Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Chinese Medical Journal ; (24): 1026-1032, 2013.
Artigo em Inglês | WPRIM | ID: wpr-342244

RESUMO

<p><b>BACKGROUND</b>Previous studies indicated that long coronary lesions are one of the key predictors of drug-eluting stent (DES) failure. The purpose of this study was to evaluate the efficacy and the safety of the long length FIREHAWK(®) stent in long coronary artery disease.</p><p><b>METHODS</b>The long cohort of TARGET I was a prospective, multicenter, single arm trial. It was planned to enroll 50 patients undergoing percutaneous coronary intervention (PCI) for the treatment of de novo long lesions in a native coronary artery. The major inclusion criteria of the trial was that patients were intended to undergo the treatment of a long target lesion(s) with diameter stenosis ≥ 70% and reference vessel diameter 2.5 mm to 4.0 mm by visual estimate, that needed to be covered by at least one 33 mm or 38 mm stent or multiple long stents overlapped. The angiographic follow-up was planned at 9-month and the clinical follow-up will be up to 5 years. The primary end point was in-stent late lumen loss at 9-month.</p><p><b>RESULTS</b>Fifty patients (mean age (57.6 ± 10.2) years) with 59 de novo long lesions (reference vessel diameter (2.85 ± 0.44) mm, lesion length (35.2 ± 9.4) mm, and stent length (41.8 ± 11.3) mm) were enrolled. The angiographic follow-up rate was 92% at 9-month. The in-stent late loss was (0.16 ± 0.16) mm. Proximal edge, distal edge and in-segment late loss (mm) were 0.21 ± 0.35, 0.03 ± 0.33, and 0.07 ± 0.26, respectively. No in-segment binary restenosis was observed. At 1-year no death, Q wave myocardial infarction (MI), or stent thrombosis occurred. Non-Q-wave MI occurred in two patients (4%) due to procedural complications.</p><p><b>CONCLUSIONS</b>Treatment of long coronary lesions with the FIREHAWK(®) stent is able to produce similar results as observed in the FIREHAWK(®) FIM clinical trial. Based on this result, we are confident in the treatment prospect of the FIREHAWK(®) for long coronary lesions.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença da Artéria Coronariana , Tratamento Farmacológico , Terapêutica , Stents Farmacológicos , Estudos Prospectivos , Sirolimo , Usos Terapêuticos , Resultado do Tratamento
2.
Chinese Medical Journal ; (24): 970-976, 2012.
Artigo em Inglês | WPRIM | ID: wpr-269314

RESUMO

<p><b>BACKGROUND</b>Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis. We report the first in human experience with the rapamycin-eluting biodegradable polymer coated cobalt-chromium FIREHAWK stent with abluminal groove.</p><p><b>METHODS</b>A total of 21 patients with stable or unstable angina, or prior myocardial infarction, with single de novo native coronary stenoses < 30 mm in length in vessel sizes ranging from 2.25 to 4.0 mm were enrolled. The primary endpoint was major adverse cardiac events (MACE) at 30 days defined as the composite of cardiac death, myocardial infarction (Q and non-Q), or ischemia-driven target lesion revascularization. Secondary endpoints include device, lesion, and clinical success rates, 4-month in-stent late lumen loss by quantitative coronary angiography (QCA), proportion of uncovered or malapposed stent struts by optical coherence tomograpphy (OCT) at 4 months, and MACE at 4, 12, 24 and 36-month follow-up.</p><p><b>RESULTS</b>Device success was 95.7%, lesion and clinical success was 100.0%. There were no MACE events at 30 days. One patient died of non-cardiac hemorrhagic stroke 5 days after index procedure. At 4 months, in-stent late loss was (0.13 ± 0.18) mm, and complete strut coverage was 96.2% by OCT with 0.1% strut malapposition. At 4-month follow-up there was no additional MACE events, and a single target vessel (non-target lesion) revascularization.</p><p><b>CONCLUSIONS</b>The FIREHAWK abluminal groove biodegradable polymer rapamycin-eluting stent demonstrated feasibility, safety and efficacy in this first in human experience. OCT findings indicated excellent stent strut coverage 4 months after implantation. Larger studies are required to confirm whether the early FIREHAWK stent results translate into longer term restenosis and thrombosis benefits.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia Coronária com Balão , Angiografia Coronária , Doença da Artéria Coronariana , Terapêutica , Stents Farmacológicos , Seguimentos , Polímeros , Sirolimo , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA