Aim: To evaluate the influence of quartz tungsten halogen and plasma arc curing (PAC) lights on Knoop hardness and change in polymerization temperature of resin composite. Materials and Methods: Filtek Z250 and Esthet X composites were used in the shade A3. The temperature increase was registered with Type-k thermocouple connected to a digital thermometer (Iopetherm 46). A self-cured polymerized acrylic resin base was built in order to guide the thermocouple and to support the dentin disk of 1.0 mm thickness obtained from bovine tooth. On the acrylic resin base, elastomer mold of 2.0 mm was adapted. The temperature increase was measured after composite light curing. After 24 h, the specimens were submitted to Knoop hardness test (HMV-2000, Shimadzu, Tokyo, Japan). Data were submitted to ANOVA and Tukey's test (a = 0.05). Results: For both composites, there were no significant differences (P > 0.05) in the top surface hardness; however, PAC promoted statistically lower (P < 0.05) Knoop hardness number values in the bottom. The mean temperature increase showed no significant statistical differences (P > 0.05). Conclusion: The standardized radiant exposure showed no influence on the temperature increase of the composite, however, showed significant effect on hardness values.


Sujets)
Analyse de variance , Animaux , Bovins , Résines composites/composition chimique , Résines composites/effets des radiations , Lampes à photopolymériser dentaires/classification , Lampes à photopolymériser dentaires/normes , Émail dentaire/effets des médicaments et des substances chimiques , Matériaux dentaires/composition chimique , Matériaux dentaires/effets des radiations , Restaurations dentaires permanentes/normes , Dureté/effets des radiations , Température élevée , Photopolymérisation d'adhésifs dentaires/méthodes , Valeurs de référence , Statistique non paramétrique
2.
Braz. oral res ; 23(2): 108-112, 2009. tab
Article Dans Anglais | LILACS | ID: lil-522289

Résumé

This study evaluated the Knoop hardness of a dual-cured resin cement (Rely-X ARC) activated solely by chemical reaction (control group) or by chemical / physical mode, light-cured through a 1.5 mm thick ceramic (HeraCeram) or composite (Artglass) disc. Light curing was carried out using conventional halogen light (XL2500) for 40 s (QTH); light emitting diodes (Ultrablue Is) for 40 s (LED); and Xenon plasma arc (Apollo 95E) for 3 s (PAC). Bovine incisors had their buccal face flattened and hybridized. On this surface a rubber mold (5 mm in diameter and 1 mm in height) was bulk filled with the resin cement. A polyester strip was seated for direct light curing or through the discs of veneering materials. After dry storage in the dark (24 h 37°C), the samples (n = 5) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50 gF load 15 s). The data were statistically analyzed by ANOVA and Tukey's test (á = 0.05). The cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values.


Sujets)
Animaux , Bovins , Lampes à photopolymériser dentaires , Facettes dentaires , Photopolymérisation d'adhésifs dentaires/méthodes , Céments résine/effets des radiations , Autopolymérisation de résines dentaires , Lampes à photopolymériser dentaires/normes , Essais de dureté , Test de matériaux , Céments résine/composition chimique , Propriétés de surface , Facteurs temps