Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtre
1.
Arq. bras. oftalmol ; 82(5): 425-428, Sept.-Oct. 2019. graf
Article Dans Anglais | LILACS | ID: biblio-1019439

Résumé

ABSTRACT A rare case of bilateral congenital microcoria associated with antimetropia in a 47-year-old man is here described. The patient presented with a chief complaint of progressive vision loss in his right eye over the past five years. A slit-lamp examination and ultrasound biomicroscopy confirmed congenital microcoria and cataracts. Phacoemulsification was performed using an iris expansion device and the anterior capsule was stained using the "trypan down under" technique. Preoperative considerations, the surgical approach, and postoperative management are discussed.


RESUMO Um caso raro de microcoria congênita bilateral associada à antimetropia em um homem de 47 anos de idade é descrito aqui. O paciente queixava-se de perda visual progressiva em seu olho direito nos últimos 5 anos. Um exame com lâmpada de fenda e biomicroscopia ultrassônica confirmaram microcoria congênita e catarata. A facoemulsificação foi realizada usando dispositivo de expansão iriana, e a cápsula anterior foi corada através da técnica "trypan down under". Considerações pré-operatórias, abordagem cirúrgica e manejo pós-operatório são discutidos.


Sujets)
Humains , Mâle , Adulte , Adulte d'âge moyen , Solutions ophtalmiques/administration et posologie , Atropine/administration et posologie , Cataracte/complications , Extraction de cataracte , Troubles pupillaires/congénital , Phacoémulsification/méthodes , Troubles pupillaires/chirurgie , Troubles pupillaires/complications , Microscopie acoustique
2.
Arq. bras. oftalmol ; 73(1): 9-15, Jan.-Feb. 2010. ilus, tab
Article Dans Anglais | LILACS | ID: lil-546041

Résumé

PURPOSE: To study the mechanisms of pupillary block in eyes with occludable angle by ultrasound biomicroscopy. METHODS: Initially, a pilot study of 13 eyes with acute primary angle-closure without medication was executed. Ultrasound biomicroscopy measurements of the angle, posterior chamber depth and iris thickness were performed in the temporal quadrant under light and dark conditions. Afterwards, ultrasound biomicroscopy measurements of iris-lens contact distance and iris-lens angle in the temporal quadrant and central anterior chamber depht were made in 32 eyes with acute primary angle-closure or intermittent primary angle-closure without medication, under light and dark conditions before and after laser peripheral iridectomy. RESULTS: In the pilot study, a significant decrease in the angle as well as a significant increase in the iris thickness occurred when comparing light to dark conditions. Before and after laser peripheral iridectomy (second study), significant differences were found in iris-lens contact distance (P<0.001) and iris-lens angle (P<0.001) under light and dark conditions. Also, significant differences were found in light and dark conditions, before laser peripheral iridectomy, in iris-lens angle (P=0.005), and after laser peripheral iridectomy, in iris-lens contact distance (P<0.001). No significant change occurred with anterior chamber depth. CONCLUSIONS: A decreased angle was correlated to an increase in iris thickness. After laser peripheral iridectomy, acute primary angle-closure or primary angle-closure eyes had an increased iris-lens contact distance and a decreased iris-lens angle. The anterior chamber depth did not change. These findings contradict the theory that pupillary block is the mechanism of acute primary angle-closure.


OBJETIVO: Investigar o mecanismo do bloqueio pupilar em olhos com fechamento angular primário agudo ou intermitente por meio da biomicroscopia ultrassônica. MÉTODOS: Inicialmente, fez-se estudo piloto de 13 olhos com fechamento angular primário agudo sem medicação. Medimos pela biomicroscopia ultrassônica, no claro e no escuro, a amplitude do seio camerular, a profundidade da câmara posterior e a espessura da íris no quadrante temporal. Posteriormente, avaliamos pela biomicroscopia ultrassônica 32 olhos com fechamento angular primário agudo ou fechamento angular intermitente sem medicação, no claro e no escuro e antes e após iridectomia periférica. Medimos a distância de contato irido-cristaliniano e o ângulo irido-cristaliniano no quadrante temporal e a profundidade central da câmara anterior. RESULTADOS: No estudo piloto, demonstrou-se com significância estatística redução da amplitude do seio camerular e aumento da espessura iriana quando se passou do claro para o escuro. Antes e após a iridectomia periférica, foram encontradas diferenças estatisticamente significativas na distância de contato irido-cristaliniano (p<0,001) e no ângulo irido-cristaliniano (p<0,001) ambos no claro e no escuro. Foram encontradas diferenças, estatisticamente significativas, no claro e no escuro, antes da iridectomia periférica no ângulo irido-cristaliniano (p=0,005) e, após a iridectomia periférica na distância de contato irido-cristaliniano (p<0,001). Nenhuma diferença significativa ocorreu na profundidade central da câmara anterior. CONCLUSÕES: A diminuição da amplitude do seio camerular correspondeu somente ao aumento da espessura da íris. Após a iridectomia periférica, os olhos com fechamento angular primário agudo ou fechamento angular intermitente apresentaram, com significância estatística, aumento da distância de contato irido-cristaliniano e diminuição do ângulo irido-cristaliniano. A profundidade central da câmara anterior não se alterou. Esses ...


Sujets)
Femelle , Humains , Mâle , Adulte d'âge moyen , Glaucome à angle fermé , Microscopie acoustique , Troubles pupillaires , Maladie aigüe , Glaucome à angle fermé/étiologie , Projets pilotes , Troubles pupillaires/complications
SÉLECTION CITATIONS
Détails de la recherche