1.
Braz. j. med. biol. res ; 39(4): 483-487, Apr. 2006. tab
Artigo em Inglês | LILACS | ID: lil-425083

RESUMO

Recent data from our laboratory have shown that patients with the indeterminate form of Chagas' disease can have impairment of left ventricular contractility, as evaluated by the slope of the left ventricle end-systolic pressure-dimension relationship. We also showed that Chagas' disease patients with minimal baseline wall motion abnormalities detected by two-dimensional echocardiography have more intense contractility impairment when compared to patients with the indeterminate form of the disease without this abnormality. The prognostic implications of these findings have not been established. We evaluated 59 patients (37-76 years, mean = 55 years) with different clinical forms of Chagas' disease, who had normal left ventricular global systolic function at baseline (57.6 ± 6.9 percent) and who had at least one additional echo during clinical follow-up (0.4-17.6; mean 4.6 years). Group 1 consisted of 14 patients with minor baseline left ventricle wall motion abnormalities and group 2 consisted of 45 patients without these abnormalities. During follow-up, global left ventricle systolic function deterioration was observed in 10 group 1 patients (71.4 percent) and in only 10 group 2 patients (22.2 percent; P < 0.005). Age and duration of follow-up were not independent determinants of left ventricular function deterioration in these patients. The present data indicate that mild segmental left ventricular wall motion abnormalities are associated with worsening of systolic function in Chagas' disease patients who have normal baseline global systolic performance.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Chagas/fisiopatologia , Contração Miocárdica/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Doença Crônica , Cardiomiopatia Chagásica/fisiopatologia , Cardiomiopatia Chagásica , Ecocardiografia , Seguimentos , Prognóstico , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda
2.
Braz. j. med. biol. res ; 39(1): 1-7, Jan. 2006. ilus
Artigo em Inglês | LILACS | ID: lil-419153

RESUMO

The present study describes an auxiliary tool in the diagnosis of left ventricular (LV) segmental wall motion (WM) abnormalities based on color-coded echocardiographic WM images. An artificial neural network (ANN) was developed and validated for grading LV segmental WM using data from color kinesis (CK) images, a technique developed to display the timing and magnitude of global and regional WM in real time. We evaluated 21 normal subjects and 20 patients with LVWM abnormalities revealed by two-dimensional echocardiography. CK images were obtained in two sets of viewing planes. A method was developed to analyze CK images, providing quantitation of fractional area change in each of the 16 LV segments. Two experienced observers analyzed LVWM from two-dimensional images and scored them as: 1) normal, 2) mild hypokinesia, 3) moderate hypokinesia, 4) severe hypokinesia, 5) akinesia, and 6) dyskinesia. Based on expert analysis of 10 normal subjects and 10 patients, we trained a multilayer perceptron ANN using a back-propagation algorithm to provide automated grading of LVWM, and this ANN was then tested in the remaining subjects. Excellent concordance between expert and ANN analysis was shown by ROC curve analysis, with measured area under the curve of 0.975. An excellent correlation was also obtained for global LV segmental WM index by expert and ANN analysis (R² = 0.99). In conclusion, ANN showed high accuracy for automated semi-quantitative grading of WM based on CK images. This technique can be an important aid, improving diagnostic accuracy and reducing inter-observer variability in scoring segmental LVWM.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Ecocardiografia/métodos , Hipertrofia Ventricular Esquerda , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Disfunção Ventricular Esquerda , Estudos de Casos e Controles , Modelos Lineares , Curva ROC , Índice de Gravidade de Doença
3.
Braz. j. med. biol. res ; 34(7): 903-911, July 2001. ilus
Artigo em Inglês | LILACS | ID: lil-298674

RESUMO

To compare the sensitivity of dipyridamole, dobutamine and pacing stress echocardiography for the detection of myocardial ischemia we produced a physiologically significant stenosis in the left circumflex artery of 14 open-chest dogs (range: 50 to 89 percent reduction in luminal diameter). In each study, dobutamine (5 to 40 æg kg-1 min-1 in 3-min stages) and pacing (20 bpm increments, each 2 min, up to 260 bpm) were performed randomly, and then followed by dipyridamole (up to 0.84 mg/kg over 10 min). The positivity of stress echocardiography tests was quantitatively determined by a significant (P<0.05) reduction of or failure to increase absolute and percent systolic wall thickening in the stenotic artery supplied wall, as compared to the opposite wall (areas related to the left anterior descending artery). Systolic and diastolic frozen images were analyzed off-line by two blinded observers in the control and stress conditions. The results showed that 1) the sensitivity of dobutamine, dipyridamole and pacing stress tests was 57, 57 and 36 percent, respectively; 2) in animals with positive tests, the mean percent change of wall thickening in left ventricular ischemic segments was larger in the pacing (-19 Ý 11 percent) and dipyridamole (-18 Ý 16 percent) tests as compared to dobutamine (-9 Ý 6 percent) (P = 0.05), but a similar mean reduction of wall thickening was observed when this variable was normalized to a control left ventricular segment (area related to the left anterior descending artery) (pacing: -16 Ý 7 percent; dipyridamole: -25 Ý 16 percent; dobutamine: -26 Ý 10 percent; not significant), and 3) a significant correlation was observed between magnitude of coronary stenosis and left ventricular segmental dysfunction induced by ischemia in dogs submitted to positive stress tests. We conclude that the dobutamine and dipyridamole stress tests showed identical sensitivities for the detection of myocardial ischemia in this one-vessel disease animal model with a wide range of left circumflex artery stenosis. The pacing stress test was less sensitive, but the difference was not statistically significant. The magnitude of segmental left ventricular dysfunction induced by ischemia was similar in all stress tests evaluated


Assuntos
Animais , Dipiridamol , Dobutamina , Isquemia Miocárdica , Doença das Coronárias , Modelos Animais de Doenças , Ecocardiografia/métodos , Modelos Lineares , Sensibilidade e Especificidade , Índice de Gravidade de Doença
4.
Braz. j. med. biol. res ; 33(3): 341-6, Mar. 2000. ilus
Artigo em Inglês | LILACS | ID: lil-255053

RESUMO

A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25 per cent corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.


Assuntos
Humanos , Ecocardiografia Doppler em Cores , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Fluxo Pulsátil , Pressão Sanguínea , Átrios do Coração
SELEÇÃO DE REFERÊNCIAS