RESUMO
Objective: To determine the predictive value of repeated abdominal ultrasonography in patients with multiple trauma and decreased level of consciousness [LOC]
Methods: This prospective cross-sectional study was conducted over a six-month period at Shahid Rajaee Trauma Hospital, Shiraz, Iran. We included hemodynamically stable blunt abdominal trauma patients with a decreased LOC [Glasgow Coma Scale = 13] who were referred to the neurosurgery ICU ward. Included cases underwent 1 contrast-enhanced CT scan and two-time ultrasonographic study of the abdomen with an interval of 48 hours. The diagnostic accuracy of the ultrasonography was determined according to the CT-scan results
Results: Overall 80 patients with mean age of 37.75 +/- 18.67 years were included. There were 17 [21.3%] women and 63 [78.8%] men among the patients. Compared with the CT-Scan, the first ultrasonography showed a sensitivity of 60%, specificity of 80%, PPV of 16.60%, NPV of 96.80%, and a diagnostic accuracy of 70%. The same values for the second ultrasonographic study were 80%, 79%, 20%, 98%, and 79%, respectively. In 4 [5%] patients whose first ultrasonography and CT scan results were negative, the second ultrasonography was positive for injury
Conclusion: In patients with blunt trauma to the abdomen, when the only indication of abdominal CT scan is a decreased LOC, two ultrasonographic studies can replace a CT imaging
RESUMO
Statement of the Problem: Impaction of foreign bodies in the soft tissues is a sequela of traumatic and penetrating injuries. Such foreign bodies should be removed due to the complications they cause. Patient's history, clinical evaluation and imaging examinations aid in the proper detection and localization of the foreign bodies
Purpose: The aim of the present study was to compare the sensitivity of computed tomography [CT] and ultrasonography for detecting foreign bodies in in-vitro models simulating facial soft tissues
Materials and Method: Fifty foreign particles with five different compositions including wood, glass, metal, plastic, and stone were embedded in five calf tongues at 1, 2, 3, 4 and 5 cm depths. CT and ultrasonography were compared regarding their capability of detecting and localizing the foreign bodies
Results: Wood and plastic foreign bodies were demonstrated more clearly on ultrasonography images. High density materials such as metal, stone, and glass were detected with almost the same accuracy on CT and ultrasonography examinations. Visibility of the foreign bodies deteriorated on ultrasonography images as their depth increased; however, CT appearances of the foreign particles were not influenced by their depths
Conclusion: Ultrasonography is an appropriate technique for detection of foreign bodies especially the ones with low density. Therefore, it seems logical to perform ultrasonography in combination with CT in cases with the suspicion of foreign body impaction
RESUMO
Statement of the Problem: Jaw bone lesions are common pathologic conditions. The role of ultrasonography in evaluation of the extra-osseous lesions is confirmed, however, this imaging modality is not the diagnostic routine for the intraosseous jaw lesions
Purpose: The purpose of this study was to evaluate the efficiency of ultrasonography in diagnosis of intra-osseous jaw lesions concerning their size and content and also to study its correlation with the histopathological findings
Materials and Method: For this study, 15 patients with intra-osseous jaw lesions in the maxilla and mandible were selected from those referred to the Department of Oral Surgery. Panoramic imaging, computed tomography [CT] or cone beam computed tomography [CBCT] and ultrasonography [USG] were performed for all the lesions. The size of the lesions was measured by USG and then compared with CT or CBCT. Moreover, the correlation amongst the echographic patterns and histopathologic results was evaluated
Results: In 12 cases, size values were in complete agreement with CT or CBCT. The size of 3 lesions could not be measured by the radiologist due to the thickness of buccal cortical plate
Conclusion: Findings of this study suggested that USG might be feasible in estimating the size of intra-osseous jaw lesions with little underestimation. This study also confirmed that ultrasound imaging was a very useful imaging technique which could provide significant diagnostic information regarding the content of jaw bone lesions where the buccal bone thickness was thin enough
RESUMO
Today, ultrasound imaging is being widely used to assess soft tissue lesions in the maxillofacial region. However, ultrasound investigations of intra-osseous lesions are rare, especially for tumors of the jaws. This report emphasized the capability of this useful imaging modality in identification of the characteristics of malignant conditions involving the bone. Mesenchymal chondrosarcoama, one of the unusual malignant conditions of the jaw, was presented in a young male with significant facial swelling. Different imaging modalities parallel with the histopathologic investigation confirmed the diagnosis. Interestingly, destruction of the bony cortex and new bone formation with a characteristic "sun ray appearance", highly suggestive of sarcomas, was manifested on the ultrasonograph. Thus, this report presented the ultrasonographic features of chondrosarcoma of mandible and considered the ultrasonography to be a useful imaging modality to evaluate intra-osseous jaw lesions.