Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
1.
Einstein (Säo Paulo) ; 14(3): 423-430, July-Sept. 2016. tab, graf
Article Dans Anglais | LILACS | ID: lil-796980

Résumé

ABSTRACT There is a growing request for measuring intra-abdominal pressure in critically ill patients with acute abdominal pain to be clarified. Summarizing the research results on measurement of vesical intra-abdominal pressure and analyzing the level of evidence were the purposes of this integrative literature review, carried out based on the databases LILACS, MEDLINE and PubMed, from 2005 to July 2012. Twenty articles were identified, in that, 12 literature reviews, 4 descriptive and exploratory studies, 2 expert opinions, one prospective cohort study and one was an experience report. The vesical intra-abdominal pressure measurement was considered gold standard. There are variations in the technique however, but some common points were identified: complete supine position, in absence of abdominal contracture, in the end of expiration and expressed in mmHg. Most research results indicate keeping the transducer zeroed at the level of the mid-axillary line at the iliac crest level, and instill 25mL of sterile saline. Strong evidence must be developed.


RESUMO Em pacientes críticos com quadros abdominais agudos a esclarecer é crescente a solicitação da aferição da pressão intra-abdominal. Sintetizar resultados de pesquisas sobre a mensuração da pressão intra-abdominal pela via vesical e analisar o nível de evidência foram os objetivos desta revisão integrativa da literatura, realizada nas bases LILACS, MEDLINE e PubMed, no período de 2005 a julho de 2012. Identificaram-se 20 artigos, sendo 12 revisões de literatura, 4 estudos exploratório-descritivos, 2 opiniões de especialistas, 1 estudo de coorte prospectivo e 1 relato de experiência. O método vesical para mensuração da pressão intra-abdominal foi considerado padrão-ouro. Existem variações na técnica, entretanto pontos em comum foram identificados: posição supina completa, na ausência de contratura abdominal, ao final da expiração e expressa em mmHg. A maioria indica posicionar o ponto zero do transdutor na linha axilar média, ao nível da crista ilíaca e instilar 25ml de solução salina estéril. Evidências fortes precisam ser desenvolvidas.


Sujets)
Humains , Pression , Cathétérisme urinaire/méthodes , Cavité abdominale/physiopathologie , Hypertension intra-abdominale/diagnostic , Chlorure de sodium/administration et posologie , Illustration médicale , Monitorage physiologique/instrumentation , Monitorage physiologique/méthodes
2.
Clinics ; 62(2): 145-150, Apr. 2007. graf
Article Dans Anglais | LILACS | ID: lil-449654

Résumé

OBJECTIVE: To study the effect of hemodialysis on intra-abdominal pressure. METHODS: Five patients admitted between July and November of 2003 were evaluated in the intensive care unit. Intra-abdominal pressure was measured before and after hemodialysis, maintaining the ventilatory parameters except for PEEP (positive-end expiratory pressure). RESULTS: Intra-abdominal pressure was significantly reduced by hemodialysis in all the 5 patients. CONCLUSION: Hemodialysis significantly reduced intra-abdominal pressure in the 5 patients, an effect which could have influence over other organic systems. This reduction is related to the weight variation before and after hemodialysis, as well as to the loss of volume caused by this procedure.


OBJETIVO: Pesquisar o efeito da hemodiálise sobre a pressão intra-abdominal. MÉTODOS: Foram avaliados cinco pacientes internados entre julho e novembro de 2003, na Unidade de Terapia Intensiva do Serviço de Nefrologia do Hospital das Clínicas de São Paulo. Mensurou-se a pressão intra-abdominal antes e após a hemodiálise, mantendo os parâmetros ventilatórios exceto a PEEP (positive end expiratory pressure). RESULTADOS: Constatou-se que a hemodiálise foi capaz de reduzir significativamente a PIA em cinco pacientes na Unidade de Terapia Intensiva CONCLUSÃO: A hemodiálise reduziu a pressão intra-abdominal numa amostra de cinco pacientes, de maneira significativa, o que poderia influenciar os demais sistemas orgânicos. Essa redução está relacionada com a variação de peso pré e pós-hemodiálise, e com a perda de volume promovida pelo procedimento.


Sujets)
Adulte , Sujet âgé , Femelle , Humains , Mâle , Adulte d'âge moyen , Cavité abdominale/physiopathologie , Monitorage physiologique/méthodes , Dialyse rénale , Ventilation artificielle , Syndrome des loges/diagnostic , Ventilation à pression positive , Dialyse rénale/effets indésirables , Dialyse rénale/normes
SÉLECTION CITATIONS
Détails de la recherche