Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
Odovtos (En línea) ; 24(1)abr. 2022.
Article Dans Anglais | LILACS, SaludCR | ID: biblio-1386582

Résumé

Abstract The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. In this study, three bulk-fill composites- SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), and one conventional composite resin G-ænial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24°C) and at 55°C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37°C for 24 hours. The depth of cure was calculated using a bottom/top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. When comparing the baseline and the 24- hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm.


Resumen El objetivo fue investigar el efecto del precalentamiento de tres resinas Bulk-fill, una resina compuesta convencional sobre la microdureza Vickers y la profundidad de curado de estas resinas. Se utilizaron tres composites Bulk-Fill-SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), y una resina compuesta convencional G-ænial POSTERIOR (GP) como grupo de control. Las muestras se obtuvieron a temperatura ambiente (24°C) y a 55°C en modo T2 después de haber sido colocadas en un dispositivo de calentamiento durante 10 minutos. Se dividieron en ocho grupos (n=10) según el tipo de material y el proceso de calentamiento que se utilizó (precalentado y no calentado). Se probaron con un medidor de microdureza Vickers (VHN) en las superficies inferior y superior. Las primeras mediciones se obtuvieron en la línea de base; la segunda se realizó después de que las muestras se almacenaran en agua destilada a 37°C durante 24 horas. La profundidad de curado se calculó utilizando una relación de dureza inferior/ superior de las mediciones. El análisis estadístico se realizó utilizando el SPSS V23 y las pruebas de Shapiro-Wilk. Por último, se utilizó la prueba de Duncan para las comparaciones múltiples (p<0,05). VHN aumentó tras el procedimiento de precalentamiento en las resina Bulk-Fill, disminuyó en los GP. No hubo diferencias entre los valores de VHN de referencia y de 24 horas en SDR y GP. Después de 24 horas, mientras que el VHN de EST aumentó, el VHN de AFX disminuyó. No hubo diferencias entre los ratios de dureza de las muestras de AFX y EST (p<0,001) y los ratios de dureza fueron mayores que los de GP y SDR. Al comparar los valores de referencia y los de 24 horas, el VHN dependió del tipo de materiales. Se obtuvo una profundidad de curado suficiente en todos los grupos con un grosor de 2mm.


Sujets)
Résines composites/analyse , Chaufferettes
2.
Biosci. j. (Online) ; 29(3): 703-711, may/june 2013.
Article Dans Portugais | LILACS | ID: biblio-914605

Résumé

Este trabalho teve como objetivo avaliar protótipos de aquecedor solar para pintinhos com 1,0; 1,5 e 2,0 m de diâmetro (tratamentos AQ1, AQ2 e AQ3, respectivamente) com base nos índices de conforto térmico no município de Marechal Candido Rondon, Paraná. Valores de temperatura de globo negro, bulbo seco, bulbo úmido e velocidade do vento foram registrados acima do dissipador e nas condições externas. Os dados foram coletados a cada duas horas, entre 08h00min e 16h00min durante o período experimental. Com base em valores horários por aquecedor, o Índice de Temperatura e Umidade (ITU) e o Índice de Temperatura Globo Umidade (ITGU) não apresentaram resultados que diferenciassem entre os coletores avaliados. A maior Carga Térmica de Radiação (CTR) foi observada para AQ1 e AQ2 às 14 h. Quando se comparam os aquecedores, independente do horário de observação, verifica-se que os maiores valores de ITU e ITGU ocorreram para AQ1 e AQ3 e a CTR para AQ1. O horário para o qual foram observados os maiores valores destes índices foi às 14 h. Concluiu-se que o sistema de aquecimento pode se constituir uma alternativa para uso em aviários já que propicia condições de conforto térmico semelhante aos sistemas empregados comercialmente.


This study had as objective to evaluate prototypes of solar heater for broiler chicken with diameter of 1.0; 1.5 and 2.0 m (treatments AQ1, AQ2 and AQ3, respectively) based on the thermal comfort indexes in Marechal Candido Rondon, Paraná State, Brazil. The values of black globe temperature, dry bulb, wet bulb and wind speed were registered above the heater and in the external conditions. Data were collected each two hours, between 8:00 AM and 4:00 PM during the experimental period. Based on hourly values for heater, the Temperature and Humidity Index (THI) and the Black Globe Humidity Index (BGHI) didn't present results that differentiated the appraised heaters. The highest value of Thermal Heat Load (THL) was observed for AQ1 and AQ2 at 2:00 PM. When the heaters are compared, independent of the observation schedule, was verified that the largest values of THI and BGHI occurred for AQ1 and AQ3 and CTR for AQ1. The time which were observed the largest values of these indexes was 2:00 PM. It was concluded that the heating system can be constituted an alternative for use in aviaries considering that provide similar conditions of thermal comfort that the commercial systems.


Sujets)
Volaille , Oiseaux , Équipement et fournitures , Chaufferettes
3.
Investig. segur. soc. salud ; 15(1): 29-37, 2013. tab, ilus
Article Dans Espagnol | LILACS, COLNAL | ID: biblio-967982

Résumé

El monóxido de carbono (CO) es un gas tóxico, inodoro e incoloro que se produce por la combustión incompleta de los hidrocarburos. Las principales fuentes de este veneno son los vehículos motorizados, los calentadores, los aparatos que utilizan el carbono como combustible y el fuego dentro de los hogares. Los síntomas que vienen a definir la intoxicación por CO son: cefaleas, vértigo, disnea, confusión, midriasis, convulsiones y coma. Objetivo: Describir el comportamiento de la intoxicación aguda por CO intramural durante 2011 en Bogotá, D. C., a través de los casos reportados por los diferentes sistemas de información en salud y ambientales. Métodos: Estudio descriptivo; se tuvo en cuenta la información de base de datos del Sistema Nacional de Vigilancia en Salud Pública (Sivigila) en 2011. La información fue tabulada con Microsoft Excel. Los análisis fueron realizados en STATA 9 y Epidat 3.1. Resultados: Para 2011 se presentaron 19 brotes de intoxicación por CO en el distrito, que afectaron, en total, a 60 personas. Durante el mismo año ocurrieron 4 muertes a causa de esta clase de envenenamiento. El promedio de edad de intoxicación estuvo en los 27 años; la menor de sus víctimas tenía un año, y las mayores, 80 años. En cuanto al sitio de ocurrencia, la localidad que reportó más casos fue Suba, seguida de Usaquén y Usme. Discusión: Hay subregistro frente a la ocurrencia de los casos de intoxicación por CO que no son atendidos en los servicios de salud y de los que producen la muerte inmediata y son llevados directamente a Medicina Legal, además de las fallas que se siguen identificando; también, fallas de clasificación del evento frente a la ocurrencia de intoxicaciones por CO y de calidad en algunos registros del Sivigila.


Introduction: Carbon monoxide (CO) is a toxic, odorless, colorless gas, produced by the incomplete combustion of hydrocarbons. The main sources for this toxic gas are motorized vehicles, heaters, machinery that uses coal as fuel, and fire in closed spaces like houses. Symptoms for this type of intoxication include headaches, vertigo, dyspnea, confusion, mydriasis, seizures, and coma. Objective: The main objective is to describe the behavior of acute intoxication caused by carbon monoxide in closed spaces in Bogota during 2011, through reported cases by different healthcare and environmental systems. Methods: Descriptive study with information obtained from SIVIGILA 2011 database. Data was tabulated with Microsoft Excel, and analysis was done with STATA 9 and Epidat 3.1. Results: In 2011, 60 individuals were affected by 19 different outbreaks. During this year, 4 intoxications caused by carbon monoxide resulted fatal. The average age for intoxication was 27. The youngest reported patient was 1 year old, while the oldest was 80 years old. Suba was the district with higher reported cases, followed by Usaquen and Usme. Discussion: Under-reporting for cases involving intoxication by carbon monoxide occurs, as some are not reported by any healthcare system. The same happens for lethal intoxication cases taken directly to Legal Medicine that are not reported. Other problems arise, like failure to classify events as carbon monoxide intoxication, and lack of quality in some SIVIGILA reports.


O monóxido de carbono (CO) é um gás tóxico, incolor, inodoro e é produzido pela combustão incompleta de hidrocarbonetos. As principais fontes deste veneno são os automóveis, aquecedores, aparelhos que usam carvão como combustível, e o fogo utilizado dentro das casas. Os sintomas que definem esta intoxicação são dor de cabeça, tontura, dispnéia, confusão, midríase, convulsões e coma. Objetivo: Descrever o comportamento da intoxicação aguda do monóxido de carbono intramural de 2011, em Bogotá através dos casos apresentados nos sistemas de saúde e ambiental. Métodos: Estudo descritivo que levou em conta as informações da base dados de SIVIGILA de 2011, os dados foram tabulados com o Microsoft Excel. As análises foram realizadas no STATA 9 e Epidat 3.1. Resultados: Para o ano de 2011, apresentaram 19 casos no distrito, afetando 60 pessoas. Durante este ano ocorreu quatro mortalidades devido a intoxicação por monóxido de carbono. A média de idade dos intoxicados foi de 27 anos, o caso mais jovem foi de 1 ano e mais velho foi de 80 anos. Com relação ao local de ocorrência, a cidade que registrou mais casos foi Suba, seguida por Usaquén e Usme. Discussão: Há uma subnotificação de ocorrência de casos de intoxicação por monóxido de carbono que não são atendidos nos serviços de saúde e aqueles que causam a morte imediata e são levados diretamente à Medicina Legal, além das falhas que continuam sendo identificadas; falhas na classificação de eventos e a ocorrência de intoxicação por monóxido de carbono e qualidade em alguns registros SIVIGILA.


Sujets)
Humains , Mâle , Femelle , Intoxication au monoxyde de carbone , Intoxication au gaz , Carbone , Épidémies de maladies , Gas Toxiques , Mort , Prestations des soins de santé , Chaufferettes , Surveillance épidémiologique
SÉLECTION CITATIONS
Détails de la recherche