5.
Rev. bras. ortop ; 58(1): 173-178, Jan.-Feb. 2023. graf
Article Dans Anglais | LILACS | ID: biblio-1441355

Résumé

Abstract The failure of ligament reconstruction has different risk factors, among which we can highlight the period before its incorporation, which is a mechanically vulnerable period. Loss of resistance over time is a characteristic of living tissues. Dissection with bone insertions of the cruciate ligaments of animal models is not described; however, it is essential for monoaxial assays to extract information from tests such as relaxation. The present work describes the dissection used for the generation of a test body for the performance of nondestructive tests to evaluate the mechanical behavior. We performed dissection of four porcino knee ligaments, proposing a dissection technique for the cruciate ligaments with bone inserts for comparison with collateral ligaments. The ligaments were submitted to relaxation tests and had strain gauges placed during the tests. The results showed viscoelastic behavior, validated by strain gauges and with a loss over time; with some ligaments presenting with losses of up to 20%, a factor to be considered in future studies. The present work dissected the four main ligaments of the knee demonstrating the posterior approach that allows maintaining their bone insertions and described the fixation for the monotonic uniaxial trials, besides being able to extract the viscoelastic behavior of the four ligaments of the knee, within the physiological limits of the knee.


Resumo A falha da reconstrução ligamentar tem diferentes fatores de risco, dentre os quais podemos destacar o período antes da sua incorporação, o qual configura um período mecânico vulnerável. A perda de resistência ao longo do tempo é uma característica dos tecidos vivos. A dissecção com as inserções ósseas dos ligamentos cruzados de modelos animais não é descrita; todavia, para os ensaios monoaxiais, é fundamental extrair as informações de ensaios como os de relaxação. O presente trabalho realiza a descrição da dissecção utilizada para a geração de corpo de prova para a realização de ensaios não destrutivos para avaliar o comportamento mecânico. Realizamos dissecção de quatro ligamentos de joelho porcino, propondo uma técnica de dissecção para os ligamentos cruzados com as inserções ósseas para comparação com os colaterais. Os ligamentos foram submetidos a testes de relaxação e foram colocadas strain gauges durante os testes. Os resultados mostraram comportamento viscoelástico, validado pelas strain gauges e com uma perda ao longo do tempo, sendo que, em alguns ligamentos, as perdas chegaram a até 20%, fator este a ser considerado em trabalhos futuros. O presente trabalho dissecou os quatro principais ligamentos do joelho, demonstrando a abordagem posterior que permite manter as suas inserções ósseas e descrevendo a fixação para os ensaios uniaxiais monotônicos, além de ter conseguido extrair o comportamento viscoelástico dos quatro ligamentos do joelho dentro dos limites fisiológicos do joelho.


Sujets)
Animaux , Résistance à la traction , Phénomènes biomécaniques , Dissection , Articulation du genou
6.
Rev. estomatol. Hered ; 33(1): 18-25, ene. 2023. tab
Article Dans Anglais | LILACS, LIPECS | ID: biblio-1441862

Résumé

Objective: To evaluate the microtensile bond strength in different dentine conditions (etched-E, non-etched-N, dry-D and wet-W) of a multimode adhesive (Scotchbond Universal-SU, 3M/ESPE) and a total etching adhesive (Ambar-AB, FGM) using a sonic device (Smart Sonic Device-SD, FGM). Material and methods: In this in vitro study, ninety six sound extracted human molars were divided into 12 groups (n=8) according to different dentine conditions and adhesive systems. Enamel was removed and the middle dentine surfaces were polished. Each adhesive system was applied according to the different dentine conditions, and composite resin blocks were incrementally built up and stored for 24 hours. Specimens were sectioned into sticks and bond strength data were analyzed with the Kruskal-Wallis test and Mann-Whitney U tests. Results: No effects of sonic application and were observed. In general, AB showed lower results compared to the SU. E and N conditions did not statistically affect the bond strength of SU groups. Dry dentine presented statistically superior bond strength values when compared to wet dentine for SU/E/SD group. Conclusion: Adhesion of dry dentine with multimode adhesive system may be superior to wet dentine with sonic application. The modes of application had no influence in bond strength of studied adhesives.


Objetivo: Evaluar la resistencia de la unión microtensil en diferentes condiciones de dentina (grabado-E, sin grabado-N, seco-D y húmedo-W) de un adhesivo multimodo (Scotchbond Universal-SU, 3M/ESPE) y un adhesivo de grabado total (Ambar-AB, FGM) utilizando un dispositivo sónico (Smart Sonic Device-SD, FGM). Material y Métodos: En este estudio in vitro, noventa y seis molares humanos extraídos sanos se dividieron en 12 grupos (n=8) de acuerdo con diferentes condiciones de dentina y sistemas adhesivos. Se eliminó el esmalte y se pulieron las superficies centrales de la dentina. Cada sistema adhesivo se aplicó de acuerdo con las diferentes condiciones de dentina, y los bloques de resina compuesta se acumularon de forma incremental y se almacenaron durante 24h. Las muestras se seccionaron en barras y los datos de resistencia de la unión se analizaron con la prueba de Kruskal-Wallis y la prueba de U de Mann-Whitney. Resultado: No se observaron efectos de la aplicación sónica. En general, AB mostró resultados más bajos en comparación con el SU. Las condiciones E y N no afectaron estadísticamente la fuerza de unión de los grupos SU. La dentina seca presentó valores de fuerza de adhesión estadísticamente superiores en comparación con la dentina húmeda para el grupo SU/E/SD. Conclusión: La adhesión de la dentina seca con un sistema adhesivo multimodo puede ser superior a la dentina húmeda con aplicación sónica. Los modos de aplicación no tuvieron influencia en la resistencia de la unión de los adhesivos estudiados.


Sujets)
Humains , Résistance à la traction , Agents de collage dentinaire , Dentine , Science des ultrasons , Techniques in vitro
7.
West China Journal of Stomatology ; (6): 260-268, 2023.
Article Dans Anglais | WPRIM | ID: wpr-981122

Résumé

OBJECTIVES@#This work aimed to investigate the molecular mechanism of cyclic tensile stress (CTS) stimulating autophagy in human periodontal ligament cells (hPDLCs).@*METHODS@#hPDLCs were isolated and cultured from normal periodontal tissues. hPDLCs were loaded with tensile stress by force four-point bending extender to simulate the autophagy of hPDLCs induced by orthodontic force du-ring orthodontic tooth movement. XMU-MP-1 was used to inhibit the Hippo signaling pathway to explore the role of the Hippo-YAP signaling pathway in activating hPDLC autophagy by tensile stress. The expression levels of autophagy-related genes (Beclin-1, LC3, and p62) in hPDLCs were detected by real-time quantitative polymerase chain reaction. Western blot was used to detect the expression levels of autophagy-related proteins (Beclin-1, LC3-Ⅱ/LC3-Ⅰ, and p62) and Hippo-YAP pathway proteins (active-YAP and p-YAP) in hPDLCs. Immunofluorescence was used to locate autophagy-related proteins (LC3-Ⅱand p62) and Hippo-YAP pathway proteins (active-YAP) of hPDLCs.@*RESULTS@#CTS-activated autophagy in hPDLCs and expression of autophagy-related proteins initially increased and then decreased; it began to increase at 30 min, peaked at 3 h, and decreased (P<0.05). CTS increased the expression of active-YAP protein and decreased the expression of p-YAP protein (P<0.05). When XMU-MP-1 inhibited the Hippo-YAP signaling pathway (P<0.05), active-YAP protein was promoted to enter the nucleus and autophagy expression was enhanced (P<0.05).@*CONCLUSIONS@#The Hippo-YAP signaling pathway is involved in the regulation of autophagy activation in hPDLCs under CTS.


Sujets)
Humains , Voie de signalisation Hippo , Desmodonte/métabolisme , Bécline-1/métabolisme , Cellules cultivées , Autophagie
8.
Journal of Medical Biomechanics ; (6): E164-E169, 2023.
Article Dans Chinois | WPRIM | ID: wpr-987930

Résumé

Objective To design and verify the reliability of a shoelace tensile test system. Methods Incremental loads of 0-196 N were applied to three tension sensors, each load was repeated nine times, with the load removed and interval of 30 s during the repeated tests. Then output voltage of the sensors under each load was collected. Linear regression analysis was used to explore linear relationship between the collected voltage signal and the incremental load. Accuracy, precision and consistency intervals were used to verify consistency of the measured values with the true load. Bland-Altman analysis and intra-group correlation coefficient (ICC) analysis were used to verify the repeatability and reliability of the tensile sensor. Results There was a significant linear correlation between output voltage signal of the sensors and the load (P< 0. 000 1, R2= 0. 999 9), and ICC of three sensors was above 0. 999 (P<0. 000 1). The mean values of the coefficients of variation of the measured values for three tensile sensors under different loads were 0. 003 8, 0. 002 2 and 0. 003 5, respectively. Conclusions The shoelace tensile test system has high reliability and can be used for real-time acquisition of shoelace tension.

9.
International Journal of Biomedical Engineering ; (6): 300-305, 2023.
Article Dans Chinois | WPRIM | ID: wpr-989354

Résumé

Objective:The microstructure, tensile strength, and bursting strength of different brands of hernia meshes were compared and analyzed through experiments to evaluate the performance of different meshes.Methods:The balance and microscope were used to test the weight and microstructure of 15 common meshes and the tensile testing machine and burst testing machine were used to test the tensile and bursting properties of the mesh, and the mechanical properties of the mesh were analyzed.Results:The woven structures of the mesh are diamond, polygon and circle. The average weight of inguinal meshes is 0.08 mg/mm 2, and the average weight of abdominal wall hernia meshes is 0.18 mg/mm 2. The wire diameters of G3 - G6 meshes are larger, while the mesh opening ratio of G12 is lower. In the tensile performance test, it is known that G15 has the highest tensile strength, G12 and G14 have lower tensile strengths in lightweight meshes, and G1, G2, and G7 have lower tensile strengths in lightweight meshes. In the burst performance test, it is known that G3, G9, and G15 have the highest burst strength, while G12, G13, and G14 have the lowest burst strength in lightweight meshes. G1, G2, and G4 have the lowest burst strength in lightweight meshes. Conclusions:The mesh with a polygonal mesh and a large mesh opening ratio has better mechanical properties. The results of this study provide experimental evidence for optimizing hernia meshes, which is expected to provide better support for related research and applications.

10.
STOMATOLOGY ; (12): 52-56, 2023.
Article Dans Chinois | WPRIM | ID: wpr-965141

Résumé

Objective@# To explore the effect of ultrasound on dentin smear layer's surface and bonding strength of the universal resin adhesive under self-etching mode. @*Methods@# Forty mandibular third molars without caries were randomly divided into two groups; one was polished with silicon carbide sandpaper; the other was polished with silicon carbide sandpaper followed by ultrasonic treatment. Scanning electron microscope (SEM) was used to observe surface of the dentin. Treated teeth were bonded with two universal resin adhesives, Clearfil Universal Bond (pH=2.3) and All-Bond Universal (pH=3.1), and the penetration of the bonding interface was observed with a confocal laser scanning microscope (CLSM) after Rhodamine B staining. Finally, the micro tensile bond strength test was conducted to test the adhesion. @*Results@# The SEM showed that after polishing with silicon carbide sandpaper, the smear layer of the dentin surface was scratched, and dentin tubules were almost completely blocked, with no obvious dentin tubules exposed. After ultrasonic treatment, the scratches were reduced, and a large number of dentin tubules were exposed. CLSM showed that both adhesives could penetrate the dentin along the dentin tubules more deeply after ultrasound treatment. Micro tensile bond strength tests showed that ultrasonic treatment could enhance the bonding strength of two universal resin adhesives. However, there was no statistical difference in bonding strength between these two universal resin adhesives under the same treatment. .@*Conclusion@# Ultrasound can partially remove the smear layer on dentin's surface, expose dentin tubules, and increase universal resin adhesives' penetration depth and bonding strength under self-etching mode

11.
Braz. j. oral sci ; 22: e239389, Jan.-Dec. 2023. ilus
Article Dans Anglais | LILACS, BBO | ID: biblio-1509457

Résumé

Aim: The purpose of this study was to investigate the biofilm effect on the hybrid ceramic-resin cement bond strength (BS) by comparing two methods. Methods: Teeth were distributed into groups (n=5), according to the resin cement (Maxcem Elite-(MC) or NX3 Nexus-(NX)) and degradation method (24h or 7 days in distilled water; 7 or 30 days incubated with biofilm and 30 days in sterile media). Treated surfaces of Vita Enamic blocks (5x6x7mm) were luted to treated or no treated dentin surfaces and light-cured. After 24h, beams were obtained (1x1x10mm) and stored accordingly. The flexural bond strength (FBS) was assessed by four-point bending test. Additional beams were obtained from new teeth (n=5), stored for 24h or 7 days in distilled water, and submitted to a microtensile bond strength (µTBS) assay. Failure modes were determined by scanning electron microscopy (100X). The flexure strength of the cements (n=10) was assessed by a four-point bending test. Data were analyzed by 1 and 2-ways ANOVA, and Tukey's test (α=0.05). Results: There was no significant difference between the degradation methods for the FBS groups. For the µTBS, the significant difference was as follows: NX 7days > NX 24h > MC 7days = MC 24h. Failure mode was mainly adhesive and mixed, but with an increase of cohesive within cement and pre-failures for the MC groups assessed by µTBS. NX had better performance than MC, regardless of the method. Conclusions: The biofilm had no effect on the materials BS and FBS test was a useful method to evaluate BS of materials with poor performance


Sujets)
Résistance à la traction , Microscopie électronique à balayage , Collage dentaire , Biofilms , Céments résine
12.
Braz. j. oral sci ; 21: e226036, jan.-dez. 2022. ilus
Article Dans Anglais | LILACS, BBO | ID: biblio-1393321

Résumé

Dental implants could give back function, esthetics and quality of life to patients. The correct choice of the implant, especially in borderline cases, is essential for a satisfactory result. Aim: Thus, the objective of this study was to evaluate the mechanical behavior of Morse taper implants with two different prosthetic interfaces. Methods: Twenty self-locking Morse taper implants, 2.9 mm in diameter (FAC), and 20 Morse taper implants, 3.5 mm in diameter (CM) were divided into two groups (n=10), and submitted to strength to failure test, optical microscopic evaluation of fracture, metallographic analysis of the alloy, finite element analysis (FEA) and strain gauge test. A Student's t test (α = 0.05) was made for a statistical analysis. Results: For the strength to failure test, a statistically difference was observed (p <0.001) between FAC (225.0 ± 19.8 N) and CM (397.3 ± 12.5 N). The optical microscopic evaluation demonstrated a fracture pattern that corroborated with FEA ́s results. The metallographic analysis determined that the implants of the FAC group have titanium-aluminum-vanadium alloy in their composition. In the strain gauge test, there was no statistical difference (p = 0.833) between CM (1064.8 ± 575.04 µS) and FAC (1002.2 ± 657.6 µS) groups. Conclusion: Based on the results obtained in this study, ultra-narrow implants (FAC) should ideally be restricted to areas with low masticatory effort


Sujets)
Résistance à la traction , Pose d'implant dentaire , Résistance à la flexion
13.
Braz. j. oral sci ; 21: e225454, jan.-dez. 2022. ilus
Article Dans Anglais | LILACS, BBO | ID: biblio-1366512

Résumé

Aim: Evaluating the resin-dentin bond strength of Class II conventional and bulk-fill composite restorations, using different cavity sizes before and after aging. Methods: Seventy-five human molars were distributed into groups according to the buccolingual width of the cavities, conservative (n=25) and extended (n=50). They were divided according to the restorative material: conventional (Z100/control group) or bulk-fill resin composites (Filtek Bulk Fill/FBF; Tetric N Ceram Bulk Fill/TNCBF; Filtek Bulk Fill Flow/FBFF; Surefill SDR flow/SDR). The restored teeth were sectioned on sticks (n=50 per restorative materials + width cavities group), half were stored in Water/Ethanol 75% for 30 days and the other half were submitted to the immediate microtensile bond strength (µTBS) test. Data were analyzed applying the Three-Way Analysis of Variance (ANOVA), Bonferroni test, test t, and Weibull analyses (p<0.05). Results: SDR and FBF presented lower µTBSvalues for extended preparation when compared to the conservative preparation, before aging. After aging, only for the FBFF, a decrease in the µTBSvalues was observed. Comparing the µTBSvalues, before and after aging, the SDR demonstrated lower µTBSvalues after aging when the conservative cavity was used. A decrease in the µTBSvalues was observed for the Z100, the FBF and, the FBFF, after aging, when the extended cavity was used. Conclusion: The effect of cavity preparation and aging on the resin-dentin of Class II is material dependent. Most of the bulk-fill resin composites evaluated presented a similar performance to the conventional resin composites for all the conditions of this study


Sujets)
Humains , Résistance à la traction , Vieillissement , Résines composites/analyse , Préparation de cavité dentaire
14.
Article | IMSEAR | ID: sea-222408

Résumé

Objective: To evaluate and compare the effect of variation in storage temperatures and duration on a tensile load at failure of elastomeric modules. Methods: In total, 140 modules were used in the study, 20 of which were tested on day 0 as received from a company using a Universal testing machine for baseline estimation of tensile load at failure. The rest 120 modules were divided into 6 groups. Groups I, II, and III modules were stored at low (T1 = 1–5°C), moderate (T2 = 20–25°C) and high (T3 = 35–40°C) temperatures, respectively, for 6 months. Groups IV, V and VI modules were stored at temperatures T1, T2 and T3 for 1 year, respectively, and were tested for tensile load at failure. Results: The tensile load at failure for the control group was 21.588 ± 1.082 N and for 6?month interval at temperatures T1, T2 and T3 was 18.818 N ± 1.121 N, 17.841 N ± 1.334 N and 17.149 N ± 1.074 N, respectively, and for 1 year, it was 17.205 N ± 1.043 N, 16.836 N ± 0.487 N and 14.788 N ± 0.781 N, respectively. The tensile load at failure decreased significantly from 6 months to 1 year among each temperature group. Conclusions: Maximum force degradation was seen in modules at high temperature followed by medium temperature and low temperature at both 6 months and 1 year intervals, and tensile load at failure decreased significantly from 6 months to 1 year storage duration. These results conclude that the temperature and duration at which the samples were exposed during storage produce a significant change in the forces exerted by the modules.

15.
Article Dans Espagnol | LILACS-Express | LILACS | ID: biblio-1535286

Résumé

Introducción: la cerámica de disilicato de litio es una excelente opción en rehabilitación, confeccionado con la técnica de inyección o maquinadas. El objetivo de este estudio fue evaluar la influencia de dos sistemas adhesivos sobre los valores de resistencia de unión en cerámicas de disilicato de litio inyectado y maquinado. Métodos: se utilizó discos de disilicato de litio, IPS e. Max CAD (Ivoclar Vivadent, Liechtenstein, Swiss), de 10mm de diámetro y 1mm de espesor embebidos en tubos de PVC. Se distribuyó en 4 grupos de trabajo, 2 en cerámica de litio inyectadas y 2 en maquinada, se aplicaron los adhesivos Palfique Bond y Tetric N-bond Universal según la distribución de grupos, luego se fotopolimerizó durante 10 segundos con lámpara luz led, se colocaron los tubos Tygon® para el relleno con resina fluida; una vez retirado los tubos Tygon®, se llevaron las muestras a una máquina de ensayo universal donde se realizó la prueba de micro cizallamiento. Resultados: los valores de resistencia de unión más significativos fueron encontrados en las cerámicas de disilicato de litio adherida con el adhesivo Palfique Bond y Tetric Bond teniendo una diferencia significativa (p= 0.001), los valores de resistencia de unión del adhesivo Palfique Bond y Tetric Bond en cerámica inyectada no tuvieron diferencia significativa. Conclusión: las cerámicas de disilicato de litio maquinadas presentan mejores valores de resistencia de unión al micro cizallamiento.


Introduction: lithium disilicate ceramics are an excellent choice in rehabilitation, made with the technique of injection or machining. The aim of this study was to evaluate the influence of two adhesive systems on the values of binding resistance in injected and machined lithium disilicate ceramics. Methods: lithium disilicate disks, IPS e. were used Max CAD (Ivoclar Vivadent, Liechtenstein, Swiss), 10mm in diameter and 1mm in thickness embedded in PVC tubes. Was distributed in 4 working groups, 2 in injected lithium ceramics and 2 in machined, Palfique Bond and Tetric N-bond Universal adhesives were applied according to the group distribution, then photopolymerized for 10 seconds with led light bulb, Tygon® tubes were placed for filling with fluid resin; once the Tygon® tubes were removed. The samples were taken to a universal testing machine where the micro-spraying test was performed. Results: the most significant binding resistance values were found in lithium disisilicate ceramics adhered with the Palfique Bond and Tetric Bond adhesive having a significant difference (p= 0,001), the bond strength values of the Palfique Bond and Tetric Bond adhesive in injected ceramic did not differ significantly. Conclusion: machined lithium disilicate ceramics have better values of binding resistance to micro-spraying.

16.
Braz. dent. j ; 33(5): 74-80, Sep.-Oct. 2022. tab, graf
Article Dans Anglais | LILACS-Express | LILACS, BBO | ID: biblio-1403788

Résumé

Abstract The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey's tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.


Resumo A longevidade da reabilitação protética é determinada pela estabilidade das interfaces implante e pilar. Conexões de cone Morse em restaurações dentárias têm se mostrado eficazes, porém a força de ativação ainda é empírica. Este trabalho comparou a força de ativação e contato interno do sistema cone Morse de acordo com a força de remoção. Oitenta conjuntos, compostos por implantes e pilares protéticos, foram avaliados com diferentes áreas de contato interno; 15,12mm2 (G3.3) e 21,25mm2 (G4.3). Os corpos-de-prova foram ativados a 0° e 30°, com cargas de 10, 20, 40 e 60N. Os corpos de prova foram submetidos ao ensaio de tração e os dados aos testes ANOVA e Tukey (α=0,05). Espécimes representativos foram examinados em MEV. A força de deslocamento do G3.3 (2,15±1,33MPa) não diferiu do G4.3 (1,99±1,03MPa). A ativação a 0º (2,95±0,98MPa) diferiu estatisticamente para 30º (1,19±0,54MPa). A carga de 60N foi estatisticamente superior para G3.3 e não houve diferença estatística entre 20N a 60N no G4.3. Os valores de 10N em 30o e 20N no longo eixo do implante cone morse, independente da área de contato friccional apresentaram o melhor assentamento.

17.
Rev.chil.ortop.traumatol. ; 63(2): 83-86, ago.2022. ilus, graf
Article Dans Espagnol | LILACS | ID: biblio-1436080

Résumé

OBJETIVO Determinar la resistencia máxima a la tracción (RMT) de la continuación prepatelar del cuádriceps (CPC).MATERIALES Y MÉTODOS Se realizó un estudio en cadáveres humanos. Fueron incluidos diez especímenes, en los cuales se utilizaron los tercios proximal y medial de la cortical anterior de la patela para evaluar las propiedades mecánicas de la CPC. En cada espécimen, se estudió un área de sección transversal de 0,2 cm2 (A1) y 1 cm2 (A2). Se aplicó una carga gradual para determinar la RMT.RESULTADOS La mediana de la RMT en el A1 fue de 232,56 N (rango: 141,23 N a 295,33 N) y en el A2 fue de 335,30 N (rango: 216,45 N a 371,40 N). El incremento en la TMR fue significativo entre las 2 áreas (p = 0,006).CONCLUSIÓN El ignificado clínico de este estudio es que la CPC es un tejido fuerte que puede servir de anclaje seguro para reconstrucciones alrededor de la patela. Un área relativamente pequeña tolera al menos 140 N y, a medida que crece el área, también aumenta la RMT.


OBJETIVE To determine the ultimate tensile strength (UTS) of the prepatellar quadriceps continuation (PQC). MATERIALS AND METHODS A human cadaveric study was performed. Ten fresh-frozen specimens were used. The proximal and medial thirds of the anterior cortex of the patella were used to assess the mechanical properties of the PQC. In each specimen, transverse section areas measuring 0.2 cm2 (A1) and 1 cm2 (A2) were studied. A gradual load was applied to determine the UTS. RESULTS The median UTS of A1 was of 232.56 N (range: 141.23 N to 295.33 N), and that of A2 was of 335.30 N (range: 216.45 N to 371.40 N). The increment in UTS was significant between the 2 areas (p » 0.006). CONCLUSION The clinical significance of the present study lies in the fact that it shows that the PQC is a strong tissue that can be a safe anchor for reconstruction around the patella. A relatively small area supports at least 140 N, and, as the area grows, the UTS increases as well.


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Sujet âgé , Résistance à la traction , Muscle quadriceps fémoral/physiopathologie , Phénomènes biomécaniques , Articulation du genou/physiopathologie
18.
Revista Naval de Odontologia ; 49(1): 36-42, 2022/07/04.
Article Dans Portugais, Anglais | LILACS-Express | LILACS | ID: biblio-1379036

Résumé

Adhesive systems play a fundamental role in the adhesion of restorative materials to dental substrates. To make this adhesion more effective and long-lasting, these materials are in constant evolution, seeking to simplify the clinical steps and reduce the technique's sensitivity. The most recent generation of adhesives developed is the universal adhesives, which promise versatility and reduction of clinical steps. The aim of this study was to perform a literature review on universal adhesives and their characteristics. The literature review was performed by means of an electronic search in the Pubmed database. The literature shows that these adhesives chemically bond to tooth substrates and produce more stable and less hydrophilic dentin interfaces. However, some limitations exist when the use in selfetching mode is performed on enamel, and selective conditioning of this substrate is recommended. The use of these adhesives as a silane or primer in the cementation of glass-ceramics and metal alloys has also shown limitations. Nevertheless, in the cementation of zirconia-based ceramics and indirect composite resin-based restorations, the procedure can be simplified by the use of universal adhesives. Adhesive strength on dentin substrates under different conditioning modes varied between studies. As with any new material, long-term clinical evaluations are needed to demonstrate the efficacy of these universal adhesive agents, as reported in this literature review.


Os sistemas adesivos têm papel fundamental na adesão de materiais restauradores aos substratos dentários. Para que esta adesão seja cada vez mais eficaz e duradoura, estes materiais encontram-se em constante evolução buscando a simplificação de passos clínicos e diminuição da sensibilidade da técnica. A mais recente geração de adesivos desenvolvida é a dos adesivos universais, os quais prometem versatilidade e redução de passos clínicos. O objetivo deste trabalho foi realizar uma revisão de literatura sobre os adesivos universais e suas características. O levantamento bibliográfico foi realizado por meio de uma busca eletrônica na base de dados Pubmed. A literatura mostra que estes adesivos ligam-se quimicamente aos substratos dentários e produzem interfaces dentinárias mais estáveis e menos hidrofílicas. No entanto, algumas limitações existem quando o uso no modo autocondicionante é realizado em esmalte, sendo recomendado o condicionamento seletivo deste substrato. O uso destes adesivos como silano ou primer na cimentação de cerâmicas vítreas e ligas metálicas também demonstrou limitações. No entanto, na cimentação de cerâmicas a base de zircônia e nas restaurações indiretas a base de resina composta, o procedimento pode ser simplificado pelo uso dos adesivos universais. A resistência adesiva em susbstrato dentinário sob diferentes modos de condicionamento variou entre os estudos. Como qualquer novo material, avaliações clínicas de longo prazo são necessárias para demonstrar a eficácia destes agentes adesivos universais, conforme relatado nesta revisão de literatura.

19.
Journal of Medical Biomechanics ; (6): E669-E675, 2022.
Article Dans Chinois | WPRIM | ID: wpr-961784

Résumé

Objective To compare the corneal biomechanical parameters identified from uniaxial tensile test under fast and slow loading. Methods The stress-strain and stress relaxation data were obtained from uniaxial tensile tests on corneal strips from 15 healthy adult rabbits at average loading rate of 0.16 mm/s and 0.02 mm/s, respectively. A visco-hyperelastic model was applied to analyze the loading and unloading data from the fast tensile tests, where the model parameter set was denoted by Gvh. The first-order Ogden model and second-order Prony series model were used to fit stress-strain and stress relaxation data from the slow tensile tests, respectively, in which the model parameter set was denoted by Gvh. Correlation analysis was used to compare the correlation of parameters between Gvh and GOP. Results All the goodness-of-fits to the three data sets were greater than 0.95. There were significant differences in 5 (μ, A1, A2, τ1, τ2,) of the 6 parameters between Gvh and GOP (P<0.05), and the Ogden model parameters was positively correlated between the two groups. Conclusions There are differences in corneal biomechanical parameters identified by data from uniaxial tensile tests under fast and slow loading. The results provide a preliminary research basis for further exploring the use of clinical data to identify corneal biomechanical properties.

20.
Journal of Peking University(Health Sciences) ; (6): 83-88, 2022.
Article Dans Chinois | WPRIM | ID: wpr-936116

Résumé

OBJECTIVE@#To investigate the effect of a noval radio-frequency atmospheric-pressure glow discharge (RF-APGD) plasma jet on crosslinking of dentin collagen.@*METHODS@#(1) Twenty intact third molars were collected. The middle dentin discs were prepared for each tooth by low-speed water-cooled Isomet saw, and then immersed in 10% (mass fraction) H3PO4 solution for 16 h to obtain fully demine-ralized dentin collagen. The twenty dentin discs were then randomly divided into five groups. The control group was untreated while the four experimental groups were treated by plasma jet with gas temperature of 4 ℃ for different times (20 s, 30 s, 40 s, and 50 s). The structure and crosslinking degree of dentin collagen were characterized by attenuated total reflection-Fourier transform infrared spectroscopy. The surface morphology of demineralized dentin was observed by scanning electron microscope, and the microstructure was observed by transmission electron microscope. (2) Fourty non-caries third molars were collected to prepare 5 g fine dentin powder, then completely demineralized with 10% H3PO4 solution. The control group was untreated, while the four experimental groups were treated by plasma jet for 20 s, 30 s, 40 s and 50 s. The crosslinking degree of each group was determined by ninhydrin colorimetric method. (3) Forty intact third molars were collected to obtain dentin strips. Only two central symmetrical dentin strips (nasty 80) were taken from each tooth and immersed in 10% H3PO4 solution for 16 h to obtain fully demineralized dentin collagen. Eighty dentine collagen fiber strips were randomly divided into five groups. The control group was untreated and the axial surfaces of dentin collagen fiber strips in the expe-rimental groups were treated with the plasma jet for 20 s, 30 s, 40 s and 50 s. The ultimate tensile strength of dentin was measured by universal mechanical machine.@*RESULTS@#(1) The surface morphology of demineralized dentin observed by scanning electron microscope showed that the network structure of collagen fibers on the surface of demineralized dentin treated with the plasma jet for 20 s, 30 s and 40 s could maintain the uncollapsed three-dimensional structure, and part of the microstructure was destroyed after plasma jet treated for 50 s. After being treated by plasma jet for 20 s, 30 s and 40 s, the three-dimensional structure was uncollapsed, and the typical periodic transverse pattern of natural type Ⅰ collagen fiber could be seen. The results of infrared spectra showed that the secondary conformation of dentin collagen fibers was the same as that of the control group after being treated with the plasma jet, and the intensity of amide band was significantly increased after being treated for 30 s and 40 s. (2) The results of ninhydrin crosslinking test showed that the crosslinking ratio of dentin collagen treated by plasma jet for 30 s and 40 s was the highest, and the difference was statistically significant (P < 0.05). (3) The results of dentin ultimate tensile strength showed that the control group was (1.67±0.24) MPa, and the plasma jet treated 20 s, 30 s, 40 s and 50 s groups were (4.21±0.15) MPa, (7.06±0.30) MPa, (7.32±0.27) MPa, and (6.87±0.17) MPa, which were significantly different from that of the control group (P < 0.05).@*CONCLUSION@#The novel RF-APGD plasma jet treatment can promote the crosslinking degree of demineralized dentin collagen and improve their ultimate tensile strength.


Sujets)
Collagène , Collage dentaire , Dentine , Agents de collage dentinaire , Microscopie électronique à balayage , Résistance à la traction