Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
3.
Rev. bras. cardiol. invasiva ; 21(4): 311-318, out.-dez. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-703681

RESUMO

INTRODUÇÃO: Há poucos dados na literatura que avaliam a obstrução coronária após implante transcateter de válvula aórtica (TAVI, do inglês transcatheter aortic valve implantation) para o tratamento de disfunção de bioprótese aórtica (valve-in-valve - ViV). O presente estudo avaliou, por meio de revisão sistemática da literatura, as características clínicas, o manejo e os desfechos clínicos de pacientes com obstrução coronária após TAVI-ViV. MÉTODOS: Estudos publicados entre 2002 e 2013 avaliando a obstrução coronária como complicação de TAVI-ViV foram identificados por meio de busca eletrônica sistemática. Foram avaliados dados basais sobre as características clínicas e do procedimento, manejo da complicação e desfechos clínicos. RESULTADOS: Foram identificadas, no total, quatro publicações descrevendo sete pacientes. A maioria dos pacientes era do sexo feminino (71%), sendo a média de idade de 82 ± 5 anos, com STS-PROM de 9,4 ± 2,6%. As médias da altura do tronco da artéria coronária esquerda (TCE) e o diâmetro médio da raiz aórtica foram de 8,8 ± 1,5 mm e 28,0 ± 5,0 mm, respectivamente. A maioria dos pacientes apresentava biopróteses com suporte e folhetos montados externamente, ou eram próteses sem suporte (stentless) e o TCE foi envolvido em todos os casos. A intervenção coronária percutânea (ICP) foi tentada em todos os pacientes, tendo sucesso em quatro deles (57%). A mortalidade intra-hospitalar foi 42,9% (três casos), todos após ICP sem sucesso. CONCLUSÕES: A obstrução coronária após TAVI-ViV ocorreu mais frequentemente em mulheres com bioprótese com suporte e folheto montado externamente ou com bioprótese sem suporte. O TCE foi envolvido em todos os casos e a ICP foi realizada com sucesso em 60% deles. Esforços contínuos poderão auxiliar na detecção dos fatores associados a essa complicação, no intuito de se implementarem medidas apropriadas para sua prevenção.


BACKGROUND: Very few data exist on coronary obstruction following transcatheter aortic valve implantation (TAVI) for degenerative bioprosthetic valves (valve-in-valve - ViV). The present study evaluated, through a systematic review of the literature, the clinical characteristics, management and clinical outcomes of patients with coronary obstruction after ViV-TAVI. METHODS: Studies published between 2002 and 2013 evaluating coronary obstruction as a complication of ViV-TAVI were identified using a systematic electronic search. Data on the clinical and procedural characteristics, management of the complication, and clinical outcomes were analyzed. RESULTS: A total of four publications describing seven patients were identified. Most patients (71%) were women, with mean age of 82 ± 5 years, and STS-PROM score of 9.4 ± 2.6%. Mean left coronary artery (LCA) ostium height and aortic root width were 8.8 ± 1.5 mm and 28.0 ± 5.0 mm, respectively. Most patients had stented bioprosthetic valves with externally mounted leaflets or stentless aortic bioprosthesis, and the LCA was involved in all patients. Percutaneous coronary intervention (PCI) was attempted in all patients and was successful in four (57%). In-hospital mortality was 42.9% (three cases), all of them after failed PCI. CONCLUSIONS: Coronary obstruction following ViV-TAVI occurred more frequently in women with stented bioprosthetic valves with externally mounted leaflets or with stentless bioprosthesis. The LCA was involved in all cases and PCI was successful in 60% of them. Continued efforts may help identify the factors associated with this complication so that appropriate prevention measures may be implemented.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Oclusão Coronária/fisiopatologia , Valva Aórtica/fisiopatologia , Ecocardiografia , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA