RESUMO
ABSTRACT Hemoglobin A1c (HbA1c) measurement is commonly performed in diabetes mellitus patients to monitor glycemic control over the last three to four months. Carbamylated hemoglobin, which is the hemoglobin that binds to isocyanic acid derived from urea, is one of the possible analytical interference in the uremic patient. When measured by ion-exchange high-performance liquid chromatography (HPLC), carbamylated hemoglobin forms a peak that overlaps the peak of HbA1c, causing a falsely elevated HbA1c result. We report a case of a 60-years-old man who had a spurious increase in HbA1c, with a high carbamylated hemoglobin peak disproportionate to the urea value. Subsequent hemoglobin analysis using hemoglobin electrophoresis and HPLC hemoglobin testing system suggested hemoglobin J (Hb J) variant. Our case highlighted the possibility of misleading HbA1c interpretation in the presence of a high carbamylated hemoglobin peak, but not proportionate to urea value. In this study, Hb J was detected. A method free from hemoglobin variant interference should be used ideally, and monitoring glycemic control should be performed using alternative methods, such as serum fructosamine or continuous glucose monitoring.
RESUMEN La prueba de la hemoglobina glicosilada A1c (HbA1c) se realiza comúnmente en pacientes con diabetes mellitus para monitorear el control glucémico durante los últimos tres o cuatro meses. La hemoglobina carbamilada, que es la hemoglobina que se une al ácido isociánico derivado de la urea, es una de las posibles interferencias analíticas en el paciente urémico. Cuando se mide mediante cromatografía líquida de alta eficacia (HPLC) de intercambio iónico, la hemoglobina carbamilada forma un pico que se superpone al pico de HbA1c, lo que provoca un resultado de HbA1c falsamente elevado. Presentamos el caso de un hombre de 60 años que tuvo un aumento espurio de HbA1c, con un pico de hemoglobina carbamilada alto desproporcionado al valor de urea. El análisis de hemoglobina posterior mediante electroforesis de hemoglobina y el sistema de prueba de hemoglobina HPLC sugirió una variante de hemoglobina J (Hb J). Nuestro caso destacó la posibilidad de una interpretación engañosa de la HbA1c en presencia de un pico de hemoglobina carbamilada alto, pero no proporcional al valor de urea. En este estudio, se detectó Hb J. Lo ideal sería utilizar un método libre de interferencia de variantes de hemoglobina, y la monitorización del control glucémico debería realizarse mediante métodos alternativos, como la fructosamina sérica o la monitorización continua de la glucosa.
RESUMO A dosagem de hemoglobina A1c (HbA1c) é comumente realizada em pacientes com diabetes mellitus para monitorar o controle glicêmico nos últimos três a quatro meses. A hemoglobina carbamilada - hemoglobina que se liga ao ácido isociânico derivado da ureia - é uma das possíveis interferências analíticas no paciente urêmico. Quando medida por cromatografia líquida de alta eficiência (HPLC) por troca iônica, a hemoglobina carbamilada forma um pico que se sobrepõe ao pico da HbA1c, causando um resultado falsamente elevado da HbA1c. Relatamos o caso de um homem de 60 anos de idade que apresentava um aumento espúrio de HbA1c, com alto pico de hemoglobina carbamilada desproporcional ao valor de ureia. A análise subsequente da hemoglobina usando eletroforese de hemoglobina e sistema de teste de hemoglobina por HPLC sugeriu a variante de hemoglobina J (Hb J). Nosso caso destacou a possibilidade de interpretação enganosa da HbA1c na presença de um pico alto de hemoglobina carbamilada, mas não proporcional ao valor da ureia. Neste estudo, foi detectada a Hb J. Um método isento de interferência de variantes da hemoglobina deve ser idealmente usado, e o monitoramento do controle glicêmico deve ser feito usando métodos alternativos, como frutosamina sérica ou monitoramento contínuo da glicose.