Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta ortop. bras ; 31(1): e261132, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1419966

RESUMO

ABSTRACT Objective: To evaluate a possible increase of adhesive capsulitis incidence during the COVID-19 pandemic. Methods: A total of 1,983 patients with shoulder disorders were retrospectively analyzed regarding gender, age, development of adhesive capsulitis and comorbidities (systemic arterial hypertension, diabetes mellitus, dyslipidemia, hypothyroidism, hyperthyroidism, depression, and anxiety) in two different periods: from March 2019 to February 2020 and from March 2020 to February 2021. Descriptive and quantitative variables were statistically analyzed. The program used for the calculations was SPSS 17.0 for Windows. Results: During the pandemic, there was a 2.41-fold increase (p < 0.001) in cases of adhesive capsulitis (compared to the previous year). Patients with depression and anxiety had a significantly increased risk by 8.8 (p < 0.001) and 14 (p < 0.001) times, respectively, of developing frozen shoulder (regarding the two periods studied). Conclusion: A significant increase in the incidence of frozen shoulder was observed after the onset of the COVID-19 pandemic in addition to a simultaneous increase of psychosomatic disorders. Prospective studies would help to ratify the idea contained in this research. Level of Evidence III, Observational Cross-Sectional Study.


RESUMO Objetivo: Avaliar se houve aumento da incidência de capsulite adesiva durante a pandemia de COVID-19. Métodos: Foram analisados, retrospectivamente, 1.983 pacientes com desordens do ombro quanto a sexo, idade, desenvolvimento de capsulite adesiva e comorbidades (hipertensão arterial sistêmica, diabetes mellitus, dislipidemia, hipo/hipertireoidismo, depressão e ansiedade) em dois períodos distintos: de março de 2019 a fevereiro de 2020 e de março de 2020 a fevereiro de 2021. Procedeu-se à análise estatística das variáveis descritivas e quantitativas, utilizando o software SPSS 17.0 for Windows para os cálculos. Resultados: Durante a pandemia, houve aumento de 2,41 vezes (p < 0,001) de casos de capsulite adesiva em relação ao ano anterior. Considerando os períodos estudados, pacientes com depressão e ansiedade apresentaram um risco significativamente aumentado em 8,8 (p < 0,001) e 14 (p < 0,001) vezes, respectivamente, de desenvolver a patologia em questão. Conclusão: Observou-se um aumento significativo da incidência de ombro congelado após o início da pandemia de COVID-19, além de sua relação com distúrbios psicossomáticos. São necessários estudos prospectivos futuros para ratificar a ideia contida nesta pesquisa. Nível de Evidência III, Estudo Transversal Observacional.

2.
Acta ortop. bras ; 31(5): e264116, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1519947

RESUMO

ABSTRACT Objective: To evaluate the effectiveness of the dorsal fixation technique with a cannulated compression screw (CCS) for transverse scaphoid neck fractures. Methods: A case series study was carried out with patients treated with a CSS between April 2014 and May 2021. The main outcome was the healing of the fracture, verified by radiographic evaluation that used images of the wrist in anteroposterior, lateral, radial deviation, ulnar deviation and oblique views, obtained in the postoperative period. Results: Fifty-two patients aged between 15 and 65 years were analyzed, of which 43 (83%) were male. Of the 52 patients, 19 (36.53%) had a right-hand injury and 33 (63.46%) had a left-hand injury. Results were excellent in 47 patients (90.38%); good in 4 patients (7.69%), with reduced mobility compared to contralateral and poor in 1 patient (1.92%), with failure of consolidation and breakage of the synthesis material. In 51 cases (99%) there was bone consolidation at the end of six months. Conclusion: Osteosynthesis with a cannulated compression screw is a safe, effective and promising method for the treatment of scaphoid neck fractures. Level of Evidence IV, Case Series.


RESUMO Objetivo: Avaliar a eficácia da técnica de fixação dorsal com parafuso canulado de compressão (CCS) para fraturas transversas do colo do escafoide. Métodos: Foi realizado um estudo de série de casos com pacientes tratados com CSS entre abril de 2014 e maio de 2021. O desfecho principal foi a consolidação da fratura, verificada por meio da avaliação radiográfica das imagens do punho em anteroposterior, perfil, desvio radial, desvio ulnar e oblíquo obtidas no pós-operatório. Resultados: Foram analisados 52 pacientes com idade entre 15 e 65 anos, sendo 43 (83%) do sexo masculino. Dos 52 pacientes, 19 (36,53%) tinham lesão na mão direita e 33(63,46%) na mão esquerda. Os resultados foram excelentes em 47 dos pacientes (90,38%); bons em quatro (7,69%), com mobilidade reduzida comparada ao membro contralateral; e ruim em um (1,92%), com falha da consolidação e quebra do material de síntese. Em 51 casos (99%) houve consolidação óssea ao final de seis meses. Conclusão: A osteossíntese com parafuso canulado de compressão é um método seguro, eficaz e promissor para o tratamento das fraturas no colo do escafoide. Nível de Evidência IV, Série de Casos.

3.
Acta ortop. bras ; 29(4): 219-222, Aug. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1339052

RESUMO

ABSTRACT Objective: To perform a systematic review of the main methods and indications of interposition arthroplasty in the rigid elbow. Methods: The research was carried out by three independent researchers, in the databases PubMed, Medline and Embase, according to the descriptors selected as a research strategy and filters selected in the inclusion criteria. Results: In total, 21 studies were found with the afore mentioned descriptors and which were considered adequate according to the design and relevance according to the type of study and inclusion filters. There was a very strong correlation between the searches of the three researchers (k = 0.809). At the end, 14 complete studies were presented, all of which were included. Conclusion: The main finding of this study was to note that there is an evident lack of research with a high level of real effectiveness and indication for interposition arthroplasty in the rigid elbow. Most studies point to positive results when the patient is young and a total arthroplasty is not indicated. No meta-analysis or randomized clinical trial was found for this specific topic, despite being a technique applied in clinical practice for some decades and showing good results. Level of Evidence V, Systematic Review.


RESUMO Objetivo: Realizar uma revisão sistemática dos principais métodos e indicações da artroplastia de interposição em cotovelo rígido. Métodos: Pesquisa realizada por três pesquisadores independentes nas bases de dados PubMed, Medline e Embase, segundo os descritores selecionados como estratégia de busca e filtros estabelecidos nos critérios de inclusão. Resultados: Foram encontrados 21 estudos com os descritores selecionados, que foram avaliados conforme seu desenho e relevância segundo os filtros do tipo de estudo e critérios de inclusão. Houve correlação muito forte entre as buscas dos três pesquisadores (k = 0,809). Ao final, restaram 14 estudos completos, e todos foram incluídos. Conclusão: Observou-se que existe uma carência evidente de pesquisas com nível de confiabilidade alto para a real eficácia e indicação da artroplastia de interposição no cotovelo rígido. A maioria dos trabalhos aponta para resultados positivos quando o paciente é jovem e a artroplastia total não é indicada. Não foi encontrada nenhuma metanálise ou ensaio clínico randomizado para esse tema específico, apesar de ser uma técnica aplicada na prática clínica há algumas décadas e que apresenta bons resultados. Nível de Evidência V, Revisão Sistemática.

4.
Acta ortop. bras ; 25(5): 209-211, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-886491

RESUMO

ABSTRACT Objective: The objective of this study was to analyze elbow injuries and their probable mechanism in Jiu-Jitsu fighters resulting from the armbar-type armlock. Methods: We evaluated 5 high-performance Jiu-Jitsu fighters from the Gracie Elite gym who were injured during a tournament. All were healthy males with a mean age of 28.8 years. The right arm was involved in three patients (60%). The athletes were followed for approximately 4.6 months, and pain was present in all cases. Clinical examination of the elbow was performed immediately after the injury and when magnetic resonance imaging (MRI) was performed. The radiography showed no changes. Clinical examination detected specific tender points on the medial and anterior topography of the elbows, but no ligamentous instability of the elbow was seen during dynamic testing. Results: The main MRI findings were injury to the common flexor tendon and the ulnar collateral ligament, bone contusion of the distal humerus and olecranon, and joint effusion. Conclusion: The main pattern of injury indicated by the MRI in the athletes was injury to the medial elbow complex. The primary mechanism that determined the injury was most likely elbow hyperextension applied with the forearm in neutral position of forearm. Level of Evidence IV, Case Series.


RESUMO Objetivo: Demonstrar os resultados da análise das lesões do cotovelo e seu provável mecanismo em cinco atletas lutadores de jiu-jítsu decorrentes da chave de braço do tipo armlock. Métodos: Foram avaliados cinco lutadores de jiu-jítsu da academia Gracie Elite, de alto rendimento esportivo, que sofreram lesão durante a realização de um campeonato dessa modalidade. Todos eram do sexo masculino, com média de idade 28,8 anos, hígidos que sofreram lesão durante a participação nesse torneio. O braço direito foi acometido em três pacientes (60%). O seguimento dos atletas foi, em média, de 4,6 meses, sendo que a queixa de dor estava presente em todos os casos. O exame clínico da região do cotovelo foi realizado imediatamente após a ocorrência da lesão e no momento da realização do exame de ressonância magnética (RM). O exame radiográfico não demonstrou alterações. Durante o exame clínico, foram detectados pontos dolorosos específicos na topografia medial e anterior dos cotovelos examinados, na qual não se observaram instabilidades ligamentares do cotovelo durante os testes dinâmicos. Resultados: Os principais achados da RM foram: lesão do tendão comum dos músculos flexores e do ligamento colateral ulnar, contusão óssea na porção distal do úmero e do olécrano e derrame articular. Conclusão: O principal padrão de lesão reconhecido pela RM nos atletas estudados foi a lesão do complexo medial do cotovelo. Sugerimos que o mecanismo primário que determinou as lesões foi a hiperextensão do cotovelo aplicada com a posição neutra do antebraço. Nível de Evidência IV, Série de Casos.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA