Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Heart Views. 2015; 16 (4): 125-130
em Inglês | IMEMR | ID: emr-175749

RESUMO

Background: The implantable cardioverter-defibrillator [ICD] is effective in the prevention of sudden cardiac death in high-risk patients. Little is known about ICD use in the Arabian Gulf. We designed a study to describe the characteristics and outcomes of patients receiving ICDs in the Arab Gulf region


Methods: Gulf ICD is a prospective, multi-center, multinational, and observational study. All adult patients 18 years or older, receiving a de novo ICD implant and willing to sign a consent form will be eligible. Data on baseline characteristics, ICD indication, procedure and programing, in-hospital, and 1-year outcomes will be collected. Target enrollment is 1500 patients, which will provide adequate precision across a wide range of expected event rates


Results: Fifteen centers in six countries are enrolling patients [Saudi Arabia, United Arab Emirates, Kuwait, Oman, Bahrain, and Qatar]. Two-thirds of the centers have dedicated electrophysiology laboratories, and in almost all centers ICDs are implanted exclusively by electrophysiologists. Nearly three-quarters of the centers reported annual ICD implant volumes of

Conclusions: Gulf ICD is the first prospective, observational, multi-center, and multinational study of the characteristics and, the outcomes of patients receiving ICDs in the Arab Gulf region. The study will provide valuable insights into the utilization of and outcomes related to ICD therapy in the Gulf region


Assuntos
Humanos , Sistema de Registros , Estudos Prospectivos , Estudos Multicêntricos como Assunto , Fatores de Risco , Morte
2.
Journal of Tehran University Heart Center [The]. 2012; 7 (2): 78-81
em Inglês | IMEMR | ID: emr-144339

RESUMO

Spontaneous coronary artery dissection [SCAD] is a rare condition that can result in unstable angina, acute myocardial infarction, and sudden death. This condition may occur particularly in women during late pregnancy and in the postpartum period. We present the case of a 33-year-old African American woman, who had spontaneous left anterior descending coronary artery [LAD] dissection two weeks postpartum, resulting in acute ST-segment elevation myocardial infarction with severe left ventricular dysfunction. The use of the intravascular ultrasound [IVUS] in our case confirmed the diagnosis and helped with stent sizing and implantation. On subsequent follow-up, there was marked left ventricular function recovery and clinical improvement


Assuntos
Humanos , Feminino , Adulto , Dissecação , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária , Infarto do Miocárdio/etiologia , Eletrocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA