Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
Ajouter des filtres








Gamme d'année
1.
J. appl. oral sci ; 24(2): 136-141, Mar.-Apr. 2016. tab, graf
Article Dans Anglais | LILACS | ID: lil-779900

Résumé

ABSTRACT The use of light sources in the bleaching process reduces the time required and promotes satisfactory results. However, these light sources can cause an increase in the pulp temperature. Objective The purpose of the present study was to measure the increase in intrapulpal temperature induced by different light-activated bleaching procedures with and without the use of a bleaching gel. Material and Methods A human maxillary central incisor was sectioned 2 mm below the cementoenamel junction. A K-type thermocouple probe was introduced into the pulp chamber. A 35% hydrogen peroxide bleaching gel was applied to the vestibular tooth surface. The light units used were a conventional halogen, a hybrid light (only LED and LED/Laser), a high intensity LED, and a green LED light. Temperature increase values were compared by two-way ANOVA and Tukey´s tests (p<0.05). Results There were statistically significant differences in temperature increases between the different light sources used and between the same light sources with and without the use of a bleaching gel. The presence of a bleaching gel generated an increase in intra-pulpal temperature in groups activated with halogen light, hybrid light, and high intensity LED. Compared to the other light sources, the conventional halogen lamp applied over the bleaching gel induced a significant increase in temperature (3.83±0.41°C). The green LED unit with and without gel application did not produce any significant intrapulpal temperature variations. Conclusion In the present study, the conventional halogen lamp caused the highest increase in intrapulpal temperature, and the green LED caused the least. There was an increase in temperature with all lights tested and the maximum temperature remained below the critical level (5.5°C). The addition of a bleaching gel led to a higher increase in intrapulpal temperatures.


Sujets)
Humains , Pulpe dentaire/effets des radiations , Lasers à semiconducteur , Lumière , Blanchiment dentaire/méthodes , Analyse de variance , Pulpe dentaire/effets des médicaments et des substances chimiques , Gels , Température élevée , Peroxyde d'hydrogène/effets des radiations , Oxydants/effets des radiations , Valeurs de référence , Reproductibilité des résultats , Blanchiment dentaire/instrumentation
2.
J. appl. oral sci ; 17(5): 436-439, Sept.-Oct. 2009. ilus, tab
Article Dans Anglais | LILACS | ID: lil-531393

Résumé

OBJECTIVES: The aim of this study was to evaluate the intrapulpal temperature variation after bleaching treatment with 35 percent hydrogen peroxide using different sources of activation. MATERIAL AND METHODS: Twenty-four human teeth were sectioned in the mesiodistal direction providing 48 specimens, and were divided into 4 groups (n=12): (G1) Control - Bleaching gel without light activation, (G2) Bleaching gel + halogen light, (G3) Bleaching gel + LED, (G4) Bleaching gel + Nd:YAG Laser. The temperatures were recorded using a digital thermometer at 4 time points: before bleaching gel application, 1 min after bleaching gel application, during activation of the bleaching gel, and after the bleaching agent turned from a dark-red into a clear gel. Data were analyzed statistically by the Dunnet's test, ANOVA and Tukey's test (a=0.05). RESULTS: The mean intrapulpal temperature values (ºC) in the groups were: G1: 0.617 ± 0.41; G2: 1.800 ± 0.68; G3: 0.975 ± 0.51; and G4: 4.325 ± 1.09. The mean maximum temperature variation (MTV) values were: 1.5ºC (G1), 2.9ºC (G2), 1.7ºC (G3) and 6.9ºC (G4). When comparing the experimental groups to the control group, G3 was not statistically different from G1 (p>0.05), but G2 and G4 presented significantly higher (p<0.05) intrapulpal temperatures and MTV. The three experimental groups differed significantly (p<0.05) from each other. CONCLUSIONS: The Nd:YAG laser was the activation method that presented the highest values of intrapulpal temperature variation when compared with LED and halogen light. The group activated by LED light presented the lowest values of temperature variation, which were similar to that of the control group.


Sujets)
Humains , Température du corps/effets des médicaments et des substances chimiques , Pulpe dentaire/effets des médicaments et des substances chimiques , Peroxyde d'hydrogène/usage thérapeutique , Lumière , Oxydants/usage thérapeutique , Blanchiment dentaire/méthodes , Gels , Peroxyde d'hydrogène/administration et posologie , Peroxyde d'hydrogène/effets des radiations , Lasers à solide/usage thérapeutique , Éclairage/instrumentation , Test de matériaux , Oxydants/administration et posologie , Oxydants/effets des radiations , Thermomètres , Facteurs temps
3.
J. appl. oral sci ; 16(5): 355-359, Sept.-Oct. 2008. ilus, tab
Article Dans Anglais | LILACS | ID: lil-495141

Résumé

This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35 percent hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1 percent significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser ...


Sujets)
Humains , Température du corps , Pulpe dentaire/physiologie , Lumière/effets indésirables , Blanchiment dentaire/effets indésirables , Lampes à photopolymériser dentaires , Halogènes , Peroxyde d'hydrogène/effets des radiations , Incisive , Lasers , Oxydants/effets des radiations , Semiconducteurs
SÉLECTION CITATIONS
Détails de la recherche