Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Southeast Asian J Trop Med Public Health ; 2008 Mar; 39(2): 195-9
Article Dans Anglais | IMSEAR | ID: sea-34403

Résumé

To study the distribution and localization of oil-soluble arteether in experimental mice, we injected C14-labelled arteether (20 microCi/kg body weight) intramuscularly and measured radioactivity in the blood, kidney, and liver. The labelled arteether distributed and localized more to the kidney (819,180.4 +/- 34,134 dpm/cm3) than the liver (288,628.9 +/- 54,954 dpm/cm3) 4 hours post-injection. The main localization of labelled arteether was in the kidney cortex rather than the medulla (p < 0.05). However, the distribution of radioactivity was homogeneous in the liver. The terminal half-life of labelled arteether in the blood was 1.8 hours. The blood:kidney:liver ratio was 1:5:2. These findings show that labelled arteether was distributed quickly and localized in the cytoplasmic cortex of the kidney and homogeneously in the liver.


Sujets)
Animaux , Antipaludiques/pharmacocinétique , Artémisinines/pharmacocinétique , Radio-isotopes du carbone/diagnostic , Période , Rein/métabolisme , Foie/métabolisme , Mâle , Souris , Distribution tissulaire
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(3): 371-383, jul.-set. 2007. ilus, graf
Article Dans Portugais | LILACS | ID: lil-468144

Résumé

A malária é a endemia tropical mais devastadora do mundo e esse quadro é agravado pela ausência de tratamento eficaz. Entretanto, a resistência dos plasmódios à artemisinina não apresenta relevância clínica e seu mecanismo de ação está associado ao grupo heme, com formação de radicais livres e rompimento da ponte endoperóxido. O comportamento voltamétrico da artemisinina foi estudado por voltametria cíclica e voltametria de onda quadrada. O fármaco é irreversivelmente reduzido em eletrodos de carbono vítreo e os valores de potencial de pico não sofrem influência da acidez do meio, porém observou-se o maior valor de corrente em pH 6,0. O comportamento voltamétrico da artemisinina foi significativamente alterado na presença do grupo heme, provocando uma antecipação de seu pico de redução em cerca de 600 mV. Por voltametria de onda quadrada observou-se que este novo pico foi sensível à adição crescente de concentração de hemina, atingindo valor de corrente cerca de 10 vezes maior em relação ao pico original da artemisinina, numa relação de concentração de 20 mmol/L para o primeiro e 50 mmol/L do segundo. Além disso, resultados indicaram que esse processo eletrocatalítico ocorreu pela formação de Fe(II)-hemina na superfície do eletrodo, com provável processo de eletro-polimerização da hemina sobre o eletrodo de carbono vítreo. Esse efeito adsortivo foi avaliado a partir da estimativa da concentração superficial (G) de hemina sobre o eletrodo de trabalho em pH 6,0. A modificação do eletrodo de carbono vítreo por hemina mostrou que a interação entre artemisinina e o grupo heme ocorre predominantemente sobre a superfície do eletrodo e não em solução. Portanto, esclarecer o mecanismo de ação da artemisinina é importante para o planejamento e desenvolvimento de novos agentes antimaláricos.


Malaria is the tropical disease most devastating of the world and this situation is worsened by the absence of effective treatment. However, the plasmodium resistance to artemisinin does not show clinical relevance. The drug mechanism of action is associated to the heme group, with free radical formation and endoperoxide moiety breakage. The voltammetric behavior of artemisinin was studied by cyclic and square-wave voltametries. This drug was irreversibly reduced on glassy carbon electrode and the peak potential values are pH independent, however the biggest value of current peak was observed at pH 6.0. The voltammetric behavior of artemisinin was significantly changed in the heme group presence, provoking an anticipation of about 600 mV on cathodic peak. By square-wave voltammetry it was observed that this new peak was sensitive to the hemin concentration, reaching a value around 10 times larger regarding the original cathodic peak of artemisinin, being the concentration of 20 mmol/L for the former and 50 mmol/L for the latter. In addition, results indicated that this electro-catalytic process depends on the Fe(II)-hemin formation on the electrode surface, indicating the possible electro-polymerization of hemin on the glassy carbon electrode. This adsorptive effect was evaluated from the superficial concentration (G) estimation of the hemin on the working electrode at pH 6.0. The modification of the glassy carbon electrode using hemin showed that the interaction between artemisinin and the heme group predominantly occurs on the electrode surface and not in solution. Therefore, clarifying artemisinin mechanism of action is important in order to contribute for the design and development of new antimalarial agents.


Sujets)
Artémisinines/pharmacocinétique , Résistance aux substances , Paludisme/métabolisme , Paludisme/thérapie , Plasmodium falciparum , Chimie pharmaceutique , Hémine
SÉLECTION CITATIONS
Détails de la recherche