Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
The Korean Journal of Internal Medicine ; : 152-155, 2008.
Article Dans Anglais | WPRIM | ID: wpr-181612

Résumé

Bleeding in patients with liver cirrhosis is primarily caused by gastroesophageal varix in association with extensive collateral circulation, portal hypertensive gastropathy, a Mallory-Weiss tear and peptic ulcer disease. The spontaneous rupture of an artery, as a result of coagulopathy, is extremely rare in patients with liver cirrhosis; however, we recently observed a case of a spontaneous rupture of the lateral thoracic artery in a 47 year-old male patient with alcoholic liver cirrhosis. The patient expired despite repeated transcatheter arterial embolization of the lateral thoracic artery and best supportive care. This is, to our knowledge, the first documented case of the spontaneous rupture of the lateral thoracic artery in a patient with liver cirrhosis.


Sujets)
Humains , Mâle , Adulte d'âge moyen , /étiologie , Issue fatale , Cirrhose du foie/complications , Rupture spontanée/étiologie , Artères thoraciques/anatomopathologie , Facteurs temps
2.
Journal of Korean Medical Science ; : 37-41, 2004.
Article Dans Anglais | WPRIM | ID: wpr-20655

Résumé

The objective of this study was to develop a pre-clinical large animal model for the in vivo hemodynamic testing of prosthetic valves in the aortic position without the need for cardiopulmonary bypass. Ten male pigs were used. A composite valved conduit was constructed in the operating room by implanting a prosthetic valve between two separate pieces of vascular conduits, which bypassed the ascending aorta to the descending aorta. Prior to applying a side-biting clamp to the ascending aorta for proximal grafting to the aortic anastomosis, an aorta to femoral artery shunt was placed just proximally to this clamp. The heart rate, cardiac output, Vmax, transvalvular pressure gradient, effective orifice area and incremental dobutamine stress response were assessed. A dose dependant increase with dobutamine was seen in terms of cardiac output, Vmax, and the peak transvalvular pressure gradient both in the native and in the prosthetic valve. However, the increment was much steeper in the prosthetic valve. No significant differences in cardiac output were noted between the native and the prosthetic valves. The described pre-clinical porcine model was found suitable for site-specific in-vivo hemodynamic assessment of aortic valvular prosthesis without cardiopulmonary bypass.


Sujets)
Animaux , Mâle , Agonistes bêta-adrénergiques/pharmacologie , Aorte/anatomopathologie , Valve aortique/anatomopathologie , Modèles animaux de maladie humaine , Dobutamine/pharmacologie , Relation dose-effet des médicaments , Rythme cardiaque , Prothèse valvulaire cardiaque , Pression , Implantation de prothèse , Suidae , Artères thoraciques/anatomopathologie
SÉLECTION CITATIONS
Détails de la recherche