Rev. chil. anest ; 51(1): 102-116, 2022. ilus
Article Dans Espagnol | LILACS | ID: biblio-1568055

Résumé

In anesthesia practice, mechanical ventilation is a fundamental tool, and its correct configuration is essential in the patients care. Airway pressure is often assumed to reflect the forces applied to the lung and is used to monitor mechanical ventilation. This assumption is erroneous because pressure acts on the respiratory system as a whole and the impact on its components will depend on the ratio of lung and respiratory system elastances. In turn, patients' lungs with the same body size and ventilated with the same tidal volume, may be subjected to different forces depending on their functional size. This is expressed under the concepts of stress and strain. Its surrogate owners, the Paw plateau and the Vt, have shown a poor correlation compared to transpulmonary pressure and the airway driving pressure. This review aims to provide the theoretical-practical tools necessary to optimize mechanical ventilation for each patient.


En la práctica anestésica, la ventilación mecánica es una herramienta fundamental, y su correcta configuración es esencial en el cuidado de los pacientes. La presión de la vía aérea es, muchas veces, asumida como el reflejo de las fuerzas aplicadas en el pulmón y es utilizada para monitorizar la ventilación mecánica. Esta asunción es errónea porque la presión actúa sobre el sistema respiratorio en su totalidad y la repercusión sobre sus componentes va a depender de la relación de elastancias del pulmón y el sistema respiratorio. A su vez, los pulmones de pacientes con el mismo tamaño corporal y ventilados con el mismo volumen corriente, pueden estar sujetos a diferentes fuerzas dependiendo de su tamaño funcional. Esto es expresado bajo los conceptos de stress y strain. Sus respectivos subrogantes, Pawplateau y el Vt, han demostrado tener una pobre correlación en comparación con la presión transpulmonar y la airway driving pressure. Esta revisión pretende brindar las herramientas teórico-prácticas necesarias para optimizar la ventilación mecánica para cada paciente.


Sujets)
Humains , Ventilation artificielle , Stress physiologique , Mécanique respiratoire/physiologie , Pression , Élasticité
2.
Rev. bras. ter. intensiva ; 32(3): 398-404, jul.-set. 2020. tab, graf
Article Dans Anglais, Portugais | LILACS | ID: biblio-1138504

Résumé

RESUMO Objetivo: Avaliar a reprodutibilidade intra e interexaminador das mensurações da resistência e das complacências estática e dinâmica do sistema respiratório em pacientes sob ventilação mecânica. Métodos: Trata-se de estudo analítico realizado com indivíduos com idade ≥ 18 anos, em ventilação mecânica invasiva, que não tinham diagnóstico clínico de doença do aparelho respiratório e/ou anormalidade de caixa torácica. Foram realizadas três aferições da mecânica respiratória com intervalo de 1 minuto entre elas. A primeira e a terceira aferições foram realizadas pelo avaliador A e a segunda aferição, pelo avaliador B. A comparação dos valores de resistência e complacências estática e dinâmica do sistema respiratório foi calculada por meio do coeficiente de correlação intraclasse. Resultados: Foram realizadas 198 aferições da mecânica respiratória em 66 pacientes sob ventilação mecânica, com idade média de 52,6 ± 18,6 anos, índice de massa corporal médio de 21,6 ± 2,1kg/m2, predomínio do perfil cirúrgico (61,5%) e sexo feminino (53,8%). Foram obtidos valores médios das três aferições para resistência do sistema respiratório (A1: 15,7 ± 6,8cmH2O/L/s; B1: 15,7 ± 6,4cmH2O/L/s e A2: 15,9 ± 6,2cmH2O/L/s), para complacência estática do sistema respiratório (A1: 42,1 ± 13,7mL/cmH2O; B1: 42,4 ± 14,6mL/cmH2O e A2: 42,2 ± 14,5mL/cmH2O) e para complacência dinâmica do sistema respiratório (A1: 21,3 ± 7,3mL/cmH2O; B1: 21,4 ± 7,5mL/cmH2O e A2: 21,3 ± 6,2mL/cmH2O). Também foram encontrados valores do coeficiente de correlação intraclasse para resistência do sistema respiratório (R = 0,882 e p = 0,001; R = 0,949 e p = 0,001 - interexaminadores A1 versus B e B versus A2, respectivamente; R = 0,932 e p = 0,001 - intraexaminador); complacência estática do sistema respiratório (R = 0,951 e p = 0,001; R = 0,958 e p = 0,001 - interexaminadores A1 versus B e B versus A2, respectivamente; R = 0,965 e p = 0,001 - intraexaminador) e complacência dinâmica do sistema respiratório (R = 0,957 e p = 0,001; R = 0,946 e p = 0,001 - interexaminadores A1 versus B e B versus A2 respectivamente; R = 0,926 e p = 0,001 - intraexaminador). Conclusão: A mensuração de mecânica respiratória apresenta boa reprodutibilidade intra e interexaminador para as aferições de resistência e complacências estática e dinâmica do sistema respiratório em pacientes ventilados.


ABSTRACT Objective: To evaluate the intra- and interexaminer reproducibility of measurements of the resistance and static and dynamic compliance of the respiratory system in patients on mechanical ventilation. Methods: This was an analytical study conducted with individuals aged ≥ 18 years who were on invasive mechanical ventilation and had no clinical diagnosis of respiratory system disease and/or chest abnormality. Three measurements of respiratory mechanics were performed with a 1-minute interval between them. The first and third measurements were performed by examiner A, the second by examiner B. The values for the resistance and static and dynamic compliance of the respiratory system were compared using the intraclass correlation coefficient. Results: A total of 198 measurements of respiratory mechanics were performed for 66 patients on mechanical ventilation. The patients had a mean age of 52.6 ± 18.6 years and a mean body mass index of 21.6 ± 2.1kg/m2; a surgical profile (61.5%) and female sex (53.8%) were predominant. Mean values were obtained for the three measurements of respiratory system resistance (A1: 15.7 ± 6.8cmH2O/L/s; B1: 15.7 ± 6.4cmH2O/L/s and A2: 15.9 ± 6.2cmH2O/L/s), respiratory system static compliance (A1: 42.1 ± 13.7mL/cmH2O; B1: 42.4 ± 14.6mL/cmH2O and A2: 42.2 ± 14.5mL/cmH2O) and respiratory system dynamic compliance (A1: 21.3 ± 7.3mL/cmH2O; B1: 21.4 ± 7.5mL/cmH2O and A2: 21.3 ± 6.2mL/cmH2O). The intraclass correlation coefficient was also calculated for respiratory system resistance (R = 0.882 and p = 0.001; R = 0.949 and p = 0.001 - interexaminer A1 versus B and B versus A2, respectively; R = 0.932 and p = 0.001 - intraexaminer); respiratory system static compliance (R = 0.951 and p = 0.001; R = 0.958 and p = 0.001 - interexaminer A1 versus B and B versus A2, respectively; R = 0.965 and p = 0.001 - intraexaminer) and respiratory system dynamic compliance (R = 0.957 and p = 0.001; R = 0.946 and p = 0.001 - interexaminer A1 versus B and B versus A2, respectively; R = 0.926 and p = 0.001 - intraexaminer). Conclusion: The measurements of resistance and static and dynamic compliance of the respiratory system show good intra- and interexaminer reproducibility for ventilated patients.


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Sujet âgé , Ventilation artificielle/méthodes , Mécanique respiratoire/physiologie , Résistance des voies aériennes/physiologie , Compliance pulmonaire/physiologie , Reproductibilité des résultats
3.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 38: e2018259, 2020. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1092119

Résumé

ABSTRACT Objective: To verify whether the overlapping of ventilatory stimuli, resulting from playing with blowing toys, changes the respiratory mechanics of healthy schoolchildren. Methods: Cross-sectional study with healthy schoolchildren aged seven to 14 years old from Florianópolis, Santa Catarina, Southern Brazil. Spirometric data were obtained, a health questionnaire and the International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire were also applied. The procedure consisted of playing with the following blow toys in a random order: soap bubbles, party whistles and balloon. Before and after the intervention, the assessment of respiratory mechanics was carried out by impulse oscillometry - IOS (Erich Jaeger, Germany®). The ANOVA for repeated measures test was applied. Results: 71 students of both genders with mean age of 9.7±2.1 years participated in the study. Results showed a progressive decrease of impedance (Z5), total airway resistance (R5) and resonance frequency (Fres) when the moment before the use of the first toy was compared with the moment after the third toy (Z5/p=0.048; R5/p=0.049; Fres/p=0.004). Fres also differed between the moment before the first and the second toy (p=0.048). After the use of each of the three blowing toys, the oscillometric parameters did not differ. Conclusions: The difference in oscillometric parameters of R5 before the use of each toy indicates that the overlap of ventilatory stimuli produced by them provided a reduction in the R5.


RESUMO Objetivo: Verificar se a sobreposição de estímulos ventilatórios decorrentes da execução de brinquedos de sopro altera a mecânica respiratória de escolares saudáveis. Métodos: Estudo transversal com escolares saudáveis de sete a 14 anos de idade, provenientes de Florianópolis, Santa Catarina, Brasil. Foram obtidos dados espirométricos e realizada aplicação de um recordatório de saúde e do questionário International Study of Asthma and Allergies in Childhood (ISAAC). A coleta de dados consistiu na aplicação dos brinquedos bola de sabão, língua de sogra e balão de forma aleatória. Antes e após a intervenção foi realizada a avaliação da mecânica respiratória por meio da oscilometria de impulso - IOS (Erich Jaeger, Germany®). Aplicou-se o teste de ANOVA para medidas repetidas. Resultados: Participaram do estudo 71 escolares de ambos os sexos, com média de idade de 9,7±2,1 anos. Houve redução progressiva na impedância respiratória a 5 hertz (Z5), na resistência total das vias aéreas (resistência a 5 hertz - R5) e na frequência de ressonância (Fres) ao comparar o momento antes do uso do primeiro e do terceiro brinquedo (Z5/p=0,048; R5/p=0,049; Fres/p=0,004). Fres também diferiu no momento antes do primeiro e do segundo brinquedo (p=0,048). Após o uso de cada um dos três brinquedos, os parâmetros oscilométricos não diferiram. Conclusões: Observando a diferença nos parâmetros oscilométricos da R5 antes do uso de cada um dos brinquedos, notou-se que a sobreposição de estímulos ventilatórios produzidos por eles proporcionou uma redução na R5.


Sujets)
Humains , Mâle , Femelle , Enfant , Adolescent , Oscillométrie/méthodes , Jeu et accessoires de jeu , Mécanique respiratoire/physiologie , Spirométrie , Résistance des voies aériennes/physiologie , Études transversales , Volontaires sains , Analyse de fréquence de résonance/méthodes
4.
Rev. bras. ter. intensiva ; 31(4): 483-489, out.-dez. 2019. tab, graf
Article Dans Espagnol | LILACS | ID: biblio-1058049

Résumé

RESUMEN Objetivo: Describir el comportamiento del componente resistivo ante el incremento de la presión positiva espiratoria final (PEEP) en pacientes con síndrome de distrés respiratorio agudo ventilados con una estrategia de ventilación protectora. Métodos: En modo controlada por volumen, a 6mL/Kg y flujo constante se realizaron oclusiones teleinspiratorias a PEEP 0, 5 10, 15 y 20cmH2O. Se obtuvieron valores de presión pico, inicial, plateau y se calculó resistencias máxima, mínima y diferencial. Las comparaciones se realizaron mediante test de ANOVA para muestras relacionadas con corrección post hoc de Bonferroni. Se consideró significativo una p < 0,05. Resultados: La resistencia máxima más elevada se observó en los niveles de PEEP más bajos. Los valores de PEEP 10 y 15cmH2O tuvieron diferencias significativas con PEEP 5 y 0cmH2O, mientras que PEEP 20cmH2O únicamente con PEEP 0cmH2O (p < 0,05). La resistencia mínima tuvo la misma conducta que la resistencia máxima. A partir de PEEP 10cmH2O todos tuvieron diferencias significativas con PEEP 0 y 5cmH2O (p < 0,05). La resistencia diferencial se expresó de manera opuesta a la resistencia máxima y mínima. El único nivel de PEEP que experimentó diferencias significativas con PEEP 0 y 5cmH2O fue PEEP 20cmH2O. También hubo diferencias entre PEEP 15 y PEEP 5cmH2O (p < 0,05). Conclusiones: Durante ventilación protectora en pacientes com síndrome de distrés respiratorio agudo, la resistencia máxima del sistema respiratorio tiene un comportamiento decreciente con la PEEP y refleja la respuesta que tiene la resistencia mínima. Mientras que la resistencia diferencial mantiene su conducta creciente con los valores de PEEP.


ABSTRACT Objective: To describe the behavior of inspiratory resistance components when positive end-expiratory pressure (PEEP) increases in patients with acute respiratory distress syndrome under a protective ventilation strategy. Methods: In volume-controlled mode, at 6mL/kg and constant flow, end-inspiratory occlusions were performed at 0, 5 10, 15 and 20cmH2O PEEP. Peak, initial and plateau pressure values were assessed, calculating the maximum, minimum and differential resistances. The results were compared by repeated measures analysis of variance (ANOVA) with post hoc Bonferroni correction, considering p < 0.05 significant. Results: The highest maximum resistance was observed at the lowest PEEP levels. The values for 10 and 15cmH2O PEEP significantly differed from those for 5 and 0cmH2O PEEP, whereas that for 20cmH2O PEEP only significantly differed from that for 0cmH2O PEEP (p < 0.05). The minimum resistance behaved similarly to the maximum resistance; the values for PEEP levels from 10cmH2O to 20cmH2O significantly differed from those for 0 and 5cmH2O PEEP (p < 0.05). Differential resistance showed the opposite variation to the maximum and minimum resistances. The only PEEP level that showed significant differences from 0 and 5cmH2O PEEP was 20cmH2O PEEP. Significant differences were also found between 15 and 5cmH2O PEEP (p < 0.05). Conclusions: During protective ventilation in patients with acute respiratory distress syndrome, the maximum resistance of the respiratory system decreases with PEEP, reflecting the minimum resistance response, whereas differential resistance increases with PEEP.


Sujets)
Humains , Mâle , Femelle , Syndrome de détresse respiratoire du nouveau-né/thérapie , Mécanique respiratoire/physiologie , Ventilation à pression positive , Ventilation artificielle/méthodes , Syndrome de détresse respiratoire du nouveau-né/physiopathologie , Volume courant , Études transversales , Études rétrospectives
5.
Fisioter. Pesqui. (Online) ; 26(3): 265-274, jul.-set. 2019. tab, graf
Article Dans Portugais | LILACS | ID: biblio-1039882

Résumé

RESUMO Este trabalho teve como objetivo caracterizar as posturas induzidas por dois sistemas diferentes de cadeira-mesa e analisar seus efeitos na função pulmonar. Trata-se de estudo transversal, descritivo, do tipo sujeito único e intrasséries (A-B, B-A), com coleta em dias consecutivos. Participaram da pesquisa 15 voluntárias e foram utilizados dois sistemas cadeira-mesa: convencional (A) e experimental (B). A postura foi avaliada por meio de fotogrametria em cada um dos sistemas, com imagens analisadas por meio do programa AutoCAD® 2010. Posteriormente, foram calculados os ângulos articulares da postura média das participantes em cada sistema. Os dados posturais e respiratórios foram comparados considerando as diferentes posições adotadas. O sistema cadeira-mesa convencional promoveu dois diferentes padrões posturais: um deles apresentou ângulos articulares similares aos do sistema experimental, com resultados de espirometria semelhantes, e o outro padrão apresentou ângulos corporais de acordo com os padrões esperados com valores de espirometria significativamente inferiores em VEF1, VEF1/CVF e FEFmáx. O sistema experimental diferiu de valores de espirometria da postura ortostática relatados na literatura somente em FEFmáx, sugerindo similaridade de condição postural. Conclui-se que o mobiliário experimental melhorou a função respiratória na postura sentada em comparação com o mobiliário tradicional, podendo beneficiar pessoas em condições especiais, como gestantes, obesos e pessoas com doenças pulmonares crônicas.


RESUMEN Este estudio tuvo como objetivo caracterizar las posturas inducidas por dos sistemas diferentes de silla-mesa y analizar sus efectos sobre la función pulmonar. Se trata de un estudio transversal, descriptivo, de tipo de un solo sujeto e intraseries (A-B, B-A), con recolección en días consecutivos. Quince voluntarios participaron en el estudio, y se utilizaron dos sistemas de silla-mesa: convencional (A) y experimental (B). La evaluación postural se realizó mediante fotogrametría en cada uno de los sistemas, con imágenes analizadas por medio del programa AutoCAD® 2010. Posteriormente, se calcularon los ángulos de articulación de la postura media de las participantes en cada sistema. Los datos posturales y respiratorios se compararon considerando las diferentes posiciones adoptadas. El sistema de silla-mesa convencional promovió dos patrones posturales diferentes: uno presentó ángulos de articulación similares al sistema experimental, con resultados de espirometría similares, y el otro estándar presentó ángulos corporales de acuerdo con los patrones esperados con resultados de espirometría significativamente más bajos en VEF1, VEF1/CVF y FEFmax. El sistema experimental difería de los valores de espirometría de la postura ortostática informados en la literatura solo en FEFmax, lo que sugiere una similitud de la condición postural. Se concluyó que los muebles experimentales pueden mejorar la función respiratoria en la posición sentada cuando se comparaban con los muebles tradicionales, y pueden beneficiar a personas en condiciones especiales, como mujeres embarazadas, personas obesas y personas con enfermedades pulmonares crónicas.


ABSTRACT The objective of this study was to characterize the postures induced by two different chair-desk systems and analyze their effects on lung function. This was a cross-sectional, descriptive study of single subject with intra-series type analysis (A-B, B-A) during consecutive days of data collection. Fifteen volunteers participated using two chair-desk systems: conventional (A) and experimental (B). Postural evaluation was performed in both systems using photogrammetry. These images were analyzed using AutoCAD® 2010, estimating the average position of the joint angles of individuals in each system. These values were analyzed verifying the averages in each posture. Postural and respiratory data were compared by checking whether the different positions adopted by the participants resulted in changes in the spirometry values. Conventional chair-desk system promoted two different postural patterns, considering that one presented joint angles similar to experimental system, with similar spirometry results and the other presented body angles according to the reference of standards and spirometry results significantly lower in FEV1, FEV1/FVC and FEFmax. Experimental system differed from values of literature in standing posture only in FEFmax, suggesting similarity of postural situation. It was concluded that the experimental furniture proved a tool capable of benefiting respiratory function in sitting posture and may be an option to benefit people in special conditions such as pregnant women, obese individuals and people with chronic pulmonary diseases.


Sujets)
Humains , Femelle , Adolescent , Adulte , Mécanique respiratoire/physiologie , Position assise , Spirométrie , Phénomènes biomécaniques/physiologie , Études transversales , Ingénierie humaine
6.
In. Boggia de Izaguirre, José Gabriel; Hurtado Bredda, Francisco Javier; López Gómez, Alejandra; Malacrida Rodríguez, Leonel Sebastián; Angulo Nin, Martín; Seija Alves, Mariana; Luzardo Domenichelli, Leonella; Gadola Bergara, Liliana; Grignola Rial, Juan Carlos. Fisiopatología: mecanismos de las disfunciones orgánicas. Montevideo, BiblioMédica, 2 ed; c2019. p.403-415, ilus, graf.
Monographie Dans Espagnol | LILACS, UY-BNMED, BNUY | ID: biblio-1437050
7.
J. bras. pneumol ; 45(5): e20180311, 2019. tab, graf
Article Dans Portugais | LILACS | ID: biblio-1040280

Résumé

RESUMO Objetivo avaliar os diferentes componentes da resistência do sistema respiratório e a força muscular respiratória, bem como investigar a ocorrência de limitação de fluxo expiratório (LFE) de pacientes obesos mórbidos (OM) na posição sentada. Métodos a amostra foi composta de OM (IMC ≥ 40 kg/m2) e de indivíduos não obesos (NO) com IMC entre 18 e 30 kg/m2. O protocolo foi composto de: avaliação antropométrica e da função respiratória (espirometria, pressões inspiratória (PIM) e expiratória máximas (PEM) e oscilometria de impulso). Na comparação entre os grupos, foi utilizado o teste T para amostras não pareadas. As correlações foram avaliadas pelo teste de Pearson, e o nível de significância foi de 5%. Resultados Foram avaliados 50 OM (idade 40,0 ± 10,4 anos, 1,64 ± 0,09 m, 138,8 ± 33,6 kg e 50,7 ± 8,9 kg/m2), além de 30 NO (idade 37,6 ± 11,5 anos, 1,67 ± 0,09 m, 65,2 ± 10,3 kg e 23,2 ± 22 kg/m2). Os OM apresentaram maiores valores de resistência total, central, de vias aéreas, tecidual e periférica quando comparados aos NO. Nenhum paciente apresentou LFE. A circunferência abdominal se associou com variáveis espirométricas PIM e PEM. A relação cintura-quadril se correlacionou com variáveis de mecânica respiratória, além das espirométricas PIM e PEM. Conclusões pacientes com obesidade mórbida e sem padrão espirométrico obstrutivo apresentam aumento nas resistências total, de vias aéreas, periférica e tecidual do sistema respiratório quando comparados a não obesos. Esses indivíduos, entretanto, não apresentam limitação de fluxo expiratório e redução da força muscular respiratória.


ABSTRACT Objective To evaluate the different components of the resistance of the respiratory system, respiratory muscle strength and to investigate the occurrence of expiratory flow limitation (EFL) in patients with morbid obesity (MO) when seated. Methods The sample was composed of MO (BMI≥40 kg/m2) and non-obese individuals (NO) with a BMI between 18 and 30 kg/m2. The protocol consisted of the anthropometric assessment and the following measures of respiratory function: spirometry, maximal inspiratory and expiratory pressures (MIP and MEP, respectively) and impulse oscillometry. The group comparison was performed using T-test for unpaired samples. The correlations were evaluated by the Pearson test with a significance level of 5%. Results Fifty MO (age 40±10.4 years, 1.64±0.09 m, 138.8±33.6 kg and 50.7±8.9 kg/m2), and 30 NO (age 37.6±11.5 years, 1.67±0.09 m, 65.2±10.3 kg and 23.2±22 kg/m2) were evaluated. The MO showed higher values of total, peripheral, airways, tissue and central resistance when compared to the NO. No patient showed EFL. The waist circumference was associated with spirometric variables, MIP, and MEP. The waist-to-hip ratio was correlated to respiratory mechanics and spirometric variables, MIP, and MEP. Conclusion Morbidly obese patients with no obstructive spirometric pattern show increased total, airway, peripheral, and tissue respiratory system resistance when compared to nonobese. These individuals, however, do not present with expiratory flow limitation and reduced respiratory muscles strength.


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Obésité morbide/physiopathologie , Muscles respiratoires/physiopathologie , Mécanique respiratoire/physiologie , Force musculaire/physiologie , Valeurs de référence , Tests de la fonction respiratoire , Études cas-témoins , Anthropométrie , Études transversales , Statistique non paramétrique , Expiration/physiologie
8.
J. bras. pneumol ; 45(3): e20180058, 2019. tab, graf
Article Dans Anglais | LILACS | ID: biblio-990114

Résumé

ABSTRACT Objective: To investigate the effects of manual chest compression (MCC) on the expiratory flow bias during the positive end-expiratory pressure-zero end-expiratory pressure (PEEP-ZEEP) airway clearance maneuver applied in patients on mechanical ventilation. The flow bias, which influences pulmonary secretion removal, is evaluated by the ratio and difference between the peak expiratory flow (PEF) and the peak inspiratory flow (PIF). Methods: This was a crossover randomized study involving 10 patients. The PEEP-ZEEP maneuver was applied at four time points, one without MCC and the other three with MCC, which were performed by three different respiratory therapists. Respiratory mechanics data were obtained with a specific monitor. Results: The PEEP-ZEEP maneuver without MCC was enough to exceed the threshold that is considered necessary to move secretion toward the glottis (PEF − PIF difference > 33 L/min): a mean PEF − PIF difference of 49.1 ± 9.4 L/min was achieved. The mean PEF/PIF ratio achieved was 3.3 ± 0.7. Using MCC with PEEP-ZEEP increased the mean PEF − PIF difference by 6.7 ± 3.4 L/min. We found a moderate correlation between respiratory therapist hand grip strength and the flow bias generated with MCC. No adverse hemodynamic or respiratory effects were found. Conclusions: The PEEP-ZEEP maneuver, without MCC, resulted in an expiratory flow bias superior to that necessary to facilitate pulmonary secretion removal. Combining MCC with the PEEP-ZEEP maneuver increased the expiratory flow bias, which increases the potential of the maneuver to remove secretions.


RESUMO Objetivo: Avaliar os efeitos da compressão torácica manual (CTM) sobre o flow bias expiratório durante a manobra positive end-expiratory pressure-zero end-expiratory pressure (PEEP-ZEEP) para a remoção de secreção em pacientes sob ventilação mecânica invasiva. O flow bias, que influencia na remoção de secreção pulmonar, foi avaliado pela razão e diferença entre pico de fluxo expiratório (PFE) e pico de fluxo inspiratório (PFI). Métodos: Estudo cruzado e randomizado no qual participaram 10 pacientes. A manobra PEEP-ZEEP foi aplicada em quatro momentos, sendo um sem CTM e os outros três em associação com a CTM, que foram aplicadas por três fisioterapeutas distintos. Um monitor específico foi utilizado para o registro dos dados de mecânica respiratória. Resultados: A manobra PEEP-ZEEP sem a CTM foi suficiente para ultrapassar o limiar do flow bias expiratório (diferença PFE − PFI > 33 l/min), considerado necessário para deslocar a secreção em direção à glote; a média da diferença PFE − PFI encontrada foi de 49,1 ± 9,4 l/min. A média da razão PFE/PFI alcançada foi de 3,3 ± 0,7. A associação da CTM à PEEP-ZEEP aumentou a média da diferença PFE − PFI em 6,7 ± 3,4 l/min. Foi observada correlação moderada entre a força de preensão manual dos fisioterapeutas e o flow bias gerado durante a CTM. Não foram encontradas alterações hemodinâmicas ou respiratórias adversas ao longo do estudo. Conclusões: A manobra PEEP-ZEEP sem a CTM resultou em um flow bias expiratório superior ao considerado efetivo para auxiliar na remoção de secreção pulmonar. A associação com a CTM aumentou o flow bias expiratório, o que aumenta o potencial da manobra para remover secreções.


Sujets)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Sujet âgé , Jeune adulte , Ventilation artificielle/méthodes , Ventilation à pression positive/méthodes , Ventilation pulmonaire/physiologie , Paroi thoracique/physiopathologie , Poumon/physiologie , Valeurs de référence , Ventilation artificielle/effets indésirables , Facteurs temps , Modèles linéaires , Mécanique respiratoire/physiologie , Analyse de variance , Résultat thérapeutique , Études croisées , Sécrétions corporelles , Pression artérielle/physiologie
10.
Acta cir. bras ; 33(10): 879-888, Oct. 2018. graf
Article Dans Anglais | LILACS | ID: biblio-973464

Résumé

Abstract Purpose: To evaluate the vascular ventilatory response in different stages of lung development and to compare them to the neonates with congenital diaphragmatic hernia (CDH) in a rabbit model. Methods: New Zealand rabbits were divided into 8 groups (n=5): E25, E27, E30, and CDH. All groups were ventilated on a FlexiVent (Scireq, Montreal, QC, Canada), compounding the other 4 groups. The CDH surgery was performed at E25 and the harvest at E30. Dynamic compliance (CRS), dynamic elastance (ERS) and dynamic resistance (RRS) were measured every 4 min/24 min. Median wall thickness (MWT) and airspace were measured. ANOVA Bonferroni tests were used to perform statistical analysis. Significance was considered when p<0.05. Results: CRS was higher in E30 compared to all other groups (p<0.05). CRS and RRS of CDH and E27 were similar and were higher in E25 (p<0.05). MWT was decreased according to the gestational age, was increased in E27V and E30V (p<0.05) and decreased in CDHV (p<0.05), airspace was decreased in E25 and increased in all ventilated groups (p<0.05). Conclusions: The ventilation response of congenital diaphragmatic hernia is like the pseudoglandular stage of the lung development. These findings add information about the physiology of pulmonary ventilation in CDH.


Sujets)
Animaux , Lapins , Mécanique respiratoire/physiologie , Hernies diaphragmatiques congénitales/physiopathologie , Poumon/croissance et développement , Tests de la fonction respiratoire , Muscle diaphragme/chirurgie , Capacité pulmonaire totale , Résistance des voies aériennes , Modèles animaux de maladie humaine , Hernies diaphragmatiques congénitales/étiologie , Poumon/physiopathologie , Poumon/vascularisation , Animaux nouveau-nés
11.
J. pediatr. (Rio J.) ; 94(4): 419-424, July-Aug. 2018. tab
Article Dans Anglais | LILACS | ID: biblio-954632

Résumé

Abstract Objective: To compare impulse oscillometry system parameters of normal-weight children with overweight and obese children. Method: All participants were submitted to the evaluation of lung function (spirometry and impulse oscillometry) following the American Thoracic Society standards. The evaluation of respiratory mechanics was performed using the Jaeger™ MasterScreen™ Impulse Oscillometry System (Erich Jaeger, Germany), three tests were recorded, with acquisition for at least 20 seconds. Results: The study included 81 children (30 in the control group, 21 in the overweight group, and 30 the in obesity group), matched for age and sex. Regarding spirometry data, obesity group showed higher numerical values in relation to the control group; however, there were no significant differences among the three groups. For impulse oscillometry parameters, there was a difference between control group and obesity group for respiratory impedance (p = 0.036), resistance at 5 hertz (p = 0.026), resonant frequency (p = 0.029), and reactance area (p = 0.014). For the parameters expressed in percentage of predicted, there were differences in resistance at 5 hertz, resonant frequency, and reactance area between control group and obesity group. Conclusions: Obese children showed increased oscillometry parameters values representative of airway obstruction, compared to normal-weight children. Changes in some oscillometry parameters can already be observed in overweight school-aged children.


Resumo Objetivo: Comparar parâmetros do Sistema de Oscilometria de Impulso de crianças com peso normal com crianças com sobrepeso e obesas. Método: Todos os participantes foram submetidos à avaliação de mecanismos respiratórios utilizando o Sistema de Oscilometria de Impulso Jaeger™ (MasterScreen™ IOS, Erich Jaeger, Alemanha) seguindo as normas da Sociedade Torácica Americana. Todos os participantes foram submetidos a testes de espirometria e oscilometria (três testes foram registrados, com coleta de dados por pelo menos 20 segundos). Resultados: O estudo incluiu 81 crianças (30 no grupo de controle, 21 no grupo sobrepeso e 30 no grupo obesidade), pareadas por idade e sexo. No que diz respeito a dados de espirometria, o grupo obesidade mostrou valores numéricos mais elevados; contudo, não houve diferenças significativas entre os três grupos. No que diz respeito a parâmetros do Sistema de Oscilometria de Impulso, houve diferença entre o grupo de controle e o grupo obesidade em Z5 (p = 0,036), resistência 5 hertz (p = 0,026), frequência de ressonância (p = 0,029) e área de reatância (p = 0,014). Nos parâmetros expressos em percentual previsto, houve diferenças em resistência 5 hertz, frequência de ressonância e área de reatância entre o grupo de controle e grupo obesidade. Conclusões: Crianças obesas mostraram parâmetros de oscilometria aumentados representativos de obstrução das vias aéreas em comparação a crianças com peso normal. As alterações em alguns parâmetros oscilométricos já podem ser observadas em crianças com sobrepeso em idade escolar.


Sujets)
Humains , Mâle , Femelle , Enfant , Adolescent , Oscillométrie/méthodes , Mécanique respiratoire/physiologie , Résistance des voies aériennes/physiologie , Obésité/physiopathologie , Spirométrie , Études cas-témoins , Surpoids/physiopathologie
12.
Rev. bras. ter. intensiva ; 30(2): 208-218, abr.-jun. 2018. tab, graf
Article Dans Espagnol | LILACS | ID: biblio-959328

Résumé

RESUMEN La mecánica del sistema respiratorio depende de las características del pulmón, la caja torácica y su interacción. En pacientes con síndrome de distrés respiratorio agudo bajo ventilación mecánica el monitoreo de la presión meseta en la vía aérea es fundamental debido a su valor pronóstico y su capacidad de reflejar el estrés pulmonar. Sin embargo, su validez puede verse afectada por cambios en las características mecánicas de la caja torácica, y además, no otorga información para la correcta titulación de presión positiva al final de la espiración en función de restablecer el volumen pulmonar. La influencia que la caja torácica ejerce sobre la mecánica del sistema respiratorio en síndrome de distrés respiratorio agudo no ha sido completamente descripta y es probable que haya sido sobredimensionada pudiendo conducir a toma de decisiones erróneas. Ante la insuflación con presión positiva al final de la espiración, la carga impuesta por la caja torácica es despreciable. En condiciones dinámicas, desplazar esta estructura demanda un cambio de presión cuya magnitud se relaciona con sus características mecánicas, dicha carga se mantiene constante independientemente del volumen a partir del cual es insuflada. Por lo que cambios en la presión en la vía aérea reflejan modificaciones en las condiciones mecánicas del pulmón. El monitoreo avanzado podría reservarse para pacientes con incremento de la presión intra-abdominal en los que no pueda implementarse una estrategia de ventilación mecánica protectora. Las estimaciones de reclutamiento alveolar basadas en la mecánica del sistema respiratorio podrían ser reflejo del diferente comportamiento de la caja torácica a la insuflación y no verdadero reclutamiento alveolar.


ABSTRACT The respiratory system mechanics depend on the characteristics of the lung and chest wall and their interaction. In patients with acute respiratory distress syndrome under mechanical ventilation, the monitoring of airway plateau pressure is fundamental given its prognostic value and its capacity to assess pulmonary stress. However, its validity can be affected by changes in mechanical characteristics of the chest wall, and it provides no data to correctly titrate positive end-expiratory pressure by restoring lung volume. The chest wall effect on respiratory mechanics in acute respiratory distress syndrome has not been completely described, and it has likely been overestimated, which may lead to erroneous decision making. The load imposed by the chest wall is negligible when the respiratory system is insufflated with positive end-expiratory pressure. Under dynamic conditions, moving this structure demands a pressure change whose magnitude is related to its mechanical characteristics, and this load remains constant regardless of the volume from which it is insufflated. Thus, changes in airway pressure reflect changes in the lung mechanical conditions. Advanced monitoring could be reserved for patients with increased intra-abdominal pressure in whom a protective mechanical ventilation strategy cannot be implemented. The estimates of alveolar recruitment based on respiratory system mechanics could reflect differences in chest wall response to insufflation and not actual alveolar recruitment.


Sujets)
Humains , Ventilation artificielle/méthodes , /chirurgie , /thérapie , Mécanique respiratoire/physiologie , Pronostic , Alvéoles pulmonaires/métabolisme , /physiopathologie , Volume courant/physiologie , Ventilation à pression positive , Paroi thoracique/métabolisme , Monitorage physiologique/méthodes
13.
Rev. bras. cir. cardiovasc ; 32(2): 104-110, Mar.-Apr. 2017. tab, graf
Article Dans Anglais | LILACS | ID: biblio-843478

Résumé

Abstract INTRODUCTION: Enhanced respiratory muscle strength in patients with heart failure positively alters the clinical trajectory of heart failure. In an experimental model, respiratory muscle training in rats with heart failure has been shown to improve cardiopulmonary function through mechanisms yet to be entirely elucidated. OBJECTIVE: The present report aimed to evaluate the respiratory muscle training effects in diaphragm citrate synthase activity and hemodynamic function in rats with heart failure. METHODS: Wistar rats were divided into four experimental groups: sedentary sham (Sed-Sham, n=8), trained sham (RMT-Sham, n=8), sedentary heart failure (Sed-HF, n=7) and trained heart failure (RMT-HF, n=7). The animals were submitted to a RMT protocol performed 30 minutes a day, 5 days/week, for 6 weeks. RESULTS: In rats with heart failure, respiratory muscle training decreased pulmonary congestion and right ventricular hypertrophy. Deleterious alterations in left ventricular pressures, as well as left ventricular contractility and relaxation, were assuaged by respiratory muscle training in heart failure rats. Citrate synthase activity, which was significantly reduced in heart failure rats, was preserved by respiratory muscle training. Additionally, a negative correlation was found between citrate synthase and left ventricular end diastolic pressure and positive correlation was found between citrate synthase and left ventricular systolic pressure. CONCLUSION: Respiratory muscle training produces beneficial adaptations in the diaphragmatic musculature, which is linked to improvements in left ventricular hemodynamics and blood pressure in heart failure rats. The RMT-induced improvements in cardiac architecture and the oxidative capacity of the diaphragm may improve the clinical trajectory of patients with heart failure.


Sujets)
Animaux , Mâle , Exercices respiratoires/méthodes , Muscle diaphragme/enzymologie , Citrate (si)-synthase/métabolisme , Défaillance cardiaque/enzymologie , Défaillance cardiaque/physiopathologie , Hémodynamique/physiologie , Pression sanguine/physiologie , Muscle diaphragme/physiologie , Mécanique respiratoire/physiologie , Rat Wistar , Modèles animaux , Infarctus du myocarde/physiopathologie
14.
Rev. bras. ter. intensiva ; 29(1): 77-86, jan.-mar. 2017. tab, graf
Article Dans Portugais | LILACS | ID: biblio-844281

Résumé

RESUMO Objetivo: Revisar a literatura em relação à utilização da ventilação variável e aos principais desfechos relacionados à sua utilização. Métodos: Busca, seleção e análise de todos os artigos originais sobre ventilação variável, sem restrição quanto ao período de publicação e ao idioma, nas bases de dados eletrônicas LILACS, MEDLINE® e PubMed, encontrados por meio de busca pelos termos "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Resultados: Foram selecionados 36 artigos na busca. Após a análise, 24 artigos eram originais; destes 21 experimentais e 3 clínicos. Conclusão: Diversos estudos experimentais evidenciaram os efeitos benéficos de variadas estratégias ventilatórias variáveis sobre a função pulmonar em diferentes modelos de lesão pulmonar e em pulmões saudáveis. A ventilação variável parece ser uma estratégia viável para o aprimoramento da troca gasosa e mecânica respiratória, assim como para prevenção de lesão pulmonar associada à ventilação mecânica. Entretanto, estudos clínicos são necessários para investigar o potencial destas estratégias ventilatórias variáveis na melhora clínica dos pacientes submetidos à ventilação mecânica.


ABSTRACT Objective: To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Methods: Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Results: A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Conclusion: Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation.


Sujets)
Humains , Animaux , Ventilation artificielle/méthodes , Mécanique respiratoire/physiologie , Maladies pulmonaires/thérapie , Ventilation artificielle/effets indésirables , Tests de la fonction respiratoire , Échanges gazeux pulmonaires , Lésion pulmonaire/prévention et contrôle
15.
Rev. bras. anestesiol ; 67(1): 92-94, Jan.-Feb. 2017.
Article Dans Anglais | LILACS | ID: biblio-843364

Résumé

Abstract Background and objectives: Tracheal stenosis is a rare but a life-threatening condition and anesthesia of a patient with tracheal stenosis is challenging for anesthesiologists. Maintaining stable hemodynamics and ventilation parameters are important issues in neuroanesthesia. Any increase in airway peak pressure and ETCO2 will result in increase in intracranial pressure which must be avoided during craniotomies. Tracheal stenosis could be a reason for increased airway pressure. Case report: We described a patient undergoing craniotomy with tracheal stenosis. Conclusion: Detailed preparation for intubation, to stabilize airway dynamics and to make the right decision for the surgery were important points. To maintain of a good balance between cerebral dynamics and airway dynamics were the pearls of this case.


Resumo Justificativa e objetivos: Estenose traqueal é uma doença rara, mas de risco, e a anestesia em paciente com estenose traqueal é um desafio para os anestesiologistas. Manter os parâmetros hemodinâmicos estáveis e a ventilação são questões importantes em neuroanestesia. Qualquer aumento da pressão de pico das vias aéreas e da ETCO2 resultará em aumento da pressão intracraniana, o que deve ser evitado durante craniotomias. A estenose traqueal pode ser uma razão para o aumento da pressão das vias aéreas. Relato de caso: Descrevemos o caso de um paciente submetido à craniotomia com estenose traqueal. Conclusão: A preparação detalhada para a intubação, estabilizar a dinâmica das vias aéreas e tomar a decisão certa para a cirurgia foram pontos importantes. Manter um bom equilíbrio entre a dinâmica cerebral e a dinâmica das vias aéreas foi a pérola deste caso.


Sujets)
Humains , Femelle , Sténose trachéale/complications , Pression intracrânienne/physiologie , Craniotomie , Sténose trachéale/physiopathologie , Tumeurs sus-tentorielles/chirurgie , Tumeurs sus-tentorielles/physiopathologie , Mécanique respiratoire/physiologie , Surveillance peropératoire/méthodes , Adulte d'âge moyen
16.
Rev. bras. anestesiol ; 67(1): 28-34, Jan.-Feb. 2017. tab, graf
Article Dans Anglais | LILACS | ID: biblio-843354

Résumé

Abstract Objective: General anesthesia causes reduction of functional residual capacity. And this decrease can lead to atelectasis and intrapulmonary shunting in the lung. In this study we want to evaluate the effects of 5 and 10 cmH2O PEEP levels on gas exchange, hemodynamic, respiratory mechanics and systemic stress response in laparoscopic cholecystectomy. Methods: American Society of Anesthesiologist I-II physical status 43 patients scheduled for laparoscopic cholecystectomy were randomly selected to receive external PEEP of 5 cmH2O (PEEP 5 group) or 10 cmH2O PEEP (PEEP 10 group) during pneumoperitoneum. Basal hemodynamic parameters were recorded, and arterial blood gases (ABG) and blood sampling were done for cortisol, insulin and glucose level estimations to assess the systemic stress response before induction of anesthesia. Thirty minutes after the pneumoperitoneum, the respiratory and hemodynamic parameters were recorded again and ABG and sampling for cortisol, insulin, and glucose levels were repeated. Lastly hemodynamic parameters were recorded; ABG analysis and sampling for stress response levels were taken after 60 minutes from extubation. Results: There were no statistical differences between the two groups about hemodynamic and respiratory parameters except mean airway pressure (P mean). P mean, compliance and PaO2; pH values were higher in 'PEEP 10 group'. Also, PaCO2 values were lower in 'PEEP 10 group'. No differences were observed between insulin and lactic acid levels in the two groups. But postoperative cortisol level was significantly lower in 'PEEP 10 group'. Conclusion: Ventilation with 10 cmH2O PEEP increases compliance and oxygenation, does not cause hemodynamic and respiratory complications and reduces the postoperative stress response.


Resumo Objetivo: A anestesia geral causa a redução da capacidade residual funcional e essa diminuição pode levar à atelectasia pulmonar e ao shunt intrapulmonar. Neste estudo pretendemos avaliar os efeitos de níveis de 5 e 10 cmH2O de pressão expiratória final positiva (PEEP) sobre as trocas gasosas, a hemodinâmica, a mecânica respiratória e a resposta ao estresse sistêmico em colecistectomia laparoscópica. Método: Foram selecionados aleatoriamente 43 pacientes, estado físico ASA I-II, agendados para colecistectomia laparoscópica, para receber PEEP a 5 cmH2O (grupo PEEP-5) ou PEEP de 10 cmH2O (grupo PEEP-10) durante o pneumoperitônio. Os parâmetros hemodinâmicos foram registrados, gasometria arterial e coleta de sangue foram feitas para estimativa dos níveis de cortisol, insulina e glicose para avaliar a resposta ao estresse sistêmico antes da indução anestésica. Trinta minutos após o pneumoperitônio, os parâmetros hemodinâmicos e respiratórios foram registrados novamente e gasometria e amostragem para os níveis de cortisol, insulina e glicose foram repetidos. E os últimos parâmetros hemodinâmicos foram registrados, análise e amostragem de gasometria para os níveis de resposta ao estresse foram feitas após 60 minutos da extubação. Resultados: Não houve diferença estatística entre dois grupos quanto aos parâmetros hemodinâmicos e respiratórios, exceto pressão média das vias aéreas (Pmédia). Os valores de Pmédia, complacência, PaO2 e do pH foram maiores no grupo PEEP-10. Também os valores de PaCO2 foram menores no grupo PEEP-10. Não foram observadas quaisquer diferenças entre os níveis de insulina e de ácido láctico nos dois grupos. Porém, o nível de cortisol no pós-operatório foi significativamente menor no grupo PEEP-10. Conclusão: Ventilação com PEEP de 10 cmH2O aumenta a complacência e a oxigenação, não causa hemodinâmica e complicações respiratórias e reduz a resposta ao estresse no pós-operatório.


Sujets)
Humains , Mâle , Femelle , Adolescent , Adulte , Sujet âgé , Jeune adulte , Stress physiologique/physiologie , Mécanique respiratoire/physiologie , Cholécystectomie laparoscopique , Hémodynamique/physiologie , Pression sanguine/physiologie , Études prospectives , Ventilation à pression positive , Électrocardiographie , Rythme cardiaque/physiologie , Adulte d'âge moyen
17.
Arq. neuropsiquiatr ; 75(1): 9-14, Jan. 2017. tab, graf
Article Dans Anglais | LILACS | ID: biblio-838848

Résumé

ABSTRACT Objective: The nasal cycle, which is present in a significant number of people, is an ultradian side-to-side rhythm of nasal engorgement associated with cyclic autonomic activity. We studied the nasal cycle during REM/non-REM sleep stages and examined the potentially confounding influence of body position on lateralized nasal airflow. Methods: Left- and right-side nasal airflow was measured in six subjects during an eight-hour sleep period using nasal thermistors. Polysomnography was performed. Simultaneously, body positions were monitored using a video camera in conjunction with infrared lighting. Results: Significantly greater airflow occurred through the right nasal chamber (relative to the left) during periods of REM sleep than during periods of non-REM sleep (p<0.001). Both body position (p < 0.001) and sleep stage (p < 0.001) influenced nasal airflow lateralization. Conclusions: This study demonstrates that the lateralization of nasal airflow and sleep stage are related. Some types of asymmetrical somatosensory stimulation can alter this relationship.


RESUMO Objetivo: O ciclo nasal é um ritmo ultradiano de lado a lado de ingurgitamento associado com o ciclo da atividade autônoma. O objetivo deste estudo foi abordar a questão assim como a relação presente entre o ciclo nasal e os estágios de sono REM/não-REM. Também analisamos a confusão potencial da influência da posição corporal no fluxo de ar nasal. Métodos: Mensuramos o ciclo nasal em seis sujeitos durante um sono de oito horas usando um termistor nasal. Foi realizada uma polissonografia. Simultaneamente, nós monitoramos a posição corporal usando uma câmera de vídeo juntamente com luzes infravermelhas. Resultados: Um fluxo de ar maior ocorreu através da cavidade nasal direita durante as fases de sono REM do que nos períodos de sono não-REM (p < 0,001). Assim como a posição corporal [F(2.2340) = 86,99, p < 0,001] e o estágio de sono [F(1.2340) = 234.82, p < 0,001] influenciaram a lateralização do fluxo de ar nasal. Conclusões: Este estudo evidencia que a lateralização do fluxo de ar nasal e o estágio do sono estão relacionados. Alguns tipos de estimulação somatosensitiva assimétrica podem alterar esta relação.


Sujets)
Humains , Mâle , Femelle , Adulte , Posture/physiologie , Phases du sommeil/physiologie , Rythme ultradien/physiologie , Fosse nasale/physiologie , Mécanique respiratoire/physiologie , Polysomnographie
18.
Braz. j. phys. ther. (Impr.) ; 20(4): 336-344, July-Aug. 2016. tab, graf
Article Dans Anglais | LILACS | ID: lil-792715

Résumé

ABSTRACT Background The effects of non-invasive ventilation (NIV) on the breathing pattern and thoracoabdominal motion of patients with amyotrophic lateral sclerosis (ALS) are unknown. Objectives 1) To analyze the influence of NIV on chest wall volumes and motion assessed by optoelectronic plethysmography in ALS patients and 2) to compare these parameters in the supine and sitting positions to those of healthy individuals (without NIV). Method Nine ALS patients were evaluated in the supine position using NIV. In addition, the ALS patients and nine healthy individuals were evaluated in both sitting and supine positions. Statistical analysis was performed using the paired Student t-test or Wilcoxon test and the Student t-test for independent samples or Mann-Whitney U test. Results Chest wall volume increased significantly with NIV, mean volume=0.43 (SD=0.16)L versus 0.57 (SD=0.19)L (p=0.04). No significant changes were observed for the pulmonary rib cage, abdominal rib cage, or abdominal contribution. The index of the shortening velocity of the diaphragmatic muscle, mean=0.15 (SD=0.05)L/s versus 0.21 (SD=0.05)L/s (p<0.01), and abdominal muscles, mean=0.09 (SD=0.02)L/s versus 0.14 (SD=0.06)L/s (p<0.01), increased during NIV. Comparisons between the supine and sitting positions showed similar changes in chest wall motion in both groups. However, the ALS patients presented a significantly lower contribution of the abdomen in the supine position compared with the controls, mean=56 (SD=13) versus 69 (SD=10) (p=0.02). Conclusions NIV improved chest wall volumes without changing the contribution of the chest wall compartment in ALS patients. In the supine position, ALS patients had a lower contribution of the abdomen, which may indicate early diaphragmatic dysfunction.


Sujets)
Humains , Posture/physiologie , Mécanique respiratoire/physiologie , Paroi thoracique/physiologie , Ventilation non effractive , Sclérose latérale amyotrophique/physiopathologie , Pléthysmographie , Phénomènes biomécaniques
19.
Rev. bras. ter. intensiva ; 28(1): 27-32, jan.-mar. 2016. tab, graf
Article Dans Portugais | LILACS | ID: lil-779997

Résumé

RESUMO Objetivo: Determinar a eficácia da manobra de hiperinsuflação pulmonar com o ventilador mecânico, em comparação à aspiração traqueal isolada, para remover secreções, normalizar a hemodinâmica e melhorar a mecânica pulmonar em pacientes em ventilação mecânica. Métodos: Ensaio clínico randomizado cruzado incluindo pacientes em ventilação mecânica por mais de 48 horas internados na unidade de terapia intensiva. Os pacientes foram randomizados para receber a aspiração traqueal isolada (Grupo Controle) e hiperinsuflação pulmonar por meio do ventilador mecânico (Grupo HVM). Mensuraram-se parâmetros hemodinâmicos e de mecânica respiratória, assim como a quantidade de secreção aspirada. Resultados: Foram incluídos 50 pacientes. A média de idade dos pacientes foi de 44,7 ± 21,6 anos, sendo 31 do sexo masculino. O Grupo HVM apresentou maior quantidade de secreção aspirada (3,9g versus 6,4g; p = 0,0001), variação na média da complacência dinâmica (-1,3 ± 2,3 versus -2,9 ± 2,3; p = 0,008), volume corrente expirado (-0,7 ± 0,0 versus -54,1 ± 38,8; p = 0,0001) e diminuição significativa da pressão inspiratória de pico (0,2 ± 0,1 versus 2,5 ± 0,1; p = 0,001), em comparação com o Grupo Controle. Conclusão: Na amostra estudada, a técnica de HVM apresentou maior quantidade de secreção aspirada, aumento significativo da complacência dinâmica e volume corrente expirado, além de diminuição significativa da pressão de pico inspiratória.


ABSTRACT Objective: To determine the efficacy of lung hyperinflation maneuvers via a mechanical ventilator compared to isolated tracheal aspiration for removing secretions, normalizing hemodynamics and improving lung mechanics in patients on mechanical ventilation. Methods: This was a randomized crossover clinical trial including patients admitted to the intensive care unit and on mechanical ventilation for more than 48 hours. Patients were randomized to receive either isolated tracheal aspiration (Control Group) or lung hyperinflation by mechanical ventilator (MVH Group). Hemodynamic and mechanical respiratory parameters were measured along with the amount of aspirated secretions. Results: A total of 50 patients were included. The mean age of the patients was 44.7 ± 21.6 years, and 31 were male. Compared to the Control Group, the MVH Group showed greater aspirated secretion amount (3.9g versus 6.4g, p = 0.0001), variation in mean dynamic compliance (-1.3 ± 2.3 versus -2.9 ± 2.3; p = 0.008), and expired tidal volume (-0.7 ± 0.0 versus -54.1 ± 38.8, p = 0.0001) as well as a significant decrease in peak inspiratory pressure (0.2 ± 0.1 versus 2.5 ± 0.1; p = 0.001). Conclusion: In the studied sample, the MVH technique led to a greater amount of aspirated secretions, significant increases in dynamic compliance and expired tidal volume and a significant reduction in peak inspiratory pressure.


Sujets)
Humains , Mâle , Femelle , Adulte , Sujet âgé , Jeune adulte , Ventilation artificielle/méthodes , Trachée/métabolisme , Mécanique respiratoire/physiologie , Poumon/métabolisme , Volume courant , Études croisées , Inhalation bronchique/métabolisme , Hémodynamique/physiologie , Unités de soins intensifs , Adulte d'âge moyen
20.
Braz. j. med. biol. res ; 49(9): e5182, 2016. tab, graf
Article Dans Anglais | LILACS | ID: lil-788942

Résumé

We used a computational fluid dynamics (CFD) model to study the inspiratory airflow profiles of patients with anterior nasal cavity stenosis who underwent curative surgery, by comparing pre- and postoperative airflow characteristics. Twenty patients with severe anterior nasal cavity stenosis, including one case of bilateral stenosis, underwent computed tomography (CT) scans for CFD modelling. The pre- and postoperative airflow characteristics of the nasal cavity were simulated and analyzed. The narrowest area of the nasal cavity in all 20 patients was located within the nasal valve area, and the mean cross-sectional area increased from 0.39 cm2 preoperative to 0.78 cm2 postoperative (P<0.01). Meanwhile, the mean airflow velocity in the nasal valve area decreased from 6.19 m/s to 2.88 m/s (P<0.01). Surgical restoration of the nasal symmetry in the bilateral nasal cavity reduced nasal resistance in the narrow sides from 0.24 Pa.s/mL to 0.11 Pa.s/mL (P<0.01). Numerical simulation of the nasal cavity in patients with anterior nasal cavity stenosis revealed structural changes and the resultant patterns of nasal airflow. Surgery achieved balanced bilateral nasal ventilation and decreased nasal resistance in the narrow region of the nasal cavity. The correction of nasal valve stenosis is not only indispensable for reducing nasal resistance, but also the key to obtain satisfactory curative effect.


Sujets)
Humains , Mâle , Femelle , Fosse nasale/chirurgie , Obstruction nasale/chirurgie , Mécanique respiratoire/physiologie , Simulation numérique , Sténose pathologique/imagerie diagnostique , Sténose pathologique/physiopathologie , Sténose pathologique/chirurgie , Hydrodynamique , Imagerie tridimensionnelle , Fosse nasale/imagerie diagnostique , Fosse nasale/physiopathologie , Obstruction nasale/imagerie diagnostique , Obstruction nasale/physiopathologie