Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 447
Filtre
1.
China Journal of Chinese Materia Medica ; (24): 6396-6402, 2023.
Article Dans Chinois | WPRIM | ID: wpr-1008838

Résumé

A quantitative proton nuclear magnetic resonance(qHNMR) method was established to determine the glucose content in commercially available Massa Medicata Fermentata(MMF) products and explore the variations of glucose content in MMF products during processing. The qHNMR spectrum of MMF in deuterium oxide was obtained with 2,2,3,3-d_4-3-(trimethylsilyl) propionate sodium salt as the internal standard substance. With the doublet peaks of terminal hydrogen of glucose with chemical shift at δ 4.65 and δ 5.24 as quantitative peaks, the content of glucose in MMF samples was determined. The glucose content showed a good linear relationship within the range of 0.10-6.44 mg·mL~(-1). The relative standard deviations(RSDs) of precision, stability, repeatability, and recovery for determination were all less than 2.3%. The glucose content varied in different commercially available MMF samples, which were associated with the different fermentation days, wheat bran-to-flour ratios, and processing methods. The glucose content in MMF first increased and then decreased over the fermentation time. Compared with the MMF products fermented with wheat bran or flour alone, the products fermented with both wheat bran and flour had increased glucose. The glucose content of bran-fried MMF was slightly lower than that of raw MMF, while the glucose content in charred MMF was extremely low. In conclusion, the qHNMR method established in this study is simple, fast, and accurate, serving as a new method for determining the glucose content in MMF. Furthermore, this study clarifies the variations of glucose content in MMF during processing, which can not only indicate the processing degree but also provide a scientific basis for revealing the fermentation mechanism and improving the quality control of MMF.


Sujets)
Protons , Médicaments issus de plantes chinoises/composition chimique , Fibre alimentaire , Spectroscopie par résonance magnétique
2.
Neuroscience Bulletin ; (6): 1157-1172, 2023.
Article Dans Anglais | WPRIM | ID: wpr-982467

Résumé

Hv1 is the only voltage-gated proton-selective channel in mammalian cells. It contains a conserved voltage-sensor domain, shared by a large class of voltage-gated ion channels, but lacks a pore domain. Its primary role is to extrude protons from the cytoplasm upon pH reduction and membrane depolarization. The best-known function of Hv1 is the regulation of cytosolic pH and the nicotinamide adenine dinucleotide phosphate oxidase-dependent production of reactive oxygen species. Accumulating evidence indicates that Hv1 is expressed in nervous systems, in addition to immune cells and others. Here, we summarize the molecular properties, distribution, and physiological functions of Hv1 in the peripheral and central nervous systems. We describe the recently discovered functions of Hv1 in various neurological diseases, including brain or spinal cord injury, ischemic stroke, demyelinating diseases, and pain. We also summarize the current advances in the discovery and application of Hv1-targeted small molecules in neurological diseases. Finally, we discuss the current limitations of our understanding of Hv1 and suggest future research directions.


Sujets)
Animaux , Protons , Canaux ioniques/métabolisme , Espèces réactives de l'oxygène/métabolisme , Encéphale/métabolisme , NADPH oxidase , Mammifères/métabolisme
3.
Neuroscience Bulletin ; (6): 845-862, 2023.
Article Dans Anglais | WPRIM | ID: wpr-982425

Résumé

Adenosine triphosphate (ATP) is well-known as a universal source of energy in living cells. Less known is that this molecule has a variety of important signaling functions: it activates a variety of specific metabotropic (P2Y) and ionotropic (P2X) receptors in neuronal and non-neuronal cell membranes. So, a wide variety of signaling functions well fits the ubiquitous presence of ATP in the tissues. Even more ubiquitous are protons. Apart from the unspecific interaction of protons with any protein, many physiological processes are affected by protons acting on specific ionotropic receptors-acid-sensing ion channels (ASICs). Both protons (acidification) and ATP are locally elevated in various pathological states. Using these fundamentally important molecules as agonists, ASICs and P2X receptors signal a variety of major brain pathologies. Here we briefly outline the physiological roles of ASICs and P2X receptors, focusing on the brain pathologies involving these receptors.


Sujets)
Humains , Canaux ioniques sensibles à l'acidité , Protons , Neurones , Encéphalopathies , Adénosine triphosphate/physiologie
4.
Chinese Journal of Medical Instrumentation ; (6): 370-376, 2023.
Article Dans Chinois | WPRIM | ID: wpr-982248

Résumé

The proton treatment control system is the supporting software of the proton therapy device, which specifically coordinates and controls the status and work of each subsystem. In this study, the software architecture and hardware implementation of the proton treatment control system was developed and built a foundation for the overall debugging. Using C# programming language and WPF programming techniques, TCP network communication protocol specified by the proton treatment technical document and MVVM pattern in Windows system, the logic design and implementation of each level were studied. Meanwhile, the communication interface between the subsystems under TCP communication protocol was agreed. The logic design and research of the setup field and treatment field were carried out. And the User Interface was designed and developed using the above technology. The program realizes the communication and interaction between the proton treatment control system and each subsystem, so as to control and monitor the whole treatment process. The proton treatment control system provides a software basis for the remote overall debugging and on-line monitor and control of proton treatment device.


Sujets)
Protons , Interface utilisateur , Logiciel , Ordinateurs , Logique
5.
Prensa méd. argent ; 106(3): 186-190, 20200000. graf, tab
Article Dans Anglais | LILACS, BINACIS | ID: biblio-1369103

Résumé

In this research, the electronic stopping power was calculated using Bethe and Bragg rule equations for the protons in Human tissues (Bone, Muscle (skeletal) and Adipose tissue) all within energy range (0.01-1000) MeV. The equations were programmed using MATLAB 2017, the calculations were compared with the experimental data of the SRIM2013program and PSTAR code, this comparison showed a good agreement with experimental data


Sujets)
Humains , Protons , Rayonnement ionisant , Temps , Puissance , Analyse de structure latente
6.
Chinese Journal of Medical Instrumentation ; (6): 185-188, 2020.
Article Dans Chinois | WPRIM | ID: wpr-942724

Résumé

As a new type of magnetic resonance imaging method, amide proton transfer (APT) imaging can detect the chemical exchange characteristics of free proprotein, peptide amide proton and water proton by water signal changes, reflecting the changes of protein and pH in tissues. In recent years, clinical research on brain tumors, multiple sclerosis, hepatic encephalopathy and cervical cancer have been carried out. It is a radiation-free and non-invasive new magnetic resonance molecular imaging technology. This study briefly reviews the principle of APT technology and its clinical application, and prospects its application prospects in children's abdominal tumors.


Sujets)
Enfant , Humains , Abdomen/anatomopathologie , Amides , Imagerie par résonance magnétique , Tumeurs/imagerie diagnostique , Protons
7.
Chinese Journal of Medical Instrumentation ; (6): 476-480, 2020.
Article Dans Chinois | WPRIM | ID: wpr-880394

Résumé

Compared with conventional high energy X-ray radiotherapy, proton/carbon ion has obvious advantages because of its Bragg peak dose distribution. However, proton heavy ion facility has complex structure, high energy and various radiation types due to various nuclear reaction processes, the radiation protection safety brought by the operation of facilities has gradually attracted attention. Taking the proton/carbon ion radiotherapy facility of Shanghai Proton and Heavy Ion Center as an example, the author mainly analyzed the operation principle of proton/carbon ion treatment facility, the basis of radiation protection, analysis of key radiation source points, etc., so as to provide theoretical support and experience for radiation protection.


Sujets)
Chine , Radiothérapie par ions lourds , Ions lourds , Exposition professionnelle/prévention et contrôle , Protons , Radioprotection , Radiothérapie
8.
Korean Journal of Radiology ; : 641-648, 2019.
Article Dans Anglais | WPRIM | ID: wpr-741436

Résumé

OBJECTIVE: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. MATERIALS AND METHODS: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1–1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were re-scanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. RESULTS: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776–0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. CONCLUSION: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.


Sujets)
Adulte , Animaux , Femelle , Humains , Mâle , Contusions , Diagnostic , Capra , Ligaments , Imagerie par résonance magnétique , Modèles animaux , Protons , Sensibilité et spécificité , Rachis , Larmes , Poids et mesures
9.
Korean Journal of Radiology ; : 487-497, 2019.
Article Dans Anglais | WPRIM | ID: wpr-741415

Résumé

OBJECTIVE: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries. MATERIALS AND METHODS: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF(t))-5.5, 6.8, and 9.7 for T1WI and 3.2, 4.0, and 5.8 for PD-to achieve reduced scanning times in comparison with the original imaging sequence (SENSE T1WI, AF(t) 3.5; SENSE PD, AF(t) 2.0) using the 3-tesla system. Two neuroradiologists measured signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and used visual scoring systems to assess image quality. Acceptable imaging was defined as a visual score ≥ 2. Repeated measures analysis of variance and Cochran's Q test were performed. RESULTS: CS yielded better image quality and vessel delineation than SENSE in T1WI with AF(t) of 5.5, 6.8, and 9.7, and in PD with AF(t) of 5.8 (p 0.05). SNR and CNR in CS were higher than they were in SENSE, but lower than they were in the original images (p < 0.05). CS yielded higher proportions of acceptable imaging than SENSE (CS T1WI with AF(t) of 6.8 and PD with AF(t) of 5.8; p < 0.0167). CONCLUSION: CS is superior to SENSE, and may be a reliable acceleration method for vessel HR-MRI using AF(t) of 5.5 for T1WI, and 3.2 and 4.0 for PD.


Sujets)
Accélération , Artères , Volontaires sains , Imagerie par résonance magnétique , Méthodes , Protons , Rapport signal-bruit
10.
Investigative Magnetic Resonance Imaging ; : 251-258, 2019.
Article Dans Anglais | WPRIM | ID: wpr-764180

Résumé

PURPOSE: To assess the feasibility of the use of spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) in livers of children and young adults. MATERIALS AND METHODS: Patients (≤ 20 years old) who underwent 3T SE-EPI MRE were included retrospectively. Subjects were divided into three groups according to the purpose of the liver MRI: suspicion of fatty liver or focal fat deposition in the liver (FAT group), liver fibrosis after receiving a Kasai operation from biliary atresia (BA group), and hepatic iron deposition after receiving chemotherapy or transfusions (IRON group). Technical failure of MRE was defined when a stiffness map showed no pixel value with a confidence index higher than 95%, and the patients were divided as success and failure groups accordingly. Clinical findings including age, gender, weight, height, and body mass index and magnetic resonance imaging results including proton density fat fraction (PDFF), T2*, and MRE values were assessed. Factors affecting failure of MRE were evaluated and the image quality in wave propagation image and stiffness map was evaluated using the appropriate scores. RESULTS: Among total 240 patients (median 15 years, 211 patients in the FAT, 21 patients in the BA, and 8 patients in the IRON groups), technical failure was noted in six patients in the IRON group (6/8 patients, 75%), while there were no failures noted in the FAT and BA groups. These six patients had T2* values ranging from 0.9 to 3.8 ms. The image quality scores were not significantly different between the FAT and BA groups (P > 0.999), while the scores were significantly lower in the IRON group (P < 0.001). CONCLUSION: The 3T SE-EPI MRE in children and young adults had a high technical success rate. The technical failure was occurred in children with decreased T2* value (≤ 3.8 ms) from iron deposition.


Sujets)
Enfant , Humains , Jeune adulte , Atrésie des voies biliaires , Indice de masse corporelle , Traitement médicamenteux , Imagerie échoplanaire , Imagerie d'élasticité tissulaire , Stéatose hépatique , Fer , Cirrhose du foie , Foie , Imagerie par résonance magnétique , Protons , Études rétrospectives
11.
Investigative Magnetic Resonance Imaging ; : 148-156, 2019.
Article Dans Anglais | WPRIM | ID: wpr-764168

Résumé

Hyperglycemia-induced hemichorea (HGHC) is a rare but characteristic hyperkinetic movement disorder involving limbs on one side of the body. In a 75-year-old woman with a left-sided HGHC, conventional brain MR imaging showed very subtle T1-hyperintensity and unique gadolinium enhancement in the basal ganglia contralateral to movements. Multi-parametric MRI was acquired using pulse sequence with quantification of relaxation times and proton density by multi-echo acquisition. Myelin map was reconstructed based on new tissue classification modeling. In this case report of multi-parametric MRI, quantitative measurement of myelin change related to HGHC in brain structures and its possible explanations are presented. This is the first study to demonstrate myelin loss related to hyperglycemic insult in multi-parametric quantitative MR imaging.


Sujets)
Sujet âgé , Femelle , Humains , Noyaux gris centraux , Encéphale , Classification , Membres , Gadolinium , Hyperglycémie , Hypercinésie , Imagerie par résonance magnétique , Troubles de la motricité , Gaine de myéline , Protons , Relaxation
12.
Investigative Magnetic Resonance Imaging ; : 157-161, 2019.
Article Dans Anglais | WPRIM | ID: wpr-764167

Résumé

In this study, we report arterial spin labelling perfusion, proton MR spectroscopy and susceptibility-weighted MR findings of acute necrotizing encephalopathy in a child with rotavirus infection.


Sujets)
Enfant , Humains , Encéphalopathies , Imagerie par résonance magnétique , Spectroscopie par résonance magnétique , Perfusion , Protons , Infections à rotavirus
13.
Asia Pacific Allergy ; (4): e30-2019.
Article Dans Anglais | WPRIM | ID: wpr-762879

Résumé

Proton pump inhibitors (PPIs) are widely used for the treatment of gastrointestinal diseases. Incidence of drug hypersensitivity reactions (DHRs) to PPIs has been rising, presumably because of their increased consumption. Most DHR are IgE-mediated, with half of the reactions being anaphylactic. We describe the case of a Caucasian 50-year-old female patient referred to our allergy department after 2 episodes of anaphylaxis. The allergy work-up distinguished PPI as a cause of delayed onset (14 hours) and immediate onset (45 minutes) IgE-mediated DHR.


Sujets)
Femelle , Humains , Adulte d'âge moyen , Anaphylaxie , Hypersensibilité médicamenteuse , Maladies gastro-intestinales , Hypersensibilité , Incidence , Inhibiteurs de la pompe à protons , Pompes à protons , Protons , Tests cutanés
14.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 135-140, 2019.
Article Dans Anglais | WPRIM | ID: wpr-766331

Résumé

OBJECTIVES: This study sought to investigate the association between the systemic intake of proton pump inhibitors (PPI) and the early failure of dental implants. MATERIALS AND METHODS: A retrospective cohort study involving 1,918 dental implants in 592 patients (69 implants in 24 PPI users and 1,849 implants in 568 nonusers, respectively) was conducted. The effect of PPI intake on the osseointegration of dental implants was evaluated using patient- and implant-level models. RESULTS: Among 24 PPI users, two patients experienced implant failure, one of whom had three and the other of whom had one failed implant, respectively. Thus, the rate of failure for this population was 8.3%. Separately, 11 nonusers each experienced one implant failure, and the failure rate for these patients was 1.9%. Fisher's exact test revealed statistically significant differences between PPI users and nonusers at the implant level (P=0.002) but failed to show any significance at the patient level (P=0.094). The odds of implant failure were 4.60 times greater among PPI users versus nonusers. Dental implants that were placed in patients using PPIs were found to be 4.30 times more likely to fail prior to loading. CONCLUSION: The findings of this study suggest that PPI intake may be associated with an increased risk of early dental implant failure.


Sujets)
Humains , Études de cohortes , Pose d'implant dentaire , Implants dentaires , Morinda , Ostéo-intégration , Inhibiteurs de la pompe à protons , Pompes à protons , Protons , Réadaptation , Études rétrospectives , Facteurs de risque
15.
Journal of Liver Cancer ; : 136-142, 2019.
Article Dans Anglais | WPRIM | ID: wpr-765716

Résumé

Proton beam therapy (PBT) is one of the advances in radiotherapy techniques, which enables dose escalation with lower probability of radiation-induced liver or gastrointestinal injuries. However, the chest wall proximal to the tumor can be affected by high dose irradiation. Here, we report on a 58-year-old male patient who presented with huge hepatocellular carcinoma, received treatment with transarterial chemoembolization and PBT, and developed severe chest wall pain due to radiation-induced myositis. The patient's symptoms were controlled by oral steroids.


Sujets)
Humains , Mâle , Adulte d'âge moyen , Carcinome hépatocellulaire , Foie , Myosite , Protonthérapie , Protons , Radiothérapie , Stéroïdes , Paroi thoracique
16.
Journal of Liver Cancer ; : 159-164, 2019.
Article Dans Anglais | WPRIM | ID: wpr-765712

Résumé

The treatment options available for patients with hepatocellular carcinoma (HCC) with portal vein invasion (PVI) include sorafenib, transarterial radioembolization (TARE), radiation therapy (RT), transarterial chemoembolization with RT, and proton beam irradiation. Herein, we present a case of HCC with segmental PVI that was managed via TARE. The patient had a 4 cm HCC that invaded the segment VIII portal vein branch without extrahepatic spread. Liver function was Child-Pugh grade A, and performance status was good. TARE was performed without any adverse events, and a radiological complete response (CR) was achieved. Thereafter, the patient was followed-up every 3–6 months without any further treatment, and the CR was maintained for >3 years. Therefore, TARE may be a useful alternative therapeutic option for patients with HCC exhibiting segmental PVI.


Sujets)
Humains , Carcinome hépatocellulaire , Embolisation thérapeutique , Foie , Veine porte , Protons , Radiothérapie , Thrombose veineuse
17.
Korean Journal of Pediatrics ; : 384-385, 2019.
Article Dans Anglais | WPRIM | ID: wpr-760181

Résumé

No abstract available.


Sujets)
Enfant , Humains , Inflammation , Inhibiteurs de la pompe à protons , Pompes à protons , Protons
18.
Korean Journal of Pediatrics ; : 400-404, 2019.
Article Dans Anglais | WPRIM | ID: wpr-760178

Résumé

BACKGROUND: An increase in the numbers of patients with gastrointestinal symptoms has recently been observed. PURPOSE: To investigate the effects of proton pump inhibitor (PPI) therapy on intestinal inflammation in children and adolescents as confirmed by clinical manifestations and objectively assessed by fecal calprotectin (FC) level measurement. METHODS: Consecutive children (aged 3–18 years) who presented with gastrointestinal symptoms and were treated with or without PPI for at least 1 month were enrolled. Patients were divided into PPI and non-PPI groups. The PPI group was further subdivided by treatment duration and type of PPI used. Stool samples were collected for FC evaluation at baseline and after treatment and clinical data and FC levels were compared between the groups. RESULTS: Fifty-one patients (15 boys, 36 girls) were enrolled in the study. The PPI group included 37 patients, while the non-PPI group included 14 patients. Clinical symptoms were not significantly different. FC levels and laboratory results, including C-reactive protein levels, white blood cell count, and absolute neutrophil count, were not statistically different before versus after PPI treatment. After treatment, FC levels decreased to 8.1 mg/kg (-575.4 to 340.3 mg/kg) in the PPI group and increased to 5.6 mg/kg (-460.0 to 186.9 mg/kg) in the non-PPI group compared to those before treatment (P=0.841). The number of patients with increased FC levels was not significantly different between the 2 groups (48.6% vs. 64.3%, P=0.363), similar to that observed in patients with an FC level > 50 mg/kg (24.3% and 7.1%, P=0.250). PPI therapy type and duration did not affect the FC levels (P=0.811 and P=0.502, respectively). CONCLUSION: Although we aimed to confirm the evidence of intestinal inflammation due to PPI use in children and adolescents through clinical symptoms and FC measurement, no significant changes were observed.


Sujets)
Adolescent , Enfant , Humains , Protéine C-réactive , Inflammation , Numération des leucocytes , Complexe antigénique L1 leucocytaire , Granulocytes neutrophiles , Inhibiteurs de la pompe à protons , Pompes à protons , Protons
19.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 165-170, 2019.
Article Dans Coréen | WPRIM | ID: wpr-760106

Résumé

BACKGROUND AND OBJECTIVES: Laryngopharyngeal reflux (LPR) is a prevalent condition with an increasing incidence, and several recent studies have reported the association of LPR with chronic rhinosinusitis (CRS). In this study, we studied the effect of proton-pump inhibitors (PPIs) on symptom improvement for LPR and comorbid CRS. SUBJECTS AND METHOD: Enrolled in the study from January 2017 to December 2017 were 164 patients (54 male, 110 female, mean age 48.8 years) who were diagnosed as LPR by reflux symptom index (RSI) or reflux finding scores (RFS) and comorbid CRS. Sino-Nasal Outcome Test (SNOT)-20 and Lund-Kennedy endoscopic scores were evaluated for CRS severity. The study group was divided into PPI treatment group (Ilaprazole 20 mg, once a day for 8 weeks) and non-treatment group. The RSI, RFS, SNOT-20, and Lund-Kennedy endoscopic scores were repeated at the end of treatment. RESULTS: Ninety-two patients were prescribed PPI and 72 patients were not. Initial RSI, RFS, SNOT-20, and Lund-Kennedy score did not differ between the two groups. RSI and RFS decreased significantly after eight weeks of PPI medication (p=0.002 and p<0.001, respectively). In the non-treatment group, only RFS showed statistically significant decrease. SNOT-20 and Lund-Kennedy endoscopic scores decreased significantly in the treatment group (p=0.005 and p<0.001, respectively) compared to the non-treatment group. CONCLUSION: The results of our study suggest that PPI treatment for 8 weeks was effective in reducing signs and symptoms of both LPR and CRS.


Sujets)
Femelle , Humains , Mâle , Incidence , Reflux laryngopharyngé , Méthodes , Pompes à protons , Protons
20.
Korean Journal of Family Medicine ; : 348-350, 2019.
Article Dans Anglais | WPRIM | ID: wpr-759820

Résumé

Anxiety disorders are the most prevalent psychiatric disorders in the general population. The relationship between dyspepsia and particularly gastroesophageal reflux disease (GERD) and psychiatric comorbidity such as anxiety is poorly defined. However, GERD was noted to be strongly associated and often coincident in onset with generalized anxiety disorder in the community. In this paper, we report the case of an adult man who presented with severe weight loss and underlying GERD, and was later found to have an anxiety disorder as the cause of both.


Sujets)
Adulte , Humains , Troubles anxieux , Anxiété , Comorbidité , Dyspepsie , Reflux gastro-oesophagien , Pompes à protons , Protons , , Perte de poids
SÉLECTION CITATIONS
Détails de la recherche